Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -399,6 +399,7 @@ 399 399 400 400 (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 401 401 402 + 402 402 **Software configuration of PLC** 403 403 404 404 **1)PLC programming software** ... ... @@ -468,10 +468,69 @@ 468 468 469 469 The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 470 470 471 -= Createcommunication with **Rockwell PLC**=472 += = 472 472 473 -= =**MicroLogix Protocol** ==474 += **Allen-Bradley** = 474 474 476 +== **FreeTag Ethernet/IP (CompactLogix)** == 477 + 478 +Allen-Brandly CompactLogix 479 + 480 +**HMI Settings** 481 + 482 +(% class="table-bordered" %) 483 +|**Items**|**Settings**|**Note** 484 +|Protocol|Allen-Brandley FreeTag Ethernet/IP (CompactLogix)| 485 +|Connection|Ethernet| 486 +|Port No.|44818| 487 + 488 +**PLC Setting** 489 + 490 +Create new tags 491 + 492 +(% style="text-align:center" %) 493 +[[image:12.PLC Protocol_html_a748a27dcf7f1124.png||data-xwiki-image-style-alignment="center" height="411" width="700" class="img-thumbnail"]] 494 + 495 +Export tags to CSV file. ([Tools] » [Export] » [Tags and Logic Comments]) 496 + 497 +(% style="text-align:center" %) 498 +[[image:12.PLC Protocol_html_151379170bb8ff3e.png||data-xwiki-image-style-alignment="center" height="352" width="700" class="img-thumbnail"]] 499 + 500 +Import labels, please open [Communication] window and click [Import label]; 501 + 502 +Select csv file, all tags will be displayed as belows; 503 + 504 +(% style="text-align:center" %) 505 +[[image:12.PLC Protocol_html_af192e54dee96f38.png||data-xwiki-image-style-alignment="center" height="586" width="700" class="img-thumbnail"]] 506 + 507 +**✎Note:** 508 + 509 +Because in different region, the separation symbol is different, we suggest you check this before you want to import your tags. To open csv file as text format. 510 + 511 +(% style="text-align:center" %) 512 +[[image:12.PLC Protocol_html_33df1d63ebe53726.png||data-xwiki-image-style-alignment="center" height="206" width="700" class="img-thumbnail"]] 513 + 514 +The directory of changing system settings: [Control Panel] -> [Date, Time, Language,and Regional Options] -> [Change the format of numbers, dates, and times]->[Customize]-> [List separator]. Please select [,] and export CSV file after setting. 515 + 516 +**Communication settings in HMI** 517 + 518 +Enable HMI Ethernet in [Project Settings]; 519 + 520 +(% style="text-align:center" %) 521 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="106" width="400" class="img-thumbnail"]] 522 + 523 +Set PLC IP in [Device IP] settings; 524 + 525 +(% style="text-align:center" %) 526 +[[image:12.PLC Protocol_html_27870d373581892e.png||data-xwiki-image-style-alignment="center" height="206" width="600" class="img-thumbnail"]] 527 + 528 +**Cable Wiring** 529 + 530 +(% style="text-align:center" %) 531 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]] 532 + 533 +== **MicroLogix** == 534 + 475 475 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 476 476 477 477 **HMI Settings** ... ... @@ -507,95 +507,317 @@ 507 507 508 508 **Cable Wiring** 509 509 510 - 511 511 (% style="text-align:center" %) 512 512 [[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]] 513 513 514 -== ** FreeTagEthernet/IP(CompactLogix)** ==573 +== **AB PLC address edit** == 515 515 516 -Allen-Bra ndly CompactLogix575 +The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200. 517 517 577 +* **Bit address I:** The address ranges from 0.0 to 255.15. The value of the data before the decimal point ranges from 0 to 255 (decimal). The value from 0 to 15 after the decimal point is the sub address (decimal). 578 +* **Bit address B:** The address ranges from 000.0 to fff.15. The first f from left to right represents the block number (hexadecimal); The second and third f from left to right represent the word address (hexadecimal). The value 0 to 15 after the decimal point reprensents the sub address (decimal). 