... ... @@ -399,7 +399,6 @@
399 399  
400 400  (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
401 401  
402 -
403 403  **Software configuration of PLC**
404 404  
405 405  **1)PLC programming software**
... ... @@ -471,7 +471,6 @@
471 471  
472 472  = Create communication with **Rockwell PLC** =
473 473  
474 -
475 475  == **MicroLogix Protocol** ==
476 476  
477 477  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
... ... @@ -509,6 +509,10 @@
509 509  
510 510  **Cable Wiring**
511 511  
510 +
511 +(% style="text-align:center" %)
512 +[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]]
513 +
512 512  == **FreeTag Ethernet/IP (CompactLogix)** ==
513 513  
514 514  Allen-Brandly CompactLogix
... ... @@ -566,11 +566,6 @@
566 566  (% style="text-align:center" %)
567 567  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]]
568 568  
569 -== ==
570 -
571 -(% style="text-align:center" %)
572 -[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]]
573 -
574 574  == **AB PLC address edit** ==
575 575  
576 576  The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200.
... ... @@ -588,117 +588,280 @@
588 588  |(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15
589 589  |(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15
590 590  |(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15
591 -|(% style="width:393px" %)**PLC word address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range**
592 -|(% style="width:393px" %)S|(% style="width:350px" %)ddd|(% style="width:333px" %)S0 ~~ 255
593 -|(% style="width:393px" %)TS|(% style="width:350px" %)ffff|(% style="width:333px" %)TS0 ~~ FFFF
594 -|(% style="width:393px" %)TP|(% style="width:350px" %)ffff|(% style="width:333px" %)TP0 ~~ FFFF
595 -|(% style="width:393px" %)CS|(% style="width:350px" %)ffff|(% style="width:333px" %)CS0 ~~ FFFF
596 -|(% style="width:393px" %)CP|(% style="width:350px" %)ffff|(% style="width:333px" %)CP0 ~~ FFFF
597 -|(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF
598 -|(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF
588 +|**PLC word address type**|**Address format**|**Address range**
589 +|S|ddd|S0 ~~ 255
590 +|TS|ffff|TS0 ~~ FFFF
591 +|TP|ffff|TP0 ~~ FFFF
592 +|CS|ffff|CS0 ~~ FFFF
593 +|CP|ffff|CP0 ~~ FFFF
594 +|N|ffff|N0 ~~ FFFF
595 +|F|ffff|F0 ~~ FFFF
599 599  
600 -= **Barcode Scanner** =
597 += Create communication with (% id="cke_bm_43878S" style="display:none" %)** **(%%)**Siemens** =
601 601  
602 -Supported: DELI 14880 barcode scanner
599 +== **S7-200 Smart Ethernet Protocol** ==
603 603  
601 +Supported Series: Siemens S7-200 SMART Series Ethernet Module.
602 +
603 +Website: [[http:~~/~~/www.siemens.com/entry/cc/en/>>url:http://www.siemens.com/entry/cc/en/]]
604 +
604 604  **HMI Setting**
605 605  
606 606  (% class="table-bordered" %)
607 607  |**Items**|**Settings**|**Note**
608 -|Protocol|Barcode Scanner|
609 -|Connection|USB|
609 +|Protocol|Simens S7-200 Smart Ethernet|
610 +|Connection|Ethernet|
611 +|Port No.|102|
612 +|PLC station No.|2|
610 610  
611 -**Operating Procedures**
614 +**Address List**
612 612  
613 -Select [Barcode Scanner];
616 +(% class="table-bordered" %)
617 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
618 +|(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
619 +|Q|Q|Q ddddd.o|0.0~~99999.7|
620 +|V|VWbit|VWbit ddddd.o|0.0~~99999.7|
621 +|V|V|V ddddd.o|0.0~~99999.7|
622 +|M|M|M ddddd.o|0.0~~99999.7|
623 +|SM|SM|ddddd.o|0.0~~99999.7|
624 +|S|S|ddddd.o|0.0~~99999.7|Read only
625 +|T|T|ddddd|0~~99999|Timer state, read only
626 +|C|C|ddddd|0~~99999|Counter state, read only
627 +|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999|
628 +|Q|QW|QW ddddd|0~~99999|
629 +|AI|AIW|AIW ddddd|0~~99999|
630 +|AQ|VB|VB ddddd|0~~99999|
631 +|V|VW|VW ddddd|0~~99998|(((
632 +VW0=VB (0~~1)
614 614  
634 +VW2=VB (2~~3)
635 +
636 +Address value is a multiple of 2
637 +)))
638 +|V|VD|VD ddddd|0~~99998|(((
639 +VD0=VB (0~~3)
640 +
641 +VD2=VB (4~~7)
642 +
643 +Address value is a multiple of 4
644 +)))
645 +|M|MB|MB ddddd|0~~99999|
646 +|M|MW|MW ddddd|0~~99999|(((
