Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -399,6 +399,7 @@ 399 399 400 400 (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 401 401 402 + 402 402 **Software configuration of PLC** 403 403 404 404 **1)PLC programming software** ... ... @@ -470,6 +470,7 @@ 470 470 471 471 = Create communication with **Rockwell PLC** = 472 472 474 + 473 473 == **MicroLogix Protocol** == 474 474 475 475 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 ... ... @@ -585,160 +585,86 @@ 585 585 |(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15 586 586 |(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15 587 587 |(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15 588 -|**PLC word address type**|**Address format**|**Address range** 589 -|S|ddd|S0 ~~ 255 590 -|TS|ffff|TS0 ~~ FFFF 591 -|TP|ffff|TP0 ~~ FFFF 592 -|CS|ffff|CS0 ~~ FFFF 593 -|CP|ffff|CP0 ~~ FFFF 594 -|N|ffff|N0 ~~ FFFF 595 -|F|ffff|F0 ~~ FFFF 590 +|(% style="width:393px" %)**PLC word address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range** 591 +|(% style="width:393px" %)S|(% style="width:350px" %)ddd|(% style="width:333px" %)S0 ~~ 255 592 +|(% style="width:393px" %)TS|(% style="width:350px" %)ffff|(% style="width:333px" %)TS0 ~~ FFFF 593 +|(% style="width:393px" %)TP|(% style="width:350px" %)ffff|(% style="width:333px" %)TP0 ~~ FFFF 594 +|(% style="width:393px" %)CS|(% style="width:350px" %)ffff|(% style="width:333px" %)CS0 ~~ FFFF 595 +|(% style="width:393px" %)CP|(% style="width:350px" %)ffff|(% style="width:333px" %)CP0 ~~ FFFF 596 +|(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF 597 +|(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF 596 596 597 -= (%id="cke_bm_43878S"style="display:none"%)** **(%%)**Siemens** =599 += **Hitachi EHV Series (Ethernet)** = 598 598 599 - == **S7-200 SmartEthernet**==601 +Supported series: Hitachi EHV series 600 600 601 - Supported Series: Siemens S7-200 SMARTSeries EthernetModule.603 +**HMI Settings** 602 602 603 -Website: [[http:~~/~~/www.siemens.com/entry/cc/en/>>url:http://www.siemens.com/entry/cc/en/]] 604 - 605 -**HMI Setting** 606 - 607 607 (% class="table-bordered" %) 608 608 |**Items**|**Settings**|**Note** 609 -|Protocol| Simens S7-200 Smart Ethernet|607 +|Protocol|Hitachi EHV series| 610 610 |Connection|Ethernet| 611 -|Port No.|102| 612 -|PLC station No.|2| 609 +|Port No.|3004~~3007| 613 613 614 614 **Address List** 615 615 616 616 (% class="table-bordered" %) 617 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 618 -|(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7| 619 -|Q|Q|Q ddddd.o|0.0~~99999.7| 620 -|V|VWbit|VWbit ddddd.o|0.0~~99999.7| 621 -|V|V|V ddddd.o|0.0~~99999.7| 622 -|M|M|M ddddd.o|0.0~~99999.7| 623 -|SM|SM|ddddd.o|0.0~~99999.7| 624 -|S|S|ddddd.o|0.0~~99999.7|Read only 625 -|T|T|ddddd|0~~99999|Timer state, read only 626 -|C|C|ddddd|0~~99999|Counter state, read only 627 -|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999| 628 -|Q|QW|QW ddddd|0~~99999| 629 -|AI|AIW|AIW ddddd|0~~99999| 630 -|AQ|VB|VB ddddd|0~~99999| 631 -|V|VW|VW ddddd|0~~99998|((( 632 -VW0=VB (0~~1) 614 +|**Type**|**Register**|**Range**|**Format**|**Note** 615 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 616 +|M|0 - 7FFF.f (Hex)|M HHHH.h| 617 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 618 +H1H2H3H4 Module main number 633 633 634 - VW2=VB(2~~3)620 +H1: Remote number 635 635 636 -Address value is a multiple of 2 637 -))) 638 -|V|VD|VD ddddd|0~~99998|((( 639 -VD0=VB (0~~3) 622 +H2: Unit number 640 640 641 - VD2=VB(4~~7)624 +H3: Slot number 642 642 643 -Address value is a multiple of 4 644 -))) 645 -|M|MB|MB ddddd|0~~99999| 646 -|M|MW|MW ddddd|0~~99999|((( 647 -MW0=MB(0~~1) 626 +H4: Word number of Module 648 648 649 -M W2=MB(2~~3)628 +H Sub number of Module 650 650 651 -Address value is a multiple of 2 652 -))) 653 -|M|MD|MD ddddd|0~~99999|((( 654 -MD0=MB(0~~3) 630 +For example:X21.3 655 655 656 - MD4=MB(4~~7)632 +Slot number 2 657 657 658 -Address value is a multiple of 4 659 -))) 660 -|T|TW|TW ddddd|0~~99999|Value of timer 661 -|C|CW|CW ddddd|0~~99999|Value of counter 662 -|W|SW|SW ddddd|0~~99999| 634 +Word number of module is 1 663 663 664 - **CommunicationSettings**636 +Bit number of module is 3 665 665 666 -Enable HMI Ethernet in [Project Settings]; 638 +Remote number and unit number are 0 639 +))) 640 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 641 +|R|0 – FF.f (Hex)|R HH.h| 642 +|L|0 - 73FF.f (Hex)|L HHHH.h| 643 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 644 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 645 +H1H2H3H4 Module main number 667 667 668 -(% style="text-align:center" %) 669 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 647 +H1: Remote number 670 670 671 - SetPLC IP in[Device IP] settings;649 +H2: Unit number 672 672 673 -(% style="text-align:center" %) 674 -[[image:12.PLC Protocol_html_70b0c4c2ee21b10d.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 651 +H3: Slot number 675 675 676 -* PLC IP Address: PLC IP 677 -* PLC pot No.: 102(fixed) 678 -* Network:TCP_Client_2N(fixed) 653 +H4: Word number of module 679 679 680 -(% style="text-align:center" %) 681 -[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]] 655 +For example:WX21 682 682 683 - *Wait timeout:dependonactual networksituation(morethan1500 ms)657 +Word number of module is 1 684 684 685 - **CableWiring**659 +Slot number is 2 686 686 687 -(% style="text-align:center" %) 688 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 689 - 690 -== **S7-300 Ethernet** == 691 - 692 -Supported Series: Siemens S7-300 series PLC 693 - 694 -**HMI Setting** 695 - 696 -(% class="table-bordered" %) 697 -|**Items**|**Settings**|**Note** 698 -|Protocol|Simens S7-300 Ethernet| 699 -|Connection|Ethernet| 700 -|Port No.|102| 701 -|PLC station No.|2|Need to be same as the PLC setting 702 - 703 -**Address List** 704 - 705 -(% class="table-bordered" %) 706 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 707 -|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7| 708 -|Q|Q|Q ddddd.o|0.0~~99999.7| 709 -|M|M|M ddddd.o|0.0~~99999.7| 710 -|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|((( 711 -nn: block number; 712 - 713 -dddd: address; 661 +Remote number and unit number are 0 714 714 ))) 715 -|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999| 716 -|Q|QW|QW ddddd|0~~99999| 717 -|(% rowspan="3" %)M|MB|MB ddddd|0~~99999| 718 -|MW|MW ddddd|0~~99999|((( 719 -MW0=MB(0~~1) 663 +|WY|0 – FFFF (Hex)|WY H1H2H3H4 664 +|WR|0 – FFFF (Hex)|WR HHHH| 665 +|WL|0 - 73FF (Hex)|WL HHHH| 666 +|TC|0 - 2559|TC DDDD| 720 720 721 -M W2=MB(2~~3)668 +**Communication settings in HMI** 722 722 723 -Address value is a multiple of 2 724 -))) 725 -|MD|MD ddddd|0~~99999|((( 726 -MD0=MB(0~~3) 727 - 728 -MD4=MB(4~~7) 729 - 730 -Address value is a multiple of 4 731 -))) 732 -|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( 733 -nn: block number; 734 - 735 -dddd: address 736 -))) 737 -|DBxDBW|DBxDBW nndddd|0~~99999999 738 -|DBxDBD|DBxDBD nndddd|0~~99999999 739 - 740 -**Communication Settings** 741 - 742 742 Enable HMI Ethernet in [Project Settings]; 743 743 744 744 (% style="text-align:center" %) ... ... @@ -747,405 +747,178 @@ 747 747 Set PLC IP in [Device IP] settings; 748 748 749 749 (% style="text-align:center" %) 750 -[[image:12.PLC Protocol_html_ 910b1a0aa9e2201c.