... ... @@ -585,568 +585,21 @@
585 585  |(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15
586 586  |(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15
587 587  |(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15
588 -|**PLC word address type**|**Address format**|**Address range**
589 -|S|ddd|S0 ~~ 255
590 -|TS|ffff|TS0 ~~ FFFF
591 -|TP|ffff|TP0 ~~ FFFF
592 -|CS|ffff|CS0 ~~ FFFF
593 -|CP|ffff|CP0 ~~ FFFF
594 -|N|ffff|N0 ~~ FFFF
595 -|F|ffff|F0 ~~ FFFF
588 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
589 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
590 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
591 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
592 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
593 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
594 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
595 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
596 596  
597 -= Create communication with (% id="cke_bm_43878S" style="display:none" %)** **(%%)**Siemens** =
597 += =
598 598  
599 -== **S7-200 Smart Ethernet Protocol** ==
599 += **Mitsubishi** =
600 600  
601 -Supported Series: Siemens S7-200 SMART Series Ethernet Module.
601 +== **FX1S, 1N, 2N Series** ==
602 602  
603 -Website: [[http:~~/~~/www.siemens.com/entry/cc/en/>>url:http://www.siemens.com/entry/cc/en/]]
604 -
605 -**HMI Setting**
606 -
607 -(% class="table-bordered" %)
608 -|**Items**|**Settings**|**Note**
609 -|Protocol|Simens S7-200 Smart Ethernet|
610 -|Connection|Ethernet|
611 -|Port No.|102|
612 -|PLC station No.|2|
613 -
614 -**Address List**
615 -
616 -(% class="table-bordered" %)
617 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
618 -|(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
619 -|Q|Q|Q ddddd.o|0.0~~99999.7|
620 -|V|VWbit|VWbit ddddd.o|0.0~~99999.7|
621 -|V|V|V ddddd.o|0.0~~99999.7|
622 -|M|M|M ddddd.o|0.0~~99999.7|
623 -|SM|SM|ddddd.o|0.0~~99999.7|
624 -|S|S|ddddd.o|0.0~~99999.7|Read only
625 -|T|T|ddddd|0~~99999|Timer state, read only
626 -|C|C|ddddd|0~~99999|Counter state, read only
627 -|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999|
628 -|Q|QW|QW ddddd|0~~99999|
629 -|AI|AIW|AIW ddddd|0~~99999|
630 -|AQ|VB|VB ddddd|0~~99999|
631 -|V|VW|VW ddddd|0~~99998|(((
632 -VW0=VB (0~~1)
633 -
634 -VW2=VB (2~~3)
635 -
636 -Address value is a multiple of 2
637 -)))
638 -|V|VD|VD ddddd|0~~99998|(((
639 -VD0=VB (0~~3)
640 -
641 -VD2=VB (4~~7)
642 -
643 -Address value is a multiple of 4
644 -)))
645 -|M|MB|MB ddddd|0~~99999|
646 -|M|MW|MW ddddd|0~~99999|(((
647 -MW0=MB(0~~1)
648 -
649 -MW2=MB(2~~3)
650 -
651 -Address value is a multiple of 2
652 -)))
653 -|M|MD|MD ddddd|0~~99999|(((
654 -MD0=MB(0~~3)
655 -
656 -MD4=MB(4~~7)
657 -
658 -Address value is a multiple of 4
659 -)))
660 -|T|TW|TW ddddd|0~~99999|Value of timer
661 -|C|CW|CW ddddd|0~~99999|Value of counter
662 -|W|SW|SW ddddd|0~~99999|
663 -
664 -**Communication Settings**
665 -
666 -Enable HMI Ethernet in [Project Settings];
667 -
668 -(% style="text-align:center" %)
669 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
670 -
671 -Set PLC IP in [Device IP] settings;
672 -
673 -(% style="text-align:center" %)
674 -[[image:12.PLC Protocol_html_70b0c4c2ee21b10d.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
675 -