579 +* **Word address S:** The word address ranges from 0 to 255 (decimal). 580 +* **Word address TS:** The address ranges from 000.0 to ffff. The first and second f from left to right represents the block number (hexadecimal); The third and fourth f from left to right represent the word address (hexadecimal). 581 + 582 +**✎Note: **Register address TP, CS, CP, N, F and TS address edit are same. D indicates decimal, and F indicates hexadecimal. Different PLC models may support different registers. See the following table. 583 + 584 +|(% style="width:393px" %)**PLC bit address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range** 585 +|(% style="width:393px" %)I|(% style="width:350px" %)dd.dd|(% style="width:333px" %)I 0.0 ~~ 255.15 586 +|(% style="width:393px" %)O|(% style="width:350px" %)dd.dd|(% style="width:333px" %)O 0.0 ~~ 255.15 587 +|(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15 588 +|(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15 589 +|(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15 590 +|(% style="width:393px" %)**PLC word address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range** 591 +|(% style="width:393px" %)S|(% style="width:350px" %)ddd|(% style="width:333px" %)S0 ~~ 255 592 +|(% style="width:393px" %)TS|(% style="width:350px" %)ffff|(% style="width:333px" %)TS0 ~~ FFFF 593 +|(% style="width:393px" %)TP|(% style="width:350px" %)ffff|(% style="width:333px" %)TP0 ~~ FFFF 594 +|(% style="width:393px" %)CS|(% style="width:350px" %)ffff|(% style="width:333px" %)CS0 ~~ FFFF 595 +|(% style="width:393px" %)CP|(% style="width:350px" %)ffff|(% style="width:333px" %)CP0 ~~ FFFF 596 +|(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF 597 +|(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF 598 + 599 += **Barcode Scanner** = 600 + 601 +Supported: DELI 14880 barcode scanner 602 + 603 +**HMI Setting** 604 + 605 +(% class="table-bordered" %) 606 +|**Items**|**Settings**|**Note** 607 +|Protocol|Barcode Scanner| 608 +|Connection|USB| 609 + 610 +**Operating Procedures** 611 + 612 +Select [Barcode Scanner]; 613 + 614 +(% style="text-align:center" %) 615 +[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]] 616 + 617 +Set address for receiving; 618 + 619 +Set correct length; 620 + 621 +(% style="text-align:center" %) 622 +[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]] 623 + 624 +**✎Note:** 625 + 626 +* The protocol uploads the information acquired by the USB scanner to the HMI; 627 +* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 628 +* Recommended model: DELI 14880 barcode scanner; 629 + 630 += **Hitachi EHV Series (Ethernet)** = 631 + 632 +Supported series: Hitachi EHV series 633 + 518 518 **HMI Settings** 519 519 520 520 (% class="table-bordered" %) 521 521 |**Items**|**Settings**|**Note** 522 -|Protocol| Allen-BrandleyFreeTagEthernet/IP (CompactLogix)|638 +|Protocol|Hitachi EHV series| 523 523 |Connection|Ethernet| 524 -|Port No.|4 4818|640 +|Port No.|3004~~3007| 525 525 526 -** PLC Setting**642 +**Address List** 527 527 528 -Create new tags 644 +(% class="table-bordered" %) 645 +|**Type**|**Register**|**Range**|**Format**|**Note** 646 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 647 +|M|0 - 7FFF.f (Hex)|M HHHH.h| 648 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 649 +H1H2H3H4 Module main number 529 529 651 +H1: Remote number 652 + 653 +H2: Unit number 654 + 655 +H3: Slot number 656 + 657 +H4: Word number of Module 658 + 659 +H Sub number of Module 660 + 661 +For example:X21.3 662 + 663 +Slot number 2 664 + 665 +Word number of module is 1 666 + 667 +Bit number of module is 3 668 + 669 +Remote number and unit number