399 399  
400 400  (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
401 401  
402 -
403 403  **Software configuration of PLC**
404 404  
405 405  **1)PLC programming software**
... ... @@ -471,7 +471,6 @@
471 471  
472 472  = Create communication with **Rockwell PLC** =
473 473  
474 -
475 475  == **MicroLogix Protocol** ==
476 476  
477 477  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
... ... @@ -587,117 +587,280 @@
587 587  |(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15
588 588  |(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15
589 589  |(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15
590 -|(% style="width:393px" %)**PLC word address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range**
591 -|(% style="width:393px" %)S|(% style="width:350px" %)ddd|(% style="width:333px" %)S0 ~~ 255
592 -|(% style="width:393px" %)TS|(% style="width:350px" %)ffff|(% style="width:333px" %)TS0 ~~ FFFF
593 -|(% style="width:393px" %)TP|(% style="width:350px" %)ffff|(% style="width:333px" %)TP0 ~~ FFFF
594 -|(% style="width:393px" %)CS|(% style="width:350px" %)ffff|(% style="width:333px" %)CS0 ~~ FFFF
595 -|(% style="width:393px" %)CP|(% style="width:350px" %)ffff|(% style="width:333px" %)CP0 ~~ FFFF
596 -|(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF
597 -|(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF
588 +|**PLC word address type**|**Address format**|**Address range**
589 +|S|ddd|S0 ~~ 255
590 +|TS|ffff|TS0 ~~ FFFF
591 +|TP|ffff|TP0 ~~ FFFF
592 +|CS|ffff|CS0 ~~ FFFF
593 +|CP|ffff|CP0 ~~ FFFF
594 +|N|ffff|N0 ~~ FFFF
595 +|F|ffff|F0 ~~ FFFF
598 598  
599 -= **Barcode Scanner** =
597 += Create communication with (% id="cke_bm_43878S" style="display:none" %)** **(%%)**Siemens** =
600 600  
601 -Supported: DELI 14880 barcode scanner
599 +== **S7-200 Smart Ethernet Protocol** ==
602 602  
601 +Supported Series: Siemens S7-200 SMART Series Ethernet Module.
602 +
603 +Website: [[http:~~/~~/www.siemens.com/entry/cc/en/>>url:http://www.siemens.com/entry/cc/en/]]
604 +
603 603  **HMI Setting**
604 604  
605 605  (% class="table-bordered" %)
606 606  |**Items**|**Settings**|**Note**
607 -|Protocol|Barcode Scanner|
608 -|Connection|USB|
609 +|Protocol|Simens S7-200 Smart Ethernet|
610 +|Connection|Ethernet|
611 +|Port No.|102|
612 +|PLC station No.|2|
609 609  
610 -**Operating Procedures**
614 +**Address List**
611 611  
612 -Select [Barcode Scanner];
616 +(% class="table-bordered" %)
617 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
618 +|(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
619 +|Q|Q|Q ddddd.o|0.0~~99999.7|
620 +|V|VWbit|VWbit ddddd.o|0.0~~99999.7|
621 +|V|V|V ddddd.o|0.0~~99999.7|
622 +|M|M|M ddddd.o|0.0~~99999.7|
623 +|SM|SM|ddddd.o|0.0~~99999.7|
624 +|S|S|ddddd.o|0.0~~99999.7|Read only
625 +|T|T|ddddd|0~~99999|Timer state, read only
626 +|C|C|ddddd|0~~99999|Counter state, read only
627 +|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999|
628 +|Q|QW|QW ddddd|0~~99999|
629 +|AI|AIW|AIW ddddd|0~~99999|
630 +|AQ|VB|VB ddddd|0~~99999|
631 +|V|VW|VW ddddd|0~~99998|(((
632 +VW0=VB (0~~1)
613 613  
634 +VW2=VB (2~~3)
635 +
636 +Address value is a multiple of 2
637 +)))
638 +|V|VD|VD ddddd|0~~99998|(((
639 +VD0=VB (0~~3)
640 +
641 +VD2=VB (4~~7)
642 +
643 +Address value is a multiple of 4
644 +)))
645 +|M|MB|MB ddddd|0~~99999|
646 +|M|MW|MW ddddd|0~~99999|(((
647 +MW0=MB(0~~1)
648 +
649 +MW2=MB(2~~3)
650 +
651 +Address value is a multiple of 2
652 +)))
653 +|M|MD|MD ddddd|0~~99999|(((
654 +MD0=MB(0~~3)
655 +
656 +MD4=MB(4~~7)
657 +
658 +Address value is a multiple of 4
659 +)))
660 +|T|TW|TW ddddd|0~~99999|Value of timer
661 +|C|CW|CW ddddd|0~~99999|Value of counter
662 +|W|SW|SW ddddd|0~~99999|
663 +
664 +**Communication Settings**
665 +
666 +Enable HMI Ethernet in [Project Settings];
667 +
614 614  (% style="text-align:center" %)
615 -[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
669 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
616 616  
617 -Set address for receiving;
671 +Set PLC IP in [Device IP] settings;
618 618  
619 -Set correct length;
673 +(% style="text-align:center" %)
674 +[[image:12.PLC Protocol_html_70b0c4c2ee21b10d.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
620 620  
676 +* PLC IP Address: PLC IP
677 +* PLC pot No.: 102(fixed)