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]]678 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 751 751 752 -* PLC IP Address: PLC IP 753 -* PLC pot No.: 102(fixed) 754 -* Network:TCP_Client_2N(fixed) 680 +**PLC Configuration** 755 755 682 +Connect with PLC, select[Online mode]; 683 + 756 756 (% style="text-align:center" %) 757 -[[image:12.PLC Protocol_html_ 5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]685 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 758 758 759 - *Waittimeout:dependonactual networksituation (more than1500 ms)687 +Set IP address, it is the same LAN parameters with HMI; 760 760 761 -**Cable Wiring** 762 - 763 763 (% style="text-align:center" %) 764 -[[image:12.PLC Protocol_html_ 2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]690 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 765 765 766 - ==**S7-1200Ethernet**==692 +3) Save PLC communication parameter, and restart PLC 767 767 768 - Supported Series:Siemens S7-1200694 +**PLC Monitor Mode** 769 769 770 - **HMI Setting**696 +Connect with PLC and choose to “online” mode 771 771 772 -(% class="table-bordered" %) 773 -|**Items**|**Settings**|**Note** 774 -|Protocol|Siemens S7-1200| 775 -|Connection|Ethernet| 776 -|Port No.|102| 777 -|PLC station No.|2| 778 - 779 -**Address List** 780 - 781 -(% class="table-bordered" %) 782 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 783 -|(% rowspan="4" %)Bit|I|I|M d.o|((( 784 -d:0~-~-9999 785 - 786 -o:0-7 787 -)))| 788 -|Q|Q|Q d.o|((( 789 -d:0~-~-9999 790 - 791 -o:0-7 792 -)))| 793 -|M|M|M d.o|((( 794 -d:0~-~-9999 795 - 796 -o:0-7 797 -)))| 798 -|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|((( 799 -nn:0-9999, 800 - 801 -dddd:0-9999, 802 - 803 -o:0-7 804 -)))|((( 805 -nn:DB No. 806 - 807 -dddd:address value 808 - 809 -o: digit address 810 -))) 811 -|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999| 812 -|M|MW|MW d|d:0-99999|((( 813 -MW0=MB(0~~1) 814 - 815 -MW2=MB(2~~3) 816 - 817 -Address value is a multiple of 2 818 -))) 819 -|M|MD|MD d|d:0-99999|((( 820 -MD0=MB(0~~3) 821 - 822 -MD4=MB(4~~7) 823 - 824 -Address value is a multiple of 4 825 -))) 826 -|I|IW|IW d|d:0-99999| 827 -|Q|QW|QW d|d:0-99999| 828 -|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|((( 829 -nn:0-9999 830 - 831 -dddd:0-9999 832 -)))|((( 833 -nn:DB No. 834 - 835 -dddd:address value 836 -))) 837 -|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|((( 838 -nn:0-9999 839 - 840 -dddd:0-9999 841 -)))|((( 842 -nn:DB No. 843 - 844 -dddd:address value 845 - 846 -Address value is a multiple of 2 847 -))) 848 -|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|((( 849 -nn:0-9999 850 - 851 -dddd:0-9999 852 -)))|((( 853 -nn:DB No. 854 - 855 -dddd:address value 856 - 857 -Address value is a multiple of 4 858 -))) 859 - 860 -**Communication Settings** 861 - 862 -Enable HMI Ethernet in [Project Settings]; 863 - 864 864 (% style="text-align:center" %) 865 -[[image:12.PLC Protocol_html_ 43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]699 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 866 866 867 - SetPLCIPin[DeviceIP]settings;701 +Open I/O monitor sheet1 868 868 869 869 (% style="text-align:center" %) 870 -[[image:12.PLC Protocol_html_ f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]704 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 871 871 872 - **✎Note:**706 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 873 873 874 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens. 875 -* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 876 - 877 -**PLC Settings** 878 - 879 -Add BD 880 - 881 -* Please uncheck [Symbolic access only] option; 882 - 883 883 (% style="text-align:center" %) 884 -[[image:12.PLC Protocol_html_ 643144c591994418.png||data-xwiki-image-style-alignment="center" height="546" width="550" class="img-thumbnail"]]709 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 885 885 886 - Addresssettings,usingBD2asexample.711 +Enter the register address, click OK to view the value of the register. 887 887 888 -* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1. 