are 0 670 +))) 671 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 672 +|R|0 – FF.f (Hex)|R HH.h| 673 +|L|0 - 73FF.f (Hex)|L HHHH.h| 674 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 675 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 676 +H1H2H3H4 Module main number 677 + 678 +H1: Remote number 679 + 680 +H2: Unit number 681 + 682 +H3: Slot number 683 + 684 +H4: Word number of module 685 + 686 +For example:WX21 687 + 688 +Word number of module is 1 689 + 690 +Slot number is 2 691 + 692 +Remote number and unit number are 0 693 +))) 694 +|WY|0 – FFFF (Hex)|WY H1H2H3H4 695 +|WR|0 – FFFF (Hex)|WR HHHH| 696 +|WL|0 - 73FF (Hex)|WL HHHH| 697 +|TC|0 - 2559|TC DDDD| 698 + 699 +**Communication settings in HMI** 700 + 701 +Enable HMI Ethernet in [Project Settings]; 702 + 530 530 (% style="text-align:center" %) 531 -[[image:12.PLC Protocol_html_ a748a27dcf7f1124.png||data-xwiki-image-style-alignment="center" height="411" width="700" class="img-thumbnail"]]704 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 532 532 533 - Export tags to CSV file. ([Tools] » [Export]»[TagsandLogicComments])706 +Set PLC IP in [Device IP] settings; 534 534 535 535 (% style="text-align:center" %) 536 -[[image:12.PLC Protocol_html_ 151379170bb8ff3e.png||data-xwiki-image-style-alignment="center" height="352" width="700" class="img-thumbnail"]]709 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 537 537 538 - Importlabels, please open [Communication] window and click [Import label];711 +**PLC Configuration** 539 539 540 - Selectcsv file,all tagswill bedisplayedas belows;713 +Connect with PLC, select[Online mode]; 541 541 542 542 (% style="text-align:center" %) 543 -[[image:12.PLC Protocol_html_ af192e54dee96f38.png||data-xwiki-image-style-alignment="center" height="586" width="700" class="img-thumbnail"]]716 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 544 544 718 +Set IP address, it is the same LAN parameters with HMI; 719 + 720 +(% style="text-align:center" %) 721 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 722 + 723 +3) Save PLC communication parameter, and restart PLC 724 + 725 +**PLC Monitor Mode** 726 + 727 +Connect with PLC and choose to “online” mode 728 + 729 +(% style="text-align:center" %) 730 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 731 + 732 +Open I/O monitor sheet1 733 + 734 +(% style="text-align:center" %) 735 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 736 + 737 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 738 + 739 +(% style="text-align:center" %) 740 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 741 + 742 +Enter the register address, click OK to view the value of the register. 743 + 744 +(% style="text-align:center" %) 745 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 746 + 747 +(% style="text-align:center" %) 748 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 749 + 545 545 **✎Note:** 546 546 547 -Because in different region, the separation symbol is different, we suggest you check this before you want to import your tags. To open csv file as text format. 752 +* Both word registers and bit registers support even continuous read/write functions; 753 +* The range of registers is based on the specific PLC type; 548 548 755 +**Cable Wiring** 756 + 549 549 (% style="text-align:center" %) 550 -[[image:12.PLC Protocol_html_ 33df1d63ebe53726.png||data-xwiki-image-style-alignment="center" height="206" width="700" class="img-thumbnail"]]758 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 551 551 552 - Thedirectory of changing system settings: [Control Panel]->[Date,Time, Language,and RegionalOptions] -> [Changethe format ofnumbers, dates,and times]->[Customize]-> [List separator]. Please select [,] and export CSV file after setting.760 += **IEC60870-5 104 Client** = 