... ... @@ -399,7 +399,6 @@
399 399  
400 400  (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
401 401  
402 -
403 403  **Software configuration of PLC**
404 404  
405 405  **1)PLC programming software**
... ... @@ -471,7 +471,6 @@
471 471  
472 472  = Create communication with **Rockwell PLC** =
473 473  
474 -
475 475  == **MicroLogix Protocol** ==
476 476  
477 477  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
... ... @@ -587,86 +587,160 @@
587 587  |(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15
588 588  |(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15
589 589  |(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15
590 -|(% style="width:393px" %)**PLC word address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range**
591 -|(% style="width:393px" %)S|(% style="width:350px" %)ddd|(% style="width:333px" %)S0 ~~ 255
592 -|(% style="width:393px" %)TS|(% style="width:350px" %)ffff|(% style="width:333px" %)TS0 ~~ FFFF
593 -|(% style="width:393px" %)TP|(% style="width:350px" %)ffff|(% style="width:333px" %)TP0 ~~ FFFF
594 -|(% style="width:393px" %)CS|(% style="width:350px" %)ffff|(% style="width:333px" %)CS0 ~~ FFFF
595 -|(% style="width:393px" %)CP|(% style="width:350px" %)ffff|(% style="width:333px" %)CP0 ~~ FFFF
596 -|(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF
597 -|(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF
588 +|**PLC word address type**|**Address format**|**Address range**
589 +|S|ddd|S0 ~~ 255
590 +|TS|ffff|TS0 ~~ FFFF
591 +|TP|ffff|TP0 ~~ FFFF
592 +|CS|ffff|CS0 ~~ FFFF
593 +|CP|ffff|CP0 ~~ FFFF
594 +|N|ffff|N0 ~~ FFFF
595 +|F|ffff|F0 ~~ FFFF
598 598  
599 -= **Hitachi EHV Series (Ethernet)** =
597 += (% id="cke_bm_43878S" style="display:none" %)** **(%%)**Siemens** =
600 600  
601 -Supported series: Hitachi EHV series
599 +== **S7-200 Smart Ethernet** ==
602 602  
603 -**HMI Settings**
601 +Supported Series: Siemens S7-200 SMART Series Ethernet Module.
604 604  
603 +Website: [[http:~~/~~/www.siemens.com/entry/cc/en/>>url:http://www.siemens.com/entry/cc/en/]]
604 +
605 +**HMI Setting**
606 +
605 605  (% class="table-bordered" %)
606 606  |**Items**|**Settings**|**Note**
607 -|Protocol|Hitachi EHV series|
609 +|Protocol|Simens S7-200 Smart Ethernet|
608 608  |Connection|Ethernet|
609 -|Port No.|3004~~3007|
611 +|Port No.|102|
612 +|PLC station No.|2|
610 610  
611 611  **Address List**
612 612  
613 613  (% class="table-bordered" %)
614 -|**Type**|**Register**|**Range**|**Format**|**Note**
615 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
616 -|M|0 - 7FFF.f (Hex)|M HHHH.h|
617 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
618 -H1H2H3H4 Module main number
617 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
618 +|(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
619 +|Q|Q|Q ddddd.o|0.0~~99999.7|
620 +|V|VWbit|VWbit ddddd.o|0.0~~99999.7|
621 +|V|V|V ddddd.o|0.0~~99999.7|
622 +|M|M|M ddddd.o|0.0~~99999.7|
623 +|SM|SM|ddddd.o|0.0~~99999.7|
624 +|S|S|ddddd.o|0.0~~99999.7|Read only
625 +|T|T|ddddd|0~~99999|Timer state, read only
626 +|C|C|ddddd|0~~99999|Counter state, read only
627 +|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999|
628 +|Q|QW|QW ddddd|0~~99999|
629 +|AI|AIW|AIW ddddd|0~~99999|
630 +|AQ|VB|VB ddddd|0~~99999|
631 +|V|VW|VW ddddd|0~~99998|(((
632 +VW0=VB (0~~1)
619 619  
620 -H1: Remote number
634 +VW2=VB (2~~3)
621 621  
622 -H2: Unit number
636 +Address value is a multiple of 2
637 +)))
638 +|V|VD|VD ddddd|0~~99998|(((
639 +VD0=VB (0~~3)
623 623  
624 -H3: Slot number
641 +VD2=VB (4~~7)
625 625  
626 -H4: Word number of Module
643 +Address value is a multiple of 4
644 +)))
645 +|M|MB|MB ddddd|0~~99999|
646 +|M|MW|MW ddddd|0~~99999|(((
647 +MW0=MB(0~~1)
627 627  
628 -H Sub number of Module