678 +* Network:TCP_Client_2N(fixed)
679 +
621 621  (% style="text-align:center" %)
622 -[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
681 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
623 623  
624 -**✎Note:**
683 +* Wait timeout: depend on actual network situation (more than 1500 ms)
625 625  
626 -* The protocol uploads the information acquired by the USB scanner to the HMI;
627 -* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
628 -* Recommended model: DELI 14880 barcode scanner;
685 +**Cable Wiring**
629 629  
630 -= **Hitachi EHV Series (Ethernet)** =
687 +(% style="text-align:center" %)
688 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
631 631  
632 -Supported series: Hitachi EHV series
690 +== **S7-300 Ethernet** ==
633 633  
634 -**HMI Settings**
692 +Supported Series: Siemens S7-300 series PLC
635 635  
694 +**HMI Setting**
695 +
636 636  (% class="table-bordered" %)
637 637  |**Items**|**Settings**|**Note**
638 -|Protocol|Hitachi EHV series|
698 +|Protocol|Simens S7-300 Ethernet|
639 639  |Connection|Ethernet|
640 -|Port No.|3004~~3007|
700 +|Port No.|102|
701 +|PLC station No.|2|Need to be same as the PLC setting
641 641  
642 642  **Address List**
643 643  
644 644  (% class="table-bordered" %)
645 -|**Type**|**Register**|**Range**|**Format**|**Note**
646 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
647 -|M|0 - 7FFF.f (Hex)|M HHHH.h|
648 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
649 -H1H2H3H4 Module main number
706 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
707 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
708 +|Q|Q|Q ddddd.o|0.0~~99999.7|
709 +|M|M|M ddddd.o|0.0~~99999.7|
710 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
711 +nn: block number;
650 650  
651 -H1: Remote number
713 +dddd: address;
714 +)))
715 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
716 +|Q|QW|QW ddddd|0~~99999|
717 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
718 +|MW|MW ddddd|0~~99999|(((
719 +MW0=MB(0~~1)
652 652  
653 -H2: Unit number
721 +MW2=MB(2~~3)
654 654  
655 -H3: Slot number
723 +Address value is a multiple of 2
724 +)))
725 +|MD|MD ddddd|0~~99999|(((
726 +MD0=MB(0~~3)
656 656  
657 -H4: Word number of Module
728 +MD4=MB(4~~7)
658 658  
659 -H Sub number of Module
730 +Address value is a multiple of 4
731 +)))
732 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
733 +nn: block number;
660 660  
661 -For example:X21.3
735 +dddd: address
736 +)))
737 +|DBxDBW|DBxDBW nndddd|0~~99999999
738 +|DBxDBD|DBxDBD nndddd|0~~99999999
662 662  
663 -Slot number 2
740 +**Communication Settings**
664 664  
665 -Word number of module is 1
742 +Enable HMI Ethernet in [Project Settings];
666 666  
667 -Bit number of module is 3
744 +(% style="text-align:center" %)
745 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
668 668  
669 -Remote number and unit number are 0
747 +Set PLC IP in [Device IP] settings;
748 +
749 +(% style="text-align:center" %)
750 +[[image:12.PLC Protocol_html_910b1a0aa9e2201c.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]]
751 +
752 +* PLC IP Address: PLC IP
753 +* PLC pot No.: 102(fixed)
754 +* Network:TCP_Client_2N(fixed)
755 +
756 +(% style="text-align:center" %)
757 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
758 +
759 +* Wait timeout: depend on actual network situation (more than 1500 ms)
760 +
761 +**Cable Wiring**
762 +
763 +(% style="text-align:center" %)
764 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
765 +
766 +== **S7-1200 Ethernet** ==
767 +
768 +Supported Series: Siemens S7-1200
769 +
770 +**HMI Setting**
771 +
772 +(% class="table-bordered" %)
773 +|**Items**|**Settings**|**Note**
774 +|Protocol|Siemens S7-1200|
775 +|Connection|Ethernet|
776 +|Port No.|102|
777 +|PLC station No.|2|
778 +
779 +**Address List**
780 +
781 +(% class="table-bordered" %)
782 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
783 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
784 +d:0~-~-9999
785 +
786 +o:0-7
787 +)))|
788 +|Q|Q|Q d.o|(((
789 +d:0~-~-9999
790 +
791 +o:0-7
792 +)))|
793 +|M|M|M d.o|(((
794 +d:0~-~-9999
795 +
796 +o:0-7
797 +)))|
798 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
799 +nn:0-9999,
800 +
801 +dddd:0-9999,
802 +
803 +o:0-7
804 +)))|(((
805 +nn:DB No.