676 -* PLC IP Address: PLC IP
677 -* PLC pot No.: 102(fixed)
678 -* Network:TCP_Client_2N(fixed)
679 -
680 -(% style="text-align:center" %)
681 -[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
682 -
683 -* Wait timeout: depend on actual network situation (more than 1500 ms)
684 -
685 -**Cable Wiring**
686 -
687 -(% style="text-align:center" %)
688 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
689 -
690 -== **S7-300 Ethernet Protocol** ==
691 -
692 -Supported Series: Siemens S7-300 series PLC
693 -
694 -**HMI Setting**
695 -
696 -(% class="table-bordered" %)
697 -|**Items**|**Settings**|**Note**
698 -|Protocol|Simens S7-300 Ethernet|
699 -|Connection|Ethernet|
700 -|Port No.|102|
701 -|PLC station No.|2|Need to be same as the PLC setting
702 -
703 -**Address List**
704 -
705 -(% class="table-bordered" %)
706 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
707 -|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
708 -|Q|Q|Q ddddd.o|0.0~~99999.7|
709 -|M|M|M ddddd.o|0.0~~99999.7|
710 -|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
711 -nn: block number;
712 -
713 -dddd: address;
714 -)))
715 -|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
716 -|Q|QW|QW ddddd|0~~99999|
717 -|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
718 -|MW|MW ddddd|0~~99999|(((
719 -MW0=MB(0~~1)
720 -
721 -MW2=MB(2~~3)
722 -
723 -Address value is a multiple of 2
724 -)))
725 -|MD|MD ddddd|0~~99999|(((
726 -MD0=MB(0~~3)
727 -
728 -MD4=MB(4~~7)
729 -
730 -Address value is a multiple of 4
731 -)))
732 -|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
733 -nn: block number;
734 -
735 -dddd: address
736 -)))
737 -|DBxDBW|DBxDBW nndddd|0~~99999999
738 -|DBxDBD|DBxDBD nndddd|0~~99999999
739 -
740 -**Communication Settings**
741 -
742 -Enable HMI Ethernet in [Project Settings];
743 -
744 -(% style="text-align:center" %)
745 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
746 -
747 -Set PLC IP in [Device IP] settings;
748 -
749 -(% style="text-align:center" %)
750 -[[image:12.PLC Protocol_html_910b1a0aa9e2201c.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]]
751 -
752 -* PLC IP Address: PLC IP
753 -* PLC pot No.: 102(fixed)
754 -* Network:TCP_Client_2N(fixed)
755 -
756 -(% style="text-align:center" %)
757 -[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
758 -
759 -* Wait timeout: depend on actual network situation (more than 1500 ms)
760 -
761 -**Cable Wiring**
762 -
763 -(% style="text-align:center" %)
764 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
765 -
766 -== **S7-1200 Ethernet Protocol** ==
767 -
768 -Supported Series: Siemens S7-1200
769 -
770 -**HMI Setting**
771 -
772 -(% class="table-bordered" %)
773 -|**Items**|**Settings**|**Note**
774 -|Protocol|Siemens S7-1200|
775 -|Connection|Ethernet|
776 -|Port No.|102|
777 -|PLC station No.|2|
778 -
779 -**Address List**
780 -
781 -(% class="table-bordered" %)
782 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
783 -|(% rowspan="4" %)Bit|I|I|M d.o|(((
784 -d:0~-~-9999
785 -
786 -o:0-7
787 -)))|
788 -|Q|Q|Q d.o|(((
789 -d:0~-~-9999
790 -
791 -o:0-7
792 -)))|
793 -|M|M|M d.o|(((
794 -d:0~-~-9999
795 -
796 -o:0-7
797 -)))|
798 -|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
799 -nn:0-9999,
800 -
801 -dddd:0-9999,
802 -
803 -o:0-7
804 -)))|(((
805 -nn:DB No.
