399 399  
400 400  (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
401 401  
402 +
402 402  **Software configuration of PLC**
403 403  
404 404  **1)PLC programming software**
... ... @@ -470,6 +470,7 @@
470 470  
471 471  = Create communication with **Rockwell PLC** =
472 472  
474 +
473 473  == **MicroLogix Protocol** ==
474 474  
475 475  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
... ... @@ -585,17 +585,297 @@
585 585  |(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15
586 586  |(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15
587 587  |(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15
588 -|**PLC word address type**|**Address format**|**Address range**
589 -|S|ddd|S0 ~~ 255
590 -|TS|ffff|TS0 ~~ FFFF
591 -|TP|ffff|TP0 ~~ FFFF
592 -|CS|ffff|CS0 ~~ FFFF
593 -|CP|ffff|CP0 ~~ FFFF
594 -|N|ffff|N0 ~~ FFFF
595 -|F|ffff|F0 ~~ FFFF
590 +|(% style="width:393px" %)**PLC word address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range**
591 +|(% style="width:393px" %)S|(% style="width:350px" %)ddd|(% style="width:333px" %)S0 ~~ 255
592 +|(% style="width:393px" %)TS|(% style="width:350px" %)ffff|(% style="width:333px" %)TS0 ~~ FFFF
593 +|(% style="width:393px" %)TP|(% style="width:350px" %)ffff|(% style="width:333px" %)TP0 ~~ FFFF
594 +|(% style="width:393px" %)CS|(% style="width:350px" %)ffff|(% style="width:333px" %)CS0 ~~ FFFF
595 +|(% style="width:393px" %)CP|(% style="width:350px" %)ffff|(% style="width:333px" %)CP0 ~~ FFFF
596 +|(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF
597 +|(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF
596 596  
597 -= Create communication with **Mitsubishi** =
599 += **Barcode Scanner** =
598 598  
601 +Supported: DELI 14880 barcode scanner
602 +
603 +**HMI Setting**
604 +
605 +(% class="table-bordered" %)
606 +|**Items**|**Settings**|**Note**
607 +|Protocol|Barcode Scanner|
608 +|Connection|USB|
609 +
610 +**Operating Procedures**
611 +
612 +Select [Barcode Scanner];
613 +
614 +(% style="text-align:center" %)
615 +[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
616 +
617 +Set address for receiving;
618 +
619 +Set correct length;
620 +
621 +(% style="text-align:center" %)
622 +[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
623 +
624 +**✎Note:**
625 +
626 +* The protocol uploads the information acquired by the USB scanner to the HMI;
627 +* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
628 +* Recommended model: DELI 14880 barcode scanner;
629 +
630 += **Hitachi EHV Series (Ethernet)** =
631 +
632 +Supported series: Hitachi EHV series
633 +
634 +**HMI Settings**
635 +
636 +(% class="table-bordered" %)
637 +|**Items**|**Settings**|**Note**
638 +|Protocol|Hitachi EHV series|
639 +|Connection|Ethernet|
640 +|Port No.|3004~~3007|
641 +
642 +**Address List**
643 +
644 +(% class="table-bordered" %)
645 +|**Type**|**Register**|**Range**|**Format**|**Note**
646 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
647 +|M|0 - 7FFF.f (Hex)|M HHHH.h|
648 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
649 +H1H2H3H4 Module main number
650 +
651 +H1: Remote number
652 +
653 +H2: Unit number
654 +
655 +H3: Slot number
656 +
657 +H4: Word number of Module
658 +
659 +H Sub number of Module
660 +
661 +For example:X21.3
662 +
663 +Slot number 2
664 +
665 +Word number of module is 1
666 +
667 +Bit number of module is 3
668 +
669 +Remote number and unit number are 0
670 +)))
671 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
672 +|R|0 – FF.f (Hex)|R HH.h|
673 +|L|0 - 73FF.f (Hex)|L HHHH.h|
674 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
675 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
676 +H1H2H3H4 Module main number
677 +
678 +H1: Remote number
679 +
680 +H2: Unit number
681 +
682 +H3: Slot number
683 +
684 +H4: Word number of module
685 +
686 +For example:WX21
687 +
688 +Word number of module is 1
689 +
690 +Slot number is 2
691 +
692 +Remote number and unit number are 0