649 +MW2=MB(2~~3)
629 629  
630 -For example:X21.3
651 +Address value is a multiple of 2
652 +)))
653 +|M|MD|MD ddddd|0~~99999|(((
654 +MD0=MB(0~~3)
631 631  
632 -Slot number 2
656 +MD4=MB(4~~7)
633 633  
634 -Word number of module is 1
658 +Address value is a multiple of 4
659 +)))
660 +|T|TW|TW ddddd|0~~99999|Value of timer
661 +|C|CW|CW ddddd|0~~99999|Value of counter
662 +|W|SW|SW ddddd|0~~99999|
635 635  
636 -Bit number of module is 3
664 +**Communication Settings**
637 637  
638 -Remote number and unit number are 0
639 -)))
640 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
641 -|R|0 – FF.f (Hex)|R HH.h|
642 -|L|0 - 73FF.f (Hex)|L HHHH.h|
643 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
644 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
645 -H1H2H3H4 Module main number
666 +Enable HMI Ethernet in [Project Settings];
646 646  
647 -H1: Remote number
668 +(% style="text-align:center" %)
669 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
648 648  
649 -H2: Unit number
671 +Set PLC IP in [Device IP] settings;
650 650  
651 -H3: Slot number
673 +(% style="text-align:center" %)
674 +[[image:12.PLC Protocol_html_70b0c4c2ee21b10d.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
652 652  
653 -H4: Word number of module
676 +* PLC IP Address: PLC IP
677 +* PLC pot No.: 102(fixed)
678 +* Network:TCP_Client_2N(fixed)
654 654  
655 -For example:WX21
680 +(% style="text-align:center" %)
681 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
656 656  
657 -Word number of module is 1
683 +* Wait timeout: depend on actual network situation (more than 1500 ms)
658 658  
659 -Slot number is 2
685 +**Cable Wiring**
660 660  
661 -Remote number and unit number are 0
687 +(% style="text-align:center" %)
688 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
689 +
690 +== **S7-300 Ethernet** ==
691 +
692 +Supported Series: Siemens S7-300 series PLC
693 +
694 +**HMI Setting**
695 +
696 +(% class="table-bordered" %)
697 +|**Items**|**Settings**|**Note**
698 +|Protocol|Simens S7-300 Ethernet|
699 +|Connection|Ethernet|
700 +|Port No.|102|
701 +|PLC station No.|2|Need to be same as the PLC setting
702 +
703 +**Address List**
704 +
705 +(% class="table-bordered" %)
706 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
707 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
708 +|Q|Q|Q ddddd.o|0.0~~99999.7|
709 +|M|M|M ddddd.o|0.0~~99999.7|
710 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
711 +nn: block number;
712 +
713 +dddd: address;
662 662  )))
663 -|WY|0 – FFFF (Hex)|WY H1H2H3H4
664 -|WR|0 – FFFF (Hex)|WR HHHH|
665 -|WL|0 - 73FF (Hex)|WL HHHH|
666 -|TC|0 - 2559|TC DDDD|
715 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
716 +|Q|QW|QW ddddd|0~~99999|
717 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
718 +|MW|MW ddddd|0~~99999|(((
719 +MW0=MB(0~~1)
667 667  
668 -**Communication settings in HMI**
721 +MW2=MB(2~~3)
669 669  
723 +Address value is a multiple of 2
724 +)))
725 +|MD|MD ddddd|0~~99999|(((
726 +MD0=MB(0~~3)
727 +
728 +MD4=MB(4~~7)
729 +
730 +Address value is a multiple of 4
731 +)))
732 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
733 +nn: block number;
734 +
735 +dddd: address
736 +)))
737 +|DBxDBW|DBxDBW nndddd|0~~99999999
738 +|DBxDBD|DBxDBD nndddd|0~~99999999
739 +
740 +**Communication Settings**
741 +
670 670  Enable HMI Ethernet in [Project Settings];
671 671  
672 672  (% style="text-align:center" %)
... ... @@ -675,178 +675,405 @@
675 675  Set PLC IP in [Device IP] settings;
676 676  
677 677  (% style="text-align:center" %)
678 -[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
750 +[[image:12.PLC Protocol_html_910b1a0aa9e2201c.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]]
679 679  
680 -**PLC Configuration**