806 -
807 -dddd:address value
808 -
809 -o: digit address
810 -)))
811 -|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
812 -|M|MW|MW d|d:0-99999|(((
813 -MW0=MB(0~~1)
814 -
815 -MW2=MB(2~~3)
816 -
817 -Address value is a multiple of 2
818 -)))
819 -|M|MD|MD d|d:0-99999|(((
820 -MD0=MB(0~~3)
821 -
822 -MD4=MB(4~~7)
823 -
824 -Address value is a multiple of 4
825 -)))
826 -|I|IW|IW d|d:0-99999|
827 -|Q|QW|QW d|d:0-99999|
828 -|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
829 -nn:0-9999
830 -
831 -dddd:0-9999
832 -)))|(((
833 -nn:DB No.
834 -
835 -dddd:address value
836 -)))
837 -|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
838 -nn:0-9999
839 -
840 -dddd:0-9999
841 -)))|(((
842 -nn:DB No.
843 -
844 -dddd:address value
845 -
846 -Address value is a multiple of 2
847 -)))
848 -|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
849 -nn:0-9999
850 -
851 -dddd:0-9999
852 -)))|(((
853 -nn:DB No.
854 -
855 -dddd:address value
856 -
857 -Address value is a multiple of 4
858 -)))
859 -
860 -**Communication Settings**
861 -
862 -Enable HMI Ethernet in [Project Settings];
863 -
864 -(% style="text-align:center" %)
865 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
866 -
867 -Set PLC IP in [Device IP] settings;
868 -
869 -(% style="text-align:center" %)
870 -[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
871 -
872 -**✎Note:**
873 -
874 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
875 -* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
876 -
877 -**PLC Settings**
878 -
879 -Add BD
880 -
881 -* Please uncheck [Symbolic access only] option;
882 -
883 -(% style="text-align:center" %)
884 -[[image:12.PLC Protocol_html_643144c591994418.png||data-xwiki-image-style-alignment="center" height="546" width="550" class="img-thumbnail"]]
885 -
886 -Address settings, using BD2 as example.
887 -
888 -* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1.
889 -* 2 represent DB block number
890 -* xxxx represent address
891 -
892 -**Such as:**
893 -
894 -* DBxDBB20000 = DB2.DBB0
895 -* DBxDBW20004 = DB2.DBW4
896 -
897 -(% style="text-align:center" %)
898 -[[image:12.PLC Protocol_html_87ceaea84d552e62.png||data-xwiki-image-style-alignment="center" height="245" width="537" class="img-thumbnail"]]
899 -
900 -**How to connect with S7-1200 Firmware V4.0**
901 -
902 -PLC configuration
903 -
904 -* Double click [device configuration] in Siemens via software
905 -* Double click [protection] to enter protection configuration screen
906 -
907 -(% style="text-align:center" %)
908 -[[image:12.PLC Protocol_html_9779940d38da8e07.png||data-xwiki-image-style-alignment="center" height="426" width="341" class="img-thumbnail"]]
909 -
910 -* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)]
911 -
912 -(% style="text-align:center" %)
913 -[[image:12.PLC Protocol_html_d2c667b02f9720b1.png||data-xwiki-image-style-alignment="center" height="296" width="554" class="img-thumbnail"]]
914 -
915 -DB settings
916 -
917 -* Right click [DB], select [properties]
918 -* Uncheck [optimized block access]
919 -
920 -**Cable Wiring**
921 -
922 -(% style="text-align:center" %)
923 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
924 -
925 -== **S7-XXX Ethernet Protocol** ==
926 -
927 -Supported Series: Siemens S7-400, S7-1200 and S7-1500
928 -
929 -**HMI Setting**
930 -
931 -(% class="table-bordered" style="width:823px" %)
932 -|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note**
933 -|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %)
934 -|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %)
935 -|Port No.|(% style="width:437px" %)102|(% style="width:201px" %)
936 -|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %)
937 -|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %)
938 -
939 -Slot from TIA Portal is equal to Device No. of PIStudio
940 -
941 -Rack from TIA Portal is equal to HMI No. of PIStudio
942 -
943 -(% style="text-align:center" %)
944 -[[image:S7-XXXCommunication Settings.png]]
945 -
946 -(% style="text-align:center" %)
947 -[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]]
948 -
949 -**Address List**
950 -
951 -(% class="table-bordered" %)
952 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
953 -|(% rowspan="4" %)Bit|I|I|M d.o|(((
954 -d:0~-~-9999
955 -
956 -o:0-7
957 -)))|
958 -|Q|Q|Q d.o|(((
959 -d:0~-~-9999
960 -
961 -o:0-7
962 -)))|
963 -|M|M|M d.o|(((
964 -d:0~-~-9999
965 -
966 -o:0-7
967 -)))|
968 -|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
969 -nn:0-9999,
970 -
971 -dddd:0-9999,
972 -
973 -o:0-7
974 -)))|(((
975 -nn:DB No.