889 -* 2 represent DB block number 890 -* xxxx represent address 891 - 892 -**Such as:** 893 - 894 -* DBxDBB20000 = DB2.DBB0 895 -* DBxDBW20004 = DB2.DBW4 896 - 897 897 (% style="text-align:center" %) 898 -[[image:12.PLC Protocol_html_ 87ceaea84d552e62.png||data-xwiki-image-style-alignment="center" height="245" width="537" class="img-thumbnail"]]714 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 899 899 900 -**How to connect with S7-1200 Firmware V4.0** 901 - 902 -PLC configuration 903 - 904 -* Double click [device configuration] in Siemens via software 905 -* Double click [protection] to enter protection configuration screen 906 - 907 907 (% style="text-align:center" %) 908 -[[image:12.PLC Protocol_html_ 9779940d38da8e07.png||data-xwiki-image-style-alignment="center" height="426" width="341" class="img-thumbnail"]]717 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 909 909 910 -* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)]719 +**✎Note:** 911 911 912 - (%style="text-align:center"%)913 - [[image:12.PLCProtocol_html_d2c667b02f9720b1.png||data-xwiki-image-style-alignment="center"height="296"width="554"class="img-thumbnail"]]721 +* Both word registers and bit registers support even continuous read/write functions; 722 +* The range of registers is based on the specific PLC type; 914 914 915 -DB settings 916 - 917 -* Right click [DB], select [properties] 918 -* Uncheck [optimized block access] 919 - 920 920 **Cable Wiring** 921 921 922 922 (% style="text-align:center" %) 923 923 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 924 924 925 -= =**LOGOEthernet** ==729 += **IEC60870-5 104 Client** = 926 926 927 - SupportedSeries: Siemens Logo 0BA0 series731 +**HMI Setting** 928 928 929 -**HMI Settings** 930 - 931 931 (% class="table-bordered" %) 932 -|**Items**|**Settings**|**Note** 933 -|Protocol|Siemens LOGO| 934 -|Connection|Ethernet| 935 -|Port No.|102| 936 -|PLC station No.|2| 734 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 735 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 736 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 737 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 937 937 938 938 **Address List** 939 939 940 940 (% class="table-bordered" %) 941 -|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address** 942 -|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0 943 -|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000 944 -|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000 945 -|4|VW|Word|0-1468|DB1.DBX0.0|0x000000 946 -|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0 947 -|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770 948 -|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0 949 -|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180 950 -|9|AI|Word|1-16|DB1.DBX1032.0|0x002040 951 -|10|I|Bit|1-64|DB1.DBX1024.0|0x002000 952 -|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140 953 -|12|M|Bit|1-112|DB1.DBX1104.0|0x002280 954 -|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0 955 -|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70 956 -|15|V|Bit|0-14697|DB1.DBX0.0|0x000000 742 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 743 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 744 +|(% style="width:461px" %)SCNA|0~~16777215.7 745 +|(% style="width:461px" %)DPTB|0~~16777215.7 746 +|(% style="width:461px" %)DCNA|0~~16777215.7 747 +|(% style="width:461px" %)METF|0~~16777215.7 748 +|(% style="width:461px" %)SENC|0~~16777215.7 749 +|(% style="width:461px" %)SENA|0~~16777215.7 750 +|(% style="width:461px" %)MENA|0~~16777215.7 751 +|(% style="width:461px" %)METD|0~~16777215.7 752 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 753 +|(% style="width:461px" %)SCNA|0~~16777215 754 +|(% style="width:461px" %)DPTB|0~~16777215 755 +|(% style="width:461px" %)DCNA|0~~16777215 756 +|(% style="width:461px" %)SENA|0~~16777215 757 +|(% style="width:461px" %)MENA|0~~16777215 758 +|(% style="width:461px" %)METD|0~~16777215 759 +|(% style="width:461px" %)INRO|0~~16777215 760 +|(% style="width:461px" %)TIMESYN|0~~16777215 761 +|(% style="width:461px" %)TIMEZ|0~~16777215 762 +|(% style="width:461px" %)NTP|0~~16777215 763 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 764 +|(% style="width:461px" %)SENC|0~~16777215 957 957 958 -** PLC Settingsin LOGO Software:**766 +**Address Configuration** 959 959 960 - Click[Tools]~-~-[EthernetConnections],shown as below.768 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 961 961 962 962 (% style="text-align:center" %) 963 -[[image:12.PLC Protocol_html_ 8b9d2322edf89519.png||data-xwiki-image-style-alignment="center" height="641" width="423" class="img-thumbnail"]]771 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 964 964 965 -Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 966 - 967 967 (% style="text-align:center" %) 968 -[[image:12.PLC Protocol_html_ 6c4dd041b26cd8a1.png||data-xwiki-image-style-alignment="center" height="481" width="363" class="img-thumbnail"]]774 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 969 969 970 - **TSAP set**:Thevaluesetby localTSAP is the remote TSAP set inHMI. PLC's remoteTSAP is the opposite,shown as below.776 +Extended tag name 971 971 972 -(% style="text-align:center" %) 973 -[[image:12.PLC Protocol_html_7af2611d3790a77d.png||data-xwiki-image-style-alignment="center" height="359" width="426" class="img-thumbnail"]] 778 +Address range for the extended tag. 974 974 975 -** Download Project**:Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IPaddress can be detected. Then click “ok”, andthe system will prompt that PLC will be "STOP" mode. Click “YES”to start download.780 +**Communication Settings** 976 976 977 -(% style="text-align:center" %) 978 -[[image:12.PLC Protocol_html_3243e4cd600595cc.png||data-xwiki-image-style-alignment="center" height="368" width="554" class="img-thumbnail"]] 782 +Enable HMI Ethernet in [Project Settings]; 979 979 980 - 981 981 (% style="text-align:center" %) 982 -[[image:12.PLC Protocol_html_ cb1d92e2cc91a8db.png||data-xwiki-image-style-alignment="center" height="320" width="553" class="img-thumbnail"]]785 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 983 983 984 - 985 -**HMI Communication Settings** 986 - 987 987 Set PLC IP in [Device IP] settings; 988 988 989 989 (% style="text-align:center" %) 990 -[[image: SiemensLOGODeviceIP.png]]790 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]] 991 991 992 -Enable HMI Ethernet in [Project Settings]; 993 - 994 -(% style="text-align:center" %) 995 -[[image:12.PLC Protocol_html_95917a3d92068467.png||data-xwiki-image-style-alignment="center" height="311" width="553" class="img-thumbnail"]] 996 - 997 -TSAP setting 998 - 999 -* Regarding the setting of PLC TSAP, HMI provides system special address for setting, it is recommended to run in HMI script initialization, write PLC TSAP to corresponding system special register. 1000 -* HSW10118 = local TSAP of HMI, this is remote TSAP of PLC. 1001 -* HSW10119 = Remote TSAP of HMI, this is local TSAP of PLC. 1002 - 1003 -**✎Note:** 1004 - 1005 -* The data of TSAP is hexadecimal format. For example: the remote TSAP configured in the PLC is set to 20.00, then HSW10118 should be set to 0x2000, that is, HSW10118 = 8192. 1006 - 1007 -(% style="text-align:center" %) 1008 -[[image:12.PLC Protocol_html_5c6374b21f46e01e.png||data-xwiki-image-style-alignment="center" height="139" width="498" class="img-thumbnail"]] 1009 - 1010 - 1011 -* AI word address and Ibit address are read-only and cannot be written on HMI. 1012 -* VW address should be even number.such as VW0, VW2, VW4... 1013 -* VD address it takes two VW addresses.such as VD0,VD4,VD8... 1014 -* Written value of RTC cannot exceed 255. 1015 - 1016 1016 **Cable Wiring** 1017 1017 1018 1018 (% style="text-align:center" %) 1019 1019 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 1020 1020 1021 -= =**S7-XXXEthernet** ==797 += **LG XGK FEnet Ethernet** = 1022 1022 1023 -Supported Series: Sie mensS7-400,S7-1200andS7-1500799 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 1024 1024 1025 -**HMI Setting** 801 +**HMI Settings** 1026 1026 1027 -(% class="table-bordered" style="width:823px" %) 1028 -|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note** 1029 -|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %) 1030 -|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %) 1031 -|Port No.