752 +* PLC IP Address: PLC IP
753 +* PLC pot No.: 102(fixed)
754 +* Network:TCP_Client_2N(fixed)
681 681  
682 -Connect with PLC, select[Online mode];
683 -
684 684  (% style="text-align:center" %)
685 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
757 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
686 686  
687 -Set IP address, it is the same LAN parameters with HMI;
759 +* Wait timeout: depend on actual network situation (more than 1500 ms)
688 688  
761 +**Cable Wiring**
762 +
689 689  (% style="text-align:center" %)
690 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
764 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
691 691  
692 -3) Save PLC communication parameter, and restart PLC
766 +== **S7-1200 Ethernet** ==
693 693  
694 -**PLC Monitor Mode**
768 +Supported Series: Siemens S7-1200
695 695  
696 -Connect with PLC and choose to “online” mode
770 +**HMI Setting**
697 697  
772 +(% class="table-bordered" %)
773 +|**Items**|**Settings**|**Note**
774 +|Protocol|Siemens S7-1200|
775 +|Connection|Ethernet|
776 +|Port No.|102|
777 +|PLC station No.|2|
778 +
779 +**Address List**
780 +
781 +(% class="table-bordered" %)
782 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
783 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
784 +d:0~-~-9999
785 +
786 +o:0-7
787 +)))|
788 +|Q|Q|Q d.o|(((
789 +d:0~-~-9999
790 +
791 +o:0-7
792 +)))|
793 +|M|M|M d.o|(((
794 +d:0~-~-9999
795 +
796 +o:0-7
797 +)))|
798 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
799 +nn:0-9999,
800 +
801 +dddd:0-9999,
802 +
803 +o:0-7
804 +)))|(((
805 +nn:DB No.
806 +
807 +dddd:address value
808 +
809 +o: digit address
810 +)))
811 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
812 +|M|MW|MW d|d:0-99999|(((
813 +MW0=MB(0~~1)
814 +
815 +MW2=MB(2~~3)
816 +
817 +Address value is a multiple of 2
818 +)))
819 +|M|MD|MD d|d:0-99999|(((
820 +MD0=MB(0~~3)
821 +
822 +MD4=MB(4~~7)
823 +
824 +Address value is a multiple of 4
825 +)))
826 +|I|IW|IW d|d:0-99999|
827 +|Q|QW|QW d|d:0-99999|
828 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
829 +nn:0-9999
830 +
831 +dddd:0-9999
832 +)))|(((
833 +nn:DB No.
834 +
835 +dddd:address value
836 +)))
837 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
838 +nn:0-9999
839 +
840 +dddd:0-9999
841 +)))|(((
842 +nn:DB No.
843 +
844 +dddd:address value
845 +
846 +Address value is a multiple of 2
847 +)))
848 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
849 +nn:0-9999
850 +
851 +dddd:0-9999
852 +)))|(((
853 +nn:DB No.
854 +
855 +dddd:address value
856 +
857 +Address value is a multiple of 4
858 +)))
859 +
860 +**Communication Settings**
861 +
862 +Enable HMI Ethernet in [Project Settings];
863 +
698 698  (% style="text-align:center" %)
699 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
865 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
700 700  
701 -Open I/O monitor sheet1
867 +Set PLC IP in [Device IP] settings;
702 702  
703 703  (% style="text-align:center" %)
704 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
870 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
705 705  
706 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
872 +**✎Note:**
707 707  
874 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
875 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
876 +
877 +**PLC Settings**
878 +
879 +Add BD
880 +
881 +* Please uncheck [Symbolic access only] option;
882 +
708 708  (% style="text-align:center" %)
709 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
884 +[[image:12.PLC Protocol_html_643144c591994418.png||data-xwiki-image-style-alignment="center" height="546" width="550" class="img-thumbnail"]]
710 710  
711 -Enter the register address, click OK to view the value of the register.