976 -
977 -dddd:address value
978 -
979 -o: digit address
980 -)))
981 -|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
982 -|M|MW|MW d|d:0-99999|(((
983 -MW0=MB(0~~1)
984 -
985 -MW2=MB(2~~3)
986 -
987 -Address value is a multiple of 2
988 -)))
989 -|M|MD|MD d|d:0-99999|(((
990 -MD0=MB(0~~3)
991 -
992 -MD4=MB(4~~7)
993 -
994 -Address value is a multiple of 4
995 -)))
996 -|I|IW|IW d|d:0-99999|
997 -|Q|QW|QW d|d:0-99999|
998 -|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
999 -nn:0-9999
1000 -
1001 -dddd:0-9999
1002 -)))|(((
1003 -nn:DB No.
1004 -
1005 -dddd:address value
1006 -)))
1007 -|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
1008 -nn:0-9999
1009 -
1010 -dddd:0-9999
1011 -)))|(((
1012 -nn:DB No.
1013 -
1014 -dddd:address value
1015 -
1016 -Address value is a multiple of 2
1017 -)))
1018 -|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
1019 -nn:0-9999
1020 -
1021 -dddd:0-9999
1022 -)))|(((
1023 -nn:DB No.
1024 -
1025 -dddd:address value
1026 -
1027 -Address value is a multiple of 4
1028 -)))
1029 -
1030 -**Communication Settings**
1031 -
1032 -Enable HMI Ethernet in [Project Settings];
1033 -
1034 -(% style="text-align:center" %)
1035 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]]
1036 -
1037 -Set PLC IP in [Device IP] settings;
1038 -
1039 -(% style="text-align:center" %)
1040 -[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
1041 -
1042 -**✎Note:**
1043 -
1044 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
1045 -* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
1046 -
1047 -**Cable Wiring**
1048 -
1049 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1050 -
1051 -== (% id="cke_bm_25456S" style="display:none" %)** **(%%)**LOGO Ethernet Protocol** ==
1052 -
1053 -Supported Series: Siemens Logo 0BA0 series
1054 -
1055 -**HMI Settings**
1056 -
1057 -(% class="table-bordered" %)
1058 -|**Items**|**Settings**|**Note**
1059 -|Protocol|Siemens LOGO|
1060 -|Connection|Ethernet|
1061 -|Port No.|102|
1062 -|PLC station No.|2|
1063 -
1064 -**Address List**
1065 -
1066 -(% class="table-bordered" %)
1067 -|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
1068 -|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
1069 -|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
1070 -|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
1071 -|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
1072 -|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
1073 -|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
1074 -|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
1075 -|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
1076 -|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
1077 -|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
1078 -|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
1079 -|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
1080 -|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
1081 -|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
1082 -|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
1083 -
1084 -**PLC Settings in LOGO Software:**
1085 -
1086 -Click [Tools]~-~-[Ethernet Connections],shown as below.