647 +MW0=MB(0~~1)
648 +
649 +MW2=MB(2~~3)
650 +
651 +Address value is a multiple of 2
652 +)))
653 +|M|MD|MD ddddd|0~~99999|(((
654 +MD0=MB(0~~3)
655 +
656 +MD4=MB(4~~7)
657 +
658 +Address value is a multiple of 4
659 +)))
660 +|T|TW|TW ddddd|0~~99999|Value of timer
661 +|C|CW|CW ddddd|0~~99999|Value of counter
662 +|W|SW|SW ddddd|0~~99999|
663 +
664 +**Communication Settings**
665 +
666 +Enable HMI Ethernet in [Project Settings];
667 +
615 615  (% style="text-align:center" %)
616 -[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
669 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
617 617  
618 -Set address for receiving;
671 +Set PLC IP in [Device IP] settings;
619 619  
620 -Set correct length;
673 +(% style="text-align:center" %)
674 +[[image:12.PLC Protocol_html_70b0c4c2ee21b10d.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
621 621  
676 +* PLC IP Address: PLC IP
677 +* PLC pot No.: 102(fixed)
678 +* Network:TCP_Client_2N(fixed)
679 +
622 622  (% style="text-align:center" %)
623 -[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
681 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
624 624  
625 -**✎Note:**
683 +* Wait timeout: depend on actual network situation (more than 1500 ms)
626 626  
627 -* The protocol uploads the information acquired by the USB scanner to the HMI;
628 -* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
629 -* Recommended model: DELI 14880 barcode scanner;
685 +**Cable Wiring**
630 630  
631 -= **Hitachi EHV Series (Ethernet)** =
687 +(% style="text-align:center" %)
688 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
632 632  
633 -Supported series: Hitachi EHV series
690 +== **S7-300 Ethernet** ==
634 634  
635 -**HMI Settings**
692 +Supported Series: Siemens S7-300 series PLC
636 636  
694 +**HMI Setting**
695 +
637 637  (% class="table-bordered" %)
638 638  |**Items**|**Settings**|**Note**
639 -|Protocol|Hitachi EHV series|
698 +|Protocol|Simens S7-300 Ethernet|
640 640  |Connection|Ethernet|
641 -|Port No.|3004~~3007|
700 +|Port No.|102|
701 +|PLC station No.|2|Need to be same as the PLC setting
642 642  
643 643  **Address List**
644 644  
645 645  (% class="table-bordered" %)
646 -|**Type**|**Register**|**Range**|**Format**|**Note**
647 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
648 -|M|0 - 7FFF.f (Hex)|M HHHH.h|
649 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
650 -H1H2H3H4 Module main number
706 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
707 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
708 +|Q|Q|Q ddddd.o|0.0~~99999.7|
709 +|M|M|M ddddd.o|0.0~~99999.7|
710 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
711 +nn: block number;
651 651  
652 -H1: Remote number
713 +dddd: address;
714 +)))
715 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
716 +|Q|QW|QW ddddd|0~~99999|
717 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
718 +|MW|MW ddddd|0~~99999|(((
719 +MW0=MB(0~~1)
653 653  
654 -H2: Unit number
721 +MW2=MB(2~~3)
655 655  
656 -H3: Slot number
723 +Address value is a multiple of 2
724 +)))
725 +|MD|MD ddddd|0~~99999|(((
726 +MD0=MB(0~~3)
657 657  
658 -H4: Word number of Module
728 +MD4=MB(4~~7)
659 659  
660 -H Sub number of Module
730 +Address value is a multiple of 4
731 +)))
732 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
733 +nn: block number;
661 661  
662 -For example:X21.3
735 +dddd: address
736 +)))
737 +|DBxDBW|DBxDBW nndddd|0~~99999999
738 +|DBxDBD|DBxDBD nndddd|0~~99999999
663 663  
664 -Slot number 2
740 +**Communication Settings**
665 665  
666 -Word number of module is 1
742 +Enable HMI Ethernet in [Project Settings];
667 667  
668 -Bit number of module is 3
744 +(% style="text-align:center" %)
745 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
669 669  
670 -Remote number and unit number are 0
747 +Set PLC IP in [Device IP] settings;
748 +
749 +(% style="text-align:center" %)
750 +[[image:12.PLC Protocol_html_910b1a0aa9e2201c.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]]
751 +
752 +* PLC IP Address: PLC IP
753 +* PLC pot No.: 102(fixed)
