Changes for page 12 PLC Protocol OLD

Last modified by Mora Zhou on 2024/12/05 14:53

From version 78.1
edited by Ben
on 2022/08/29 14:19
Change comment: There is no comment for this version
To version 124.1
edited by Ben
on 2022/08/30 14:22
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -511,7 +511,7 @@
511 511  (% style="text-align:center" %)
512 512  [[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]]
513 513  
514 -== **FreeTag Ethernet/IP (CompactLogix)** ==
514 +== **CompactLogix FreeTag Ethernet protocol** ==
515 515  
516 516  Allen-Brandly CompactLogix
517 517  
... ... @@ -568,7 +568,7 @@
568 568  (% style="text-align:center" %)
569 569  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]]
570 570  
571 -== **AB PLC address edit** ==
571 +== **MicroLogix 1200** ** protocol** ==
572 572  
573 573  The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200.
574 574  
... ... @@ -585,21 +585,568 @@
585 585  |(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15
586 586  |(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15
587 587  |(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15
588 -|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
589 -|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
590 -|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
591 -|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
592 -|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
593 -|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
594 -|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
595 -|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
588 +|**PLC word address type**|**Address format**|**Address range**
589 +|S|ddd|S0 ~~ 255
590 +|TS|ffff|TS0 ~~ FFFF
591 +|TP|ffff|TP0 ~~ FFFF
592 +|CS|ffff|CS0 ~~ FFFF
593 +|CP|ffff|CP0 ~~ FFFF
594 +|N|ffff|N0 ~~ FFFF
595 +|F|ffff|F0 ~~ FFFF
596 596  
597 -= =
597 += Create communication with (% id="cke_bm_43878S" style="display:none" %)** **(%%)**Siemens PLC** =
598 598  
599 -= **Mitsubishi** =
599 +== **S7-200 Smart Ethernet Protocol** ==
600 600  
601 -== **FX1S, 1N, 2N Series** ==
601 +Supported Series: Siemens S7-200 SMART Series Ethernet Module.
602 602  
603 +Website: [[http:~~/~~/www.siemens.com/entry/cc/en/>>url:http://www.siemens.com/entry/cc/en/]]
604 +
605 +**HMI Setting**
606 +
607 +(% class="table-bordered" %)
608 +|**Items**|**Settings**|**Note**
609 +|Protocol|Simens S7-200 Smart Ethernet|
610 +|Connection|Ethernet|
611 +|Port No.|102|
612 +|PLC station No.|2|
613 +
614 +**Address List**
615 +
616 +(% class="table-bordered" %)
617 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
618 +|(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
619 +|Q|Q|Q ddddd.o|0.0~~99999.7|
620 +|V|VWbit|VWbit ddddd.o|0.0~~99999.7|
621 +|V|V|V ddddd.o|0.0~~99999.7|
622 +|M|M|M ddddd.o|0.0~~99999.7|
623 +|SM|SM|ddddd.o|0.0~~99999.7|
624 +|S|S|ddddd.o|0.0~~99999.7|Read only
625 +|T|T|ddddd|0~~99999|Timer state, read only
626 +|C|C|ddddd|0~~99999|Counter state, read only
627 +|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999|
628 +|Q|QW|QW ddddd|0~~99999|
629 +|AI|AIW|AIW ddddd|0~~99999|
630 +|AQ|VB|VB ddddd|0~~99999|
631 +|V|VW|VW ddddd|0~~99998|(((
632 +VW0=VB (0~~1)
633 +
634 +VW2=VB (2~~3)
635 +
636 +Address value is a multiple of 2
637 +)))
638 +|V|VD|VD ddddd|0~~99998|(((
639 +VD0=VB (0~~3)
640 +
641 +VD2=VB (4~~7)
642 +
643 +Address value is a multiple of 4
644 +)))
645 +|M|MB|MB ddddd|0~~99999|
646 +|M|MW|MW ddddd|0~~99999|(((
647 +MW0=MB(0~~1)
648 +
649 +MW2=MB(2~~3)
650 +
651 +Address value is a multiple of 2
652 +)))
653 +|M|MD|MD ddddd|0~~99999|(((
654 +MD0=MB(0~~3)
655 +
656 +MD4=MB(4~~7)
657 +
658 +Address value is a multiple of 4
659 +)))
660 +|T|TW|TW ddddd|0~~99999|Value of timer
661 +|C|CW|CW ddddd|0~~99999|Value of counter
662 +|W|SW|SW ddddd|0~~99999|
663 +
664 +**Communication Settings**
665 +
666 +Enable HMI Ethernet in [Project Settings];
667 +
668 +(% style="text-align:center" %)
669 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
670 +
671 +Set PLC IP in [Device IP] settings;
672 +
673 +(% style="text-align:center" %)
674 +[[image:12.PLC Protocol_html_70b0c4c2ee21b10d.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
675 +
676 +* PLC IP Address: PLC IP
677 +* PLC pot No.: 102(fixed)
678 +* Network:TCP_Client_2N(fixed)
679 +
680 +(% style="text-align:center" %)
681 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
682 +
683 +* Wait timeout: depend on actual network situation (more than 1500 ms)
684 +
685 +**Cable Wiring**
686 +
687 +(% style="text-align:center" %)
688 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
689 +
690 +== **S7-300 Ethernet Protocol** ==
691 +
692 +Supported Series: Siemens S7-300 series PLC
693 +
694 +**HMI Setting**
695 +
696 +(% class="table-bordered" %)
697 +|**Items**|**Settings**|**Note**
698 +|Protocol|Simens S7-300 Ethernet|
699 +|Connection|Ethernet|
700 +|Port No.|102|
701 +|PLC station No.|2|Need to be same as the PLC setting
702 +
703 +**Address List**
704 +
705 +(% class="table-bordered" %)
706 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
707 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
708 +|Q|Q|Q ddddd.o|0.0~~99999.7|
709 +|M|M|M ddddd.o|0.0~~99999.7|
710 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
711 +nn: block number;
712 +
713 +dddd: address;
714 +)))
715 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
716 +|Q|QW|QW ddddd|0~~99999|
717 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
718 +|MW|MW ddddd|0~~99999|(((
719 +MW0=MB(0~~1)
720 +
721 +MW2=MB(2~~3)
722 +
723 +Address value is a multiple of 2
724 +)))
725 +|MD|MD ddddd|0~~99999|(((
726 +MD0=MB(0~~3)
727 +
728 +MD4=MB(4~~7)
729 +
730 +Address value is a multiple of 4
731 +)))
732 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
733 +nn: block number;
734 +
735 +dddd: address
736 +)))
737 +|DBxDBW|DBxDBW nndddd|0~~99999999
738 +|DBxDBD|DBxDBD nndddd|0~~99999999
739 +
740 +**Communication Settings**
741 +
742 +Enable HMI Ethernet in [Project Settings];
743 +
744 +(% style="text-align:center" %)
745 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
746 +
747 +Set PLC IP in [Device IP] settings;
748 +
749 +(% style="text-align:center" %)
750 +[[image:12.PLC Protocol_html_910b1a0aa9e2201c.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]]
751 +
752 +* PLC IP Address: PLC IP
753 +* PLC pot No.: 102(fixed)
754 +* Network:TCP_Client_2N(fixed)
755 +
756 +(% style="text-align:center" %)
757 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
758 +
759 +* Wait timeout: depend on actual network situation (more than 1500 ms)
760 +
761 +**Cable Wiring**
762 +
763 +(% style="text-align:center" %)
764 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
765 +
766 +== **S7-1200 Ethernet Protocol** ==
767 +
768 +Supported Series: Siemens S7-1200
769 +
770 +**HMI Setting**
771 +
772 +(% class="table-bordered" %)
773 +|**Items**|**Settings**|**Note**
774 +|Protocol|Siemens S7-1200|
775 +|Connection|Ethernet|
776 +|Port No.|102|
777 +|PLC station No.|2|
778 +
779 +**Address List**
780 +
781 +(% class="table-bordered" %)
782 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
783 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
784 +d:0~-~-9999
785 +
786 +o:0-7
787 +)))|
788 +|Q|Q|Q d.o|(((
789 +d:0~-~-9999
790 +
791 +o:0-7
792 +)))|
793 +|M|M|M d.o|(((
794 +d:0~-~-9999
795 +
796 +o:0-7
797 +)))|
798 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
799 +nn:0-9999,
800 +
801 +dddd:0-9999,
802 +
803 +o:0-7
804 +)))|(((
805 +nn:DB No.
806 +
807 +dddd:address value
808 +
809 +o: digit address
810 +)))
811 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
812 +|M|MW|MW d|d:0-99999|(((
813 +MW0=MB(0~~1)
814 +
815 +MW2=MB(2~~3)
816 +
817 +Address value is a multiple of 2
818 +)))
819 +|M|MD|MD d|d:0-99999|(((
820 +MD0=MB(0~~3)
821 +
822 +MD4=MB(4~~7)
823 +
824 +Address value is a multiple of 4
825 +)))
826 +|I|IW|IW d|d:0-99999|
827 +|Q|QW|QW d|d:0-99999|
828 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
829 +nn:0-9999
830 +
831 +dddd:0-9999
832 +)))|(((
833 +nn:DB No.
834 +
835 +dddd:address value
836 +)))
837 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
838 +nn:0-9999
839 +
840 +dddd:0-9999
841 +)))|(((
842 +nn:DB No.
843 +
844 +dddd:address value
845 +
846 +Address value is a multiple of 2
847 +)))
848 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
849 +nn:0-9999
850 +
851 +dddd:0-9999
852 +)))|(((
853 +nn:DB No.
854 +
855 +dddd:address value
856 +
857 +Address value is a multiple of 4
858 +)))
859 +
860 +**Communication Settings**
861 +
862 +Enable HMI Ethernet in [Project Settings];
863 +
864 +(% style="text-align:center" %)
865 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
866 +
867 +Set PLC IP in [Device IP] settings;
868 +
869 +(% style="text-align:center" %)
870 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
871 +
872 +**✎Note:**
873 +
874 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
875 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
876 +
877 +**PLC Settings**
878 +
879 +Add BD
880 +
881 +* Please uncheck [Symbolic access only] option;
882 +
883 +(% style="text-align:center" %)
884 +[[image:12.PLC Protocol_html_643144c591994418.png||data-xwiki-image-style-alignment="center" height="546" width="550" class="img-thumbnail"]]
885 +
886 +Address settings, using BD2 as example.
887 +
888 +* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1.