1087 -
1088 -(% style="text-align:center" %)
1089 -[[image:12.PLC Protocol_html_8b9d2322edf89519.png||data-xwiki-image-style-alignment="center" height="641" width="423" class="img-thumbnail"]]
1090 -
1091 -Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
1092 -
1093 -(% style="text-align:center" %)
1094 -[[image:12.PLC Protocol_html_6c4dd041b26cd8a1.png||data-xwiki-image-style-alignment="center" height="481" width="363" class="img-thumbnail"]]
1095 -
1096 -**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
1097 -
1098 -(% style="text-align:center" %)
1099 -[[image:12.PLC Protocol_html_7af2611d3790a77d.png||data-xwiki-image-style-alignment="center" height="359" width="426" class="img-thumbnail"]]
1100 -
1101 -**Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
1102 -
1103 -(% style="text-align:center" %)
1104 -[[image:12.PLC Protocol_html_3243e4cd600595cc.png||data-xwiki-image-style-alignment="center" height="368" width="554" class="img-thumbnail"]]
1105 -
1106 -
1107 -(% style="text-align:center" %)
1108 -[[image:12.PLC Protocol_html_cb1d92e2cc91a8db.png||data-xwiki-image-style-alignment="center" height="320" width="553" class="img-thumbnail"]]
1109 -
1110 -
1111 -**HMI Communication Settings**
1112 -
1113 -Set PLC IP in [Device IP] settings;
1114 -
1115 -(% style="text-align:center" %)
1116 -[[image:SiemensLOGODeviceIP.png]]
1117 -
1118 -Enable HMI Ethernet in [Project Settings];
1119 -
1120 -(% style="text-align:center" %)
1121 -[[image:12.PLC Protocol_html_95917a3d92068467.png||data-xwiki-image-style-alignment="center" height="311" width="553" class="img-thumbnail"]]
1122 -
1123 -TSAP setting
1124 -
1125 -* Regarding the setting of PLC TSAP, HMI provides system special address for setting, it is recommended to run in HMI script initialization, write PLC TSAP to corresponding system special register.
1126 -* HSW10118 = local TSAP of HMI, this is remote TSAP of PLC.
1127 -* HSW10119 = Remote TSAP of HMI, this is local TSAP of PLC.
1128 -
1129 -**✎Note:**
1130 -
1131 -* The data of TSAP is hexadecimal format. For example: the remote TSAP configured in the PLC is set to 20.00, then HSW10118 should be set to 0x2000, that is, HSW10118 = 8192.
1132 -
1133 -(% style="text-align:center" %)
1134 -[[image:12.PLC Protocol_html_5c6374b21f46e01e.png||data-xwiki-image-style-alignment="center" height="139" width="498" class="img-thumbnail"]]
1135 -
1136 -
1137 -* AI word address and Ibit address are read-only and cannot be written on HMI.
1138 -* VW address should be even number.such as VW0, VW2, VW4...
1139 -* VD address it takes two VW addresses.such as VD0,VD4,VD8...
1140 -* Written value of RTC cannot exceed 255.
1141 -
1142 -**Cable Wiring**
1143 -
1144 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1145 -
1146 -= Create communication with **Mitsubishi** =
1147 -
1148 -== **FX1S, 1N, 2N Series Protocol** ==
1149 -
1150 1150  Supported Series: Mitsubishi FX1S, FX1N, FX2N series
1151 1151  
1152 1152  **HMI Settings**
... ... @@ -1198,7 +1198,7 @@
1198 1198  
1199 1199  **✎Note:** COM3 only available in PI8000/PI9000 series.
1200 1200  
1201 -== **FX5U Ethernet Protocol** ==
654 +== **FX5U Ethernet** ==
1202 1202  
1203 1203  Mitsubishi FX5U series PLC
1204 1204  
... ... @@ -1277,7 +1277,7 @@
1277 1277  (% style="text-align:center" %)
1278 1278  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1279 1279  
1280 -== **FX5U Serial Port Protocol** ==
733 +== **FX5U Serial Port** ==
1281 1281  
1282 1282  Mitsubishi FX5U series PLC
1283 1283  
... ... @@ -1369,7 +1369,7 @@
1369 1369  
1370 1370  **✎Note:** COM3 only available in PI8000/PI9000 series.
1371 1371  
1372 -== **L02 MELSEC (Ethernet) Protocol** ==
825 +== **L02 MELSEC (Ethernet)** ==
1373 1373  
1374 1374  Mitsubishi Q series CPU built-in Ethernet port.