693 +)))
694 +|WY|0 – FFFF (Hex)|WY H1H2H3H4
695 +|WR|0 – FFFF (Hex)|WR HHHH|
696 +|WL|0 - 73FF (Hex)|WL HHHH|
697 +|TC|0 - 2559|TC DDDD|
698 +
699 +**Communication settings in HMI**
700 +
701 +Enable HMI Ethernet in [Project Settings];
702 +
703 +(% style="text-align:center" %)
704 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
705 +
706 +Set PLC IP in [Device IP] settings;
707 +
708 +(% style="text-align:center" %)
709 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
710 +
711 +**PLC Configuration**
712 +
713 +Connect with PLC, select[Online mode];
714 +
715 +(% style="text-align:center" %)
716 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
717 +
718 +Set IP address, it is the same LAN parameters with HMI;
719 +
720 +(% style="text-align:center" %)
721 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
722 +
723 +3) Save PLC communication parameter, and restart PLC
724 +
725 +**PLC Monitor Mode**
726 +
727 +Connect with PLC and choose to “online” mode
728 +
729 +(% style="text-align:center" %)
730 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
731 +
732 +Open I/O monitor sheet1
733 +
734 +(% style="text-align:center" %)
735 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
736 +
737 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
738 +
739 +(% style="text-align:center" %)
740 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
741 +
742 +Enter the register address, click OK to view the value of the register.
743 +
744 +(% style="text-align:center" %)
745 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
746 +
747 +(% style="text-align:center" %)
748 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
749 +
750 +**✎Note:**
751 +
752 +* Both word registers and bit registers support even continuous read/write functions;
753 +* The range of registers is based on the specific PLC type;
754 +
755 +**Cable Wiring**
756 +
757 +(% style="text-align:center" %)
758 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
759 +
760 += **IEC60870-5 104 Client** =
761 +
762 +**HMI Setting**
763 +
764 +(% class="table-bordered" %)
765 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
766 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
767 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
768 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
769 +
770 +**Address List**
771 +
772 +(% class="table-bordered" %)
773 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
774 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
775 +|(% style="width:461px" %)SCNA|0~~16777215.7
776 +|(% style="width:461px" %)DPTB|0~~16777215.7
777 +|(% style="width:461px" %)DCNA|0~~16777215.7
778 +|(% style="width:461px" %)METF|0~~16777215.7
779 +|(% style="width:461px" %)SENC|0~~16777215.7
780 +|(% style="width:461px" %)SENA|0~~16777215.7
781 +|(% style="width:461px" %)MENA|0~~16777215.7
782 +|(% style="width:461px" %)METD|0~~16777215.7
783 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
784 +|(% style="width:461px" %)SCNA|0~~16777215
785 +|(% style="width:461px" %)DPTB|0~~16777215
786 +|(% style="width:461px" %)DCNA|0~~16777215
787 +|(% style="width:461px" %)SENA|0~~16777215
788 +|(% style="width:461px" %)MENA|0~~16777215
789 +|(% style="width:461px" %)METD|0~~16777215
790 +|(% style="width:461px" %)INRO|0~~16777215
791 +|(% style="width:461px" %)TIMESYN|0~~16777215
792 +|(% style="width:461px" %)TIMEZ|0~~16777215
793 +|(% style="width:461px" %)NTP|0~~16777215
794 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
795 +|(% style="width:461px" %)SENC|0~~16777215
796 +
797 +**Address Configuration**
798 +
799 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
800 +
801 +(% style="text-align:center" %)
802 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
803 +
804 +(% style="text-align:center" %)
805 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
806 +
807 +Extended tag name
808 +
809 +Address range for the extended tag.