553 553 554 -** Communicationsettings in HMI**762 +**HMI Setting** 555 555 764 +(% class="table-bordered" %) 765 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 766 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 767 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 768 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 769 + 770 +**Address List** 771 + 772 +(% class="table-bordered" %) 773 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 774 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 775 +|(% style="width:461px" %)SCNA|0~~16777215.7 776 +|(% style="width:461px" %)DPTB|0~~16777215.7 777 +|(% style="width:461px" %)DCNA|0~~16777215.7 778 +|(% style="width:461px" %)METF|0~~16777215.7 779 +|(% style="width:461px" %)SENC|0~~16777215.7 780 +|(% style="width:461px" %)SENA|0~~16777215.7 781 +|(% style="width:461px" %)MENA|0~~16777215.7 782 +|(% style="width:461px" %)METD|0~~16777215.7 783 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 784 +|(% style="width:461px" %)SCNA|0~~16777215 785 +|(% style="width:461px" %)DPTB|0~~16777215 786 +|(% style="width:461px" %)DCNA|0~~16777215 787 +|(% style="width:461px" %)SENA|0~~16777215 788 +|(% style="width:461px" %)MENA|0~~16777215 789 +|(% style="width:461px" %)METD|0~~16777215 790 +|(% style="width:461px" %)INRO|0~~16777215 791 +|(% style="width:461px" %)TIMESYN|0~~16777215 792 +|(% style="width:461px" %)TIMEZ|0~~16777215 793 +|(% style="width:461px" %)NTP|0~~16777215 794 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 795 +|(% style="width:461px" %)SENC|0~~16777215 796 + 797 +**Address Configuration** 798 + 799 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 800 + 801 +(% style="text-align:center" %) 802 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 803 + 804 +(% style="text-align:center" %) 805 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 806 + 807 +Extended tag name 808 + 809 +Address range for the extended tag. 810 + 811 +**Communication Settings** 812 + 556 556 Enable HMI Ethernet in [Project Settings]; 557 557 558 558 (% style="text-align:center" %) 559 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="10 6" width="400" class="img-thumbnail"]]816 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 560 560 561 561 Set PLC IP in [Device IP] settings; 562 562 563 563 (% style="text-align:center" %) 564 -[[image:12.PLC Protocol_html_ 27870d373581892e.png||data-xwiki-image-style-alignment="center" height="206" width="600" class="img-thumbnail"]]821 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]] 565 565 566 566 **Cable Wiring** 567 567 568 568 (% style="text-align:center" %) 569 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="40 0" class="img-thumbnail"]]826 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 570 570 571 -= =**AB PLCaddressedit** ==828 += **LG XGK FEnet Ethernet** = 572 572 573 - The operational address is determinedby theconnection of Allen-BradleyPLCtoHMI. For extension modulesorotherspecial conditions,referto allen-Bradley PLC instructionmanual. The following is an example of allen-bradley MicroLogix1200.830 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 574 574 575 -* **Bit address I:** The address ranges from 0.0 to 255.15. The value of the data before the decimal point ranges from 0 to 255 (decimal). The value from 0 to 15 after the decimal point is the sub address (decimal). 576 -* **Bit address B:** The address ranges from 000.0 to fff.15. The first f from left to right represents the block number (hexadecimal); The second and third f from left to right represent the word address (hexadecimal). The value 0 to 15 after the decimal point reprensents the sub address (decimal). 577 -* **Word address S:** The word address ranges from 0 to 255 (decimal). 