Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -141,8 +141,7 @@ 141 141 142 142 [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 143 143 144 -(% class="wikigeneratedid" id="HHMIsettings" %) 145 -**HMI settings** 144 +== HMI settings == 146 146 147 147 **Download PIStudio Software** 148 148 ... ... @@ -231,8 +231,7 @@ 231 231 * HMI setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/>>https://docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/]] 232 232 * PLC setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/>>https://docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/]] 233 233 234 -(% class="wikigeneratedid" id="HPLCsettings" %) 235 -**PLC settings** 233 +== PLC settings == 236 236 237 237 **Download PLC Software** 238 238 ... ... @@ -469,50 +469,10 @@ 469 469 470 470 The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 471 471 472 -= Createcommunicationwith **Rockwell PLC**=470 += = 473 473 472 += **Allen-Bradley** = 474 474 475 -== **MicroLogix Protocol** == 476 - 477 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 478 - 479 -**HMI Settings** 480 - 481 -(% class="table-bordered" %) 482 -|**Item**|**Settings**|**Note** 483 -|Protocol|Allen-Bradlley MicroLogix| 484 -|Connection|RS232| 485 -|Baud rate|19200| 486 -|Data bit|8| 487 -|Parity|None| 488 -|Stop bit|1| 489 -|PLC station No.|1| 490 - 491 -**Address List** 492 - 493 -(% class="table-bordered" %) 494 -|**Type**|**Device registers**|**Format**|**Range**|**Note** 495 -|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 496 -|O|O d.d|0.0~~255.15| 497 -|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 498 -|S|S d.d|0.0~~255.15| 499 -|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 500 -|(% rowspan="9" %)Word|S|S d|0~~255| 501 -|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 502 -|TP|TP nnhh|0~~ffff 503 -|CS|CS nnhh|0~~ffff 504 -|CP|CP nnhh|0~~ffff 505 -|N|N nnhh|0~~ffff 506 -|C|C nnhh|0~~ffff 507 -|T|T nnhh|0~~ffff 508 -|R|R nnhh|0~~ffff 509 - 510 -**Cable Wiring** 511 - 512 - 513 -(% style="text-align:center" %) 514 -[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]] 515 - 516 516 == **FreeTag Ethernet/IP (CompactLogix)** == 517 517 518 518 Allen-Brandly CompactLogix ... ... @@ -570,6 +570,46 @@ 570 570 (% style="text-align:center" %) 571 571 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]] 572 572 531 +== **MicroLogix** == 532 + 533 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 534 + 535 +**HMI Settings** 536 + 537 +(% class="table-bordered" %) 538 +|**Item**|**Settings**|**Note** 539 +|Protocol|Allen-Bradlley MicroLogix| 540 +|Connection|RS232| 541 +|Baud rate|19200| 542 +|Data bit|8| 543 +|Parity|None| 544 +|Stop bit|1| 545 +|PLC station No.|1| 546 + 547 +**Address List** 548 + 549 +(% class="table-bordered" %) 550 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 551 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 552 +|O|O d.d|0.0~~255.15| 553 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 554 +|S|S d.d|0.0~~255.15| 555 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 556 +|(% rowspan="9" %)Word|S|S d|0~~255| 557 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 558 +|TP|TP nnhh|0~~ffff 559 +|CS|CS nnhh|0~~ffff 560 +|CP|CP nnhh|0~~ffff 561 +|N|N nnhh|0~~ffff 562 +|C|C nnhh|0~~ffff 563 +|T|T nnhh|0~~ffff 564 +|R|R nnhh|0~~ffff 565 + 566 +**Cable Wiring** 567 + 568 +(% style="text-align:center" %) 569 +[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]] 570 + 573 573 == **AB PLC address edit** == 574 574 575 575 The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200. ... ... @@ -596,6 +596,37 @@ 596 596 |(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF 597 597 |(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF 598 598 597 += **Barcode Scanner** = 598 + 599 +Supported: DELI 14880 barcode scanner 600 + 601 +**HMI Setting** 602 + 603 +(% class="table-bordered" %) 604 +|**Items**|**Settings**|**Note** 605 +|Protocol|Barcode Scanner| 606 +|Connection|USB| 607 + 608 +**Operating Procedures** 609 + 610 +Select [Barcode Scanner]; 611 + 612 +(% style="text-align:center" %) 613 +[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]] 614 + 615 +Set address for receiving; 616 + 617 +Set correct length; 618 + 619 +(% style="text-align:center" %) 620 +[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]] 621 + 622 +**✎Note:** 623 + 624 +* The protocol uploads the information acquired by the USB scanner to the HMI; 625 +* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 626 +* Recommended model: DELI 14880 barcode scanner; 627 + 599 599 = **Hitachi EHV Series (Ethernet)** = 600 600 601 601 Supported series: Hitachi EHV series ... ... @@ -2618,7 +2618,7 @@ 2618 2618 2619 2619 **✎Note:** COM3 only available in PI8000/PI9000 series. 2620 2620 2621 -= = 2650 += = 2622 2622 2623 2623 = **Printer** = 2624 2624