886 +Address settings, using BD2 as example.
712 712  
888 +* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1.
889 +* 2 represent DB block number
890 +* xxxx represent address
891 +
892 +**Such as:**
893 +
894 +* DBxDBB20000 = DB2.DBB0
895 +* DBxDBW20004 = DB2.DBW4
896 +
713 713  (% style="text-align:center" %)
714 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
898 +[[image:12.PLC Protocol_html_87ceaea84d552e62.png||data-xwiki-image-style-alignment="center" height="245" width="537" class="img-thumbnail"]]
715 715  
900 +**How to connect with S7-1200 Firmware V4.0**
901 +
902 +PLC configuration
903 +
904 +* Double click [device configuration] in Siemens via software
905 +* Double click [protection] to enter protection configuration screen
906 +
716 716  (% style="text-align:center" %)
717 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
908 +[[image:12.PLC Protocol_html_9779940d38da8e07.png||data-xwiki-image-style-alignment="center" height="426" width="341" class="img-thumbnail"]]
718 718  
719 -**✎Note:**
910 +* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)]
720 720  
721 -* Both word registers and bit registers support even continuous read/write functions;
722 -* The range of registers is based on the specific PLC type;
912 +(% style="text-align:center" %)
913 +[[image:12.PLC Protocol_html_d2c667b02f9720b1.png||data-xwiki-image-style-alignment="center" height="296" width="554" class="img-thumbnail"]]
723 723  
915 +DB settings
916 +
917 +* Right click [DB], select [properties]
918 +* Uncheck [optimized block access]
919 +
724 724  **Cable Wiring**
725 725  
726 726  (% style="text-align:center" %)
727 727  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
728 728  
729 -= **IEC60870-5 104 Client** =
925 +== **LOGO Ethernet** ==
730 730  
731 -**HMI Setting**
927 +Supported Series: Siemens Logo 0BA0 series
732 732  
929 +**HMI Settings**
930 +
733 733  (% class="table-bordered" %)
734 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
735 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
736 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
737 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
932 +|**Items**|**Settings**|**Note**
933 +|Protocol|Siemens LOGO|
934 +|Connection|Ethernet|
935 +|Port No.|102|
936 +|PLC station No.|2|
738 738  
739 739  **Address List**
740 740  
741 741  (% class="table-bordered" %)
742 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
743 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
744 -|(% style="width:461px" %)SCNA|0~~16777215.7
745 -|(% style="width:461px" %)DPTB|0~~16777215.7
746 -|(% style="width:461px" %)DCNA|0~~16777215.7
747 -|(% style="width:461px" %)METF|0~~16777215.7
748 -|(% style="width:461px" %)SENC|0~~16777215.7
749 -|(% style="width:461px" %)SENA|0~~16777215.7
750 -|(% style="width:461px" %)MENA|0~~16777215.7
751 -|(% style="width:461px" %)METD|0~~16777215.7
752 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
753 -|(% style="width:461px" %)SCNA|0~~16777215
754 -|(% style="width:461px" %)DPTB|0~~16777215
755 -|(% style="width:461px" %)DCNA|0~~16777215
756 -|(% style="width:461px" %)SENA|0~~16777215
757 -|(% style="width:461px" %)MENA|0~~16777215
758 -|(% style="width:461px" %)METD|0~~16777215
759 -|(% style="width:461px" %)INRO|0~~16777215
760 -|(% style="width:461px" %)TIMESYN|0~~16777215
761 -|(% style="width:461px" %)TIMEZ|0~~16777215
762 -|(% style="width:461px" %)NTP|0~~16777215
763 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
764 -|(% style="width:461px" %)SENC|0~~16777215
941 +|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
942 +|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
943 +|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
944 +|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
945 +|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
946 +|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
947 +|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
948 +|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
949 +|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
950 +|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
951 +|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
952 +|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
953 +|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
954 +|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
955 +|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
956 +|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
765 765  
766 -**Address Configuration**
958 +**PLC Settings in LOGO Software:**
767 767  
768 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
960 +Click [Tools]~-~-[Ethernet Connections],shown as below.