889 +* 2 represent DB block number
890 +* xxxx represent address
891 +
892 +**Such as:**
893 +
894 +* DBxDBB20000 = DB2.DBB0
895 +* DBxDBW20004 = DB2.DBW4
896 +
897 +(% style="text-align:center" %)
898 +[[image:12.PLC Protocol_html_87ceaea84d552e62.png||data-xwiki-image-style-alignment="center" height="245" width="537" class="img-thumbnail"]]
899 +
900 +**How to connect with S7-1200 Firmware V4.0**
901 +
902 +PLC configuration
903 +
904 +* Double click [device configuration] in Siemens via software
905 +* Double click [protection] to enter protection configuration screen
906 +
907 +(% style="text-align:center" %)
908 +[[image:12.PLC Protocol_html_9779940d38da8e07.png||data-xwiki-image-style-alignment="center" height="426" width="341" class="img-thumbnail"]]
909 +
910 +* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)]
911 +
912 +(% style="text-align:center" %)
913 +[[image:12.PLC Protocol_html_d2c667b02f9720b1.png||data-xwiki-image-style-alignment="center" height="296" width="554" class="img-thumbnail"]]
914 +
915 +DB settings
916 +
917 +* Right click [DB], select [properties]
918 +* Uncheck [optimized block access]
919 +
920 +**Cable Wiring**
921 +
922 +(% style="text-align:center" %)
923 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
924 +
925 +== **S7-XXX Ethernet Protocol** ==
926 +
927 +Supported Series: Siemens S7-400, S7-1200 and S7-1500
928 +
929 +**HMI Setting**
930 +
931 +(% class="table-bordered" style="width:823px" %)
932 +|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note**
933 +|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %)
934 +|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %)
935 +|Port No.|(% style="width:437px" %)102|(% style="width:201px" %)
936 +|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %)
937 +|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %)
938 +
939 +Slot from TIA Portal is equal to Device No. of PIStudio
940 +
941 +Rack from TIA Portal is equal to HMI No. of PIStudio
942 +
943 +(% style="text-align:center" %)
944 +[[image:S7-XXXCommunication Settings.png]]
945 +
946 +(% style="text-align:center" %)
947 +[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]]
948 +
949 +**Address List**
950 +
951 +(% class="table-bordered" %)
952 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
953 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
954 +d:0~-~-9999
955 +
956 +o:0-7
957 +)))|
958 +|Q|Q|Q d.o|(((
959 +d:0~-~-9999
960 +
961 +o:0-7
962 +)))|
963 +|M|M|M d.o|(((
964 +d:0~-~-9999
965 +
966 +o:0-7
967 +)))|
968 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
969 +nn:0-9999,
970 +
971 +dddd:0-9999,
972 +
973 +o:0-7
974 +)))|(((
975 +nn:DB No.
976 +
977 +dddd:address value
978 +
979 +o: digit address
980 +)))
981 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
982 +|M|MW|MW d|d:0-99999|(((
983 +MW0=MB(0~~1)
984 +
985 +MW2=MB(2~~3)
986 +
987 +Address value is a multiple of 2
988 +)))
989 +|M|MD|MD d|d:0-99999|(((
990 +MD0=MB(0~~3)
991 +
992 +MD4=MB(4~~7)
993 +
994 +Address value is a multiple of 4
995 +)))
996 +|I|IW|IW d|d:0-99999|
997 +|Q|QW|QW d|d:0-99999|
998 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
999 +nn:0-9999
1000 +
1001 +dddd:0-9999
1002 +)))|(((
1003 +nn:DB No.
1004 +
1005 +dddd:address value
1006 +)))
1007 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
1008 +nn:0-9999
1009 +
1010 +dddd:0-9999
1011 +)))|(((
1012 +nn:DB No.
1013 +
1014 +dddd:address value
1015 +
1016 +Address value is a multiple of 2
1017 +)))
1018 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
1019 +nn:0-9999
1020 +
1021 +dddd:0-9999
1022 +)))|(((
1023 +nn:DB No.
1024 +
1025 +dddd:address value
1026 +
1027 +Address value is a multiple of 4
1028 +)))
1029 +
1030 +**Communication Settings**
1031 +
1032 +Enable HMI Ethernet in [Project Settings];
1033 +
1034 +(% style="text-align:center" %)
1035 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]]
1036 +
1037 +Set PLC IP in [Device IP] settings;
1038 +
1039 +(% style="text-align:center" %)
1040 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
1041 +
1042 +**✎Note:**
1043 +
1044 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
1045 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
1046 +
1047 +**Cable Wiring**
1048 +
1049 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1050 +
1051 +== (% id="cke_bm_25456S" style="display:none" %)** **(%%)**LOGO Ethernet Protocol** ==
1052 +
1053 +Supported Series: Siemens Logo 0BA0 series
1054 +
1055 +**HMI Settings**
1056 +
1057 +(% class="table-bordered" %)
1058 +|**Items**|**Settings**|**Note**
1059 +|Protocol|Siemens LOGO|
1060 +|Connection|Ethernet|
1061 +|Port No.|102|
1062 +|PLC station No.|2|
1063 +
1064 +**Address List**
1065 +
1066 +(% class="table-bordered" %)
1067 +|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
1068 +|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
1069 +|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
1070 +|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
1071 +|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
1072 +|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
1073 +|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
1074 +|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
1075 +|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
1076 +|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
1077 +|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
1078 +|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
1079 +|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
1080 +|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
1081 +|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
1082 +|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
1083 +
1084 +**PLC Settings in LOGO Software:**
1085 +
1086 +Click [Tools]~-~-[Ethernet Connections],shown as below.
1087 +
1088 +(% style="text-align:center" %)
1089 +[[image:12.PLC Protocol_html_8b9d2322edf89519.png||data-xwiki-image-style-alignment="center" height="641" width="423" class="img-thumbnail"]]
1090 +
1091 +Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
1092 +
1093 +(% style="text-align:center" %)
1094 +[[image:12.PLC Protocol_html_6c4dd041b26cd8a1.png||data-xwiki-image-style-alignment="center" height="481" width="363" class="img-thumbnail"]]
1095 +
1096 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
1097 +
1098 +(% style="text-align:center" %)
1099 +[[image:12.PLC Protocol_html_7af2611d3790a77d.png||data-xwiki-image-style-alignment="center" height="359" width="426" class="img-thumbnail"]]
1100 +
1101 +**Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
1102 +
1103 +(% style="text-align:center" %)
1104 +[[image:12.PLC Protocol_html_3243e4cd600595cc.png||data-xwiki-image-style-alignment="center" height="368" width="554" class="img-thumbnail"]]
1105 +
1106 +
1107 +(% style="text-align:center" %)
1108 +[[image:12.PLC Protocol_html_cb1d92e2cc91a8db.png||data-xwiki-image-style-alignment="center" height="320" width="553" class="img-thumbnail"]]
1109 +
1110 +
1111 +**HMI Communication Settings**
1112 +
1113 +Set PLC IP in [Device IP] settings;
1114 +
1115 +(% style="text-align:center" %)
1116 +[[image:SiemensLOGODeviceIP.png]]
1117 +
1118 +Enable HMI Ethernet in [Project Settings];
1119 +
1120 +(% style="text-align:center" %)
1121 +[[image:12.PLC Protocol_html_95917a3d92068467.png||data-xwiki-image-style-alignment="center" height="311" width="553" class="img-thumbnail"]]
1122 +
1123 +TSAP setting
1124 +
1125 +* Regarding the setting of PLC TSAP, HMI provides system special address for setting, it is recommended to run in HMI script initialization, write PLC TSAP to corresponding system special register.
1126 +* HSW10118 = local TSAP of HMI, this is remote TSAP of PLC.
1127 +* HSW10119 = Remote TSAP of HMI, this is local TSAP of PLC.
1128 +
1129 +**✎Note:**
1130 +
1131 +* The data of TSAP is hexadecimal format. For example: the remote TSAP configured in the PLC is set to 20.00, then HSW10118 should be set to 0x2000, that is, HSW10118 = 8192.
1132 +
1133 +(% style="text-align:center" %)
1134 +[[image:12.PLC Protocol_html_5c6374b21f46e01e.png||data-xwiki-image-style-alignment="center" height="139" width="498" class="img-thumbnail"]]
1135 +
1136 +
1137 +* AI word address and Ibit address are read-only and cannot be written on HMI.
1138 +* VW address should be even number.such as VW0, VW2, VW4...
1139 +* VD address it takes two VW addresses.such as VD0,VD4,VD8...
1140 +* Written value of RTC cannot exceed 255.
1141 +
1142 +**Cable Wiring**
1143 +
1144 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1145 +
1146 += Create communication with **Mitsubishi PLC** =
1147 +
1148 +== **FX1S, 1N, 2N Series Protocol** ==
1149 +
603 603  Supported Series: Mitsubishi FX1S, FX1N, FX2N series
604 604  
605 605  **HMI Settings**
... ... @@ -651,7 +651,7 @@
651 651  
652 652  **✎Note:** COM3 only available in PI8000/PI9000 series.
653 653  
654 -== **FX5U Ethernet** ==
1201 +== **FX5U Ethernet Protocol** ==
655 655  
656 656  Mitsubishi FX5U series PLC
657 657  
... ... @@ -730,7 +730,7 @@
730 730  (% style="text-align:center" %)
731 731  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
732 732  
733 -== **FX5U Serial Port** ==
1280 +== **FX5U Serial Port Protocol** ==
734 734  
735 735  Mitsubishi FX5U series PLC
736 736  
... ... @@ -822,7 +822,7 @@
822 822  
823 823  **✎Note:** COM3 only available in PI8000/PI9000 series.
824 824  
825 -== **L02 MELSEC (Ethernet)** ==
1372 +== **L02 MELSEC (Ethernet) Protocol** ==
826 826  
827 827  Mitsubishi Q series CPU built-in Ethernet port.
