Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -399,7 +399,6 @@ 399 399 400 400 (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 401 401 402 - 403 403 **Software configuration of PLC** 404 404 405 405 **1)PLC programming software** ... ... @@ -471,7 +471,6 @@ 471 471 472 472 = Create communication with **Rockwell PLC** = 473 473 474 - 475 475 == **MicroLogix Protocol** == 476 476 477 477 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 ... ... @@ -587,264 +587,15 @@ 587 587 |(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15 588 588 |(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15 589 589 |(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15 590 -| (% style="width:393px" %)**PLC word address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range**591 -| (% style="width:393px" %)S|(% style="width:350px" %)ddd|(% style="width:333px" %)S0 ~~ 255592 -| (% style="width:393px" %)TS|(% style="width:350px" %)ffff|(% style="width:333px" %)TS0 ~~ FFFF593 -| (% style="width:393px" %)TP|(% style="width:350px" %)ffff|(% style="width:333px" %)TP0 ~~ FFFF594 -| (% style="width:393px" %)CS|(% style="width:350px" %)ffff|(% style="width:333px" %)CS0 ~~ FFFF595 -| (% style="width:393px" %)CP|(% style="width:350px" %)ffff|(% style="width:333px" %)CP0 ~~ FFFF596 -| (% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF597 -| (% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF588 +|**PLC word address type**|**Address format**|**Address range** 589 +|S|ddd|S0 ~~ 255 590 +|TS|ffff|TS0 ~~ FFFF 591 +|TP|ffff|TP0 ~~ FFFF 592 +|CS|ffff|CS0 ~~ FFFF 593 +|CP|ffff|CP0 ~~ FFFF 594 +|N|ffff|N0 ~~ FFFF 595 +|F|ffff|F0 ~~ FFFF 598 598 599 -= **Hitachi EHV Series (Ethernet)** = 600 - 601 -Supported series: Hitachi EHV series 602 - 603 -**HMI Settings** 604 - 605 -(% class="table-bordered" %) 606 -|**Items**|**Settings**|**Note** 607 -|Protocol|Hitachi EHV series| 608 -|Connection|Ethernet| 609 -|Port No.|3004~~3007| 610 - 611 -**Address List** 612 - 613 -(% class="table-bordered" %) 614 -|**Type**|**Register**|**Range**|**Format**|**Note** 615 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 616 -|M|0 - 7FFF.f (Hex)|M HHHH.h| 617 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 618 -H1H2H3H4 Module main number 619 - 620 -H1: Remote number 621 - 622 -H2: Unit number 623 - 624 -H3: Slot number 625 - 626 -H4: Word number of Module 627 - 628 -H Sub number of Module 629 - 630 -For example:X21.3 631 - 632 -Slot number 2 633 - 634 -Word number of module is 1 635 - 636 -Bit number of module is 3 637 - 638 -Remote number and unit number are 0 639 -))) 640 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 641 -|R|0 – FF.f (Hex)|R HH.h| 642 -|L|0 - 73FF.f (Hex)|L HHHH.h| 643 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 644 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 645 -H1H2H3H4 Module main number 646 - 647 -H1: Remote number 648 - 649 -H2: Unit number 650 - 651 -H3: Slot number 652 - 653 -H4: Word number of module 654 - 655 -For example:WX21 656 - 657 -Word number of module is 1 658 - 659 -Slot number is 2 660 - 661 -Remote number and unit number are 0 662 -))) 663 -|WY|0 – FFFF (Hex)|WY H1H2H3H4 664 -|WR|0 – FFFF (Hex)|WR HHHH| 665 -|WL|0 - 73FF (Hex)|WL HHHH| 666 -|TC|0 - 2559|TC DDDD| 667 - 668 -**Communication settings in HMI** 669 - 670 -Enable HMI Ethernet in [Project Settings]; 671 - 672 -(% style="text-align:center" %) 673 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 674 - 675 -Set PLC IP in [Device IP] settings; 676 - 677 -(% style="text-align:center" %) 678 -[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 679 - 680 -**PLC Configuration** 681 - 682 -Connect with PLC, select[Online mode]; 683 - 684 -(% style="text-align:center" %) 685 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 686 - 687 -Set IP address, it is the same LAN parameters with HMI; 688 - 689 -(% style="text-align:center" %) 690 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 691 - 692 -3) Save PLC communication parameter, and restart PLC 693 - 694 -**PLC Monitor Mode** 695 - 696 -Connect with PLC and choose to “online” mode 697 - 698 -(% style="text-align:center" %) 699 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 700 - 701 -Open I/O monitor sheet1 702 - 703 -(% style="text-align:center" %) 704 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 705 - 706 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 707 - 708 -(% style="text-align:center" %) 709 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 710 - 711 -Enter the register address, click OK to view the value of the register. 