806 +
807 +dddd:address value
808 +
809 +o: digit address
670 670  )))
671 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
672 -|R|0 – FF.f (Hex)|R HH.h|
673 -|L|0 - 73FF.f (Hex)|L HHHH.h|
674 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
675 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
676 -H1H2H3H4 Module main number
811 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
812 +|M|MW|MW d|d:0-99999|(((
813 +MW0=MB(0~~1)
677 677  
678 -H1: Remote number
815 +MW2=MB(2~~3)
679 679  
680 -H2: Unit number
817 +Address value is a multiple of 2
818 +)))
819 +|M|MD|MD d|d:0-99999|(((
820 +MD0=MB(0~~3)
681 681  
682 -H3: Slot number
822 +MD4=MB(4~~7)
683 683  
684 -H4: Word number of module
824 +Address value is a multiple of 4
825 +)))
826 +|I|IW|IW d|d:0-99999|
827 +|Q|QW|QW d|d:0-99999|
828 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
829 +nn:0-9999
685 685  
686 -For example:WX21
831 +dddd:0-9999
832 +)))|(((
833 +nn:DB No.
687 687  
688 -Word number of module is 1
835 +dddd:address value
836 +)))
837 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
838 +nn:0-9999
689 689  
690 -Slot number is 2
840 +dddd:0-9999
841 +)))|(((
842 +nn:DB No.
691 691  
692 -Remote number and unit number are 0
844 +dddd:address value
845 +
846 +Address value is a multiple of 2
693 693  )))
694 -|WY|0 – FFFF (Hex)|WY H1H2H3H4
695 -|WR|0 – FFFF (Hex)|WR HHHH|
696 -|WL|0 - 73FF (Hex)|WL HHHH|
697 -|TC|0 - 2559|TC DDDD|
848 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
849 +nn:0-9999
698 698  
699 -**Communication settings in HMI**
851 +dddd:0-9999
852 +)))|(((
853 +nn:DB No.
700 700  
855 +dddd:address value
856 +
857 +Address value is a multiple of 4
858 +)))
859 +
860 +**Communication Settings**
861 +
701 701  Enable HMI Ethernet in [Project Settings];
702 702  
703 703  (% style="text-align:center" %)
... ... @@ -706,178 +706,284 @@
706 706  Set PLC IP in [Device IP] settings;
707 707  
708 708  (% style="text-align:center" %)
709 -[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
870 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
710 710  
711 -**PLC Configuration**
872 +**✎Note:**
712 712  
713 -Connect with PLC, select[Online mode];
874 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
875 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
714 714  
715 -(% style="text-align:center" %)
716 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
877 +**PLC Settings**
717 717  
718 -Set IP address, it is the same LAN parameters with HMI;
879 +Add BD
719 719  
881 +* Please uncheck [Symbolic access only] option;
882 +
720 720  (% style="text-align:center" %)
721 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
884 +[[image:12.PLC Protocol_html_643144c591994418.png||data-xwiki-image-style-alignment="center" height="546" width="550" class="img-thumbnail"]]
722 722  
723 -3) Save PLC communication parameter, and restart PLC
886 +Address settings, using BD2 as example.