828 828  
... ... @@ -907,7 +907,7 @@
907 907  (% style="text-align:center" %)
908 908  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
909 909  
910 -== **QJ71E71 MELSEC** ==
1457 +== **QJ71E71 MELSEC Protocol** ==
911 911  
912 912  Mitsubishi QJ71E71 Ethernet communication module;
913 913  
... ... @@ -987,219 +987,200 @@
987 987  (% style="text-align:center" %)
988 988  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
989 989  
990 -= **MODBUS** =
1537 += Create communication with **Delta PLC** =
991 991  
992 -== **MODBUS RTU Master** ==
1539 +== **DVP serial protocol** ==
993 993  
994 -Supported Series: MODBUS RTU CONTROLLER
1541 +(% class="wikigeneratedid" %)
1542 +Supported Series: Delta DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX Controller
995 995  
996 -HMI works as MODBUS SLAVE connecting with MASTER
1544 +**1)HMI Settings**
997 997  
998 -(% style="text-align:center" %)
999 -[[image:12.PLC Protocol_html_44425b313b0a6b96.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]
1546 +|**Item**|**Settings**|**Note**
1547 +|Protocol|DELTA DVP Series|
1548 +|Connection|RS485|
1549 +|Baud rate|9600|
1550 +|Data bit|7|
1551 +|Parity|Even|
1552 +|Stop bit|1|
1553 +|PLC station No.|1~~255|Need to be the same as PLC settings
1000 1000  
1555 +**2)Address List**
1001 1001  
1002 -(% style="text-align:center" %)
1003 -[[image:12.PLC Protocol_html_b56b9da32c3caaa.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1557 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1558 +|Bit|X|X|X d|0~~303237|
1559 +|Bit|Y|Y|Y d|0~~303237|
1560 +|Bit|M|M|M d|0~~99999|
1561 +|Bit|T|T|T d|0~~99999|
1562 +|Bit|C|C|T d|0~~99999|
1563 +|Bit|S|S|T d|0~~99999|
1564 +|Word|D|D|D d|0~~99999|
1565 +|Word|T|T|T d|0~~99999|
1566 +|Word|C|C|C d|0~~99999|
1004 1004  
1568 +(% class="wikigeneratedid" %)
1569 +**3)Configure the communication protocol**
1005 1005  
1006 -(% style="text-align:center" %)
1007 -[[image:12.PLC Protocol_html_67cd25458b9c72a6.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1571 +(% class="wikigeneratedid" %)
1572 +[[image:image-20220829152327-6.png]]
1008 1008  
1009 -**HMI Settings**
1574 +(% class="wikigeneratedid" %)
1575 +[[image:image-20220829152016-3.png]]
1010 1010  
1011 -(% class="table-bordered" %)
1012 -|**Items**|**Settings**|**Note**
1013 -|Protocol|MODBUS RTU Master|
1014 -|Connection|RS485/RS232|
1015 -|Baud rate|2400~~187500|
1016 -|Data bit|8|
1017 -|Parity|Even/ Odd/ None|
1018 -|Stop bit|1/2|
1019 -|Station No.|0~~255|
1577 +(% class="wikigeneratedid" %)
1578 +**4)Cable Wiring**
1020 1020  
1021 -**Address List**
1580 +(% class="wikigeneratedid" id="H" %)
1581 +[[image:image-20220829152610-7.png]]
1022 1022  
1023 -(% class="table-bordered" %)
1024 -|**Type**|**HMI address**|**MODBUS code**|**Range**
1025 -|Bit|HDX3000.0~~HDX3499.15|0|0~~7999
1026 -|Word|HDW3500~~HDW7999|4|0~~4499
1583 +(% class="wikigeneratedid" id="H" %)
1584 +[[image:image-20220829152102-5.png]]
1027 1027  
1028 -**Cable Wiring**
1029 1029  
1030 -* **RS485**
1587 +== **DVP Ethernet Protocol** ==
1031 1031  
1032 -(% style="text-align:center" %)
1033 -[[image:12.PLC Protocol_html_68dfb6d383f0edd9.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1589 +(% class="wikigeneratedid" %)
1590 +Supported Series: Delta DVP ES2/EX2/SS2/SA2/SX2/SE Controller
1034 1034  
1035 -(% style="text-align:center" %)
1036 -[[image:12.PLC Protocol_html_cbeb90cb4faaa8bc.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1592 +**1)HMI Settings**
1037 1037  
1038 -* **RS232**
1594 +|**Items**|**Settings**|**Note**
1595 +|Protocol|DELTA DVP Modbus TCP|
1596 +|Connection|Ethernet|
1597 +|Port No.|201|Must be the same as the PLC setting
1598 +|PLC station No.|0|Must be the same as the PLC setting
1039 1039  
1040 -(% style="text-align:center" %)
1041 -[[image:12.PLC Protocol_html_9030ba679545793b.png||data-xwiki-image-style-alignment="center" height="241" width="387" class="img-thumbnail"]]
1600 +**2)Address List**
1042 1042  
1043 -**✎Note:** COM3 only available in PI8000/PI9000 series.
1602 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1603 +|Bit|X|X|X o|0~~377|
1604 +|Bit|Y|Y|Y o|0~~377|
1605 +|Bit|M0|M0|M0 d|0~~1535|
1606 +|Bit|M1|M1|M1 d|1536~~4095|
1607 +|Bit|T|T|T d|0~~255|
1608 +|Bit|C|C|C d|0~~255|
1609 +|Bit|S|S|S d|0~~1023|
1610 +|Word|D0|D0|D0 d|0~~4095|
1611 +|Word|D1|D1|D1 d|4096~~11999|(((
1612 +
1613 +)))
1614 +|Word|T|T|T d|0~~255|
1615 +|Word|C|C|C d|0~~199|(((
1616 +
1617 +)))
1044 1044  
1045 -== **MODBUS RTU Slave (All function)/(All function OneBaseAddress)** ==
1619 +(% class="wikigeneratedid" %)
1620 +**3)Configure the communication protocol**
1046 1046  
1047 -Supported Series: MODBUS RTU CONTROLLER
1622 +[[image:image-20220829155452-1.png]]
1048 1048  
1049 -HMI works as MODBUS MASTER connecting with SLAVE.
1624 +[[image:image-20220829162116-2.png]]
1050 1050  
1051 -The addresses in [All function] start from 0, while the addresses in [All function OneBaseAddress] start from 1 (offset 1).
1626 +**4)Cable Wiring**
1052 1052  
1053 -(% style="text-align:center" %)
1054 -[[image:12.PLC Protocol_html_7236139c887defad.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]
1628 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1055 1055  
1630 +== **AS serial protocol** ==
1056 1056  
1057 -(% style="text-align:center" %)
1058 -[[image:12.PLC Protocol_html_de80207f2b495c17.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1632 +**1)HMI Settings**
1059 1059  
1060 -
1061 -(% style="text-align:center" %)
1062 -[[image:12.PLC Protocol_html_4e9e8eff81c7ff8b.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1063 -
1064 -**HMI Settings**
1065 -
1066 -(% class="table-bordered" %)
1067 -|**Items**|**Settings**|**Note**
1068 -|Protocol|MODBUS RTU Slave (All function)/( All function OneBaseAddress)|
1069 -|Connection|RS485/RS232|
1070 -|Baud rate|2400~~187500|
1634 +|**Item**|**Settings**|**Note**
1635 +|Protocol|DELTA AS300 MODBUS RTU|
1636 +|Connection|RS485|
1637 +|Baud rate|9600|
1071 1071  |Data bit|8|
1072 -|Parity|Even/ Odd/ None|
1073 -|Stop bit|1/2|
1074 -|PLC station No.|0~~255|
1639 +|Parity|NONE|
1640 +|Stop bit|1|
1641 +|PLC station No.|1|
1075 1075  
1076 -**Address List**
1643 +**2)Address List**
1077 1077  
1078 -(% class="table-bordered" %)
1079 -|**Type**|**Address Type**|**Function code & Description**
1080 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1081 -|06 (write single register: write a binary value to a holding register)
1082 -|10 (write values to multiple addresses )
1083 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
1084 -|06 (write single register: write a binary value to a holding register)
1085 -|10 (write values to multiple addresses )
1086 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
1087 -|06 (write single register: write a binary value to a holding register)
1088 -|10 (write values to multiple addresses )
1089 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
1090 -|10 (write values to multiple addresses )
1091 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
1092 -|05 (Force a single coil to force the on/off state of a logic coil)
1093 -|0F (Write multiple bits, ie write continuously)
1094 -|(% rowspan="3" %)1|02 (Read the input state)
1095 -|05 (Force a single coil to force the on/off state of a logic coil)
1096 -|0F (Write multiple bits)
1097 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
1098 -|05 (Force a single coil to force the on/off state of a logic coil)
1099 -|0F (Write multiple bits)
1100 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1101 -|0F (Write multiple bits)
1102 1102  
1103 -**✎Note:**
1646 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1647 +|Bit|X|X|X d|0~~63|
1648 +|Bit|Y|Y|Y d|0~~63|
1649 +|Bit|D|D|D d|0~~29999|
1650 +|Bit|M|M|M d|0~~8191|
1651 +|Bit|SM|SM|SM d|0~~4095|
1652 +|Bit|S|S|S h|0~~2047|
1653 +|Bit|T|T|T d|0~~511|
1654 +|Bit|C|C|C d|0~~511|
1655 +|Bit|HC|HC|HC d|0~~255|
1656 +|Word|X|X|X h|0~~63|
1657 +|Word|Y|Y|Y d|0~~63|
1658 +|Word|SR|SR|SR d|0~~2047|
1659 +|Word|D|D|D d|0~~29999|
1660 +|Word|T|T|T d|0~~511|
1661 +|Word|C|C|C h|0~~511|
1662 +|Word|E|E|E d|0~~9|
1104 1104  
1105 -* Modbus can also support getting bit from the word, which could access the address such as 100.1 and other formats.
1106 -* The function codes sent out are the same as those that read and write words.
1664 +**3)Configure the communication protocol**
1107 1107  
1108 -**Station number for more than one slaves**
1666 +[[image:image-20220830094600-1.png]]
1109 1109  
1110 -If there are more than one slaves connected to HMI, please set slave station number during editing address, as below shows.
1668 +[[image:image-20220830094657-2.png]]
1111 1111  
1112 -(% style="text-align:center" %)
1113 -[[image:12.PLC Protocol_html_31f028c6d80be344.png||data-xwiki-image-style-alignment="center" height="515" width="485" class="img-thumbnail"]]
1670 +**4)Cable Wiring**
1114 1114  
1115 -**Cable Wiring**
1672 +Figure
1116 1116  
1117 -* **RS485**
1674 +[[image:image-20220830141138-1.png]]
1118 1118  
1119 -(% style="text-align:center" %)
1120 -[[image:12.PLC Protocol_html_68dfb6d383f0edd9.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1676 +Pin Definition Diagram
1121 1121  
1122 -(% style="text-align:center" %)
1123 -[[image:12.PLC Protocol_html_cbeb90cb4faaa8bc.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1678 +[[image:image-20220830095131-1.png]]
1124 1124  
1125 -* **RS232**
1680 +== **AS Ethernet Protocol** ==
1126 1126  
1127 -(% style="text-align:center" %)
1128 -[[image:12.PLC Protocol_html_9030ba679545793b.png||data-xwiki-image-style-alignment="center" height="241" width="387" class="img-thumbnail"]]
1682 +**1)HMI Settings**
1129 1129  
1130 -**✎Note:** COM3 only available in PI8000/PI9000 series.
