Content
... ... @@ -231,8 +231,7 @@
231 231  * HMI setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/>>https://docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/]]
232 232  * PLC setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/>>https://docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/]]
233 233  
234 -(% class="wikigeneratedid" id="HPLCsettings" %)
235 -**PLC settings**
234 +== PLC settings ==
236 236  
237 237  **Download PLC Software**
238 238  
... ... @@ -469,46 +469,10 @@
469 469  
470 470  The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
471 471  
472 -= Create communication with **Rockwell PLC** =
471 += =
473 473  
473 += **Allen-Bradley** =
474 474  
475 -== **MicroLogix Protocol** ==
476 -
477 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
478 -
479 -**HMI Settings**
480 -
481 -(% class="table-bordered" %)
482 -|**Item**|**Settings**|**Note**
483 -|Protocol|Allen-Bradlley MicroLogix|
484 -|Connection|RS232|
485 -|Baud rate|19200|
486 -|Data bit|8|
487 -|Parity|None|
488 -|Stop bit|1|
489 -|PLC station No.|1|
490 -
491 -**Address List**
492 -
493 -(% class="table-bordered" %)
494 -|**Type**|**Device registers**|**Format**|**Range**|**Note**
495 -|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
496 -|O|O d.d|0.0~~255.15|
497 -|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
498 -|S|S d.d|0.0~~255.15|
499 -|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
500 -|(% rowspan="9" %)Word|S|S d|0~~255|
501 -|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
502 -|TP|TP nnhh|0~~ffff
503 -|CS|CS nnhh|0~~ffff
504 -|CP|CP nnhh|0~~ffff
505 -|N|N nnhh|0~~ffff
506 -|C|C nnhh|0~~ffff
507 -|T|T nnhh|0~~ffff
508 -|R|R nnhh|0~~ffff
509 -
510 -**Cable Wiring**
511 -
512 512  == **FreeTag Ethernet/IP (CompactLogix)** ==
513 513  
514 514  Allen-Brandly CompactLogix
... ... @@ -566,8 +566,43 @@
566 566  (% style="text-align:center" %)
567 567  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]]
568 568  
569 -== ==
532 +== **MicroLogix** ==
570 570  
534 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
535 +
536 +**HMI Settings**
537 +
538 +(% class="table-bordered" %)
539 +|**Item**|**Settings**|**Note**
540 +|Protocol|Allen-Bradlley MicroLogix|
541 +|Connection|RS232|
542 +|Baud rate|19200|
543 +|Data bit|8|
544 +|Parity|None|
545 +|Stop bit|1|
546 +|PLC station No.|1|
547 +
548 +**Address List**
549 +
550 +(% class="table-bordered" %)
551 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
552 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
553 +|O|O d.d|0.0~~255.15|
554 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
555 +|S|S d.d|0.0~~255.15|
556 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
557 +|(% rowspan="9" %)Word|S|S d|0~~255|
558 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
559 +|TP|TP nnhh|0~~ffff
560 +|CS|CS nnhh|0~~ffff
561 +|CP|CP nnhh|0~~ffff
562 +|N|N nnhh|0~~ffff
563 +|C|C nnhh|0~~ffff
564 +|T|T nnhh|0~~ffff
565 +|R|R nnhh|0~~ffff
566 +
567 +**Cable Wiring**
568 +
571 571  (% style="text-align:center" %)
572 572  [[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]]
573 573