724 724  
725 -**PLC Monitor Mode**
888 +* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1.
889 +* 2 represent DB block number
890 +* xxxx represent address
726 726  
727 -Connect with PLC and choose to “online” mode
892 +**Such as:**
728 728  
894 +* DBxDBB20000 = DB2.DBB0
895 +* DBxDBW20004 = DB2.DBW4
896 +
729 729  (% style="text-align:center" %)
730 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
898 +[[image:12.PLC Protocol_html_87ceaea84d552e62.png||data-xwiki-image-style-alignment="center" height="245" width="537" class="img-thumbnail"]]
731 731  
732 -Open I/O monitor sheet1
900 +**How to connect with S7-1200 Firmware V4.0**
733 733  
734 -(% style="text-align:center" %)
735 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
902 +PLC configuration
736 736  
737 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
904 +* Double click [device configuration] in Siemens via software
905 +* Double click [protection] to enter protection configuration screen
738 738  
739 739  (% style="text-align:center" %)
740 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
908 +[[image:12.PLC Protocol_html_9779940d38da8e07.png||data-xwiki-image-style-alignment="center" height="426" width="341" class="img-thumbnail"]]
741 741  
742 -Enter the register address, click OK to view the value of the register.
910 +* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)]
743 743  
744 744  (% style="text-align:center" %)
745 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
913 +[[image:12.PLC Protocol_html_d2c667b02f9720b1.png||data-xwiki-image-style-alignment="center" height="296" width="554" class="img-thumbnail"]]
746 746  
747 -(% style="text-align:center" %)
748 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
915 +DB settings
749 749  
750 -**✎Note:**
917 +* Right click [DB], select [properties]
918 +* Uncheck [optimized block access]
751 751  
752 -* Both word registers and bit registers support even continuous read/write functions;
753 -* The range of registers is based on the specific PLC type;
754 -
755 755  **Cable Wiring**
756 756  
757 757  (% style="text-align:center" %)
758 758  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
759 759  
760 -= **IEC60870-5 104 Client** =
925 +== **S7-XXX Ethernet** ==
761 761  
927 +Supported Series: Siemens S7-400, S7-1200 and S7-1500
928 +
762 762  **HMI Setting**
763 763  
764 -(% class="table-bordered" %)
765 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
766 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
767 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
768 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
931 +(% class="table-bordered" style="width:823px" %)
932 +|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note**
933 +|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %)
934 +|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %)
935 +|Port No.|(% style="width:437px" %)102|(% style="width:201px" %)
936 +|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %)
937 +|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %)
769 769  
939 +Slot from TIA Portal is equal to Device No. of PIStudio
940 +
941 +Rack from TIA Portal is equal to HMI No. of PIStudio
942 +
943 +(% style="text-align:center" %)
944 +[[image:S7-XXXCommunication Settings.png]]
945 +
946 +(% style="text-align:center" %)
947 +[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]]
948 +
770 770  **Address List**
771 771  
772 772  (% class="table-bordered" %)
773 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
774 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
775 -|(% style="width:461px" %)SCNA|0~~16777215.7
776 -|(% style="width:461px" %)DPTB|0~~16777215.7
777 -|(% style="width:461px" %)DCNA|0~~16777215.7
778 -|(% style="width:461px" %)METF|0~~16777215.7
779 -|(% style="width:461px" %)SENC|0~~16777215.7
780 -|(% style="width:461px" %)SENA|0~~16777215.7
781 -|(% style="width:461px" %)MENA|0~~16777215.7
782 -|(% style="width:461px" %)METD|0~~16777215.7
783 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
784 -|(% style="width:461px" %)SCNA|0~~16777215
785 -|(% style="width:461px" %)DPTB|0~~16777215
786 -|(% style="width:461px" %)DCNA|0~~16777215
787 -|(% style="width:461px" %)SENA|0~~16777215
788 -|(% style="width:461px" %)MENA|0~~16777215
789 -|(% style="width:461px" %)METD|0~~16777215
790 -|(% style="width:461px" %)INRO|0~~16777215
791 -|(% style="width:461px" %)TIMESYN|0~~16777215
792 -|(% style="width:461px" %)TIMEZ|0~~16777215
793 -|(% style="width:461px" %)NTP|0~~16777215
794 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
795 -|(% style="width:461px" %)SENC|0~~16777215
952 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
953 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
954 +d:0~-~-9999
796 796  
797 -**Address Configuration**
956 +o:0-7
957 +)))|
958 +|Q|Q|Q d.o|(((
959 +d:0~-~-9999
798 798  
799 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
961 +o:0-7
962 +)))|
963 +|M|M|M d.o|(((
964 +d:0~-~-9999
800 800  
801 -(% style="text-align:center" %)
802 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
966 +o:0-7
967 +)))|
968 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
969 +nn:0-9999,
803 803  
804 -(% style="text-align:center" %)
805 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
971 +dddd:0-9999,
806 806  
807 -Extended tag name
973 +o:0-7
974 +)))|(((
975 +nn:DB No.