1131 1131  
1132 -== **MODBUS TCP Slave (All function)** ==
1133 -
1134 -Supported series: MODBUS TCP controller
1135 -
1136 -HMI works as MODBUS TCP MASTER connecting with TCP SLAVE
1137 -
1138 -(% style="text-align:center" %)
1139 -[[image:12.PLC Protocol_html_8877cb7f39c2b607.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]
1140 -
1141 -(% style="text-align:center" %)
1142 -[[image:12.PLC Protocol_html_e7e1f06f127a9175.png||data-xwiki-image-style-alignment="center" height="426" width="553" class="img-thumbnail"]]
1143 -
1144 -
1145 -(% style="text-align:center" %)
1146 -[[image:12.PLC Protocol_html_60bbfe5de79417a6.png||data-xwiki-image-style-alignment="center" height="163" width="553" class="img-thumbnail"]]
1147 -
1148 -**HMI Setting**
1149 -
1150 -(% class="table-bordered" %)
1151 -|**Items**|**Settings**|**Note**
1152 -|Protocol|MODBUS TCP Slave (All function)|
1685 +|=**Items**|=**Settings**|=**Note**
1686 +|Protocol|DELTA AS300 MODBUS TCP|
1153 1153  |Connection|Ethernet|
1154 1154  |Port No.|502|
1155 -|PLC station No.|1|
1689 +|Device No.|1|
1690 +|HMI No.|0|
1156 1156  
1157 -**Address List**
1692 +**2)Address List**
1158 1158  
1159 -(% class="table-bordered" %)
1160 -|**Type**|**Register**|**Function code & Description**
1161 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1162 -|06 (write single register: write a binary value to a holding register)
1163 -|10 (write values to multiple addresses )
1164 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
1165 -|06 (write single register: write a binary value to a holding register)
1166 -|10 (write values to multiple addresses )
1167 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
1168 -|06 (write single register: write a binary value to a holding register)
1169 -|10 (write values to multiple addresses )
1170 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
1171 -|10 (write values to multiple addresses )
1172 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
1173 -|05 (Force a single coil to force the on/off state of a logic coil)
1174 -|0F (Write multiple bits, ie write continuously)
1175 -|(% rowspan="3" %)1|02 (Read the input state)
1176 -|05 (Force a single coil to force the on/off state of a logic coil)
1177 -|0F (Write multiple bits)
1178 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
1179 -|05 (Force a single coil to force the on/off state of a logic coil)
1180 -|0F (Write multiple bits)
1181 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1182 -|0F (Write multiple bits)
1183 1183  
1184 -**Communication Settings**
1695 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1696 +|Bit|X|X|X d|0~~63|
1697 +|Bit|Y|Y|Y d|0~~63|
1698 +|Bit|D|D|D d|0~~29999|
1699 +|Bit|M|M|M d|0~~8191|
1700 +|Bit|SM|SM|SM d|0~~4095|
1701 +|Bit|S|S|S h|0~~2047|
1702 +|Bit|T|T|T d|0~~511|
1703 +|Bit|C|C|C d|0~~511|
1704 +|Bit|HC|HC|HC d|0~~255|
1705 +|Word|X|X|X h|0~~63|
1706 +|Word|Y|Y|Y d|0~~63|
1707 +|Word|SR|SR|SR d|0~~2047|
1708 +|Word|D|D|D d|0~~29999|
1709 +|Word|T|T|T d|0~~511|
1710 +|Word|C|C|C h|0~~511|
1711 +|Word|E|E|E d|0~~9|
1185 1185  
1186 -Enable HMI Ethernet in [Project Settings];
1713 +**3)Configure the communication protocol**
1187 1187  
1188 -(% style="text-align:center" %)
1189 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1715 +[[image:image-20220830140537-1.png]]
1190 1190  
1191 -Set PLC IP in [Device IP] settings;
1717 +[[image:image-20220830140629-2.png]]
1192 1192  
1193 -(% style="text-align:center" %)
1194 -[[image:12.PLC Protocol_html_4bd3cc8348adecf8.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
1719 +**4)Cable Wiring**
1195 1195  
1196 -**Cable Wiring**
1721 +Figure
1197 1197  
1198 -(% style="text-align:center" %)
1199 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1723 +[[image:image-20220830094929-1.png]]
1200 1200  
1201 -= **Omron** =
1725 +Pin Definition Diagram
1202 1202  
1727 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1728 +
1729 += Create communication with **Omron** PLC =
1730 +
1203 1203  == **EC55** ==
1204 1204  
1205 1205  Supported device: EC55 temperature instrument
... ... @@ -1206,7 +1206,6 @@
1206 1206  
1207 1207  **HMI Settings**
1208 1208  
1209 -(% class="table-bordered" %)
1210 1210  |**Items**|**Settings**|**Note**
1211 1211  |Protocol|Omron EC55|
1212 1212  |Connection|RS485 (9600, 2, 7, EVEN)|
... ... @@ -1215,7 +1215,6 @@
1215 1215  
1216 1216  **Address List**
1217 1217  
1218 -(% class="table-bordered" %)
1219 1219  |**Type**|**Register**|**Device range**|**HMI range**|**Function**
1220 1220  |(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0
1221 1221  |C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0
... ... @@ -1261,7 +1261,7 @@
1261 1261  * Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document.
1262 1262  * When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable.
1263 1263  * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
1264 -* (% id="cke_bm_8690S" style="display:none" %)[[image:12.PLC Protocol_html_d428cad280fdefb3.png||height="276" width="347"]](%%)Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1790 +* [[image:12.PLC Protocol_html_d428cad280fdefb3.png||height="276" width="347"]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1265 1265  
1266 1266  == EtherNet/IP NX series ==
1267 1267  
... ... @@ -1269,7 +1269,6 @@
1269 1269  
1270 1270  **HMI Setting**
1271 1271  
1272 -(% class="table-bordered" %)
1273 1273  |**Items**|**Settings**|**Note**
1274 1274  |Protocol|Omron NX Ethernet/IP|
1275 1275  |Connection|Ethernet|
... ... @@ -1321,183 +1321,224 @@
1321 1321  (% style="text-align:center" %)
1322 1322  [[image:12.PLC Protocol_html_437cb087b36b5784.png||data-xwiki-image-style-alignment="center" height="330" width="600" class="img-thumbnail"]]
1323 1323  
1324 -
1325 1325  (% style="text-align:center" %)
1326 1326  [[image:12.PLC Protocol_html_60ef71528a99abf5.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]]
1327 1327  
1328 1328  **Cable Wiring**
1329 1329  
1854 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1855 +
1856 += **MODBUS** =
1857 +
1858 +== **MODBUS RTU Master** ==
1859 +
1860 +Supported Series: MODBUS RTU CONTROLLER
1861 +
1862 +HMI works as MODBUS SLAVE connecting with MASTER
1863 +
1330 1330  (% style="text-align:center" %)
1331 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1865 +[[image:12.PLC Protocol_html_44425b313b0a6b96.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]
1332 1332  
1333 -= **OpenCAN** =
1334 1334  
1335 -OpenCan is based on CAN2.0 standard; OpenCAN protocols that could be configured autonomously to accept and send frames.
1868 +(% style="text-align:center" %)
1869 +[[image:12.PLC Protocol_html_b56b9da32c3caaa.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1336 1336  
1337 -This protocol is only available in PI8000 series HMI.
1338 1338  
1872 +(% style="text-align:center" %)
1873 +[[image:12.PLC Protocol_html_67cd25458b9c72a6.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1874 +
1339 1339  **HMI Settings**
1340 1340  
1341 1341  (% class="table-bordered" %)
1342 1342  |**Items**|**Settings**|**Note**
1343 -|Protocol|OPENCAN|
1344 -|Connection|CAN port|
1345 -|Baud rate|250000|
1879 +|Protocol|MODBUS RTU Master|
1880 +|Connection|RS485/RS232|
1881 +|Baud rate|2400~~187500|
1882 +|Data bit|8|
1883 +|Parity|Even/ Odd/ None|
1884 +|Stop bit|1/2|
1885 +|Station No.|0~~255|
1346 1346  
1347 -**CAN frame setting in HMI**
1887 +**Address List**
1348 1348  
1349 -Click [OpenCAN setting] button in communication setting window;
1889 +(% class="table-bordered" %)
1890 +|**Type**|**HMI address**|**MODBUS code**|**Range**
1891 +|Bit|HDX3000.0~~HDX3499.15|0|0~~7999
1892 +|Word|HDW3500~~HDW7999|4|0~~4499
1350 1350  
1351 -(% style="text-align:center" %)
1352 -[[image:12.PLC Protocol_html_e866b9e56e19785d.png||data-xwiki-image-style-alignment="center" height="503" width="600" class="img-thumbnail"]]
1894 +**Cable Wiring**
1353 1353  
1354 -Click [Add] to create a new frame;
1896 +* **RS485**
1355 1355  
1356 1356  (% style="text-align:center" %)
1357 -[[image:12.PLC Protocol_html_3a6f4e2141763c8f.png||data-xwiki-image-style-alignment="center" height="315" width="600" class="img-thumbnail"]]
1899 +[[image:12.PLC Protocol_html_68dfb6d383f0edd9.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1358 1358  
1359 -(% class="table-bordered" %)
1360 -|**No**|**Items**|**Description**
1361 -|1|Add|add a frame related to register address
1362 -|2|Insert|Select the position where you want to insert a frame, and click [Insert frame] to add a new frame in front of the current frame position
1363 -|3|Frame manager|This list shows some of the main parameters for each frame that the user adds
1364 -|4|Modify|Modify the frames in frame management
1365 -|5|Copy|Copy one frame to another
1366 -|6|Delete|Remove the selected frames from the list by modifying the frames in frame management. If no frames are selected in the list, the first frame is deleted.
1367 -|7|Empty|All frames in the list are cleared
1368 -|8|Browse|Displays configuration files in XML format in IE
1369 -|9|OK|Complete the configuration of the frame and exit
1901 +(% style="text-align:center" %)
1902 +[[image:12.PLC Protocol_html_cbeb90cb4faaa8bc.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1370 1370  
1371 -Set CANBUS frame in setting windows
1904 +* **RS232**
1372 1372  
1373 1373  (% style="text-align:center" %)
1374 -[[image:12.PLC Protocol_html_7c83130820321ef.png||data-xwiki-image-style-alignment="center" height="507" width="600" class="img-thumbnail"]]
1907 +[[image:12.PLC Protocol_html_9030ba679545793b.png||data-xwiki-image-style-alignment="center" height="241" width="387" class="img-thumbnail"]]
1375 1375  
1376 -(% class="table-bordered" %)
1377 -|**No**|(% style="width:185px" %)**Items**|(% style="width:854px" %)**Description**
1378 -|1|(% style="width:185px" %)ID|(% style="width:854px" %)Set the ID of a can frame in hexadecimal format;
1379 -|2|(% style="width:185px" %)ID assign|(% style="width:854px" %)split the ID by PF, PS, and SA;
1380 -|3|(% style="width:185px" %)Frame type|(% style="width:854px" %)Select Standard frame or Extended Frame;
1381 -|4|(% style="width:185px" %)Frame format|(% style="width:854px" %)Select between data frame and remote Frame;
1382 -|5|(% style="width:185px" %)Data|(% style="width:854px" %)Set the data part of CAN frame, with two Numbers representing a hexadecimal number and Spaces spaced; Maximum support of 8 bytes is defined according to CAN message;
1383 -|6|(% style="width:185px" %)Use address|(% style="width:854px" %)(((
1384 -Set the register address related to the CAN frame, which corresponds to the register address set on the main state one by one. The data obtained from the address is assigned continuously;
1909 +**✎Note:** COM3 only available in PI8000/PI9000 series.
