Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -594,9 +594,9 @@ 594 594 |N|ffff|N0 ~~ FFFF 595 595 |F|ffff|F0 ~~ FFFF 596 596 597 -= Create communication with(% id="cke_bm_43878S" style="display:none" %)** **(%%)**Siemens** =597 += (% id="cke_bm_43878S" style="display:none" %)** **(%%)**Siemens** = 598 598 599 -== **S7-200 Smart Protocol** ==599 +== **S7-200 Smart Ethernet** == 600 600 601 601 Supported Series: Siemens S7-200 SMART Series Ethernet Module. 602 602 ... ... @@ -922,6 +922,102 @@ 922 922 (% style="text-align:center" %) 923 923 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 924 924 925 +== **LOGO Ethernet** == 926 + 927 +Supported Series: Siemens Logo 0BA0 series 928 + 929 +**HMI Settings** 930 + 931 +(% class="table-bordered" %) 932 +|**Items**|**Settings**|**Note** 933 +|Protocol|Siemens LOGO| 934 +|Connection|Ethernet| 935 +|Port No.|102| 936 +|PLC station No.|2| 937 + 938 +**Address List** 939 + 940 +(% class="table-bordered" %) 941 +|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address** 942 +|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0 943 +|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000 944 +|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000 945 +|4|VW|Word|0-1468|DB1.DBX0.0|0x000000 946 +|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0 947 +|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770 948 +|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0 949 +|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180 950 +|9|AI|Word|1-16|DB1.DBX1032.0|0x002040 951 +|10|I|Bit|1-64|DB1.DBX1024.0|0x002000 952 +|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140 953 +|12|M|Bit|1-112|DB1.DBX1104.0|0x002280 954 +|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0 955 +|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70 956 +|15|V|Bit|0-14697|DB1.DBX0.0|0x000000 957 + 958 +**PLC Settings in LOGO Software:** 959 + 960 +Click [Tools]~-~-[Ethernet Connections],shown as below. 961 + 962 +(% style="text-align:center" %) 963 +[[image:12.PLC Protocol_html_8b9d2322edf89519.png||data-xwiki-image-style-alignment="center" height="641" width="423" class="img-thumbnail"]] 964 + 965 +Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 966 + 967 +(% style="text-align:center" %) 968 +[[image:12.PLC Protocol_html_6c4dd041b26cd8a1.png||data-xwiki-image-style-alignment="center" height="481" width="363" class="img-thumbnail"]] 969 + 970 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 971 + 972 +(% style="text-align:center" %) 973 +[[image:12.PLC Protocol_html_7af2611d3790a77d.png||data-xwiki-image-style-alignment="center" height="359" width="426" class="img-thumbnail"]] 974 + 975 +**Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download. 976 + 977 +(% style="text-align:center" %) 978 +[[image:12.PLC Protocol_html_3243e4cd600595cc.png||data-xwiki-image-style-alignment="center" height="368" width="554" class="img-thumbnail"]] 979 + 980 + 981 +(% style="text-align:center" %) 982 +[[image:12.PLC Protocol_html_cb1d92e2cc91a8db.png||data-xwiki-image-style-alignment="center" height="320" width="553" class="img-thumbnail"]] 983 + 984 + 985 +**HMI Communication Settings** 986 + 987 +Set PLC IP in [Device IP] settings; 988 + 989 +(% style="text-align:center" %) 990 +[[image:SiemensLOGODeviceIP.png]] 991 + 992 +Enable HMI Ethernet in [Project Settings]; 993 + 994 +(% style="text-align:center" %) 995 +[[image:12.PLC Protocol_html_95917a3d92068467.png||data-xwiki-image-style-alignment="center" height="311" width="553" class="img-thumbnail"]] 996 + 997 +TSAP setting 998 + 999 +* Regarding the setting of PLC TSAP, HMI provides system special address for setting, it is recommended to run in HMI script initialization, write PLC TSAP to corresponding system special register. 1000 +* HSW10118 = local TSAP of HMI, this is remote TSAP of PLC. 1001 +* HSW10119 = Remote TSAP of HMI, this is local TSAP of PLC. 1002 + 1003 +**✎Note:** 1004 + 1005 +* The data of TSAP is hexadecimal format. For example: the remote TSAP configured in the PLC is set to 20.00, then HSW10118 should be set to 0x2000, that is, HSW10118 = 8192. 1006 + 1007 +(% style="text-align:center" %) 1008 +[[image:12.PLC Protocol_html_5c6374b21f46e01e.png||data-xwiki-image-style-alignment="center" height="139" width="498" class="img-thumbnail"]] 1009 + 1010 + 1011 +* AI word address and Ibit address are read-only and cannot be written on HMI. 1012 +* VW address should be even number.such as VW0, VW2, VW4... 1013 +* VD address it takes two VW addresses.such as VD0,VD4,VD8... 1014 +* Written value of RTC cannot exceed 255. 