712 - 713 -(% style="text-align:center" %) 714 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 715 - 716 -(% style="text-align:center" %) 717 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 718 - 719 -**✎Note:** 720 - 721 -* Both word registers and bit registers support even continuous read/write functions; 722 -* The range of registers is based on the specific PLC type; 723 - 724 -**Cable Wiring** 725 - 726 -(% style="text-align:center" %) 727 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 728 - 729 -= **IEC60870-5 104 Client** = 730 - 731 -**HMI Setting** 732 - 733 -(% class="table-bordered" %) 734 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 735 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 736 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 737 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 738 - 739 -**Address List** 740 - 741 -(% class="table-bordered" %) 742 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 743 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 744 -|(% style="width:461px" %)SCNA|0~~16777215.7 745 -|(% style="width:461px" %)DPTB|0~~16777215.7 746 -|(% style="width:461px" %)DCNA|0~~16777215.7 747 -|(% style="width:461px" %)METF|0~~16777215.7 748 -|(% style="width:461px" %)SENC|0~~16777215.7 749 -|(% style="width:461px" %)SENA|0~~16777215.7 750 -|(% style="width:461px" %)MENA|0~~16777215.7 751 -|(% style="width:461px" %)METD|0~~16777215.7 752 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 753 -|(% style="width:461px" %)SCNA|0~~16777215 754 -|(% style="width:461px" %)DPTB|0~~16777215 755 -|(% style="width:461px" %)DCNA|0~~16777215 756 -|(% style="width:461px" %)SENA|0~~16777215 757 -|(% style="width:461px" %)MENA|0~~16777215 758 -|(% style="width:461px" %)METD|0~~16777215 759 -|(% style="width:461px" %)INRO|0~~16777215 760 -|(% style="width:461px" %)TIMESYN|0~~16777215 761 -|(% style="width:461px" %)TIMEZ|0~~16777215 762 -|(% style="width:461px" %)NTP|0~~16777215 763 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 764 -|(% style="width:461px" %)SENC|0~~16777215 765 - 766 -**Address Configuration** 767 - 768 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 769 - 770 -(% style="text-align:center" %) 771 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 772 - 773 -(% style="text-align:center" %) 774 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 775 - 776 -Extended tag name 777 - 778 -Address range for the extended tag. 779 - 780 -**Communication Settings** 781 - 782 -Enable HMI Ethernet in [Project Settings]; 783 - 784 -(% style="text-align:center" %) 785 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 786 - 787 -Set PLC IP in [Device IP] settings; 788 - 789 -(% style="text-align:center" %) 790 -[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]] 791 - 792 -**Cable Wiring** 793 - 794 -(% style="text-align:center" %) 795 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 796 - 797 -= **LG XGK FEnet Ethernet** = 798 - 799 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 800 - 801 -**HMI Settings** 802 - 803 -(% class="table-bordered" %) 804 -|**Items**|**Settings**|**Note** 805 -|Protocol|LG XGK FEnet(Ethernet)| 806 -|Connection|Ethernet| 807 -|Port No.|2004| 808 - 809 -**Address List** 810 - 811 -(% class="table-bordered" %) 812 -|**Type**|**Register**|**Range**|**Format**|**Note** 813 -|(% rowspan="14" %)Word|P|0~~2047|P d| 814 -|M|0~~2047|M d| 815 -|K|0~~2047|K d| 816 -|F|0~~2047|F d| 817 -|T|0~~2047|T d| 818 -|C|0~~2047|C d| 819 -|Z|0~~127|Z d| 820 -|S|0~~127|S d| 821 -|L|0~~11263|L d| 822 -|N|0~~21503|N d| 823 -|D|0~~32767|D d| 824 -|R|0~~32767|R d| 825 -|ZR|0~~65535|ZR d| 826 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 827 - 828 -**✎Note:** 829 - 830 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 831 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 832 -* All bit registers are in the form of bits in word, and the range is the same as the word register; 833 - 834 -**Communication settings in HMI** 835 - 836 -Enable HMI Ethernet in [Project Settings]; 837 - 838 -(% style="text-align:center" %) 839 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 840 - 841 -Set PLC IP in [Device IP] settings; 842 - 843 -(% style="text-align:center" %) 844 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 845 - 846 -**Cable Wiring** 847 - 848 848 = **Mitsubishi** = 849 849 850 850 == **FX1S, 1N, 2N Series** == ... ... @@ -2618,8 +2618,6 @@ 2618 2618 2619 2619 **✎Note:** COM3 only available in PI8000/PI9000 series. 