578 -* **Word address TS:** The address ranges from 000.0 to ffff. The first and second f from left to right represents the block number (hexadecimal); The third and fourth f from left to right represent the word address (hexadecimal). 832 +**HMI Settings** 579 579 580 -**✎Note: **Register address TP, CS, CP, N, F and TS address edit are same. D indicates decimal, and F indicates hexadecimal. Different PLC models may support different registers. See the following table. 834 +(% class="table-bordered" %) 835 +|**Items**|**Settings**|**Note** 836 +|Protocol|LG XGK FEnet(Ethernet)| 837 +|Connection|Ethernet| 838 +|Port No.|2004| 581 581 582 -|(% style="width:393px" %)**PLC bit address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range** 583 -|(% style="width:393px" %)I|(% style="width:350px" %)dd.dd|(% style="width:333px" %)I 0.0 ~~ 255.15 584 -|(% style="width:393px" %)O|(% style="width:350px" %)dd.dd|(% style="width:333px" %)O 0.0 ~~ 255.15 585 -|(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15 586 -|(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15 587 -|(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15 588 -|**PLC word address type**|**Address format**|**Address range** 589 -|S|ddd|S0 ~~ 255 590 -|TS|ffff|TS0 ~~ FFFF 591 -|TP|ffff|TP0 ~~ FFFF 592 -|CS|ffff|CS0 ~~ FFFF 593 -|CP|ffff|CP0 ~~ FFFF 594 -|N|ffff|N0 ~~ FFFF 595 -|F|ffff|F0 ~~ FFFF 840 +**Address List** 596 596 597 -= Create communication with **Mitsubishi** = 842 +(% class="table-bordered" %) 843 +|**Type**|**Register**|**Range**|**Format**|**Note** 844 +|(% rowspan="14" %)Word|P|0~~2047|P d| 845 +|M|0~~2047|M d| 846 +|K|0~~2047|K d| 847 +|F|0~~2047|F d| 848 +|T|0~~2047|T d| 849 +|C|0~~2047|C d| 850 +|Z|0~~127|Z d| 851 +|S|0~~127|S d| 852 +|L|0~~11263|L d| 853 +|N|0~~21503|N d| 854 +|D|0~~32767|D d| 855 +|R|0~~32767|R d| 856 +|ZR|0~~65535|ZR d| 857 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 598 598 859 +**✎Note:** 860 + 861 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 862 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 863 +* All bit registers are in the form of bits in word, and the range is the same as the word register; 864 + 865 +**Communication settings in HMI** 866 + 867 +Enable HMI Ethernet in [Project Settings]; 868 + 869 +(% style="text-align:center" %) 870 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 871 + 872 +Set PLC IP in [Device IP] settings; 873 + 874 +(% style="text-align:center" %) 875 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 876 + 877 +**Cable Wiring** 878 + 879 += **Mitsubishi** = 880 + 599 599 == **FX1S, 1N, 2N Series** == 600 600 601 601 Supported Series: Mitsubishi FX1S, FX1N, FX2N series ... ... @@ -2367,6 +2367,8 @@ 2367 2367 2368 2368 **✎Note:** COM3 only available in PI8000/PI9000 series. 2369 2369 2652 += = 2653 + 2370 2370 = **Printer** = 2371 2371 2372 2372 == **TSPL label printer** == ... ... @@ -2567,284 +2567,3 @@ 2567 2567 2568 2568 (% style="text-align:center" %) 2569 2569 [[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]] 2570 - 2571 -= **Barcode Scanner** = 2572 - 2573 -Supported: DELI 14880 barcode scanner 2574 - 2575 -**HMI Setting** 2576 - 2577 -|**Items**|**Settings**|**Note** 2578 -|Protocol|Barcode Scanner| 2579 -|Connection|USB| 2580 - 2581 -**Operating Procedures** 2582 - 2583 -Select [Barcode Scanner]; 2584 - 2585 -(% style="text-align:center" %) 2586 -[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]] 2587 - 2588 -Set address for receiving; 2589 - 2590 -Set correct length; 2591 - 2592 -(% style="text-align:center" %) 2593 -[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]] 2594 - 2595 -**✎Note:** 2596 - 2597 -* The protocol uploads the information acquired by the USB scanner to the HMI; 2598 -* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 2599 -* Recommended model: DELI 14880 barcode scanner; 2600 - 2601 -= **Hitachi EHV Series (Ethernet)** = 2602 - 2603 -Supported series: Hitachi EHV series 2604 - 2605 -**HMI Settings** 2606 - 2607 -(% class="table-bordered" %) 2608 -|**Items**|**Settings**|**Note** 2609 -|Protocol|Hitachi EHV series| 2610 -|Connection|Ethernet| 2611 -|Port No.