769 769  
770 770  (% style="text-align:center" %)
771 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
963 +[[image:12.PLC Protocol_html_8b9d2322edf89519.png||data-xwiki-image-style-alignment="center" height="641" width="423" class="img-thumbnail"]]
772 772  
965 +Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
966 +
773 773  (% style="text-align:center" %)
774 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
968 +[[image:12.PLC Protocol_html_6c4dd041b26cd8a1.png||data-xwiki-image-style-alignment="center" height="481" width="363" class="img-thumbnail"]]
775 775  
776 -Extended tag name
970 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
777 777  
778 -Address range for the extended tag.
972 +(% style="text-align:center" %)
973 +[[image:12.PLC Protocol_html_7af2611d3790a77d.png||data-xwiki-image-style-alignment="center" height="359" width="426" class="img-thumbnail"]]
779 779  
780 -**Communication Settings**
975 +**Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
781 781  
782 -Enable HMI Ethernet in [Project Settings];
977 +(% style="text-align:center" %)
978 +[[image:12.PLC Protocol_html_3243e4cd600595cc.png||data-xwiki-image-style-alignment="center" height="368" width="554" class="img-thumbnail"]]
783 783  
980 +
784 784  (% style="text-align:center" %)
785 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
982 +[[image:12.PLC Protocol_html_cb1d92e2cc91a8db.png||data-xwiki-image-style-alignment="center" height="320" width="553" class="img-thumbnail"]]
786 786  
984 +
985 +**HMI Communication Settings**
986 +
787 787  Set PLC IP in [Device IP] settings;
788 788  
789 789  (% style="text-align:center" %)
790 -[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
990 +[[image:SiemensLOGODeviceIP.png]]
791 791  
992 +Enable HMI Ethernet in [Project Settings];
993 +
994 +(% style="text-align:center" %)
995 +[[image:12.PLC Protocol_html_95917a3d92068467.png||data-xwiki-image-style-alignment="center" height="311" width="553" class="img-thumbnail"]]
996 +
997 +TSAP setting
998 +
999 +* Regarding the setting of PLC TSAP, HMI provides system special address for setting, it is recommended to run in HMI script initialization, write PLC TSAP to corresponding system special register.
1000 +* HSW10118 = local TSAP of HMI, this is remote TSAP of PLC.
1001 +* HSW10119 = Remote TSAP of HMI, this is local TSAP of PLC.
1002 +
1003 +**✎Note:**
1004 +
1005 +* The data of TSAP is hexadecimal format. For example: the remote TSAP configured in the PLC is set to 20.00, then HSW10118 should be set to 0x2000, that is, HSW10118 = 8192.
1006 +
1007 +(% style="text-align:center" %)
1008 +[[image:12.PLC Protocol_html_5c6374b21f46e01e.png||data-xwiki-image-style-alignment="center" height="139" width="498" class="img-thumbnail"]]
1009 +
1010 +
1011 +* AI word address and Ibit address are read-only and cannot be written on HMI.
1012 +* VW address should be even number.such as VW0, VW2, VW4...
1013 +* VD address it takes two VW addresses.such as VD0,VD4,VD8...
1014 +* Written value of RTC cannot exceed 255.