|(% style="width:437px" %)102|(% style="width:201px" %) 1032 -|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %) 1033 -|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %) 803 +(% class="table-bordered" %) 804 +|**Items**|**Settings**|**Note** 805 +|Protocol|LG XGK FEnet(Ethernet)| 806 +|Connection|Ethernet| 807 +|Port No.|2004| 1034 1034 1035 -Slot from TIA Portal is equal to Device No. of PIStudio 1036 - 1037 -Rack from TIA Portal is equal to HMI No. of PIStudio 1038 - 1039 -(% style="text-align:center" %) 1040 -[[image:S7-XXXCommunication Settings.png]] 1041 - 1042 -(% style="text-align:center" %) 1043 -[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]] 1044 - 1045 1045 **Address List** 1046 1046 1047 1047 (% class="table-bordered" %) 1048 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 1049 -|(% rowspan="4" %)Bit|I|I|M d.o|((( 1050 -d:0~-~-9999 812 +|**Type**|**Register**|**Range**|**Format**|**Note** 813 +|(% rowspan="14" %)Word|P|0~~2047|P d| 814 +|M|0~~2047|M d| 815 +|K|0~~2047|K d| 816 +|F|0~~2047|F d| 817 +|T|0~~2047|T d| 818 +|C|0~~2047|C d| 819 +|Z|0~~127|Z d| 820 +|S|0~~127|S d| 821 +|L|0~~11263|L d| 822 +|N|0~~21503|N d| 823 +|D|0~~32767|D d| 824 +|R|0~~32767|R d| 825 +|ZR|0~~65535|ZR d| 826 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 1051 1051 1052 -o:0-7 1053 -)))| 1054 -|Q|Q|Q d.o|((( 1055 -d:0~-~-9999 828 +**✎Note:** 1056 1056 1057 -o:0-7 1058 -)))| 1059 -|M|M|M d.o|((( 1060 -d:0~-~-9999 830 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 831 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 832 +* All bit registers are in the form of bits in word, and the range is the same as the word register; 1061 1061 1062 -o:0-7 1063 -)))| 1064 -|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|((( 1065 -nn:0-9999, 834 +**Communication settings in HMI** 1066 1066 1067 -dddd:0-9999, 1068 - 1069 -o:0-7 1070 -)))|((( 1071 -nn:DB No. 1072 - 1073 -dddd:address value 1074 - 1075 -o: digit address 1076 -))) 1077 -|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999| 1078 -|M|MW|MW d|d:0-99999|((( 1079 -MW0=MB(0~~1) 1080 - 1081 -MW2=MB(2~~3) 1082 - 1083 -Address value is a multiple of 2 1084 -))) 1085 -|M|MD|MD d|d:0-99999|((( 1086 -MD0=MB(0~~3) 1087 - 1088 -MD4=MB(4~~7) 1089 - 1090 -Address value is a multiple of 4 1091 -))) 1092 -|I|IW|IW d|d:0-99999| 1093 -|Q|QW|QW d|d:0-99999| 1094 -|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|((( 1095 -nn:0-9999 1096 - 1097 -dddd:0-9999 1098 -)))|((( 1099 -nn:DB No. 1100 - 1101 -dddd:address value 1102 -))) 1103 -|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|((( 1104 -nn:0-9999 1105 - 1106 -dddd:0-9999 1107 -)))|((( 1108 -nn:DB No. 1109 - 1110 -dddd:address value 1111 - 1112 -Address value is a multiple of 2 1113 -))) 1114 -|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|((( 1115 -nn:0-9999 1116 - 1117 -dddd:0-9999 1118 -)))|((( 1119 -nn:DB No. 1120 - 1121 -dddd:address value 1122 - 1123 -Address value is a multiple of 4 1124 -))) 1125 - 1126 -**Communication Settings** 1127 - 1128 1128 Enable HMI Ethernet in [Project Settings]; 1129 1129 1130 1130 (% style="text-align:center" %) 1131 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img- rounded img-thumbnail"]]839 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 1132 1132 1133 1133 Set PLC IP in [Device IP] settings; 1134 1134 1135 1135 (% style="text-align:center" %) 1136 -[[image:12.PLC Protocol_html_ f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]844 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 1137 1137 1138 -**✎Note:** 1139 - 1140 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens. 1141 -* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 1142 - 1143 1143 **Cable Wiring** 1144 1144 1145 - {{idname="OLE_LINK8"/}}848 += **Mitsubishi** = 1146 1146 1147 -= Create communication with **Mitsubishi** = 1148 - 1149 1149 == **FX1S, 1N, 2N Series** == 