1015 + 1016 +**Cable Wiring** 1017 + 1018 +(% style="text-align:center" %) 1019 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 1020 + 925 925 == **S7-XXX Ethernet** == 926 926 927 927 Supported Series: Siemens S7-400, S7-1200 and S7-1500 ... ... @@ -1048,101 +1048,6 @@ 1048 1048 1049 1049 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1050 1050 1051 -== (% id="cke_bm_25456S" style="display:none" %)** **(%%)**LOGO Ethernet** == 1052 - 1053 -Supported Series: Siemens Logo 0BA0 series 1054 - 1055 -**HMI Settings** 1056 - 1057 -(% class="table-bordered" %) 1058 -|**Items**|**Settings**|**Note** 1059 -|Protocol|Siemens LOGO| 1060 -|Connection|Ethernet| 1061 -|Port No.|102| 1062 -|PLC station No.|2| 1063 - 1064 -**Address List** 1065 - 1066 -(% class="table-bordered" %) 1067 -|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address** 1068 -|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0 1069 -|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000 1070 -|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000 1071 -|4|VW|Word|0-1468|DB1.DBX0.0|0x000000 1072 -|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0 1073 -|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770 1074 -|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0 1075 -|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180 1076 -|9|AI|Word|1-16|DB1.DBX1032.0|0x002040 1077 -|10|I|Bit|1-64|DB1.DBX1024.0|0x002000 1078 -|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140 1079 -|12|M|Bit|1-112|DB1.DBX1104.0|0x002280 1080 -|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0 1081 -|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70 1082 -|15|V|Bit|0-14697|DB1.DBX0.0|0x000000 1083 - 1084 -**PLC Settings in LOGO Software:** 1085 - 1086 -Click [Tools]~-~-[Ethernet Connections],shown as below. 1087 - 1088 -(% style="text-align:center" %) 1089 -[[image:12.PLC Protocol_html_8b9d2322edf89519.png||data-xwiki-image-style-alignment="center" height="641" width="423" class="img-thumbnail"]] 1090 - 1091 -Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 1092 - 1093 -(% style="text-align:center" %) 1094 -[[image:12.PLC Protocol_html_6c4dd041b26cd8a1.png||data-xwiki-image-style-alignment="center" height="481" width="363" class="img-thumbnail"]] 1095 - 1096 -**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 1097 - 1098 -(% style="text-align:center" %) 1099 -[[image:12.PLC Protocol_html_7af2611d3790a77d.png||data-xwiki-image-style-alignment="center" height="359" width="426" class="img-thumbnail"]] 1100 - 1101 -**Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download. 1102 - 1103 -(% style="text-align:center" %) 1104 -[[image:12.PLC Protocol_html_3243e4cd600595cc.png||data-xwiki-image-style-alignment="center" height="368" width="554" class="img-thumbnail"]] 1105 - 1106 - 1107 -(% style="text-align:center" %) 1108 -[[image:12.PLC Protocol_html_cb1d92e2cc91a8db.png||data-xwiki-image-style-alignment="center" height="320" width="553" class="img-thumbnail"]] 1109 - 1110 - 1111 -**HMI Communication Settings** 1112 - 1113 -Set PLC IP in [Device IP] settings; 1114 - 1115 -(% style="text-align:center" %) 1116 -[[image:SiemensLOGODeviceIP.png]] 1117 - 1118 -Enable HMI Ethernet in [Project Settings]; 1119 - 1120 -(% style="text-align:center" %) 1121 -[[image:12.PLC Protocol_html_95917a3d92068467.png||data-xwiki-image-style-alignment="center" height="311" width="553" class="img-thumbnail"]] 1122 - 1123 -TSAP setting 1124 - 1125 -* Regarding the setting of PLC TSAP, HMI provides system special address for setting, it is recommended to run in HMI script initialization, write PLC TSAP to corresponding system special register. 1126 -* HSW10118 = local TSAP of HMI, this is remote TSAP of PLC. 1127 -* HSW10119 = Remote TSAP of HMI, this is local TSAP of PLC. 1128 - 1129 -**✎Note:** 1130 - 1131 -* The data of TSAP is hexadecimal format. For example: the remote TSAP configured in the PLC is set to 20.00, then HSW10118 should be set to 0x2000, that is, HSW10118 = 8192. 1132 - 1133 -(% style="text-align:center" %) 1134 -[[image:12.PLC Protocol_html_5c6374b21f46e01e.png||data-xwiki-image-style-alignment="center" height="139" width="498" class="img-thumbnail"]] 1135 - 1136 - 1137 -* AI word address and Ibit address are read-only and cannot be written on HMI. 1138 -* VW address should be even number.such as VW0, VW2, VW4... 1139 -* VD address it takes two VW addresses.such as VD0,VD4,VD8... 1140 -* Written value of RTC cannot exceed 255. 1141 - 1142 -**Cable Wiring** 1143 - 1144 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1145 - 1146 1146 = Create communication with **Mitsubishi** = 1147 1147 1148 1148 == **FX1S, 1N, 2N Series** ==