1385 1385  
1386 -**Edit:** Set a bit or word address by its format;
1911 +== **MODBUS RTU Slave (All function)/(All function OneBaseAddress)** ==
1387 1387  
1388 -**Option: **Set address options related to frame, enter “register address option” interface, specifically browse the following “register address option” interface;
1389 -)))
1390 -|(% rowspan="8" %)7|(% rowspan="8" style="width:185px" %)Data interactive configuration|(% style="width:854px" %)There are two interactive modes of the touch screen. One is that the touch screen actively sends frames, and the device receives and processes and feeds back. The other, on the contrary, passively receives frames from the device for processing and feedback;
1391 -|(% style="width:854px" %)Send after receiving: if this item is selected, the interaction of the touch screen will act as a passive party, and the touch screen will receive the CAN frame first and send feedback. Unchecked items interact in the opposite way;
1392 -|(% style="width:854px" %)Feedback mode: feedback mode includes no response, confirm response and data response;
1393 -|(% style="width:854px" %)No response: the device or touch screen will not receive feedback;
1394 -|(% style="width:854px" %)Confirm response: the device or the touch screen will receive feedback with confirmation, which could be used to compare the data parts. If this function is used, the 20 addresses before and after this address should not be used. All addresses of cata10-cata30 could not be used with the reply confirmation function of cata20;
1395 -|(% style="width:854px" %)Data response: the device or touch screen will receive feedback with data, and the data to be separated from the feedback frame should be set to store in the register address;
1396 -|(% style="width:854px" %)response ID: if the address wants to receive data on a frame with a different ID, set this, check "different from sender", and enter a different ID in the following input box. Without this setting, the screen will receive and process a frame with the same ID as the sender;
1397 -|(% style="width:854px" %)Response timeout: sets whether the response frame timeout;
1398 -|(% rowspan="3" %)8|(% rowspan="3" style="width:185px" %)Control address|(% style="width:854px" %)If ticked, enable sending when the value of the corresponding control bit number (address) is non-0.
1399 -|(% style="width:854px" %)Control bit: CtrlBit register range 0~~255, if the control bit is ON, can instruction will run normally. Otherwise, it doesn't run;
1400 -|(% style="width:854px" %)Manually send: a manually send tick indicates only one send;
1401 -|9|(% style="width:185px" %)Flag configuration|(% style="width:854px" %)Communication control for each frame. Display OFF when communication is normal, and ON when communication is abnormal;
1402 -|10|(% style="width:185px" %)Note|(% style="width:854px" %)Fill the text to explain the meaning of the frame;
1403 -|11|(% style="width:185px" %)Data assign|(% style="width:854px" %)Preview the display in this table based on the address and the corresponding number of digits;
1404 -|12|(% style="width:185px" %)Current operation display|(% style="width:854px" %)Display the description of current operation;
1405 -|13|(% style="width:185px" %)Add|(% style="width:854px" %)Add a new frame;
1406 -|14|(% style="width:185px" %)Save frame|(% style="width:854px" %)Save the configured frame format;
1407 -|15|(% style="width:185px" %)Cancel|(% style="width:854px" %)Cancel the frame configuration;
1913 +Supported Series: MODBUS RTU CONTROLLER
1408 1408  
1409 -Set CAN address (Read or write operation);
1915 +HMI works as MODBUS MASTER connecting with SLAVE.
1410 1410  
1917 +The addresses in [All function] start from 0, while the addresses in [All function OneBaseAddress] start from 1 (offset 1).
1918 +
1411 1411  (% style="text-align:center" %)
1412 -[[image:12.PLC Protocol_html_7e9f9b25eb6ae8ce.png||data-xwiki-image-style-alignment="center" height="446" width="600" class="img-thumbnail"]]
1920 +[[image:12.PLC Protocol_html_7236139c887defad.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]
1413 1413  
1414 -(% class="table-bordered" %)
1415 -|**No.**|(% style="width:207px" %)**Item**|(% style="width:829px" %)**Description**
1416 -|1|(% style="width:207px" %)Current address|(% style="width:829px" %)Displays the register type and register address set by the user in the data access interface
1417 -|(% rowspan="3" %)2|(% rowspan="3" style="width:207px" %)Trigger|(% style="width:829px" %)Two operations, "read" and "write," are based on on-screen registers
1418 -|(% style="width:829px" %)If "read" is selected, the register address is reading device data in a manner of sending frames set by the user in a loop.
1419 -|(% style="width:829px" %)If "write" is selected, the screen data of the register address will be written into the device. The writing mode is that the user makes a write operation on the screen, which will trigger the sending of a frame set by the user.
1420 -|(% rowspan="5" %)3|(% rowspan="3" style="width:207px" %)Data operation|(% style="width:829px" %)The read and write operations in the trigger conditions are set accordingly.
1421 -|(% style="width:829px" %)If the trigger condition is a read operation, this section needs to set the position and length of the data to be obtained at the current address in the frame.
1422 -|(% style="width:829px" %)If the trigger condition is a writing operation, there are two situations:(((
1423 -* If the "add writing data to the frame" option is not selected, the frame set by the user will be sent directly when the user writes on the screen.
1424 -* Select the "add the written data to the frame" option, and when the user writes on the screen, the program will insert the data in the frame set by the user and send the written data to the frame set by the user according to the data insertion position and length set by the user.
1425 -)))
1426 -|(% rowspan="2" style="width:207px" %)Position and length input format|(% style="width:829px" %)If the register type is a bit address, the decimal point is required to represent the bits in the byte. For example, 1.1 represents the first bit of the first byte of 8 bytes in the data frame, and the length is in bits, and so on.
1427 -|(% style="width:829px" %)If the register type is word address, the integer only needs to represent the byte, such as 1, which represents the first byte of 8-byte data in the data frame, and the unit of length is byte, and so on.
1428 -|4|(% style="width:207px" %)Add|(% style="width:829px" %)Add current configuration
1429 -|5|(% style="width:207px" %)Close|(% style="width:829px" %)Close the configuration window to exit
1430 1430  
1431 -**Multiple Packages Settings**
1923 +(% style="text-align:center" %)
1924 +[[image:12.PLC Protocol_html_de80207f2b495c17.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1432 1432  
1926 +
1433 1433  (% style="text-align:center" %)
1434 -[[image:12.PLC Protocol_html_107e0f6b1a90afff.png||data-xwiki-image-style-alignment="center" height="341" width="600" class="img-thumbnail"]]
1928 +[[image:12.PLC Protocol_html_4e9e8eff81c7ff8b.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1435 1435  
1436 -Check [Multiple packages supported] to open [Multiple package data] window, as below show.
1930 +**HMI Settings**
1437 1437  
1438 -Select Multiple package type
1932 +(% class="table-bordered" %)
1933 +|**Items**|**Settings**|**Note**
1934 +|Protocol|MODBUS RTU Slave (All function)/( All function OneBaseAddress)|
1935 +|Connection|RS485/RS232|
1936 +|Baud rate|2400~~187500|
1937 +|Data bit|8|
1938 +|Parity|Even/ Odd/ None|
1939 +|Stop bit|1/2|
1940 +|PLC station No.|0~~255|
1439 1439  
1440 -* Not Multiple packages
1441 -* J1939 Multiple packages
1442 -* Customized Multiple packages
1942 +**Address List**
1443 1443  
1444 -Click [Edit Receive data] for [Receive] settings
1944 +(% class="table-bordered" %)
1945 +|**Type**|**Address Type**|**Function code & Description**
1946 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1947 +|06 (write single register: write a binary value to a holding register)
1948 +|10 (write values to multiple addresses )
1949 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
1950 +|06 (write single register: write a binary value to a holding register)
1951 +|10 (write values to multiple addresses )
1952 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
1953 +|06 (write single register: write a binary value to a holding register)
1954 +|10 (write values to multiple addresses )
1955 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
1956 +|10 (write values to multiple addresses )
1957 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
1958 +|05 (Force a single coil to force the on/off state of a logic coil)
1959 +|0F (Write multiple bits, ie write continuously)
1960 +|(% rowspan="3" %)1|02 (Read the input state)
1961 +|05 (Force a single coil to force the on/off state of a logic coil)
1962 +|0F (Write multiple bits)
1963 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
1964 +|05 (Force a single coil to force the on/off state of a logic coil)
1965 +|0F (Write multiple bits)
1966 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1967 +|0F (Write multiple bits)
1445 1445  
1446 -* Start code+ Total length (J1939)
1969 +**✎Note:**
1447 1447  
1448 -(% style="text-align:center" %)
1449 -[[image:12.PLC Protocol_html_3c360c6b5aca51bf.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]]
1971 +* Modbus can also support getting bit from the word, which could access the address such as 100.1 and other formats.
1972 +* The function codes sent out are the same as those that read and write words.
1450 1450  
1451 -As set above set, J1939 command is received by the HMI, only when its length is 25 bytes, and the start code is 0x57, 0x1B;
1974 +**Station number for more than one slaves**
1452 1452  
1453 -* Start code + Data max length (J1939)
1976 +If there are more than one slaves connected to HMI, please set slave station number during editing address, as below shows.
1454 1454  
1455 1455  (% style="text-align:center" %)
1456 -[[image:12.PLC Protocol_html_74496b2a68cfcdde.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]]
1979 +[[image:12.PLC Protocol_html_31f028c6d80be344.png||data-xwiki-image-style-alignment="center" height="515" width="485" class="img-thumbnail"]]
1457 1457  
1458 -As set above set, J1939 command is received by the HMI, only when its length less than 50 bytes, and the start code is 0x57, 0x1B;
1981 +**Cable Wiring**
1459 1459  
1460 -* Data max length (J1939)
1983 +* **RS485**
1461 1461  
1462 1462  (% style="text-align:center" %)
1463 -[[image:12.PLC Protocol_html_98cea3e7cbd8f05d.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]]
1986 +[[image:12.PLC Protocol_html_68dfb6d383f0edd9.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1464 1464  
1465 -As set above set, J1939 command is received by the HMI, only when its length less than 50 bytes.
1988 +(% style="text-align:center" %)
1989 +[[image:12.PLC Protocol_html_cbeb90cb4faaa8bc.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1466 1466  
1467 -* Customized multiple package
1991 +* **RS232**
1468 1468  
1469 1469  (% style="text-align:center" %)
1470 -[[image:12.PLC Protocol_html_4635bbe4d7999db0.png||data-xwiki-image-style-alignment="center" height="395" width="367" class="img-thumbnail"]]
1994 +[[image:12.PLC Protocol_html_9030ba679545793b.png||data-xwiki-image-style-alignment="center" height="241" width="387" class="img-thumbnail"]]
1471 1471  
1472 -As set above, It is received by the HMI, when the first frame starts with 0X57 0X1B, and the sum of the data lengths of multiple frames is equal to 79 bytes.
1996 +**✎Note:** COM3 only available in PI8000/PI9000 series.
1473 1473  
1474 -Click [Edit Send data] for [Send] setting
1998 +== **MODBUS TCP Slave (All function)** ==
1475 1475  
1476 -* J1939
2000 +Supported series: MODBUS TCP controller
1477 1477  
2002 +HMI works as MODBUS TCP MASTER connecting with TCP SLAVE
2003 +
1478 1478  (% style="text-align:center" %)
1479 -[[image:12.PLC Protocol_html_a4769e44331ca732.png||data-xwiki-image-style-alignment="center" height="280" width="463" class="img-thumbnail"]]
2005 +[[image:12.PLC Protocol_html_8877cb7f39c2b607.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]
1480 1480  
1481 -[Data] is all data to be sent.
2007 +(% style="text-align:center" %)
2008 +[[image:12.PLC Protocol_html_e7e1f06f127a9175.png||data-xwiki-image-style-alignment="center" height="426" width="553" class="img-thumbnail"]]
1482 1482  
1483 -Since the frame of the J1939 frame contains the number of the data packet, so the data sent is: the first byte (number) + 7 bytes of data. If it is less than 7 bytes, it is sent in the actual number of bytes.