808 808  
809 -Address range for the extended tag.
977 +dddd:address value
810 810  
979 +o: digit address
980 +)))
981 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
982 +|M|MW|MW d|d:0-99999|(((
983 +MW0=MB(0~~1)
984 +
985 +MW2=MB(2~~3)
986 +
987 +Address value is a multiple of 2
988 +)))
989 +|M|MD|MD d|d:0-99999|(((
990 +MD0=MB(0~~3)
991 +
992 +MD4=MB(4~~7)
993 +
994 +Address value is a multiple of 4
995 +)))
996 +|I|IW|IW d|d:0-99999|
997 +|Q|QW|QW d|d:0-99999|
998 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
999 +nn:0-9999
1000 +
1001 +dddd:0-9999
1002 +)))|(((
1003 +nn:DB No.
1004 +
1005 +dddd:address value
1006 +)))
1007 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
1008 +nn:0-9999
1009 +
1010 +dddd:0-9999
1011 +)))|(((
1012 +nn:DB No.
1013 +
1014 +dddd:address value
1015 +
1016 +Address value is a multiple of 2
1017 +)))
1018 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
1019 +nn:0-9999
1020 +
1021 +dddd:0-9999
1022 +)))|(((
1023 +nn:DB No.
1024 +
1025 +dddd:address value
1026 +
1027 +Address value is a multiple of 4
1028 +)))
1029 +
811 811  **Communication Settings**
812 812  
813 813  Enable HMI Ethernet in [Project Settings];
814 814  
815 815  (% style="text-align:center" %)
816 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1035 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]]
817 817  
818 818  Set PLC IP in [Device IP] settings;
819 819  
820 820  (% style="text-align:center" %)
821 -[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
1040 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
822 822  
1042 +**✎Note:**
1043 +
1044 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
1045 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
1046 +
823 823  **Cable Wiring**
824 824  
825 -(% style="text-align:center" %)
826 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1049 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
827 827  
828 -= **LG XGK FEnet Ethernet** =
1051 +== (% id="cke_bm_25456S" style="display:none" %)** **(%%)**LOGO Ethernet** ==
829 829  
830 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
1053 +Supported Series: Siemens Logo 0BA0 series
831 831  
832 832  **HMI Settings**
833 833  
834 834  (% class="table-bordered" %)
835 835  |**Items**|**Settings**|**Note**
836 -|Protocol|LG XGK FEnet(Ethernet)|
1059 +|Protocol|Siemens LOGO|
837 837  |Connection|Ethernet|
838 -|Port No.|2004|
1061 +|Port No.|102|
1062 +|PLC station No.|2|
839 839  
840 840  **Address List**
841 841  
842 842  (% class="table-bordered" %)
843 -|**Type**|**Register**|**Range**|**Format**|**Note**
844 -|(% rowspan="14" %)Word|P|0~~2047|P d|
845 -|M|0~~2047|M d|
846 -|K|0~~2047|K d|
847 -|F|0~~2047|F d|
848 -|T|0~~2047|T d|
849 -|C|0~~2047|C d|
850 -|Z|0~~127|Z d|
851 -|S|0~~127|S d|
852 -|L|0~~11263|L d|
853 -|N|0~~21503|N d|
854 -|D|0~~32767|D d|
855 -|R|0~~32767|R d|
856 -|ZR|0~~65535|ZR d|
857 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
1067 +|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
1068 +|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
1069 +|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
1070 +|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
1071 +|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
1072 +|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
1073 +|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
1074 +|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
1075 +|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
1076 +|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
1077 +|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
1078 +|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
1079 +|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
1080 +|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
1081 +|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
1082 +|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
858 858  
859 -**✎Note:**
1084 +**PLC Settings in LOGO Software:**
860 860  
861 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
862 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
863 -* All bit registers are in the form of bits in word, and the range is the same as the word register;
1086 +Click [Tools]~-~-[Ethernet Connections],shown as below.