810 +
811 +**Communication Settings**
812 +
813 +Enable HMI Ethernet in [Project Settings];
814 +
815 +(% style="text-align:center" %)
816 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
817 +
818 +Set PLC IP in [Device IP] settings;
819 +
820 +(% style="text-align:center" %)
821 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
822 +
823 +**Cable Wiring**
824 +
825 +(% style="text-align:center" %)
826 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
827 +
828 += **LG XGK FEnet Ethernet** =
829 +
830 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
831 +
832 +**HMI Settings**
833 +
834 +(% class="table-bordered" %)
835 +|**Items**|**Settings**|**Note**
836 +|Protocol|LG XGK FEnet(Ethernet)|
837 +|Connection|Ethernet|
838 +|Port No.|2004|
839 +
840 +**Address List**
841 +
842 +(% class="table-bordered" %)
843 +|**Type**|**Register**|**Range**|**Format**|**Note**
844 +|(% rowspan="14" %)Word|P|0~~2047|P d|
845 +|M|0~~2047|M d|
846 +|K|0~~2047|K d|
847 +|F|0~~2047|F d|
848 +|T|0~~2047|T d|
849 +|C|0~~2047|C d|
850 +|Z|0~~127|Z d|
851 +|S|0~~127|S d|
852 +|L|0~~11263|L d|
853 +|N|0~~21503|N d|
854 +|D|0~~32767|D d|
855 +|R|0~~32767|R d|
856 +|ZR|0~~65535|ZR d|
857 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
858 +
859 +**✎Note:**
860 +
861 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
862 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
863 +* All bit registers are in the form of bits in word, and the range is the same as the word register;
864 +
865 +**Communication settings in HMI**
866 +
867 +Enable HMI Ethernet in [Project Settings];
868 +
869 +(% style="text-align:center" %)
870 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
871 +
872 +Set PLC IP in [Device IP] settings;
873 +
874 +(% style="text-align:center" %)
875 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
876 +
877 +**Cable Wiring**
878 +
879 += **Mitsubishi** =
880 +
599 599  == **FX1S, 1N, 2N Series** ==
600 600  
601 601  Supported Series: Mitsubishi FX1S, FX1N, FX2N series
... ... @@ -2367,6 +2367,8 @@
2367 2367  
2368 2368  **✎Note:** COM3 only available in PI8000/PI9000 series.
2369 2369  
2652 += =
2653 +
2370 2370  = **Printer** =
2371 2371  
2372 2372  == **TSPL label printer** ==
... ... @@ -2567,284 +2567,3 @@
2567 2567  
2568 2568  (% style="text-align:center" %)
2569 2569  [[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]]
2570 -
2571 -= **Barcode Scanner** =
2572 -
2573 -Supported: DELI 14880 barcode scanner
2574 -
2575 -**HMI Setting**
2576 -
2577 -|**Items**|**Settings**|**Note**
2578 -|Protocol|Barcode Scanner|
2579 -|Connection|USB|
2580 -
2581 -**Operating Procedures**
2582 -
2583 -Select [Barcode Scanner];
2584 -
2585 -(% style="text-align:center" %)
2586 -[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
2587 -
2588 -Set address for receiving;
2589 -
2590 -Set correct length;
2591 -
2592 -(% style="text-align:center" %)
2593 -[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
2594 -
2595 -**✎Note:**
2596 -
2597 -* The protocol uploads the information acquired by the USB scanner to the HMI;
2598 -* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