1015 +
792 792  **Cable Wiring**
793 793  
794 794  (% style="text-align:center" %)
795 795  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
796 796  
797 -= **LG XGK FEnet Ethernet** =
1021 +== **S7-XXX Ethernet** ==
798 798  
799 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
1023 +Supported Series: Siemens S7-400, S7-1200 and S7-1500
800 800  
801 -**HMI Settings**
1025 +**HMI Setting**
802 802  
803 -(% class="table-bordered" %)
804 -|**Items**|**Settings**|**Note**
805 -|Protocol|LG XGK FEnet(Ethernet)|
806 -|Connection|Ethernet|
807 -|Port No.|2004|
1027 +(% class="table-bordered" style="width:823px" %)
1028 +|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note**
1029 +|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %)
1030 +|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %)
1031 +|Port No.|(% style="width:437px" %)102|(% style="width:201px" %)
1032 +|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %)
1033 +|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %)
808 808  
1035 +Slot from TIA Portal is equal to Device No. of PIStudio
1036 +
1037 +Rack from TIA Portal is equal to HMI No. of PIStudio
1038 +
1039 +(% style="text-align:center" %)
1040 +[[image:S7-XXXCommunication Settings.png]]
1041 +
1042 +(% style="text-align:center" %)
1043 +[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]]
1044 +
809 809  **Address List**
810 810  
811 811  (% class="table-bordered" %)
812 -|**Type**|**Register**|**Range**|**Format**|**Note**
813 -|(% rowspan="14" %)Word|P|0~~2047|P d|
814 -|M|0~~2047|M d|
815 -|K|0~~2047|K d|
816 -|F|0~~2047|F d|
817 -|T|0~~2047|T d|
818 -|C|0~~2047|C d|
819 -|Z|0~~127|Z d|
820 -|S|0~~127|S d|
821 -|L|0~~11263|L d|
822 -|N|0~~21503|N d|
823 -|D|0~~32767|D d|
824 -|R|0~~32767|R d|
825 -|ZR|0~~65535|ZR d|
826 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
1048 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
1049 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
1050 +d:0~-~-9999
827 827  
828 -**✎Note:**
1052 +o:0-7
1053 +)))|
1054 +|Q|Q|Q d.o|(((
1055 +d:0~-~-9999
829 829  
830 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
831 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
832 -* All bit registers are in the form of bits in word, and the range is the same as the word register;
1057 +o:0-7
1058 +)))|
1059 +|M|M|M d.o|(((
1060 +d:0~-~-9999
833 833  
834 -**Communication settings in HMI**
1062 +o:0-7
1063 +)))|
1064 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
1065 +nn:0-9999,
835 835  
1067 +dddd:0-9999,
1068 +
1069 +o:0-7
1070 +)))|(((
1071 +nn:DB No.
1072 +
1073 +dddd:address value
1074 +
1075 +o: digit address
1076 +)))
1077 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
1078 +|M|MW|MW d|d:0-99999|(((
1079 +MW0=MB(0~~1)
1080 +
1081 +MW2=MB(2~~3)
1082 +
1083 +Address value is a multiple of 2
1084 +)))
1085 +|M|MD|MD d|d:0-99999|(((
1086 +MD0=MB(0~~3)
1087 +
1088 +MD4=MB(4~~7)
1089 +
1090 +Address value is a multiple of 4
1091 +)))
1092 +|I|IW|IW d|d:0-99999|
1093 +|Q|QW|QW d|d:0-99999|
1094 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
1095 +nn:0-9999
1096 +
1097 +dddd:0-9999
1098 +)))|(((
1099 +nn:DB No.
1100 +
1101 +dddd:address value
1102 +)))
1103 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
1104 +nn:0-9999
1105 +
1106 +dddd:0-9999
1107 +)))|(((
1108 +nn:DB No.
1109 +
1110 +dddd:address value
1111 +
1112 +Address value is a multiple of 2
1113 +)))
1114 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
1115 +nn:0-9999
1116 +
1117 +dddd:0-9999
1118 +)))|(((
1119 +nn:DB No.