864 864  
865 -**Communication settings in HMI**
1088 +(% style="text-align:center" %)
1089 +[[image:12.PLC Protocol_html_8b9d2322edf89519.png||data-xwiki-image-style-alignment="center" height="641" width="423" class="img-thumbnail"]]
866 866  
867 -Enable HMI Ethernet in [Project Settings];
1091 +Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
868 868  
869 869  (% style="text-align:center" %)
870 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1094 +[[image:12.PLC Protocol_html_6c4dd041b26cd8a1.png||data-xwiki-image-style-alignment="center" height="481" width="363" class="img-thumbnail"]]
871 871  
1096 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
1097 +
1098 +(% style="text-align:center" %)
1099 +[[image:12.PLC Protocol_html_7af2611d3790a77d.png||data-xwiki-image-style-alignment="center" height="359" width="426" class="img-thumbnail"]]
1100 +
1101 +**Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
1102 +
1103 +(% style="text-align:center" %)
1104 +[[image:12.PLC Protocol_html_3243e4cd600595cc.png||data-xwiki-image-style-alignment="center" height="368" width="554" class="img-thumbnail"]]
1105 +
1106 +
1107 +(% style="text-align:center" %)
1108 +[[image:12.PLC Protocol_html_cb1d92e2cc91a8db.png||data-xwiki-image-style-alignment="center" height="320" width="553" class="img-thumbnail"]]
1109 +
1110 +
1111 +**HMI Communication Settings**
1112 +
872 872  Set PLC IP in [Device IP] settings;
873 873  
874 874  (% style="text-align:center" %)
875 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
1116 +[[image:SiemensLOGODeviceIP.png]]
876 876  
1118 +Enable HMI Ethernet in [Project Settings];
1119 +
1120 +(% style="text-align:center" %)
1121 +[[image:12.PLC Protocol_html_95917a3d92068467.png||data-xwiki-image-style-alignment="center" height="311" width="553" class="img-thumbnail"]]
1122 +
1123 +TSAP setting
1124 +
1125 +* Regarding the setting of PLC TSAP, HMI provides system special address for setting, it is recommended to run in HMI script initialization, write PLC TSAP to corresponding system special register.
1126 +* HSW10118 = local TSAP of HMI, this is remote TSAP of PLC.
1127 +* HSW10119 = Remote TSAP of HMI, this is local TSAP of PLC.
1128 +
1129 +**✎Note:**
1130 +
1131 +* The data of TSAP is hexadecimal format. For example: the remote TSAP configured in the PLC is set to 20.00, then HSW10118 should be set to 0x2000, that is, HSW10118 = 8192.
1132 +
1133 +(% style="text-align:center" %)
1134 +[[image:12.PLC Protocol_html_5c6374b21f46e01e.png||data-xwiki-image-style-alignment="center" height="139" width="498" class="img-thumbnail"]]
1135 +
1136 +
1137 +* AI word address and Ibit address are read-only and cannot be written on HMI.
1138 +* VW address should be even number.such as VW0, VW2, VW4...
1139 +* VD address it takes two VW addresses.such as VD0,VD4,VD8...
1140 +* Written value of RTC cannot exceed 255.
1141 +
877 877  **Cable Wiring**
878 878  
879 -= **Mitsubishi** =
1144 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
880 880  
1146 += Create communication with **Mitsubishi** =
1147 +
881 881  == **FX1S, 1N, 2N Series** ==
882 882  
883 883  Supported Series: Mitsubishi FX1S, FX1N, FX2N series
... ... @@ -2649,8 +2649,6 @@
2649 2649  
2650 2650  **✎Note:** COM3 only available in PI8000/PI9000 series.