1150 1150 1151 1151 Supported Series: Mitsubishi FX1S, FX1N, FX2N series ... ... @@ -3147,254 +3147,3 @@ 3147 3147 * The protocol uploads the information acquired by the USB scanner to the HMI; 3148 3148 * The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 3149 3149 * Recommended model: DELI 14880 barcode scanner; 3150 - 3151 -= **Hitachi EHV Series (Ethernet)** = 3152 - 3153 -Supported series: Hitachi EHV series 3154 - 3155 -**HMI Settings** 3156 - 3157 -(% class="table-bordered" %) 3158 -|**Items**|**Settings**|**Note** 3159 -|Protocol|Hitachi EHV series| 3160 -|Connection|Ethernet| 3161 -|Port No.|3004~~3007| 3162 - 3163 -**Address List** 3164 - 3165 -(% class="table-bordered" %) 3166 -|**Type**|**Register**|**Range**|**Format**|**Note** 3167 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 3168 -|M|0 - 7FFF.f (Hex)|M HHHH.h| 3169 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 3170 -H1H2H3H4 Module main number 3171 - 3172 -H1: Remote number 3173 - 3174 -H2: Unit number 3175 - 3176 -H3: Slot number 3177 - 3178 -H4: Word number of Module 3179 - 3180 -H Sub number of Module 3181 - 3182 -For example:X21.3 3183 - 3184 -Slot number 2 3185 - 3186 -Word number of module is 1 3187 - 3188 -Bit number of module is 3 3189 - 3190 -Remote number and unit number are 0 3191 -))) 3192 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 3193 -|R|0 – FF.f (Hex)|R HH.h| 3194 -|L|0 - 73FF.f (Hex)|L HHHH.h| 3195 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 3196 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 3197 -H1H2H3H4 Module main number 3198 - 3199 -H1: Remote number 3200 - 3201 -H2: Unit number 3202 - 3203 -H3: Slot number 3204 - 3205 -H4: Word number of module 3206 - 3207 -For example:WX21 3208 - 3209 -Word number of module is 1 3210 - 3211 -Slot number is 2 3212 - 3213 -Remote number and unit number are 0 3214 -))) 3215 -|WY|0 – FFFF (Hex)|WY H1H2H3H4 3216 -|WR|0 – FFFF (Hex)|WR HHHH| 3217 -|WL|0 - 73FF (Hex)|WL HHHH| 3218 -|TC|0 - 2559|TC DDDD| 3219 - 3220 -**Communication settings in HMI** 3221 - 3222 -Enable HMI Ethernet in [Project Settings]; 3223 - 3224 -(% style="text-align:center" %) 3225 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 3226 - 3227 -Set PLC IP in [Device IP] settings; 3228 - 3229 -(% style="text-align:center" %) 3230 -[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 3231 - 3232 -**PLC Configuration** 3233 - 3234 -Connect with PLC, select[Online mode]; 3235 - 3236 -(% style="text-align:center" %) 3237 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 3238 - 3239 -Set IP address, it is the same LAN parameters with HMI; 3240 - 3241 -(% style="text-align:center" %) 3242 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 3243 - 3244 -3) Save PLC communication parameter, and restart PLC 3245 - 3246 -**PLC Monitor Mode** 3247 - 3248 -Connect with PLC and choose to “online” mode 3249 - 3250 -(% style="text-align:center" %) 3251 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 3252 - 3253 -Open I/O monitor sheet1 3254 - 3255 -(% style="text-align:center" %) 3256 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 3257 - 3258 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 3259 - 3260 -(% style="text-align:center" %) 3261 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 3262 - 3263 -Enter the register address, click OK to view the value of the register. 