1120 +
1121 +dddd:address value
1122 +
1123 +Address value is a multiple of 4
1124 +)))
1125 +
1126 +**Communication Settings**
1127 +
836 836  Enable HMI Ethernet in [Project Settings];
837 837  
838 838  (% style="text-align:center" %)
839 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1131 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]]
840 840  
841 841  Set PLC IP in [Device IP] settings;
842 842  
843 843  (% style="text-align:center" %)
844 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
1136 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
845 845  
1138 +**✎Note:**
1139 +
1140 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
1141 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
1142 +
846 846  **Cable Wiring**
847 847  
848 -= **Mitsubishi** =
1145 +{{id name="OLE_LINK8"/}}
849 849  
1147 += Create communication with **Mitsubishi** =
1148 +
850 850  == **FX1S, 1N, 2N Series** ==
851 851  
852 852  Supported Series: Mitsubishi FX1S, FX1N, FX2N series
... ... @@ -2848,3 +2848,254 @@
2848 2848  * The protocol uploads the information acquired by the USB scanner to the HMI;
2849 2849  * The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
2850 2850  * Recommended model: DELI 14880 barcode scanner;
3150 +
3151 += **Hitachi EHV Series (Ethernet)** =
3152 +
3153 +Supported series: Hitachi EHV series
3154 +
3155 +**HMI Settings**
3156 +
3157 +(% class="table-bordered" %)
3158 +|**Items**|**Settings**|**Note**
3159 +|Protocol|Hitachi EHV series|
3160 +|Connection|Ethernet|
3161 +|Port No.|3004~~3007|
3162 +
3163 +**Address List**
3164 +
3165 +(% class="table-bordered" %)
3166 +|**Type**|**Register**|**Range**|**Format**|**Note**
3167 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
3168 +|M|0 - 7FFF.f (Hex)|M HHHH.h|
3169 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
3170 +H1H2H3H4 Module main number
3171 +
3172 +H1: Remote number
3173 +
3174 +H2: Unit number
3175 +
3176 +H3: Slot number
3177 +
3178 +H4: Word number of Module
3179 +
3180 +H Sub number of Module
3181 +
3182 +For example:X21.3
3183 +
3184 +Slot number 2
3185 +
3186 +Word number of module is 1
3187 +
3188 +Bit number of module is 3
3189 +
3190 +Remote number and unit number are 0
3191 +)))
3192 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
3193 +|R|0 – FF.f (Hex)|R HH.h|
3194 +|L|0 - 73FF.f (Hex)|L HHHH.h|
3195 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
3196 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
3197 +H1H2H3H4 Module main number
3198 +
3199 +H1: Remote number
3200 +
3201 +H2: Unit number
3202 +
3203 +H3: Slot number
3204 +
3205 +H4: Word number of module
3206 +
3207 +For example:WX21
3208 +
3209 +Word number of module is 1
3210 +
3211 +Slot number is 2
3212 +
3213 +Remote number and unit number are 0
3214 +)))
3215 +|WY|0 – FFFF (Hex)|WY H1H2H3H4
3216 +|WR|0 – FFFF (Hex)|WR HHHH|
3217 +|WL|0 - 73FF (Hex)|WL HHHH|
3218 +|TC|0 - 2559|TC DDDD|
3219 +
3220 +**Communication settings in HMI**
3221 +
3222 +Enable HMI Ethernet in [Project Settings];
3223 +
3224 +(% style="text-align:center" %)
3225 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
3226 +
3227 +Set PLC IP in [Device IP] settings;
3228 +
3229 +(% style="text-align:center" %)
3230 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
3231 +
3232 +**PLC Configuration**
3233 +
3234 +Connect with PLC, select[Online mode];
3235 +
3236 +(% style="text-align:center" %)
3237 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
3238 +
3239 +Set IP address, it is the same LAN parameters with HMI;
3240 +
3241 +(% style="text-align:center" %)
3242 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
3243 +
3244 +3) Save PLC communication parameter, and restart PLC
3245 +
3246 +**PLC Monitor Mode**
3247 +
3248 +Connect with PLC and choose to “online” mode
3249 +
3250 +(% style="text-align:center" %)
3251 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
3252 +
3253 +Open I/O monitor sheet1
3254 +
3255 +(% style="text-align:center" %)
3256 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
3257 +
3258 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
3259 +
3260 +(% style="text-align:center" %)
3261 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
3262 +
3263 +Enter the register address, click OK to view the value of the register.