1375 1375  
... ... @@ -1454,7 +1454,7 @@
1454 1454  (% style="text-align:center" %)
1455 1455  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1456 1456  
1457 -== **QJ71E71 MELSEC Protocol** ==
910 +== **QJ71E71 MELSEC** ==
1458 1458  
1459 1459  Mitsubishi QJ71E71 Ethernet communication module;
1460 1460  
... ... @@ -2219,6 +2219,559 @@
2219 2219  
2220 2220  **✎Note:** COM3 only available in PI8000/PI9000 series.
2221 2221  
1675 += **Siemens** =
1676 +
1677 +== **S7-200 Smart Ethernet** ==
1678 +
1679 +Supported Series: Siemens S7-200 SMART Series Ethernet Module.
1680 +
1681 +Website: [[http:~~/~~/www.siemens.com/entry/cc/en/>>url:http://www.siemens.com/entry/cc/en/]]
1682 +
1683 +**HMI Setting**
1684 +
1685 +(% class="table-bordered" %)
1686 +|**Items**|**Settings**|**Note**
1687 +|Protocol|Simens S7-200 Smart Ethernet|
1688 +|Connection|Ethernet|
1689 +|Port No.|102|
1690 +|PLC station No.|2|
1691 +
1692 +**Address List**
1693 +
1694 +(% class="table-bordered" %)
1695 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
1696 +|(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
1697 +|Q|Q|Q ddddd.o|0.0~~99999.7|
1698 +|V|VWbit|VWbit ddddd.o|0.0~~99999.7|
1699 +|V|V|V ddddd.o|0.0~~99999.7|
1700 +|M|M|M ddddd.o|0.0~~99999.7|
1701 +|SM|SM|ddddd.o|0.0~~99999.7|
1702 +|S|S|ddddd.o|0.0~~99999.7|Read only
1703 +|T|T|ddddd|0~~99999|Timer state, read only
1704 +|C|C|ddddd|0~~99999|Counter state, read only
1705 +|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999|
1706 +|Q|QW|QW ddddd|0~~99999|
1707 +|AI|AIW|AIW ddddd|0~~99999|
1708 +|AQ|VB|VB ddddd|0~~99999|
1709 +|V|VW|VW ddddd|0~~99998|(((
1710 +VW0=VB (0~~1)
1711 +
1712 +VW2=VB (2~~3)
1713 +
1714 +Address value is a multiple of 2
1715 +)))
1716 +|V|VD|VD ddddd|0~~99998|(((
1717 +VD0=VB (0~~3)
1718 +
1719 +VD2=VB (4~~7)
1720 +
1721 +Address value is a multiple of 4
1722 +)))
1723 +|M|MB|MB ddddd|0~~99999|
1724 +|M|MW|MW ddddd|0~~99999|(((
1725 +MW0=MB(0~~1)
1726 +
1727 +MW2=MB(2~~3)
1728 +
1729 +Address value is a multiple of 2
1730 +)))
1731 +|M|MD|MD ddddd|0~~99999|(((
1732 +MD0=MB(0~~3)
1733 +
1734 +MD4=MB(4~~7)
1735 +
1736 +Address value is a multiple of 4
1737 +)))
1738 +|T|TW|TW ddddd|0~~99999|Value of timer
1739 +|C|CW|CW ddddd|0~~99999|Value of counter
1740 +|W|SW|SW ddddd|0~~99999|
1741 +
1742 +**Communication Settings**
1743 +
1744 +Enable HMI Ethernet in [Project Settings];
1745 +
1746 +(% style="text-align:center" %)
1747 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1748 +
1749 +Set PLC IP in [Device IP] settings;
1750 +
1751 +(% style="text-align:center" %)
1752 +[[image:12.PLC Protocol_html_70b0c4c2ee21b10d.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
1753 +
1754 +* PLC IP Address: PLC IP
1755 +* PLC pot No.: 102(fixed)
1756 +* Network:TCP_Client_2N(fixed)
1757 +
1758 +(% style="text-align:center" %)
1759 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
1760 +
1761 +* Wait timeout: depend on actual network situation (more than 1500 ms)
1762 +
1763 +**Cable Wiring**
1764 +
1765 +(% style="text-align:center" %)
1766 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1767 +
1768 +== **S7-300 Ethernet** ==
