Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -87,7 +87,6 @@ 87 87 88 88 = Create communication with WECON PLC = 89 89 90 -== **LX3V Serial Protocol** == 91 91 92 92 Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 93 93 ... ... @@ -141,8 +141,7 @@ 141 141 142 142 [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 143 143 144 -(% class="wikigeneratedid" id="HHMIsettings" %) 145 -**HMI settings** 143 +== HMI settings == 146 146 147 147 **Download PIStudio Software** 148 148 ... ... @@ -231,8 +231,7 @@ 231 231 * HMI setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/>>https://docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/]] 232 232 * PLC setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/>>https://docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/]] 233 233 234 -(% class="wikigeneratedid" id="HPLCsettings" %) 235 -**PLC settings** 232 +== PLC settings == 236 236 237 237 **Download PLC Software** 238 238 ... ... @@ -317,8 +317,12 @@ 317 317 (% style="text-align:center" %) 318 318 [[image:image-20220819105928-9.png||height="229" width="669"]] 319 319 320 -= =**LX5V SerialProtocol** ==317 += **WECON PLC** = 321 321 319 + 320 + 321 +== **HMI and Wecon LX5V serial communication** == 322 + 322 322 This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 323 323 324 324 **Software configuration of PLC** ... ... @@ -395,7 +395,7 @@ 395 395 396 396 The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 397 397 398 -== **LX5V-N Ethernet protocol** ==399 +== **HMI and Wecon LX5V-N Ethernet communication** == 399 399 400 400 (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 401 401 ... ... @@ -469,50 +469,10 @@ 469 469 470 470 The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 471 471 472 -= Createcommunicationwith **Rockwell PLC**=473 += = 473 473 475 += **Allen-Bradley** = 474 474 475 -== **MicroLogix Protocol** == 476 - 477 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 478 - 479 -**HMI Settings** 480 - 481 -(% class="table-bordered" %) 482 -|**Item**|**Settings**|**Note** 483 -|Protocol|Allen-Bradlley MicroLogix| 484 -|Connection|RS232| 485 -|Baud rate|19200| 486 -|Data bit|8| 487 -|Parity|None| 488 -|Stop bit|1| 489 -|PLC station No.|1| 490 - 491 -**Address List** 492 - 493 -(% class="table-bordered" %) 494 -|**Type**|**Device registers**|**Format**|**Range**|**Note** 495 -|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 496 -|O|O d.d|0.0~~255.15| 497 -|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 498 -|S|S d.d|0.0~~255.15| 499 -|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 500 -|(% rowspan="9" %)Word|S|S d|0~~255| 501 -|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 502 -|TP|TP nnhh|0~~ffff 503 -|CS|CS nnhh|0~~ffff 504 -|CP|CP nnhh|0~~ffff 505 -|N|N nnhh|0~~ffff 506 -|C|C nnhh|0~~ffff 507 -|T|T nnhh|0~~ffff 508 -|R|R nnhh|0~~ffff 509 - 510 -**Cable Wiring** 511 - 512 - 513 -(% style="text-align:center" %) 514 -[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]] 515 - 516 516 == **FreeTag Ethernet/IP (CompactLogix)** == 517 517 518 518 Allen-Brandly CompactLogix ... ... @@ -570,6 +570,46 @@ 570 570 (% style="text-align:center" %) 571 571 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]] 572 572 534 +== **MicroLogix** == 535 + 536 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 537 + 538 +**HMI Settings** 539 + 540 +(% class="table-bordered" %) 541 +|**Item**|**Settings**|**Note** 542 +|Protocol|Allen-Bradlley MicroLogix| 543 +|Connection|RS232| 544 +|Baud rate|19200| 545 +|Data bit|8| 546 +|Parity|None| 547 +|Stop bit|1| 548 +|PLC station No.|1| 549 + 550 +**Address List** 551 + 552 +(% class="table-bordered" %) 553 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 554 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 555 +|O|O d.d|0.0~~255.15| 556 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 557 +|S|S d.d|0.0~~255.15| 558 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 559 +|(% rowspan="9" %)Word|S|S d|0~~255| 560 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 561 +|TP|TP nnhh|0~~ffff 562 +|CS|CS nnhh|0~~ffff 563 +|CP|CP nnhh|0~~ffff 564 +|N|N nnhh|0~~ffff 565 +|C|C nnhh|0~~ffff 566 +|T|T nnhh|0~~ffff 567 +|R|R nnhh|0~~ffff 568 + 569 +**Cable Wiring** 570 + 571 +(% style="text-align:center" %) 572 +[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]] 573 + 573 573 == **AB PLC address edit** == 574 574 575 575 The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200.