3264 +
3265 +(% style="text-align:center" %)
3266 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
3267 +
3268 +(% style="text-align:center" %)
3269 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
3270 +
3271 +**✎Note:**
3272 +
3273 +* Both word registers and bit registers support even continuous read/write functions;
3274 +* The range of registers is based on the specific PLC type;
3275 +
3276 +**Cable Wiring**
3277 +
3278 +(% style="text-align:center" %)
3279 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
3280 +
3281 += **IEC60870-5 104 Client** =
3282 +
3283 +**HMI Setting**
3284 +
3285 +(% class="table-bordered" %)
3286 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
3287 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
3288 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
3289 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
3290 +
3291 +**Address List**
3292 +
3293 +(% class="table-bordered" %)
3294 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
3295 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
3296 +|(% style="width:461px" %)SCNA|0~~16777215.7
3297 +|(% style="width:461px" %)DPTB|0~~16777215.7
3298 +|(% style="width:461px" %)DCNA|0~~16777215.7
3299 +|(% style="width:461px" %)METF|0~~16777215.7
3300 +|(% style="width:461px" %)SENC|0~~16777215.7
3301 +|(% style="width:461px" %)SENA|0~~16777215.7
3302 +|(% style="width:461px" %)MENA|0~~16777215.7
3303 +|(% style="width:461px" %)METD|0~~16777215.7
3304 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
3305 +|(% style="width:461px" %)SCNA|0~~16777215
3306 +|(% style="width:461px" %)DPTB|0~~16777215
3307 +|(% style="width:461px" %)DCNA|0~~16777215
3308 +|(% style="width:461px" %)SENA|0~~16777215
3309 +|(% style="width:461px" %)MENA|0~~16777215
3310 +|(% style="width:461px" %)METD|0~~16777215
3311 +|(% style="width:461px" %)INRO|0~~16777215
3312 +|(% style="width:461px" %)TIMESYN|0~~16777215
3313 +|(% style="width:461px" %)TIMEZ|0~~16777215
3314 +|(% style="width:461px" %)NTP|0~~16777215
3315 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
3316 +|(% style="width:461px" %)SENC|0~~16777215
3317 +
3318 +**Address Configuration**
3319 +
3320 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
3321 +
3322 +(% style="text-align:center" %)
3323 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
3324 +
3325 +(% style="text-align:center" %)
3326 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
3327 +
3328 +Extended tag name
3329 +
3330 +Address range for the extended tag.
3331 +
3332 +**Communication Settings**
3333 +
3334 +Enable HMI Ethernet in [Project Settings];
3335 +
3336 +(% style="text-align:center" %)
3337 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
3338 +
3339 +Set PLC IP in [Device IP] settings;
3340 +
3341 +(% style="text-align:center" %)
3342 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
3343 +
3344 +**Cable Wiring**
3345 +
3346 +(% style="text-align:center" %)
3347 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
3348 +
3349 += **LG XGK FEnet Ethernet** =
3350 +
3351 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
3352 +
3353 +**HMI Settings**
3354 +
3355 +(% class="table-bordered" %)
3356 +|**Items**|**Settings**|**Note**
3357 +|Protocol|LG XGK FEnet(Ethernet)|
3358 +|Connection|Ethernet|
3359 +|Port No.|2004|
3360 +
3361 +**Address List**
3362 +
3363 +(% class="table-bordered" %)
3364 +|**Type**|**Register**|**Range**|**Format**|**Note**
3365 +|(% rowspan="14" %)Word|P|0~~2047|P d|
3366 +|M|0~~2047|M d|
3367 +|K|0~~2047|K d|
3368 +|F|0~~2047|F d|
3369 +|T|0~~2047|T d|
3370 +|C|0~~2047|C d|
3371 +|Z|0~~127|Z d|
3372 +|S|0~~127|S d|
3373 +|L|0~~11263|L d|
3374 +|N|0~~21503|N d|
3375 +|D|0~~32767|D d|
3376 +|R|0~~32767|R d|
3377 +|ZR|0~~65535|ZR d|
3378 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
3379 +
3380 +**✎Note:**
3381 +
3382 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
3383 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
3384 +* All bit registers are in the form of bits in word, and the range is the same as the word register;
3385 +
3386 +**Communication settings in HMI**
3387 +
3388 +Enable HMI Ethernet in [Project Settings];
3389 +
3390 +(% style="text-align:center" %)
3391 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
3392 +
3393 +Set PLC IP in [Device IP] settings;
3394 +
3395 +(% style="text-align:center" %)
3396 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
3397 +
3398 +**Cable Wiring**
3399 +
3400 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]