754 +* Network:TCP_Client_2N(fixed)
755 +
756 +(% style="text-align:center" %)
757 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
758 +
759 +* Wait timeout: depend on actual network situation (more than 1500 ms)
760 +
761 +**Cable Wiring**
762 +
763 +(% style="text-align:center" %)
764 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
765 +
766 +== **S7-1200 Ethernet** ==
767 +
768 +Supported Series: Siemens S7-1200
769 +
770 +**HMI Setting**
771 +
772 +(% class="table-bordered" %)
773 +|**Items**|**Settings**|**Note**
774 +|Protocol|Siemens S7-1200|
775 +|Connection|Ethernet|
776 +|Port No.|102|
777 +|PLC station No.|2|
778 +
779 +**Address List**
780 +
781 +(% class="table-bordered" %)
782 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
783 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
784 +d:0~-~-9999
785 +
786 +o:0-7
787 +)))|
788 +|Q|Q|Q d.o|(((
789 +d:0~-~-9999
790 +
791 +o:0-7
792 +)))|
793 +|M|M|M d.o|(((
794 +d:0~-~-9999
795 +
796 +o:0-7
797 +)))|
798 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
799 +nn:0-9999,
800 +
801 +dddd:0-9999,
802 +
803 +o:0-7
804 +)))|(((
805 +nn:DB No.
806 +
807 +dddd:address value
808 +
809 +o: digit address
671 671  )))
672 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
673 -|R|0 – FF.f (Hex)|R HH.h|
674 -|L|0 - 73FF.f (Hex)|L HHHH.h|
675 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
676 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
677 -H1H2H3H4 Module main number
811 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
812 +|M|MW|MW d|d:0-99999|(((
813 +MW0=MB(0~~1)
678 678  
679 -H1: Remote number
815 +MW2=MB(2~~3)
680 680  
681 -H2: Unit number
817 +Address value is a multiple of 2
818 +)))
819 +|M|MD|MD d|d:0-99999|(((
820 +MD0=MB(0~~3)
682 682  
683 -H3: Slot number
822 +MD4=MB(4~~7)
684 684  
685 -H4: Word number of module
824 +Address value is a multiple of 4
825 +)))
826 +|I|IW|IW d|d:0-99999|
827 +|Q|QW|QW d|d:0-99999|
828 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
829 +nn:0-9999
686 686  
687 -For example:WX21
831 +dddd:0-9999
832 +)))|(((
833 +nn:DB No.
688 688  
689 -Word number of module is 1
835 +dddd:address value
836 +)))
837 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
838 +nn:0-9999
690 690  
691 -Slot number is 2
840 +dddd:0-9999
841 +)))|(((
842 +nn:DB No.
692 692  
693 -Remote number and unit number are 0
844 +dddd:address value
845 +
846 +Address value is a multiple of 2
694 694  )))
695 -|WY|0 – FFFF (Hex)|WY H1H2H3H4
696 -|WR|0 – FFFF (Hex)|WR HHHH|
697 -|WL|0 - 73FF (Hex)|WL HHHH|
698 -|TC|0 - 2559|TC DDDD|
848 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
849 +nn:0-9999
699 699  
700 -**Communication settings in HMI**
851 +dddd:0-9999
852 +)))|(((
853 +nn:DB No.
701 701  
855 +dddd:address value
856 +
857 +Address value is a multiple of 4
858 +)))
859 +
860 +**Communication Settings**
861 +
702 702  Enable HMI Ethernet in [Project Settings];
703 703  
704 704  (% style="text-align:center" %)
... ... @@ -707,178 +707,284 @@
707 707  Set PLC IP in [Device IP] settings;
708 708  
709 709  (% style="text-align:center" %)
710 -[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
870 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
711 711  
712 -**PLC Configuration**
872 +**✎Note:**
713 713  
714 -Connect with PLC, select[Online mode];
874 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
875 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
715 715  
716 -(% style="text-align:center" %)
717 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
877 +**PLC Settings**
718 718  
719 -Set IP address, it is the same LAN parameters with HMI;
879 +Add BD
720 720  
881 +* Please uncheck [Symbolic access only] option;
882 +
721 721  (% style="text-align:center" %)
722 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
884 +[[image:12.PLC Protocol_html_643144c591994418.png||data-xwiki-image-style-alignment="center" height="546" width="550" class="img-thumbnail"]]
723 723  
724 -3) Save PLC communication parameter, and restart PLC
886 +Address settings, using BD2 as example.