2620 2620 2621 -= = 2622 - 2623 2623 = **Printer** = 2624 2624 2625 2625 == **TSPL label printer** == ... ... @@ -2820,3 +2820,284 @@ 2820 2820 2821 2821 (% style="text-align:center" %) 2822 2822 [[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]] 2570 + 2571 += **Barcode Scanner** = 2572 + 2573 +Supported: DELI 14880 barcode scanner 2574 + 2575 +**HMI Setting** 2576 + 2577 +|**Items**|**Settings**|**Note** 2578 +|Protocol|Barcode Scanner| 2579 +|Connection|USB| 2580 + 2581 +**Operating Procedures** 2582 + 2583 +Select [Barcode Scanner]; 2584 + 2585 +(% style="text-align:center" %) 2586 +[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]] 2587 + 2588 +Set address for receiving; 2589 + 2590 +Set correct length; 2591 + 2592 +(% style="text-align:center" %) 2593 +[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]] 2594 + 2595 +**✎Note:** 2596 + 2597 +* The protocol uploads the information acquired by the USB scanner to the HMI; 2598 +* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 2599 +* Recommended model: DELI 14880 barcode scanner; 2600 + 2601 += **Hitachi EHV Series (Ethernet)** = 2602 + 2603 +Supported series: Hitachi EHV series 2604 + 2605 +**HMI Settings** 2606 + 2607 +(% class="table-bordered" %) 2608 +|**Items**|**Settings**|**Note** 2609 +|Protocol|Hitachi EHV series| 2610 +|Connection|Ethernet| 2611 +|Port No.|3004~~3007| 2612 + 2613 +**Address List** 2614 + 2615 +(% class="table-bordered" %) 2616 +|**Type**|**Register**|**Range**|**Format**|**Note** 2617 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 2618 +|M|0 - 7FFF.f (Hex)|M HHHH.h| 2619 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 2620 +H1H2H3H4 Module main number 2621 + 2622 +H1: Remote number 2623 + 2624 +H2: Unit number 2625 + 2626 +H3: Slot number 2627 + 2628 +H4: Word number of Module 2629 + 2630 +H Sub number of Module 2631 + 2632 +For example:X21.3 2633 + 2634 +Slot number 2 2635 + 2636 +Word number of module is 1 2637 + 2638 +Bit number of module is 3 2639 + 2640 +Remote number and unit number are 0 2641 +))) 2642 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 2643 +|R|0 – FF.f (Hex)|R HH.h| 2644 +|L|0 - 73FF.f (Hex)|L HHHH.h| 2645 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 2646 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 2647 +H1H2H3H4 Module main number 2648 + 2649 +H1: Remote number 2650 + 2651 +H2: Unit number 2652 + 2653 +H3: Slot number 2654 + 2655 +H4: Word number of module 2656 + 2657 +For example:WX21 2658 + 2659 +Word number of module is 1 2660 + 2661 +Slot number is 2 2662 + 2663 +Remote number and unit number are 0 2664 +))) 2665 +|WY|0 – FFFF (Hex)|WY H1H2H3H4 2666 +|WR|0 – FFFF (Hex)|WR HHHH| 2667 +|WL|0 - 73FF (Hex)|WL HHHH| 2668 +|TC|0 - 2559|TC DDDD| 2669 + 2670 +**Communication settings in HMI** 2671 + 2672 +Enable HMI Ethernet in [Project Settings]; 2673 + 2674 +(% style="text-align:center" %) 2675 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2676 + 2677 +Set PLC IP in [Device IP] settings; 2678 + 2679 +(% style="text-align:center" %) 2680 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 2681 + 2682 +**PLC Configuration** 2683 + 2684 +Connect with PLC, select[Online mode]; 2685 + 2686 +(% style="text-align:center" %) 2687 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 2688 + 2689 +Set IP address, it is the same LAN parameters with HMI; 2690 + 2691 +(% style="text-align:center" %) 2692 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 2693 + 2694 +3) Save PLC communication parameter, and restart PLC 2695 + 2696 +**PLC Monitor Mode** 2697 + 2698 +Connect with PLC and choose to “online” mode 2699 + 2700 +(% style="text-align:center" %) 2701 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 2702 + 2703 +Open I/O monitor sheet1 2704 + 2705 +(% style="text-align:center" %) 2706 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 2707 + 2708 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 2709 + 2710 +(% style="text-align:center" %) 2711 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 2712 + 2713 +Enter the register address, click OK to view the value of the register. 