2599 -* Recommended model: DELI 14880 barcode scanner;
2600 -
2601 -= **Hitachi EHV Series (Ethernet)** =
2602 -
2603 -Supported series: Hitachi EHV series
2604 -
2605 -**HMI Settings**
2606 -
2607 -(% class="table-bordered" %)
2608 -|**Items**|**Settings**|**Note**
2609 -|Protocol|Hitachi EHV series|
2610 -|Connection|Ethernet|
2611 -|Port No.|3004~~3007|
2612 -
2613 -**Address List**
2614 -
2615 -(% class="table-bordered" %)
2616 -|**Type**|**Register**|**Range**|**Format**|**Note**
2617 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
2618 -|M|0 - 7FFF.f (Hex)|M HHHH.h|
2619 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
2620 -H1H2H3H4 Module main number
2621 -
2622 -H1: Remote number
2623 -
2624 -H2: Unit number
2625 -
2626 -H3: Slot number
2627 -
2628 -H4: Word number of Module
2629 -
2630 -H Sub number of Module
2631 -
2632 -For example:X21.3
2633 -
2634 -Slot number 2
2635 -
2636 -Word number of module is 1
2637 -
2638 -Bit number of module is 3
2639 -
2640 -Remote number and unit number are 0
2641 -)))
2642 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
2643 -|R|0 – FF.f (Hex)|R HH.h|
2644 -|L|0 - 73FF.f (Hex)|L HHHH.h|
2645 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
2646 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
2647 -H1H2H3H4 Module main number
2648 -
2649 -H1: Remote number
2650 -
2651 -H2: Unit number
2652 -
2653 -H3: Slot number
2654 -
2655 -H4: Word number of module
2656 -
2657 -For example:WX21
2658 -
2659 -Word number of module is 1
2660 -
2661 -Slot number is 2
2662 -
2663 -Remote number and unit number are 0
2664 -)))
2665 -|WY|0 – FFFF (Hex)|WY H1H2H3H4
2666 -|WR|0 – FFFF (Hex)|WR HHHH|
2667 -|WL|0 - 73FF (Hex)|WL HHHH|
2668 -|TC|0 - 2559|TC DDDD|
2669 -
2670 -**Communication settings in HMI**
2671 -
2672 -Enable HMI Ethernet in [Project Settings];
2673 -
2674 -(% style="text-align:center" %)
2675 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2676 -
2677 -Set PLC IP in [Device IP] settings;
2678 -
2679 -(% style="text-align:center" %)
2680 -[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
2681 -
2682 -**PLC Configuration**
2683 -
2684 -Connect with PLC, select[Online mode];
2685 -
2686 -(% style="text-align:center" %)
2687 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
2688 -
2689 -Set IP address, it is the same LAN parameters with HMI;
2690 -
2691 -(% style="text-align:center" %)
2692 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
2693 -
2694 -3) Save PLC communication parameter, and restart PLC
2695 -
2696 -**PLC Monitor Mode**
2697 -
2698 -Connect with PLC and choose to “online” mode
2699 -
2700 -(% style="text-align:center" %)
2701 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
2702 -
2703 -Open I/O monitor sheet1
2704 -
2705 -(% style="text-align:center" %)
2706 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
2707 -
2708 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
2709 -
2710 -(% style="text-align:center" %)
2711 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
2712 -
2713 -Enter the register address, click OK to view the value of the register.