725 725  
726 -**PLC Monitor Mode**
888 +* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1.
889 +* 2 represent DB block number
890 +* xxxx represent address
727 727  
728 -Connect with PLC and choose to “online” mode
892 +**Such as:**
729 729  
894 +* DBxDBB20000 = DB2.DBB0
895 +* DBxDBW20004 = DB2.DBW4
896 +
730 730  (% style="text-align:center" %)
731 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
898 +[[image:12.PLC Protocol_html_87ceaea84d552e62.png||data-xwiki-image-style-alignment="center" height="245" width="537" class="img-thumbnail"]]
732 732  
733 -Open I/O monitor sheet1
900 +**How to connect with S7-1200 Firmware V4.0**
734 734  
735 -(% style="text-align:center" %)
736 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
902 +PLC configuration
737 737  
738 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
904 +* Double click [device configuration] in Siemens via software
905 +* Double click [protection] to enter protection configuration screen
739 739  
740 740  (% style="text-align:center" %)
741 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
908 +[[image:12.PLC Protocol_html_9779940d38da8e07.png||data-xwiki-image-style-alignment="center" height="426" width="341" class="img-thumbnail"]]
742 742  
743 -Enter the register address, click OK to view the value of the register.
910 +* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)]
744 744  
745 745  (% style="text-align:center" %)
746 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
913 +[[image:12.PLC Protocol_html_d2c667b02f9720b1.png||data-xwiki-image-style-alignment="center" height="296" width="554" class="img-thumbnail"]]
747 747  
748 -(% style="text-align:center" %)
749 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
915 +DB settings
750 750  
751 -**✎Note:**
917 +* Right click [DB], select [properties]
918 +* Uncheck [optimized block access]
752 752  
753 -* Both word registers and bit registers support even continuous read/write functions;
754 -* The range of registers is based on the specific PLC type;
755 -
756 756  **Cable Wiring**
757 757  
758 758  (% style="text-align:center" %)
759 759  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
760 760  
761 -= **IEC60870-5 104 Client** =
925 +== **S7-XXX Ethernet** ==
762 762  
927 +Supported Series: Siemens S7-400, S7-1200 and S7-1500
928 +
763 763  **HMI Setting**
764 764  
765 -(% class="table-bordered" %)
766 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
767 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
768 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
769 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
931 +(% class="table-bordered" style="width:823px" %)
932 +|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note**
933 +|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %)
934 +|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %)
935 +|Port No.|(% style="width:437px" %)102|(% style="width:201px" %)
936 +|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %)
937 +|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %)
770 770  
939 +Slot from TIA Portal is equal to Device No. of PIStudio
940 +
941 +Rack from TIA Portal is equal to HMI No. of PIStudio
942 +
943 +(% style="text-align:center" %)
944 +[[image:S7-XXXCommunication Settings.png]]
945 +
946 +(% style="text-align:center" %)
947 +[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]]
948 +
771 771  **Address List**
772 772  
773 773  (% class="table-bordered" %)
774 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
775 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
776 -|(% style="width:461px" %)SCNA|0~~16777215.7
777 -|(% style="width:461px" %)DPTB|0~~16777215.7
778 -|(% style="width:461px" %)DCNA|0~~16777215.7
779 -|(% style="width:461px" %)METF|0~~16777215.7
780 -|(% style="width:461px" %)SENC|0~~16777215.7
781 -|(% style="width:461px" %)SENA|0~~16777215.7
782 -|(% style="width:461px" %)MENA|0~~16777215.7
783 -|(% style="width:461px" %)METD|0~~16777215.7
784 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
785 -|(% style="width:461px" %)SCNA|0~~16777215
786 -|(% style="width:461px" %)DPTB|0~~16777215
787 -|(% style="width:461px" %)DCNA|0~~16777215
788 -|(% style="width:461px" %)SENA|0~~16777215
789 -|(% style="width:461px" %)MENA|0~~16777215
790 -|(% style="width:461px" %)METD|0~~16777215
791 -|(% style="width:461px" %)INRO|0~~16777215
792 -|(% style="width:461px" %)TIMESYN|0~~16777215
793 -|(% style="width:461px" %)TIMEZ|0~~16777215
794 -|(% style="width:461px" %)NTP|0~~16777215
795 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
796 -|(% style="width:461px" %)SENC|0~~16777215
952 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
953 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
954 +d:0~-~-9999
797 797  
798 -**Address Configuration**
956 +o:0-7
957 +)))|
958 +|Q|Q|Q d.o|(((
959 +d:0~-~-9999
799 799  
800 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
961 +o:0-7
962 +)))|
963 +|M|M|M d.o|(((
964 +d:0~-~-9999
801 801  
802 -(% style="text-align:center" %)
803 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
966 +o:0-7
967 +)))|
968 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
969 +nn:0-9999,
804 804  
805 -(% style="text-align:center" %)
806 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
971 +dddd:0-9999,
807 807  
808 -Extended tag name
973 +o:0-7
974 +)))|(((
975 +nn:DB No.