2651 2651  
2652 -= =
2653 -
2654 2654  = **Printer** =
2655 2655  
2656 2656  == **TSPL label printer** ==
... ... @@ -2851,3 +2851,284 @@
2851 2851  
2852 2852  (% style="text-align:center" %)
2853 2853  [[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]]
3119 +
3120 += **Barcode Scanner** =
3121 +
3122 +Supported: DELI 14880 barcode scanner
3123 +
3124 +**HMI Setting**
3125 +
3126 +|**Items**|**Settings**|**Note**
3127 +|Protocol|Barcode Scanner|
3128 +|Connection|USB|
3129 +
3130 +**Operating Procedures**
3131 +
3132 +Select [Barcode Scanner];
3133 +
3134 +(% style="text-align:center" %)
3135 +[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
3136 +
3137 +Set address for receiving;
3138 +
3139 +Set correct length;
3140 +
3141 +(% style="text-align:center" %)
3142 +[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
3143 +
3144 +**✎Note:**
3145 +
3146 +* The protocol uploads the information acquired by the USB scanner to the HMI;
3147 +* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
3148 +* Recommended model: DELI 14880 barcode scanner;
3149 +
3150 += **Hitachi EHV Series (Ethernet)** =
3151 +
3152 +Supported series: Hitachi EHV series
3153 +
3154 +**HMI Settings**
3155 +
3156 +(% class="table-bordered" %)
3157 +|**Items**|**Settings**|**Note**
3158 +|Protocol|Hitachi EHV series|
3159 +|Connection|Ethernet|
3160 +|Port No.|3004~~3007|
3161 +
3162 +**Address List**
3163 +
3164 +(% class="table-bordered" %)
3165 +|**Type**|**Register**|**Range**|**Format**|**Note**
3166 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
3167 +|M|0 - 7FFF.f (Hex)|M HHHH.h|
3168 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
3169 +H1H2H3H4 Module main number
3170 +
3171 +H1: Remote number
3172 +
3173 +H2: Unit number
3174 +
3175 +H3: Slot number
3176 +
3177 +H4: Word number of Module
3178 +
3179 +H Sub number of Module
3180 +
3181 +For example:X21.3
3182 +
3183 +Slot number 2
3184 +
3185 +Word number of module is 1
3186 +
3187 +Bit number of module is 3
3188 +
3189 +Remote number and unit number are 0
3190 +)))
3191 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
3192 +|R|0 – FF.f (Hex)|R HH.h|
3193 +|L|0 - 73FF.f (Hex)|L HHHH.h|
3194 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
3195 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
3196 +H1H2H3H4 Module main number
3197 +
3198 +H1: Remote number
3199 +
3200 +H2: Unit number
3201 +
3202 +H3: Slot number
3203 +
3204 +H4: Word number of module
3205 +
3206 +For example:WX21
3207 +
3208 +Word number of module is 1
3209 +
3210 +Slot number is 2
3211 +
3212 +Remote number and unit number are 0
3213 +)))
3214 +|WY|0 – FFFF (Hex)|WY H1H2H3H4
3215 +|WR|0 – FFFF (Hex)|WR HHHH|
3216 +|WL|0 - 73FF (Hex)|WL HHHH|
3217 +|TC|0 - 2559|TC DDDD|
3218 +
3219 +**Communication settings in HMI**
3220 +
3221 +Enable HMI Ethernet in [Project Settings];
3222 +
3223 +(% style="text-align:center" %)
3224 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
3225 +
3226 +Set PLC IP in [Device IP] settings;
3227 +
3228 +(% style="text-align:center" %)
3229 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
3230 +
3231 +**PLC Configuration**
3232 +
3233 +Connect with PLC, select[Online mode];
3234 +
3235 +(% style="text-align:center" %)
3236 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
3237 +
3238 +Set IP address, it is the same LAN parameters with HMI;
3239 +
3240 +(% style="text-align:center" %)
3241 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
3242 +
3243 +3) Save PLC communication parameter, and restart PLC
3244 +
3245 +**PLC Monitor Mode**
3246 +
3247 +Connect with PLC and choose to “online” mode
3248 +
3249 +(% style="text-align:center" %)
3250 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
3251 +
3252 +Open I/O monitor sheet1
3253 +
3254 +(% style="text-align:center" %)
3255 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
3256 +
3257 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
3258 +
3259 +(% style="text-align:center" %)
3260 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
3261 +
3262 +Enter the register address, click OK to view the value of the register.