1484 1484  
1485 -* Customized multiple package
2011 +(% style="text-align:center" %)
2012 +[[image:12.PLC Protocol_html_60bbfe5de79417a6.png||data-xwiki-image-style-alignment="center" height="163" width="553" class="img-thumbnail"]]
1486 1486  
2014 +**HMI Setting**
2015 +
2016 +(% class="table-bordered" %)
2017 +|**Items**|**Settings**|**Note**
2018 +|Protocol|MODBUS TCP Slave (All function)|
2019 +|Connection|Ethernet|
2020 +|Port No.|502|
2021 +|PLC station No.|1|
2022 +
2023 +**Address List**
2024 +
2025 +(% class="table-bordered" %)
2026 +|**Type**|**Register**|**Function code & Description**
2027 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
2028 +|06 (write single register: write a binary value to a holding register)
2029 +|10 (write values to multiple addresses )
2030 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
2031 +|06 (write single register: write a binary value to a holding register)
2032 +|10 (write values to multiple addresses )
2033 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
2034 +|06 (write single register: write a binary value to a holding register)
2035 +|10 (write values to multiple addresses )
2036 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
2037 +|10 (write values to multiple addresses )
2038 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
2039 +|05 (Force a single coil to force the on/off state of a logic coil)
2040 +|0F (Write multiple bits, ie write continuously)
2041 +|(% rowspan="3" %)1|02 (Read the input state)
2042 +|05 (Force a single coil to force the on/off state of a logic coil)
2043 +|0F (Write multiple bits)
2044 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
2045 +|05 (Force a single coil to force the on/off state of a logic coil)
2046 +|0F (Write multiple bits)
2047 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
2048 +|0F (Write multiple bits)
2049 +
2050 +**Communication Settings**
2051 +
2052 +Enable HMI Ethernet in [Project Settings];
2053 +
1487 1487  (% style="text-align:center" %)
1488 -[[image:12.PLC Protocol_html_78546f765d6f3deb.png||data-xwiki-image-style-alignment="center" height="280" width="463"]]
2055 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1489 1489  
1490 -[Data] is all data to be sent.
2057 +Set PLC IP in [Device IP] settings;
1491 1491  
1492 -As set above, fist frame length is 2 bytes, and others are sent with 6 bytes for every frame, if the last frame is less than 6 bytes, send according to the actual length.
2059 +(% style="text-align:center" %)
2060 +[[image:12.PLC Protocol_html_4bd3cc8348adecf8.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
1493 1493  
1494 1494  **Cable Wiring**
1495 1495  
1496 1496  (% style="text-align:center" %)
1497 -[[image:12.PLC Protocol_html_fccede84efcbdc22.png||data-xwiki-image-style-alignment="center" height="111" width="391" class="img-thumbnail"]]
2065 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1498 1498  
1499 -**✎Note:** The address interval between each frame need to be more than a word address;
1500 -
1501 1501  = **SHIMADEN** =
1502 1502  
1503 1503  == **FP23** ==
... ... @@ -1672,559 +1672,6 @@
1672 1672  
1673 1673  **✎Note:** COM3 only available in PI8000/PI9000 series.
1674 1674  
1675 -= **Siemens** =
1676 -
1677 -== **S7-200 Smart Ethernet** ==
1678 -
1679 -Supported Series: Siemens S7-200 SMART Series Ethernet Module.
1680 -
1681 -Website: [[http:~~/~~/www.siemens.com/entry/cc/en/>>url:http://www.siemens.com/entry/cc/en/]]
1682 -
1683 -**HMI Setting**
1684 -
1685 -(% class="table-bordered" %)
1686 -|**Items**|**Settings**|**Note**
1687 -|Protocol|Simens S7-200 Smart Ethernet|
1688 -|Connection|Ethernet|
1689 -|Port No.|102|
1690 -|PLC station No.|2|
1691 -
1692 -**Address List**
1693 -
1694 -(% class="table-bordered" %)
1695 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
1696 -|(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
1697 -|Q|Q|Q ddddd.o|0.0~~99999.7|
1698 -|V|VWbit|VWbit ddddd.o|0.0~~99999.7|
1699 -|V|V|V ddddd.o|0.0~~99999.7|
1700 -|M|M|M ddddd.o|0.0~~99999.7|
1701 -|SM|SM|ddddd.o|0.0~~99999.7|
1702 -|S|S|ddddd.o|0.0~~99999.7|Read only
1703 -|T|T|ddddd|0~~99999|Timer state, read only
1704 -|C|C|ddddd|0~~99999|Counter state, read only
1705 -|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999|
1706 -|Q|QW|QW ddddd|0~~99999|
1707 -|AI|AIW|AIW ddddd|0~~99999|
1708 -|AQ|VB|VB ddddd|0~~99999|
1709 -|V|VW|VW ddddd|0~~99998|(((
1710 -VW0=VB (0~~1)
1711 -
1712 -VW2=VB (2~~3)
1713 -
1714 -Address value is a multiple of 2
1715 -)))
1716 -|V|VD|VD ddddd|0~~99998|(((
1717 -VD0=VB (0~~3)
1718 -
1719 -VD2=VB (4~~7)
1720 -
1721 -Address value is a multiple of 4
1722 -)))
1723 -|M|MB|MB ddddd|0~~99999|
1724 -|M|MW|MW ddddd|0~~99999|(((
1725 -MW0=MB(0~~1)
1726 -
1727 -MW2=MB(2~~3)
1728 -
1729 -Address value is a multiple of 2
1730 -)))
1731 -|M|MD|MD ddddd|0~~99999|(((
1732 -MD0=MB(0~~3)
1733 -
1734 -MD4=MB(4~~7)
1735 -
1736 -Address value is a multiple of 4
1737 -)))
1738 -|T|TW|TW ddddd|0~~99999|Value of timer
1739 -|C|CW|CW ddddd|0~~99999|Value of counter
1740 -|W|SW|SW ddddd|0~~99999|
1741 -
1742 -**Communication Settings**
1743 -
1744 -Enable HMI Ethernet in [Project Settings];
1745 -
1746 -(% style="text-align:center" %)
1747 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1748 -
1749 -Set PLC IP in [Device IP] settings;
1750 -
1751 -(% style="text-align:center" %)
1752 -[[image:12.PLC Protocol_html_70b0c4c2ee21b10d.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
1753 -
1754 -* PLC IP Address: PLC IP
1755 -* PLC pot No.: 102(fixed)
1756 -* Network:TCP_Client_2N(fixed)
1757 -
1758 -(% style="text-align:center" %)
1759 -[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
1760 -
1761 -* Wait timeout: depend on actual network situation (more than 1500 ms)
1762 -
1763 -**Cable Wiring**
1764 -
1765 -(% style="text-align:center" %)
1766 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1767 -
1768 -== **S7-300 Ethernet** ==
1769 -
1770 -Supported Series: Siemens S7-300 series PLC
1771 -
1772 -**HMI Setting**
1773 -
1774 -(% class="table-bordered" %)
1775 -|**Items**|**Settings**|**Note**
1776 -|Protocol|Simens S7-300 Ethernet|
1777 -|Connection|Ethernet|
1778 -|Port No.|102|
1779 -|PLC station No.|2|Need to be same as the PLC setting
1780 -
1781 -**Address List**
1782 -
1783 -(% class="table-bordered" %)
1784 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
1785 -|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
1786 -|Q|Q|Q ddddd.o|0.0~~99999.7|
1787 -|M|M|M ddddd.o|0.0~~99999.7|
1788 -|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
1789 -nn: block number;
1790 -
1791 -dddd: address;
1792 -)))
1793 -|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
1794 -|Q|QW|QW ddddd|0~~99999|
1795 -|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
1796 -|MW|MW ddddd|0~~99999|(((
1797 -MW0=MB(0~~1)
1798 -
1799 -MW2=MB(2~~3)
1800 -
1801 -Address value is a multiple of 2
1802 -)))
1803 -|MD|MD ddddd|0~~99999|(((
1804 -MD0=MB(0~~3)
1805 -
1806 -MD4=MB(4~~7)
1807 -
1808 -Address value is a multiple of 4
1809 -)))
1810 -|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
1811 -nn: block number;
1812 -
1813 -dddd: address
1814 -)))
1815 -|DBxDBW|DBxDBW nndddd|0~~99999999
1816 -|DBxDBD|DBxDBD nndddd|0~~99999999
1817 -
1818 -**Communication Settings**
1819 -
1820 -Enable HMI Ethernet in [Project Settings];
1821 -
1822 -(% style="text-align:center" %)
1823 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1824 -
1825 -Set PLC IP in [Device IP] settings;
1826 -
1827 -(% style="text-align:center" %)
1828 -[[image:12.PLC Protocol_html_910b1a0aa9e2201c.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]]
1829 -
1830 -* PLC IP Address: PLC IP
1831 -* PLC pot No.: 102(fixed)
1832 -* Network:TCP_Client_2N(fixed)
1833 -
1834 -(% style="text-align:center" %)
1835 -[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
1836 -
1837 -* Wait timeout: depend on actual network situation (more than 1500 ms)
1838 -
1839 -**Cable Wiring**
1840 -
1841 -(% style="text-align:center" %)
1842 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1843 -
1844 -== **S7-1200 Ethernet** ==
1845 -
1846 -Supported Series: Siemens S7-1200
1847 -
1848 -**HMI Setting**
1849 -
1850 -(% class="table-bordered" %)
1851 -|**Items**|**Settings**|**Note**
1852 -|Protocol|Siemens S7-1200|
1853 -|Connection|Ethernet|
1854 -|Port No.|102|
1855 -|PLC station No.|2|
1856 -
1857 -**Address List**
1858 -
1859 -(% class="table-bordered" %)
1860 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
1861 -|(% rowspan="4" %)Bit|I|I|M d.o|(((
1862 -d:0~-~-9999
1863 -
1864 -o:0-7
1865 -)))|
1866 -|Q|Q|Q d.o|(((
1867 -d:0~-~-9999
1868 -
1869 -o:0-7
1870 -)))|
1871 -|M|M|M d.o|(((
1872 -d:0~-~-9999
1873 -
1874 -o:0-7
1875 -)))|
1876 -|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
1877 -nn:0-9999,
1878 -
1879 -dddd:0-9999,
1880 -
1881 -o:0-7
1882 -)))|(((
1883 -nn:DB No.
1884 -
1885 -dddd:address value
1886 -
1887 -o: digit address
1888 -)))
1889 -|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
1890 -|M|MW|MW d|d:0-99999|(((
1891 -MW0=MB(0~~1)
1892 -
1893 -MW2=MB(2~~3)
1894 -
1895 -Address value is a multiple of 2
1896 -)))
1897 -|M|MD|MD d|d:0-99999|(((
1898 -MD0=MB(0~~3)
1899 -
1900 -MD4=MB(4~~7)
1901 -
1902 -Address value is a multiple of 4
1903 -)))
1904 -|I|IW|IW d|d:0-99999|
1905 -|Q|QW|QW d|d:0-99999|
1906 -|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
1907 -nn:0-9999
1908 -
1909 -dddd:0-9999
1910 -)))|(((
1911 -nn:DB No.