809 809  
810 -Address range for the extended tag.
977 +dddd:address value
811 811  
979 +o: digit address
980 +)))
981 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
982 +|M|MW|MW d|d:0-99999|(((
983 +MW0=MB(0~~1)
984 +
985 +MW2=MB(2~~3)
986 +
987 +Address value is a multiple of 2
988 +)))
989 +|M|MD|MD d|d:0-99999|(((
990 +MD0=MB(0~~3)
991 +
992 +MD4=MB(4~~7)
993 +
994 +Address value is a multiple of 4
995 +)))
996 +|I|IW|IW d|d:0-99999|
997 +|Q|QW|QW d|d:0-99999|
998 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
999 +nn:0-9999
1000 +
1001 +dddd:0-9999
1002 +)))|(((
1003 +nn:DB No.
1004 +
1005 +dddd:address value
1006 +)))
1007 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
1008 +nn:0-9999
1009 +
1010 +dddd:0-9999
1011 +)))|(((
1012 +nn:DB No.
1013 +
1014 +dddd:address value
1015 +
1016 +Address value is a multiple of 2
1017 +)))
1018 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
1019 +nn:0-9999
1020 +
1021 +dddd:0-9999
1022 +)))|(((
1023 +nn:DB No.
1024 +
1025 +dddd:address value
1026 +
1027 +Address value is a multiple of 4
1028 +)))
1029 +
812 812  **Communication Settings**
813 813  
814 814  Enable HMI Ethernet in [Project Settings];
815 815  
816 816  (% style="text-align:center" %)
817 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1035 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]]
818 818  
819 819  Set PLC IP in [Device IP] settings;
820 820  
821 821  (% style="text-align:center" %)
822 -[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
1040 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
823 823  
1042 +**✎Note:**
1043 +
1044 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
1045 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
1046 +
824 824  **Cable Wiring**
825 825  
826 -(% style="text-align:center" %)
827 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1049 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
828 828  
829 -= **LG XGK FEnet Ethernet** =
1051 +== (% id="cke_bm_25456S" style="display:none" %)** **(%%)**LOGO Ethernet** ==
830 830  
831 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
1053 +Supported Series: Siemens Logo 0BA0 series
832 832  
833 833  **HMI Settings**
834 834  
835 835  (% class="table-bordered" %)
836 836  |**Items**|**Settings**|**Note**
837 -|Protocol|LG XGK FEnet(Ethernet)|
1059 +|Protocol|Siemens LOGO|
838 838  |Connection|Ethernet|
839 -|Port No.|2004|
1061 +|Port No.|102|
1062 +|PLC station No.|2|
840 840  
841 841  **Address List**
842 842  
843 843  (% class="table-bordered" %)
844 -|**Type**|**Register**|**Range**|**Format**|**Note**
845 -|(% rowspan="14" %)Word|P|0~~2047|P d|
846 -|M|0~~2047|M d|
847 -|K|0~~2047|K d|
848 -|F|0~~2047|F d|
849 -|T|0~~2047|T d|
850 -|C|0~~2047|C d|
851 -|Z|0~~127|Z d|
852 -|S|0~~127|S d|
853 -|L|0~~11263|L d|
854 -|N|0~~21503|N d|
855 -|D|0~~32767|D d|
856 -|R|0~~32767|R d|
857 -|ZR|0~~65535|ZR d|
858 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
1067 +|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
1068 +|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
1069 +|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
1070 +|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
1071 +|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
1072 +|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
1073 +|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
1074 +|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
1075 +|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
1076 +|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
1077 +|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
1078 +|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
1079 +|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
1080 +|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
1081 +|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
1082 +|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
859 859  
860 -**✎Note:**
1084 +**PLC Settings in LOGO Software:**
861 861  
862 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
863 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
864 -* All bit registers are in the form of bits in word, and the range is the same as the word register;
1086 +Click [Tools]~-~-[Ethernet Connections],shown as below.