3263 +
3264 +(% style="text-align:center" %)
3265 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
3266 +
3267 +(% style="text-align:center" %)
3268 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
3269 +
3270 +**✎Note:**
3271 +
3272 +* Both word registers and bit registers support even continuous read/write functions;
3273 +* The range of registers is based on the specific PLC type;
3274 +
3275 +**Cable Wiring**
3276 +
3277 +(% style="text-align:center" %)
3278 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
3279 +
3280 += **IEC60870-5 104 Client** =
3281 +
3282 +**HMI Setting**
3283 +
3284 +(% class="table-bordered" %)
3285 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
3286 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
3287 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
3288 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
3289 +
3290 +**Address List**
3291 +
3292 +(% class="table-bordered" %)
3293 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
3294 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
3295 +|(% style="width:461px" %)SCNA|0~~16777215.7
3296 +|(% style="width:461px" %)DPTB|0~~16777215.7
3297 +|(% style="width:461px" %)DCNA|0~~16777215.7
3298 +|(% style="width:461px" %)METF|0~~16777215.7
3299 +|(% style="width:461px" %)SENC|0~~16777215.7
3300 +|(% style="width:461px" %)SENA|0~~16777215.7
3301 +|(% style="width:461px" %)MENA|0~~16777215.7
3302 +|(% style="width:461px" %)METD|0~~16777215.7
3303 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
3304 +|(% style="width:461px" %)SCNA|0~~16777215
3305 +|(% style="width:461px" %)DPTB|0~~16777215
3306 +|(% style="width:461px" %)DCNA|0~~16777215
3307 +|(% style="width:461px" %)SENA|0~~16777215
3308 +|(% style="width:461px" %)MENA|0~~16777215
3309 +|(% style="width:461px" %)METD|0~~16777215
3310 +|(% style="width:461px" %)INRO|0~~16777215
3311 +|(% style="width:461px" %)TIMESYN|0~~16777215
3312 +|(% style="width:461px" %)TIMEZ|0~~16777215
3313 +|(% style="width:461px" %)NTP|0~~16777215
3314 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
3315 +|(% style="width:461px" %)SENC|0~~16777215
3316 +
3317 +**Address Configuration**
3318 +
3319 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
3320 +
3321 +(% style="text-align:center" %)
3322 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
3323 +
3324 +(% style="text-align:center" %)
3325 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
3326 +
3327 +Extended tag name
3328 +
3329 +Address range for the extended tag.
3330 +
3331 +**Communication Settings**
3332 +
3333 +Enable HMI Ethernet in [Project Settings];
3334 +
3335 +(% style="text-align:center" %)
3336 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
3337 +
3338 +Set PLC IP in [Device IP] settings;
3339 +
3340 +(% style="text-align:center" %)
3341 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
3342 +
3343 +**Cable Wiring**
3344 +
3345 +(% style="text-align:center" %)
3346 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
3347 +
3348 += **LG XGK FEnet Ethernet** =
3349 +
3350 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
3351 +
3352 +**HMI Settings**
3353 +
3354 +(% class="table-bordered" %)
3355 +|**Items**|**Settings**|**Note**
3356 +|Protocol|LG XGK FEnet(Ethernet)|
3357 +|Connection|Ethernet|
3358 +|Port No.|2004|
3359 +
3360 +**Address List**
3361 +
3362 +(% class="table-bordered" %)
3363 +|**Type**|**Register**|**Range**|**Format**|**Note**
3364 +|(% rowspan="14" %)Word|P|0~~2047|P d|
3365 +|M|0~~2047|M d|
3366 +|K|0~~2047|K d|
3367 +|F|0~~2047|F d|
3368 +|T|0~~2047|T d|
3369 +|C|0~~2047|C d|
3370 +|Z|0~~127|Z d|
3371 +|S|0~~127|S d|
3372 +|L|0~~11263|L d|
3373 +|N|0~~21503|N d|
3374 +|D|0~~32767|D d|
3375 +|R|0~~32767|R d|
3376 +|ZR|0~~65535|ZR d|
3377 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
3378 +
3379 +**✎Note:**
3380 +
3381 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
3382 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
3383 +* All bit registers are in the form of bits in word, and the range is the same as the word register;
3384 +
3385 +**Communication settings in HMI**
3386 +
3387 +Enable HMI Ethernet in [Project Settings];
3388 +
3389 +(% style="text-align:center" %)
3390 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
3391 +
3392 +Set PLC IP in [Device IP] settings;
3393 +
3394 +(% style="text-align:center" %)
3395 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
3396 +
3397 +**Cable Wiring**
3398 +
3399 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]