1912 -
1913 -dddd:address value
1914 -)))
1915 -|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
1916 -nn:0-9999
1917 -
1918 -dddd:0-9999
1919 -)))|(((
1920 -nn:DB No.
1921 -
1922 -dddd:address value
1923 -
1924 -Address value is a multiple of 2
1925 -)))
1926 -|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
1927 -nn:0-9999
1928 -
1929 -dddd:0-9999
1930 -)))|(((
1931 -nn:DB No.
1932 -
1933 -dddd:address value
1934 -
1935 -Address value is a multiple of 4
1936 -)))
1937 -
1938 -**Communication Settings**
1939 -
1940 -Enable HMI Ethernet in [Project Settings];
1941 -
1942 -(% style="text-align:center" %)
1943 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1944 -
1945 -Set PLC IP in [Device IP] settings;
1946 -
1947 -(% style="text-align:center" %)
1948 -[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
1949 -
1950 -**✎Note:**
1951 -
1952 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
1953 -* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
1954 -
1955 -**PLC Settings**
1956 -
1957 -Add BD
1958 -
1959 -* Please uncheck [Symbolic access only] option;
1960 -
1961 -(% style="text-align:center" %)
1962 -[[image:12.PLC Protocol_html_643144c591994418.png||data-xwiki-image-style-alignment="center" height="546" width="550" class="img-thumbnail"]]
1963 -
1964 -Address settings, using BD2 as example.
1965 -
1966 -* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1.
1967 -* 2 represent DB block number
1968 -* xxxx represent address
1969 -
1970 -**Such as:**
1971 -
1972 -* DBxDBB20000 = DB2.DBB0
1973 -* DBxDBW20004 = DB2.DBW4
1974 -
1975 -(% style="text-align:center" %)
1976 -[[image:12.PLC Protocol_html_87ceaea84d552e62.png||data-xwiki-image-style-alignment="center" height="245" width="537" class="img-thumbnail"]]
1977 -
1978 -**How to connect with S7-1200 Firmware V4.0**
1979 -
1980 -PLC configuration
1981 -
1982 -* Double click [device configuration] in Siemens via software
1983 -* Double click [protection] to enter protection configuration screen
1984 -
1985 -(% style="text-align:center" %)
1986 -[[image:12.PLC Protocol_html_9779940d38da8e07.png||data-xwiki-image-style-alignment="center" height="426" width="341" class="img-thumbnail"]]
1987 -
1988 -* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)]
1989 -
1990 -(% style="text-align:center" %)
1991 -[[image:12.PLC Protocol_html_d2c667b02f9720b1.png||data-xwiki-image-style-alignment="center" height="296" width="554" class="img-thumbnail"]]
1992 -
1993 -DB settings
1994 -
1995 -* Right click [DB], select [properties]
1996 -* Uncheck [optimized block access]
1997 -
1998 -**Cable Wiring**
1999 -
2000 -(% style="text-align:center" %)
2001 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2002 -
2003 -== **LOGO Ethernet** ==
2004 -
2005 -Supported Series: Siemens Logo 0BA0 series
2006 -
2007 -**HMI Settings**
2008 -
2009 -(% class="table-bordered" %)
2010 -|**Items**|**Settings**|**Note**
2011 -|Protocol|Siemens LOGO|
2012 -|Connection|Ethernet|
2013 -|Port No.|102|
2014 -|PLC station No.|2|
2015 -
2016 -**Address List**
2017 -
2018 -(% class="table-bordered" %)
2019 -|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
2020 -|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
2021 -|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
2022 -|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
2023 -|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
2024 -|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
2025 -|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
2026 -|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
2027 -|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
2028 -|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
2029 -|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
2030 -|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
2031 -|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
2032 -|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
2033 -|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
2034 -|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
2035 -
2036 -**PLC Settings in LOGO Software:**
2037 -
2038 -Click [Tools]~-~-[Ethernet Connections],shown as below.
2039 -
2040 -(% style="text-align:center" %)
2041 -[[image:12.PLC Protocol_html_8b9d2322edf89519.png||data-xwiki-image-style-alignment="center" height="641" width="423" class="img-thumbnail"]]
2042 -
2043 -Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
2044 -
2045 -(% style="text-align:center" %)
2046 -[[image:12.PLC Protocol_html_6c4dd041b26cd8a1.png||data-xwiki-image-style-alignment="center" height="481" width="363" class="img-thumbnail"]]
2047 -
2048 -**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
2049 -
2050 -(% style="text-align:center" %)
2051 -[[image:12.PLC Protocol_html_7af2611d3790a77d.png||data-xwiki-image-style-alignment="center" height="359" width="426" class="img-thumbnail"]]
2052 -
2053 -**Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
2054 -
2055 -(% style="text-align:center" %)
2056 -[[image:12.PLC Protocol_html_3243e4cd600595cc.png||data-xwiki-image-style-alignment="center" height="368" width="554" class="img-thumbnail"]]
2057 -
2058 -
2059 -(% style="text-align:center" %)
2060 -[[image:12.PLC Protocol_html_cb1d92e2cc91a8db.png||data-xwiki-image-style-alignment="center" height="320" width="553" class="img-thumbnail"]]
2061 -
2062 -
2063 -**HMI Communication Settings**
2064 -
2065 -Set PLC IP in [Device IP] settings;
2066 -
2067 -(% style="text-align:center" %)
2068 -[[image:SiemensLOGODeviceIP.png]]
2069 -
2070 -Enable HMI Ethernet in [Project Settings];
2071 -
2072 -(% style="text-align:center" %)
2073 -[[image:12.PLC Protocol_html_95917a3d92068467.png||data-xwiki-image-style-alignment="center" height="311" width="553" class="img-thumbnail"]]
2074 -
2075 -TSAP setting
2076 -
2077 -* Regarding the setting of PLC TSAP, HMI provides system special address for setting, it is recommended to run in HMI script initialization, write PLC TSAP to corresponding system special register.
2078 -* HSW10118 = local TSAP of HMI, this is remote TSAP of PLC.
2079 -* HSW10119 = Remote TSAP of HMI, this is local TSAP of PLC.
2080 -
2081 -**✎Note:**
2082 -
2083 -* The data of TSAP is hexadecimal format. For example: the remote TSAP configured in the PLC is set to 20.00, then HSW10118 should be set to 0x2000, that is, HSW10118 = 8192.
2084 -
2085 -(% style="text-align:center" %)
2086 -[[image:12.PLC Protocol_html_5c6374b21f46e01e.png||data-xwiki-image-style-alignment="center" height="139" width="498" class="img-thumbnail"]]
2087 -
2088 -
2089 -* AI word address and Ibit address are read-only and cannot be written on HMI.
2090 -* VW address should be even number.such as VW0, VW2, VW4...
2091 -* VD address it takes two VW addresses.such as VD0,VD4,VD8...
2092 -* Written value of RTC cannot exceed 255.
2093 -
2094 -**Cable Wiring**
2095 -
2096 -(% style="text-align:center" %)
2097 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2098 -
2099 -== **S7-XXX Ethernet** ==
2100 -
2101 -Supported Series: Siemens S7-400, S7-1200 and S7-1500
2102 -
2103 -**HMI Setting**
2104 -
2105 -(% class="table-bordered" style="width:823px" %)
2106 -|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note**
2107 -|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %)
2108 -|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %)
2109 -|Port No.|(% style="width:437px" %)102|(% style="width:201px" %)
2110 -|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %)
2111 -|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %)
2112 -
2113 -Slot from TIA Portal is equal to Device No. of PIStudio
2114 -
2115 -Rack from TIA Portal is equal to HMI No. of PIStudio
2116 -
2117 -(% style="text-align:center" %)
2118 -[[image:S7-XXXCommunication Settings.png]]
2119 -
2120 -(% style="text-align:center" %)
2121 -[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]]
2122 -
2123 -**Address List**
2124 -
2125 -(% class="table-bordered" %)
2126 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
2127 -|(% rowspan="4" %)Bit|I|I|M d.o|(((
2128 -d:0~-~-9999
2129 -
2130 -o:0-7
2131 -)))|
2132 -|Q|Q|Q d.o|(((
2133 -d:0~-~-9999
2134 -
2135 -o:0-7
2136 -)))|
2137 -|M|M|M d.o|(((
2138 -d:0~-~-9999
2139 -
2140 -o:0-7
2141 -)))|
2142 -|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
2143 -nn:0-9999,
2144 -
2145 -dddd:0-9999,
2146 -
2147 -o:0-7
2148 -)))|(((
2149 -nn:DB No.
2150 -
2151 -dddd:address value
2152 -
2153 -o: digit address
2154 -)))
2155 -|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
2156 -|M|MW|MW d|d:0-99999|(((
2157 -MW0=MB(0~~1)
2158 -
2159 -MW2=MB(2~~3)
2160 -
2161 -Address value is a multiple of 2
2162 -)))
2163 -|M|MD|MD d|d:0-99999|(((
2164 -MD0=MB(0~~3)
2165 -
2166 -MD4=MB(4~~7)
2167 -
2168 -Address value is a multiple of 4
2169 -)))
2170 -|I|IW|IW d|d:0-99999|
2171 -|Q|QW|QW d|d:0-99999|
2172 -|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
2173 -nn:0-9999
2174 -
2175 -dddd:0-9999
2176 -)))|(((
2177 -nn:DB No.
2178 -
2179 -dddd:address value
2180 -)))
2181 -|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
2182 -nn:0-9999
2183 -
2184 -dddd:0-9999
2185 -)))|(((
2186 -nn:DB No.
2187 -
2188 -dddd:address value
2189 -
2190 -Address value is a multiple of 2
2191 -)))
2192 -|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
2193 -nn:0-9999
2194 -
2195 -dddd:0-9999
2196 -)))|(((
2197 -nn:DB No.
2198 -
2199 -dddd:address value
2200 -
2201 -Address value is a multiple of 4
2202 -)))
2203 -
2204 -**Communication Settings**
2205 -
2206 -Enable HMI Ethernet in [Project Settings];
2207 -
2208 -(% style="text-align:center" %)
2209 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]]
2210 -
2211 -Set PLC IP in [Device IP] settings;
2212 -
2213 -(% style="text-align:center" %)
2214 -[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
2215 -
2216 -**✎Note:**
2217 -
2218 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
2219 -* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
2220 -
2221 -**Cable Wiring**
2222 -
2223 -{{id name="OLE_LINK8"/}}
2224 -
2225 -(% style="text-align:center" %)
2226 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2227 -
2228 2228  = **User Defined Protocol** =
2229 2229  
2230 2230  If the device does not support MODBUS standard, and the protocol is not list in PIStudio, then user can define the protocol by following instruction to realize simply communication functions like sending and receiving commands.
... ... @@ -2848,3 +2848,170 @@
2848 2848  [[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
2849 2849  
2850 2850  **Cable Wiring**
2864 +
2865 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
2866 +
2867 +
2868 += **OpenCAN** =
2869 +
2870 +OpenCan is based on CAN2.0 standard; OpenCAN protocols that could be configured autonomously to accept and send frames.