865 865  
866 -**Communication settings in HMI**
1088 +(% style="text-align:center" %)
1089 +[[image:12.PLC Protocol_html_8b9d2322edf89519.png||data-xwiki-image-style-alignment="center" height="641" width="423" class="img-thumbnail"]]
867 867  
868 -Enable HMI Ethernet in [Project Settings];
1091 +Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
869 869  
870 870  (% style="text-align:center" %)
871 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1094 +[[image:12.PLC Protocol_html_6c4dd041b26cd8a1.png||data-xwiki-image-style-alignment="center" height="481" width="363" class="img-thumbnail"]]
872 872  
1096 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
1097 +
1098 +(% style="text-align:center" %)
1099 +[[image:12.PLC Protocol_html_7af2611d3790a77d.png||data-xwiki-image-style-alignment="center" height="359" width="426" class="img-thumbnail"]]
1100 +
1101 +**Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
1102 +
1103 +(% style="text-align:center" %)
1104 +[[image:12.PLC Protocol_html_3243e4cd600595cc.png||data-xwiki-image-style-alignment="center" height="368" width="554" class="img-thumbnail"]]
1105 +
1106 +
1107 +(% style="text-align:center" %)
1108 +[[image:12.PLC Protocol_html_cb1d92e2cc91a8db.png||data-xwiki-image-style-alignment="center" height="320" width="553" class="img-thumbnail"]]
1109 +
1110 +
1111 +**HMI Communication Settings**
1112 +
873 873  Set PLC IP in [Device IP] settings;
874 874  
875 875  (% style="text-align:center" %)
876 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
1116 +[[image:SiemensLOGODeviceIP.png]]
877 877  
1118 +Enable HMI Ethernet in [Project Settings];
1119 +
1120 +(% style="text-align:center" %)
1121 +[[image:12.PLC Protocol_html_95917a3d92068467.png||data-xwiki-image-style-alignment="center" height="311" width="553" class="img-thumbnail"]]
1122 +
1123 +TSAP setting
1124 +
1125 +* Regarding the setting of PLC TSAP, HMI provides system special address for setting, it is recommended to run in HMI script initialization, write PLC TSAP to corresponding system special register.
1126 +* HSW10118 = local TSAP of HMI, this is remote TSAP of PLC.
1127 +* HSW10119 = Remote TSAP of HMI, this is local TSAP of PLC.
1128 +
1129 +**✎Note:**
1130 +
1131 +* The data of TSAP is hexadecimal format. For example: the remote TSAP configured in the PLC is set to 20.00, then HSW10118 should be set to 0x2000, that is, HSW10118 = 8192.
1132 +
1133 +(% style="text-align:center" %)
1134 +[[image:12.PLC Protocol_html_5c6374b21f46e01e.png||data-xwiki-image-style-alignment="center" height="139" width="498" class="img-thumbnail"]]
1135 +
1136 +
1137 +* AI word address and Ibit address are read-only and cannot be written on HMI.
1138 +* VW address should be even number.such as VW0, VW2, VW4...
1139 +* VD address it takes two VW addresses.such as VD0,VD4,VD8...
1140 +* Written value of RTC cannot exceed 255.
1141 +
878 878  **Cable Wiring**
879 879  
880 -= **Mitsubishi** =
1144 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
881 881  
1146 += Create communication with **Mitsubishi** =
1147 +
882 882  == **FX1S, 1N, 2N Series** ==
883 883  
884 884  Supported Series: Mitsubishi FX1S, FX1N, FX2N series
... ... @@ -2650,8 +2650,6 @@
2650 2650  
2651 2651  **✎Note:** COM3 only available in PI8000/PI9000 series.
