Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -596,37 +596,6 @@ 596 596 |(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF 597 597 |(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF 598 598 599 -= **Barcode Scanner** = 600 - 601 -Supported: DELI 14880 barcode scanner 602 - 603 -**HMI Setting** 604 - 605 -(% class="table-bordered" %) 606 -|**Items**|**Settings**|**Note** 607 -|Protocol|Barcode Scanner| 608 -|Connection|USB| 609 - 610 -**Operating Procedures** 611 - 612 -Select [Barcode Scanner]; 613 - 614 -(% style="text-align:center" %) 615 -[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]] 616 - 617 -Set address for receiving; 618 - 619 -Set correct length; 620 - 621 -(% style="text-align:center" %) 622 -[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]] 623 - 624 -**✎Note:** 625 - 626 -* The protocol uploads the information acquired by the USB scanner to the HMI; 627 -* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 628 -* Recommended model: DELI 14880 barcode scanner; 629 - 630 630 = **Hitachi EHV Series (Ethernet)** = 631 631 632 632 Supported series: Hitachi EHV series ... ... @@ -2851,3 +2851,33 @@ 2851 2851 2852 2852 (% style="text-align:center" %) 2853 2853 [[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]] 2823 + 2824 += **Barcode Scanner** = 2825 + 2826 +Supported: DELI 14880 barcode scanner 2827 + 2828 +**HMI Setting** 2829 + 2830 +|**Items**|**Settings**|**Note** 2831 +|Protocol|Barcode Scanner| 2832 +|Connection|USB| 2833 + 2834 +**Operating Procedures** 2835 + 2836 +Select [Barcode Scanner]; 2837 + 2838 +(% style="text-align:center" %) 2839 +[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]] 2840 + 2841 +Set address for receiving; 2842 + 2843 +Set correct length; 2844 + 2845 +(% style="text-align:center" %) 2846 +[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]] 2847 + 2848 +**✎Note:** 2849 + 2850 +* The protocol uploads the information acquired by the USB scanner to the HMI; 2851 +* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 2852 +* Recommended model: DELI 14880 barcode scanner;