3264 - 3265 -(% style="text-align:center" %) 3266 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 3267 - 3268 -(% style="text-align:center" %) 3269 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 3270 - 3271 -**✎Note:** 3272 - 3273 -* Both word registers and bit registers support even continuous read/write functions; 3274 -* The range of registers is based on the specific PLC type; 3275 - 3276 -**Cable Wiring** 3277 - 3278 -(% style="text-align:center" %) 3279 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 3280 - 3281 -= **IEC60870-5 104 Client** = 3282 - 3283 -**HMI Setting** 3284 - 3285 -(% class="table-bordered" %) 3286 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 3287 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 3288 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 3289 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 3290 - 3291 -**Address List** 3292 - 3293 -(% class="table-bordered" %) 3294 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 3295 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 3296 -|(% style="width:461px" %)SCNA|0~~16777215.7 3297 -|(% style="width:461px" %)DPTB|0~~16777215.7 3298 -|(% style="width:461px" %)DCNA|0~~16777215.7 3299 -|(% style="width:461px" %)METF|0~~16777215.7 3300 -|(% style="width:461px" %)SENC|0~~16777215.7 3301 -|(% style="width:461px" %)SENA|0~~16777215.7 3302 -|(% style="width:461px" %)MENA|0~~16777215.7 3303 -|(% style="width:461px" %)METD|0~~16777215.7 3304 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 3305 -|(% style="width:461px" %)SCNA|0~~16777215 3306 -|(% style="width:461px" %)DPTB|0~~16777215 3307 -|(% style="width:461px" %)DCNA|0~~16777215 3308 -|(% style="width:461px" %)SENA|0~~16777215 3309 -|(% style="width:461px" %)MENA|0~~16777215 3310 -|(% style="width:461px" %)METD|0~~16777215 3311 -|(% style="width:461px" %)INRO|0~~16777215 3312 -|(% style="width:461px" %)TIMESYN|0~~16777215 3313 -|(% style="width:461px" %)TIMEZ|0~~16777215 3314 -|(% style="width:461px" %)NTP|0~~16777215 3315 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 3316 -|(% style="width:461px" %)SENC|0~~16777215 3317 - 3318 -**Address Configuration** 3319 - 3320 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 3321 - 3322 -(% style="text-align:center" %) 3323 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 3324 - 3325 -(% style="text-align:center" %) 3326 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 3327 - 3328 -Extended tag name 3329 - 3330 -Address range for the extended tag. 3331 - 3332 -**Communication Settings** 3333 - 3334 -Enable HMI Ethernet in [Project Settings]; 3335 - 3336 -(% style="text-align:center" %) 3337 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 3338 - 3339 -Set PLC IP in [Device IP] settings; 3340 - 3341 -(% style="text-align:center" %) 3342 -[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]] 3343 - 3344 -**Cable Wiring** 3345 - 3346 -(% style="text-align:center" %) 3347 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 3348 - 3349 -= **LG XGK FEnet Ethernet** = 3350 - 3351 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 3352 - 3353 -**HMI Settings** 3354 - 3355 -(% class="table-bordered" %) 3356 -|**Items**|**Settings**|**Note** 3357 -|Protocol|LG XGK FEnet(Ethernet)| 3358 -|Connection|Ethernet| 3359 -|Port No.|2004| 3360 - 3361 -**Address List** 3362 - 3363 -(% class="table-bordered" %) 3364 -|**Type**|**Register**|**Range**|**Format**|**Note** 3365 -|(% rowspan="14" %)Word|P|0~~2047|P d| 3366 -|M|0~~2047|M d| 3367 -|K|0~~2047|K d| 3368 -|F|0~~2047|F d| 3369 -|T|0~~2047|T d| 3370 -|C|0~~2047|C d| 3371 -|Z|0~~127|Z d| 3372 -|S|0~~127|S d| 3373 -|L|0~~11263|L d| 3374 -|N|0~~21503|N d| 3375 -|D|0~~32767|D d| 3376 -|R|0~~32767|R d| 3377 -|ZR|0~~65535|ZR d| 3378 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 3379 - 3380 -**✎Note:** 3381 - 3382 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 3383 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 3384 -* All bit registers are in the form of bits in word, and the range is the same as the word register; 3385 - 3386 -**Communication settings in HMI** 3387 - 3388 -Enable HMI Ethernet in [Project Settings]; 3389 - 3390 -(% style="text-align:center" %) 3391 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 3392 - 3393 -Set PLC IP in [Device IP] settings; 3394 - 3395 -(% style="text-align:center" %) 3396 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 3397 - 3398 -**Cable Wiring** 3399 - 3400 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]