2652 2652  
2653 -= =
2654 -
2655 2655  = **Printer** =
2656 2656  
2657 2657  == **TSPL label printer** ==
... ... @@ -2852,3 +2852,284 @@
2852 2852  
2853 2853  (% style="text-align:center" %)
2854 2854  [[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]]
3119 +
3120 += **Barcode Scanner** =
3121 +
3122 +Supported: DELI 14880 barcode scanner
3123 +
3124 +**HMI Setting**
3125 +
3126 +|**Items**|**Settings**|**Note**
3127 +|Protocol|Barcode Scanner|
3128 +|Connection|USB|
3129 +
3130 +**Operating Procedures**
3131 +
3132 +Select [Barcode Scanner];
3133 +
3134 +(% style="text-align:center" %)
3135 +[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
3136 +
3137 +Set address for receiving;
3138 +
3139 +Set correct length;
3140 +
3141 +(% style="text-align:center" %)
3142 +[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
3143 +
3144 +**✎Note:**
3145 +
3146 +* The protocol uploads the information acquired by the USB scanner to the HMI;
3147 +* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
3148 +* Recommended model: DELI 14880 barcode scanner;
3149 +
3150 += **Hitachi EHV Series (Ethernet)** =
3151 +
3152 +Supported series: Hitachi EHV series
3153 +
3154 +**HMI Settings**
3155 +
3156 +(% class="table-bordered" %)
3157 +|**Items**|**Settings**|**Note**
3158 +|Protocol|Hitachi EHV series|
3159 +|Connection|Ethernet|
3160 +|Port No.|3004~~3007|
3161 +
3162 +**Address List**
3163 +
3164 +(% class="table-bordered" %)
3165 +|**Type**|**Register**|**Range**|**Format**|**Note**
3166 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
3167 +|M|0 - 7FFF.f (Hex)|M HHHH.h|
3168 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
3169 +H1H2H3H4 Module main number
3170 +
3171 +H1: Remote number
3172 +
3173 +H2: Unit number
3174 +
3175 +H3: Slot number
3176 +
3177 +H4: Word number of Module
3178 +
3179 +H Sub number of Module
3180 +
3181 +For example:X21.3
3182 +
3183 +Slot number 2
3184 +
3185 +Word number of module is 1
3186 +
3187 +Bit number of module is 3
3188 +
3189 +Remote number and unit number are 0
3190 +)))
3191 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
3192 +|R|0 – FF.f (Hex)|R HH.h|
3193 +|L|0 - 73FF.f (Hex)|L HHHH.h|
3194 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
3195 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
3196 +H1H2H3H4 Module main number
3197 +
3198 +H1: Remote number
3199 +
3200 +H2: Unit number
3201 +
3202 +H3: Slot number
3203 +
3204 +H4: Word number of module
3205 +
3206 +For example:WX21
3207 +
3208 +Word number of module is 1
3209 +
3210 +Slot number is 2
3211 +
3212 +Remote number and unit number are 0
3213 +)))
3214 +|WY|0 – FFFF (Hex)|WY H1H2H3H4
3215 +|WR|0 – FFFF (Hex)|WR HHHH|
3216 +|WL|0 - 73FF (Hex)|WL HHHH|
3217 +|TC|0 - 2559|TC DDDD|
3218 +
3219 +**Communication settings in HMI**
3220 +
3221 +Enable HMI Ethernet in [Project Settings];
3222 +
3223 +(% style="text-align:center" %)
3224 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
3225 +
3226 +Set PLC IP in [Device IP] settings;
3227 +
3228 +(% style="text-align:center" %)
3229 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
3230 +
3231 +**PLC Configuration**
3232 +
3233 +Connect with PLC, select[Online mode];
3234 +
3235 +(% style="text-align:center" %)
3236 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
3237 +
3238 +Set IP address, it is the same LAN parameters with HMI;
3239 +
3240 +(% style="text-align:center" %)
3241 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
3242 +
3243 +3) Save PLC communication parameter, and restart PLC
3244 +
3245 +**PLC Monitor Mode**
3246 +
3247 +Connect with PLC and choose to “online” mode
3248 +
3249 +(% style="text-align:center" %)
3250 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
3251 +
3252 +Open I/O monitor sheet1
3253 +
3254 +(% style="text-align:center" %)
3255 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
3256 +
3257 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
3258 +
3259 +(% style="text-align:center" %)
3260 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
3261 +
3262 +Enter the register address, click OK to view the value of the register.