|3004~~3007| 2612 - 2613 -**Address List** 2614 - 2615 -(% class="table-bordered" %) 2616 -|**Type**|**Register**|**Range**|**Format**|**Note** 2617 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 2618 -|M|0 - 7FFF.f (Hex)|M HHHH.h| 2619 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 2620 -H1H2H3H4 Module main number 2621 - 2622 -H1: Remote number 2623 - 2624 -H2: Unit number 2625 - 2626 -H3: Slot number 2627 - 2628 -H4: Word number of Module 2629 - 2630 -H Sub number of Module 2631 - 2632 -For example:X21.3 2633 - 2634 -Slot number 2 2635 - 2636 -Word number of module is 1 2637 - 2638 -Bit number of module is 3 2639 - 2640 -Remote number and unit number are 0 2641 -))) 2642 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 2643 -|R|0 – FF.f (Hex)|R HH.h| 2644 -|L|0 - 73FF.f (Hex)|L HHHH.h| 2645 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 2646 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 2647 -H1H2H3H4 Module main number 2648 - 2649 -H1: Remote number 2650 - 2651 -H2: Unit number 2652 - 2653 -H3: Slot number 2654 - 2655 -H4: Word number of module 2656 - 2657 -For example:WX21 2658 - 2659 -Word number of module is 1 2660 - 2661 -Slot number is 2 2662 - 2663 -Remote number and unit number are 0 2664 -))) 2665 -|WY|0 – FFFF (Hex)|WY H1H2H3H4 2666 -|WR|0 – FFFF (Hex)|WR HHHH| 2667 -|WL|0 - 73FF (Hex)|WL HHHH| 2668 -|TC|0 - 2559|TC DDDD| 2669 - 2670 -**Communication settings in HMI** 2671 - 2672 -Enable HMI Ethernet in [Project Settings]; 2673 - 2674 -(% style="text-align:center" %) 2675 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2676 - 2677 -Set PLC IP in [Device IP] settings; 2678 - 2679 -(% style="text-align:center" %) 2680 -[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 2681 - 2682 -**PLC Configuration** 2683 - 2684 -Connect with PLC, select[Online mode]; 2685 - 2686 -(% style="text-align:center" %) 2687 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 2688 - 2689 -Set IP address, it is the same LAN parameters with HMI; 2690 - 2691 -(% style="text-align:center" %) 2692 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 2693 - 2694 -3) Save PLC communication parameter, and restart PLC 2695 - 2696 -**PLC Monitor Mode** 2697 - 2698 -Connect with PLC and choose to “online” mode 2699 - 2700 -(% style="text-align:center" %) 2701 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 2702 - 2703 -Open I/O monitor sheet1 2704 - 2705 -(% style="text-align:center" %) 2706 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 2707 - 2708 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 2709 - 2710 -(% style="text-align:center" %) 2711 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 2712 - 2713 -Enter the register address, click OK to view the value of the register. 2714 - 2715 -(% style="text-align:center" %) 2716 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 2717 - 2718 -(% style="text-align:center" %) 2719 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 2720 - 2721 -**✎Note:** 2722 - 2723 -* Both word registers and bit registers support even continuous read/write functions; 2724 -* The range of registers is based on the specific PLC type; 2725 - 2726 -**Cable Wiring** 2727 - 2728 -(% style="text-align:center" %) 2729 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 2730 - 2731 -= **IEC60870-5 104 Client** = 2732 - 2733 -**HMI Setting** 2734 - 2735 -(% class="table-bordered" %) 2736 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 2737 