2871 +
2872 +This protocol is only available in PI8000 series HMI.
2873 +
2874 +**HMI Settings**
2875 +
2876 +|**Items**|**Settings**|**Note**
2877 +|Protocol|OPENCAN|
2878 +|Connection|CAN port|
2879 +|Baud rate|250000|
2880 +
2881 +**CAN frame setting in HMI**
2882 +
2883 +Click [OpenCAN setting] button in communication setting window;
2884 +
2885 +(% style="text-align:center" %)
2886 +[[image:12.PLC Protocol_html_e866b9e56e19785d.png||data-xwiki-image-style-alignment="center" height="503" width="600" class="img-thumbnail"]]
2887 +
2888 +Click [Add] to create a new frame;
2889 +
2890 +(% style="text-align:center" %)
2891 +[[image:12.PLC Protocol_html_3a6f4e2141763c8f.png||data-xwiki-image-style-alignment="center" height="315" width="600" class="img-thumbnail"]]
2892 +
2893 +|**No**|**Items**|**Description**
2894 +|1|Add|add a frame related to register address
2895 +|2|Insert|Select the position where you want to insert a frame, and click [Insert frame] to add a new frame in front of the current frame position
2896 +|3|Frame manager|This list shows some of the main parameters for each frame that the user adds
2897 +|4|Modify|Modify the frames in frame management
2898 +|5|Copy|Copy one frame to another
2899 +|6|Delete|Remove the selected frames from the list by modifying the frames in frame management. If no frames are selected in the list, the first frame is deleted.
2900 +|7|Empty|All frames in the list are cleared
2901 +|8|Browse|Displays configuration files in XML format in IE
2902 +|9|OK|Complete the configuration of the frame and exit
2903 +
2904 +Set CANBUS frame in setting windows
2905 +
2906 +(% style="text-align:center" %)
2907 +[[image:12.PLC Protocol_html_7c83130820321ef.png||data-xwiki-image-style-alignment="center" height="507" width="600" class="img-thumbnail"]]
2908 +
2909 +|**No**|**Items**|**Description**
2910 +|1|ID|Set the ID of a can frame in hexadecimal format;
2911 +|2|ID assign|split the ID by PF, PS, and SA;
2912 +|3|Frame type|Select Standard frame or Extended Frame;
2913 +|4|Frame format|Select between data frame and remote Frame;
2914 +|5|Data|Set the data part of CAN frame, with two Numbers representing a hexadecimal number and Spaces spaced; Maximum support of 8 bytes is defined according to CAN message;
2915 +|6|Use address|(((
2916 +Set the register address related to the CAN frame, which corresponds to the register address set on the main state one by one. The data obtained from the address is assigned continuously;
2917 +
2918 +**Edit:** Set a bit or word address by its format;
2919 +
2920 +**Option: **Set address options related to frame, enter “register address option” interface, specifically browse the following “register address option” interface;
2921 +)))
2922 +|(% rowspan="8" %)7|(% rowspan="8" %)Data interactive configuration|There are two interactive modes of the touch screen. One is that the touch screen actively sends frames, and the device receives and processes and feeds back. The other, on the contrary, passively receives frames from the device for processing and feedback;
2923 +|Send after receiving: if this item is selected, the interaction of the touch screen will act as a passive party, and the touch screen will receive the CAN frame first and send feedback. Unchecked items interact in the opposite way;
2924 +|Feedback mode: feedback mode includes no response, confirm response and data response;
2925 +|No response: the device or touch screen will not receive feedback;
2926 +|Confirm response: the device or the touch screen will receive feedback with confirmation, which could be used to compare the data parts. If this function is used, the 20 addresses before and after this address should not be used. All addresses of cata10-cata30 could not be used with the reply confirmation function of cata20;
2927 +|Data response: the device or touch screen will receive feedback with data, and the data to be separated from the feedback frame should be set to store in the register address;
2928 +|response ID: if the address wants to receive data on a frame with a different ID, set this, check "different from sender", and enter a different ID in the following input box. Without this setting, the screen will receive and process a frame with the same ID as the sender;
2929 +|Response timeout: sets whether the response frame timeout;
2930 +|(% rowspan="3" %)8|(% rowspan="3" %)Control address|If ticked, enable sending when the value of the corresponding control bit number (address) is non-0.
2931 +|Control bit: CtrlBit register range 0~~255, if the control bit is ON, can instruction will run normally. Otherwise, it doesn't run;
2932 +|Manually send: a manually send tick indicates only one send;
2933 +|9|Flag configuration|Communication control for each frame. Display OFF when communication is normal, and ON when communication is abnormal;
2934 +|10|Note|Fill the text to explain the meaning of the frame;
2935 +|11|Data assign|Preview the display in this table based on the address and the corresponding number of digits;
2936 +|12|Current operation display|Display the description of current operation;
2937 +|13|Add|Add a new frame;
2938 +|14|Save frame|Save the configured frame format;
2939 +|15|Cancel|Cancel the frame configuration;
2940 +
2941 +Set CAN address (Read or write operation);
2942 +
2943 +(% style="text-align:center" %)
2944 +[[image:12.PLC Protocol_html_7e9f9b25eb6ae8ce.png||data-xwiki-image-style-alignment="center" height="446" width="600" class="img-thumbnail"]]
2945 +
2946 +|**No.**|**Item**|**Description**
2947 +|1|Current address|Displays the register type and register address set by the user in the data access interface
2948 +|(% rowspan="3" %)2|(% rowspan="3" %)Trigger|Two operations, "read" and "write," are based on on-screen registers
2949 +|If "read" is selected, the register address is reading device data in a manner of sending frames set by the user in a loop.
2950 +|If "write" is selected, the screen data of the register address will be written into the device. The writing mode is that the user makes a write operation on the screen, which will trigger the sending of a frame set by the user.
2951 +|(% rowspan="5" %)3|(% rowspan="3" %)Data operation|The read and write operations in the trigger conditions are set accordingly.
2952 +|If the trigger condition is a read operation, this section needs to set the position and length of the data to be obtained at the current address in the frame.
2953 +|If the trigger condition is a writing operation, there are two situations:(((
2954 +* If the "add writing data to the frame" option is not selected, the frame set by the user will be sent directly when the user writes on the screen.
2955 +* Select the "add the written data to the frame" option, and when the user writes on the screen, the program will insert the data in the frame set by the user and send the written data to the frame set by the user according to the data insertion position and length set by the user.
2956 +)))
2957 +|(% rowspan="2" %)Position and length input format|If the register type is a bit address, the decimal point is required to represent the bits in the byte. For example, 1.1 represents the first bit of the first byte of 8 bytes in the data frame, and the length is in bits, and so on.
2958 +|If the register type is word address, the integer only needs to represent the byte, such as 1, which represents the first byte of 8-byte data in the data frame, and the unit of length is byte, and so on.
2959 +|4|Add|Add current configuration
2960 +|5|Close|Close the configuration window to exit
2961 +
2962 +**Multiple Packages Settings**
2963 +
2964 +(% style="text-align:center" %)
2965 +[[image:12.PLC Protocol_html_107e0f6b1a90afff.png||data-xwiki-image-style-alignment="center" height="341" width="600" class="img-thumbnail"]]
2966 +
2967 +Check [Multiple packages supported] to open [Multiple package data] window, as below show.
2968 +
2969 +Select Multiple package type
2970 +
2971 +* Not Multiple packages
2972 +* J1939 Multiple packages
2973 +* Customized Multiple packages
2974 +
2975 +Click [Edit Receive data] for [Receive] settings
2976 +
2977 +* Start code+ Total length (J1939)
2978 +
2979 +(% style="text-align:center" %)
2980 +[[image:12.PLC Protocol_html_3c360c6b5aca51bf.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]]
2981 +
2982 +As set above set, J1939 command is received by the HMI, only when its length is 25 bytes, and the start code is 0x57, 0x1B;
2983 +
2984 +* Start code + Data max length (J1939)
2985 +
2986 +(% style="text-align:center" %)
2987 +[[image:12.PLC Protocol_html_74496b2a68cfcdde.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]]
2988 +
2989 +As set above set, J1939 command is received by the HMI, only when its length less than 50 bytes, and the start code is 0x57, 0x1B;
2990 +
2991 +* Data max length (J1939)
2992 +
2993 +(% style="text-align:center" %)
2994 +[[image:12.PLC Protocol_html_98cea3e7cbd8f05d.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]]
2995 +
2996 +As set above set, J1939 command is received by the HMI, only when its length less than 50 bytes.
2997 +
2998 +* Customized multiple package
2999 +
3000 +(% style="text-align:center" %)
3001 +[[image:12.PLC Protocol_html_4635bbe4d7999db0.png||data-xwiki-image-style-alignment="center" height="395" width="367" class="img-thumbnail"]]
3002 +
3003 +As set above, It is received by the HMI, when the first frame starts with 0X57 0X1B, and the sum of the data lengths of multiple frames is equal to 79 bytes.
3004 +
3005 +Click [Edit Send data] for [Send] setting
3006 +
3007 +* J1939
3008 +
3009 +(% style="text-align:center" %)
3010 +[[image:12.PLC Protocol_html_a4769e44331ca732.png||data-xwiki-image-style-alignment="center" height="280" width="463" class="img-thumbnail"]]
3011 +
3012 +[Data] is all data to be sent.
3013 +
3014 +Since the frame of the J1939 frame contains the number of the data packet, so the data sent is: the first byte (number) + 7 bytes of data. If it is less than 7 bytes, it is sent in the actual number of bytes.
3015 +
3016 +* Customized multiple package
3017 +
3018 +(% style="text-align:center" %)
3019 +[[image:12.PLC Protocol_html_78546f765d6f3deb.png||data-xwiki-image-style-alignment="center" height="280" width="463"]]
3020 +
3021 +[Data] is all data to be sent.
3022 +
3023 +As set above, fist frame length is 2 bytes, and others are sent with 6 bytes for every frame, if the last frame is less than 6 bytes, send according to the actual length.
3024 +
3025 +**Cable Wiring**
3026 +
3027 +(% style="text-align:center" %)
3028 +[[image:12.PLC Protocol_html_fccede84efcbdc22.png||data-xwiki-image-style-alignment="center" height="111" width="391" class="img-thumbnail"]]
3029 +
3030 +**✎Note:** The address interval between each frame need to be more than a word address;
image-20220829151746-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +53.1 KB
Content
image-20220829151848-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +15.0 KB
Content
image-20220829152016-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +51.2 KB
Content
image-20220829152042-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +17.0 KB
Content
image-20220829152102-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +16.3 KB
Content
image-20220829152327-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +42.5 KB
Content
image-20220829152610-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +55.5 KB
Content
image-20220829155452-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +38.1 KB
Content
image-20220829162116-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +50.4 KB
Content
image-20220830094600-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +40.4 KB
Content
image-20220830094657-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +53.4 KB
Content
image-20220830094929-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +90.4 KB
Content
image-20220830095131-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +25.7 KB
Content
image-20220830140537-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +35.2 KB
Content
image-20220830140629-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +48.4 KB
Content
image-20220830141138-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +82.9 KB
Content