2714 -
2715 -(% style="text-align:center" %)
2716 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
2717 -
2718 -(% style="text-align:center" %)
2719 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
2720 -
2721 -**✎Note:**
2722 -
2723 -* Both word registers and bit registers support even continuous read/write functions;
2724 -* The range of registers is based on the specific PLC type;
2725 -
2726 -**Cable Wiring**
2727 -
2728 -(% style="text-align:center" %)
2729 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2730 -
2731 -= **IEC60870-5 104 Client** =
2732 -
2733 -**HMI Setting**
2734 -
2735 -(% class="table-bordered" %)
2736 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
2737 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
2738 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
2739 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
2740 -
2741 -**Address List**
2742 -
2743 -(% class="table-bordered" %)
2744 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
2745 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
2746 -|(% style="width:461px" %)SCNA|0~~16777215.7
2747 -|(% style="width:461px" %)DPTB|0~~16777215.7
2748 -|(% style="width:461px" %)DCNA|0~~16777215.7
2749 -|(% style="width:461px" %)METF|0~~16777215.7
2750 -|(% style="width:461px" %)SENC|0~~16777215.7
2751 -|(% style="width:461px" %)SENA|0~~16777215.7
2752 -|(% style="width:461px" %)MENA|0~~16777215.7
2753 -|(% style="width:461px" %)METD|0~~16777215.7
2754 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
2755 -|(% style="width:461px" %)SCNA|0~~16777215
2756 -|(% style="width:461px" %)DPTB|0~~16777215
2757 -|(% style="width:461px" %)DCNA|0~~16777215
2758 -|(% style="width:461px" %)SENA|0~~16777215
2759 -|(% style="width:461px" %)MENA|0~~16777215
2760 -|(% style="width:461px" %)METD|0~~16777215
2761 -|(% style="width:461px" %)INRO|0~~16777215
2762 -|(% style="width:461px" %)TIMESYN|0~~16777215
2763 -|(% style="width:461px" %)TIMEZ|0~~16777215
2764 -|(% style="width:461px" %)NTP|0~~16777215
2765 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
2766 -|(% style="width:461px" %)SENC|0~~16777215
2767 -
2768 -**Address Configuration**
2769 -
2770 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
2771 -
2772 -(% style="text-align:center" %)
2773 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
2774 -
2775 -(% style="text-align:center" %)
2776 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
2777 -
2778 -Extended tag name
2779 -
2780 -Address range for the extended tag.
2781 -
2782 -**Communication Settings**
2783 -
2784 -Enable HMI Ethernet in [Project Settings];
2785 -
2786 -(% style="text-align:center" %)
2787 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2788 -
2789 -Set PLC IP in [Device IP] settings;
2790 -
2791 -(% style="text-align:center" %)
2792 -[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
2793 -
2794 -**Cable Wiring**
2795 -
2796 -(% style="text-align:center" %)
2797 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2798 -
2799 -= **LG XGK FEnet Ethernet** =
2800 -
2801 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
2802 -
2803 -**HMI Settings**
2804 -
2805 -(% class="table-bordered" %)
2806 -|**Items**|**Settings**|**Note**
2807 -|Protocol|LG XGK FEnet(Ethernet)|
2808 -|Connection|Ethernet|
2809 -|Port No.|2004|
2810 -
2811 -**Address List**
2812 -
2813 -(% class="table-bordered" %)
2814 -|**Type**|**Register**|**Range**|**Format**|**Note**
2815 -|(% rowspan="14" %)Word|P|0~~2047|P d|
2816 -|M|0~~2047|M d|
2817 -|K|0~~2047|K d|
2818 -|F|0~~2047|F d|
2819 -|T|0~~2047|T d|
2820 -|C|0~~2047|C d|
2821 -|Z|0~~127|Z d|
2822 -|S|0~~127|S d|
2823 -|L|0~~11263|L d|
2824 -|N|0~~21503|N d|
2825 -|D|0~~32767|D d|
2826 -|R|0~~32767|R d|
2827 -|ZR|0~~65535|ZR d|
2828 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
2829 -
2830 -**✎Note:**
2831 -
2832 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
2833 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
2834 -* All bit registers are in the form of bits in word, and the range is the same as the word register;
2835 -
2836 -**Communication settings in HMI**
2837 -
2838 -Enable HMI Ethernet in [Project Settings];
2839 -
2840 -(% style="text-align:center" %)
2841 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2842 -
2843 -Set PLC IP in [Device IP] settings;
2844 -
2845 -(% style="text-align:center" %)
2846 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
2847 -
2848 -**Cable Wiring**
2849 -
2850 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]