2714 + 2715 +(% style="text-align:center" %) 2716 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 2717 + 2718 +(% style="text-align:center" %) 2719 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 2720 + 2721 +**✎Note:** 2722 + 2723 +* Both word registers and bit registers support even continuous read/write functions; 2724 +* The range of registers is based on the specific PLC type; 2725 + 2726 +**Cable Wiring** 2727 + 2728 +(% style="text-align:center" %) 2729 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 2730 + 2731 += **IEC60870-5 104 Client** = 2732 + 2733 +**HMI Setting** 2734 + 2735 +(% class="table-bordered" %) 2736 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 2737 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 2738 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 2739 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 2740 + 2741 +**Address List** 2742 + 2743 +(% class="table-bordered" %) 2744 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 2745 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 2746 +|(% style="width:461px" %)SCNA|0~~16777215.7 2747 +|(% style="width:461px" %)DPTB|0~~16777215.7 2748 +|(% style="width:461px" %)DCNA|0~~16777215.7 2749 +|(% style="width:461px" %)METF|0~~16777215.7 2750 +|(% style="width:461px" %)SENC|0~~16777215.7 2751 +|(% style="width:461px" %)SENA|0~~16777215.7 2752 +|(% style="width:461px" %)MENA|0~~16777215.7 2753 +|(% style="width:461px" %)METD|0~~16777215.7 2754 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 2755 +|(% style="width:461px" %)SCNA|0~~16777215 2756 +|(% style="width:461px" %)DPTB|0~~16777215 2757 +|(% style="width:461px" %)DCNA|0~~16777215 2758 +|(% style="width:461px" %)SENA|0~~16777215 2759 +|(% style="width:461px" %)MENA|0~~16777215 2760 +|(% style="width:461px" %)METD|0~~16777215 2761 +|(% style="width:461px" %)INRO|0~~16777215 2762 +|(% style="width:461px" %)TIMESYN|0~~16777215 2763 +|(% style="width:461px" %)TIMEZ|0~~16777215 2764 +|(% style="width:461px" %)NTP|0~~16777215 2765 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 2766 +|(% style="width:461px" %)SENC|0~~16777215 2767 + 2768 +**Address Configuration** 2769 + 2770 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 2771 + 2772 +(% style="text-align:center" %) 2773 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 2774 + 2775 +(% style="text-align:center" %) 2776 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 2777 + 2778 +Extended tag name 2779 + 2780 +Address range for the extended tag. 2781 + 2782 +**Communication Settings** 2783 + 2784 +Enable HMI Ethernet in [Project Settings]; 2785 + 2786 +(% style="text-align:center" %) 2787 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2788 + 2789 +Set PLC IP in [Device IP] settings; 2790 + 2791 +(% style="text-align:center" %) 2792 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]] 2793 + 2794 +**Cable Wiring** 2795 + 2796 +(% style="text-align:center" %) 2797 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 2798 + 2799 += **LG XGK FEnet Ethernet** = 2800 + 2801 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 2802 + 2803 +**HMI Settings** 2804 + 2805 +(% class="table-bordered" %) 2806 +|**Items**|**Settings**|**Note** 2807 +|Protocol|LG XGK FEnet(Ethernet)| 2808 +|Connection|Ethernet| 2809 +|Port No.|2004| 2810 + 2811 +**Address List** 2812 + 2813 +(% class="table-bordered" %) 2814 +|**Type**|**Register**|**Range**|**Format**|**Note** 2815 +|(% rowspan="14" %)Word|P|0~~2047|P d| 2816 +|M|0~~2047|M d| 2817 +|K|0~~2047|K d| 2818 +|F|0~~2047|F d| 2819 +|T|0~~2047|T d| 2820 +|C|0~~2047|C d| 2821 +|Z|0~~127|Z d| 2822 +|S|0~~127|S d| 2823 +|L|0~~11263|L d| 2824 +|N|0~~21503|N d| 2825 +|D|0~~32767|D d| 2826 +|R|0~~32767|R d| 2827 +|ZR|0~~65535|ZR d| 2828 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 2829 + 2830 +**✎Note:** 2831 + 2832 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 2833 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 2834 +* All bit registers are in the form of bits in word, and the range is the same as the word register; 2835 + 2836 +**Communication settings in HMI** 2837 + 2838 +Enable HMI Ethernet in [Project Settings]; 2839 + 2840 +(% style="text-align:center" %) 2841 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2842 + 2843 +Set PLC IP in [Device IP] settings; 2844 + 2845 +(% style="text-align:center" %) 2846 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 2847 + 2848 +**Cable Wiring** 2849 + 2850 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]