3263 +
3264 +(% style="text-align:center" %)
3265 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
3266 +
3267 +(% style="text-align:center" %)
3268 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
3269 +
3270 +**✎Note:**
3271 +
3272 +* Both word registers and bit registers support even continuous read/write functions;
3273 +* The range of registers is based on the specific PLC type;
3274 +
3275 +**Cable Wiring**
3276 +
3277 +(% style="text-align:center" %)
3278 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
3279 +
3280 += **IEC60870-5 104 Client** =
3281 +
3282 +**HMI Setting**
3283 +
3284 +(% class="table-bordered" %)
3285 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
3286 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
3287 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
3288 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
3289 +
3290 +**Address List**
3291 +
3292 +(% class="table-bordered" %)
3293 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
3294 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
3295 +|(% style="width:461px" %)SCNA|0~~16777215.7
3296 +|(% style="width:461px" %)DPTB|0~~16777215.7
3297 +|(% style="width:461px" %)DCNA|0~~16777215.7
3298 +|(% style="width:461px" %)METF|0~~16777215.7
3299 +|(% style="width:461px" %)SENC|0~~16777215.7
3300 +|(% style="width:461px" %)SENA|0~~16777215.7
3301 +|(% style="width:461px" %)MENA|0~~16777215.7
3302 +|(% style="width:461px" %)METD|0~~16777215.7
3303 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
3304 +|(% style="width:461px" %)SCNA|0~~16777215
3305 +|(% style="width:461px" %)DPTB|0~~16777215
3306 +|(% style="width:461px" %)DCNA|0~~16777215
3307 +|(% style="width:461px" %)SENA|0~~16777215
3308 +|(% style="width:461px" %)MENA|0~~16777215
3309 +|(% style="width:461px" %)METD|0~~16777215
3310 +|(% style="width:461px" %)INRO|0~~16777215
3311 +|(% style="width:461px" %)TIMESYN|0~~16777215
3312 +|(% style="width:461px" %)TIMEZ|0~~16777215
3313 +|(% style="width:461px" %)NTP|0~~16777215
3314 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
3315 +|(% style="width:461px" %)SENC|0~~16777215
3316 +
3317 +**Address Configuration**
3318 +
3319 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
3320 +
3321 +(% style="text-align:center" %)
3322 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
3323 +
3324 +(% style="text-align:center" %)
3325 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
3326 +
3327 +Extended tag name
3328 +
3329 +Address range for the extended tag.
3330 +
3331 +**Communication Settings**
3332 +
3333 +Enable HMI Ethernet in [Project Settings];
3334 +
3335 +(% style="text-align:center" %)
3336 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
3337 +
3338 +Set PLC IP in [Device IP] settings;
3339 +
3340 +(% style="text-align:center" %)
3341 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
3342 +
3343 +**Cable Wiring**
3344 +
3345 +(% style="text-align:center" %)
3346 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
3347 +
3348 += **LG XGK FEnet Ethernet** =
3349 +
3350 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
3351 +
3352 +**HMI Settings**
3353 +
3354 +(% class="table-bordered" %)
3355 +|**Items**|**Settings**|**Note**
3356 +|Protocol|LG XGK FEnet(Ethernet)|
3357 +|Connection|Ethernet|
3358 +|Port No.|2004|
3359 +
3360 +**Address List**
3361 +
3362 +(% class="table-bordered" %)
3363 +|**Type**|**Register**|**Range**|**Format**|**Note**
3364 +|(% rowspan="14" %)Word|P|0~~2047|P d|
3365 +|M|0~~2047|M d|
3366 +|K|0~~2047|K d|
3367 +|F|0~~2047|F d|
3368 +|T|0~~2047|T d|
3369 +|C|0~~2047|C d|
3370 +|Z|0~~127|Z d|
3371 +|S|0~~127|S d|
3372 +|L|0~~11263|L d|
3373 +|N|0~~21503|N d|
3374 +|D|0~~32767|D d|
3375 +|R|0~~32767|R d|
3376 +|ZR|0~~65535|ZR d|
3377 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
3378 +
3379 +**✎Note:**
3380 +
3381 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
3382 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
3383 +* All bit registers are in the form of bits in word, and the range is the same as the word register;
3384 +
3385 +**Communication settings in HMI**
3386 +
3387 +Enable HMI Ethernet in [Project Settings];
3388 +
3389 +(% style="text-align:center" %)
3390 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
3391 +
3392 +Set PLC IP in [Device IP] settings;
3393 +
3394 +(% style="text-align:center" %)
3395 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
3396 +