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 2738 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 2739 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 2740 - 2741 -**Address List** 2742 - 2743 -(% class="table-bordered" %) 2744 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 2745 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 2746 -|(% style="width:461px" %)SCNA|0~~16777215.7 2747 -|(% style="width:461px" %)DPTB|0~~16777215.7 2748 -|(% style="width:461px" %)DCNA|0~~16777215.7 2749 -|(% style="width:461px" %)METF|0~~16777215.7 2750 -|(% style="width:461px" %)SENC|0~~16777215.7 2751 -|(% style="width:461px" %)SENA|0~~16777215.7 2752 -|(% style="width:461px" %)MENA|0~~16777215.7 2753 -|(% style="width:461px" %)METD|0~~16777215.7 2754 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 2755 -|(% style="width:461px" %)SCNA|0~~16777215 2756 -|(% style="width:461px" %)DPTB|0~~16777215 2757 -|(% style="width:461px" %)DCNA|0~~16777215 2758 -|(% style="width:461px" %)SENA|0~~16777215 2759 -|(% style="width:461px" %)MENA|0~~16777215 2760 -|(% style="width:461px" %)METD|0~~16777215 2761 -|(% style="width:461px" %)INRO|0~~16777215 2762 -|(% style="width:461px" %)TIMESYN|0~~16777215 2763 -|(% style="width:461px" %)TIMEZ|0~~16777215 2764 -|(% style="width:461px" %)NTP|0~~16777215 2765 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 2766 -|(% style="width:461px" %)SENC|0~~16777215 2767 - 2768 -**Address Configuration** 2769 - 2770 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 2771 - 2772 -(% style="text-align:center" %) 2773 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 2774 - 2775 -(% style="text-align:center" %) 2776 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 2777 - 2778 -Extended tag name 2779 - 2780 -Address range for the extended tag. 2781 - 2782 -**Communication Settings** 2783 - 2784 -Enable HMI Ethernet in [Project Settings]; 2785 - 2786 -(% style="text-align:center" %) 2787 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2788 - 2789 -Set PLC IP in [Device IP] settings; 2790 - 2791 -(% style="text-align:center" %) 2792 -[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]] 2793 - 2794 -**Cable Wiring** 2795 - 2796 -(% style="text-align:center" %) 2797 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 2798 - 2799 -= **LG XGK FEnet Ethernet** = 2800 - 2801 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 2802 - 2803 -**HMI Settings** 2804 - 2805 -(% class="table-bordered" %) 2806 -|**Items**|**Settings**|**Note** 2807 -|Protocol|LG XGK FEnet(Ethernet)| 2808 -|Connection|Ethernet| 2809 -|Port No.|2004| 2810 - 2811 -**Address List** 2812 - 2813 -(% class="table-bordered" %) 2814 -|**Type**|**Register**|**Range**|**Format**|**Note** 2815 -|(% rowspan="14" %)Word|P|0~~2047|P d| 2816 -|M|0~~2047|M d| 2817 -|K|0~~2047|K d| 2818 -|F|0~~2047|F d| 2819 -|T|0~~2047|T d| 2820 -|C|0~~2047|C d| 2821 -|Z|0~~127|Z d| 2822 -|S|0~~127|S d| 2823 -|L|0~~11263|L d| 2824 -|N|0~~21503|N d| 2825 -|D|0~~32767|D d| 2826 -|R|0~~32767|R d| 2827 -|ZR|0~~65535|ZR d| 2828 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 2829 - 2830 -**✎Note:** 2831 - 2832 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 2833 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 2834 -* All bit registers are in the form of bits in word, and the range is the same as the word register; 2835 - 2836 -**Communication settings in HMI** 2837 - 2838 -Enable HMI Ethernet in [Project Settings]; 2839 - 2840 -(% style="text-align:center" %) 2841 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2842 - 2843 -Set PLC IP in [Device IP] settings; 2844 - 2845 -(% style="text-align:center" %) 2846 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 2847 - 2848 -**Cable Wiring** 2849 - 2850 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]