1769 +
1770 +Supported Series: Siemens S7-300 series PLC
1771 +
1772 +**HMI Setting**
1773 +
1774 +(% class="table-bordered" %)
1775 +|**Items**|**Settings**|**Note**
1776 +|Protocol|Simens S7-300 Ethernet|
1777 +|Connection|Ethernet|
1778 +|Port No.|102|
1779 +|PLC station No.|2|Need to be same as the PLC setting
1780 +
1781 +**Address List**
1782 +
1783 +(% class="table-bordered" %)
1784 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
1785 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
1786 +|Q|Q|Q ddddd.o|0.0~~99999.7|
1787 +|M|M|M ddddd.o|0.0~~99999.7|
1788 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
1789 +nn: block number;
1790 +
1791 +dddd: address;
1792 +)))
1793 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
1794 +|Q|QW|QW ddddd|0~~99999|
1795 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
1796 +|MW|MW ddddd|0~~99999|(((
1797 +MW0=MB(0~~1)
1798 +
1799 +MW2=MB(2~~3)
1800 +
1801 +Address value is a multiple of 2
1802 +)))
1803 +|MD|MD ddddd|0~~99999|(((
1804 +MD0=MB(0~~3)
1805 +
1806 +MD4=MB(4~~7)
1807 +
1808 +Address value is a multiple of 4
1809 +)))
1810 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
1811 +nn: block number;
1812 +
1813 +dddd: address
1814 +)))
1815 +|DBxDBW|DBxDBW nndddd|0~~99999999
1816 +|DBxDBD|DBxDBD nndddd|0~~99999999
1817 +
1818 +**Communication Settings**
1819 +
1820 +Enable HMI Ethernet in [Project Settings];
1821 +
1822 +(% style="text-align:center" %)
1823 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1824 +
1825 +Set PLC IP in [Device IP] settings;
1826 +
1827 +(% style="text-align:center" %)
1828 +[[image:12.PLC Protocol_html_910b1a0aa9e2201c.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]]
1829 +
1830 +* PLC IP Address: PLC IP
1831 +* PLC pot No.: 102(fixed)
1832 +* Network:TCP_Client_2N(fixed)
1833 +
1834 +(% style="text-align:center" %)
1835 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
1836 +
1837 +* Wait timeout: depend on actual network situation (more than 1500 ms)
1838 +
1839 +**Cable Wiring**
1840 +
1841 +(% style="text-align:center" %)
1842 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1843 +
1844 +== **S7-1200 Ethernet** ==
1845 +
1846 +Supported Series: Siemens S7-1200
1847 +
1848 +**HMI Setting**
1849 +
1850 +(% class="table-bordered" %)
1851 +|**Items**|**Settings**|**Note**
1852 +|Protocol|Siemens S7-1200|
1853 +|Connection|Ethernet|
1854 +|Port No.|102|
1855 +|PLC station No.|2|
1856 +
1857 +**Address List**
1858 +
1859 +(% class="table-bordered" %)
1860 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
1861 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
1862 +d:0~-~-9999
1863 +
1864 +o:0-7
1865 +)))|
1866 +|Q|Q|Q d.o|(((
1867 +d:0~-~-9999
1868 +
1869 +o:0-7
1870 +)))|
1871 +|M|M|M d.o|(((
1872 +d:0~-~-9999
1873 +
1874 +o:0-7
1875 +)))|
1876 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
1877 +nn:0-9999,
1878 +
1879 +dddd:0-9999,
1880 +
1881 +o:0-7
1882 +)))|(((
1883 +nn:DB No.
1884 +
1885 +dddd:address value
1886 +
1887 +o: digit address
1888 +)))
1889 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
1890 +|M|MW|MW d|d:0-99999|(((
1891 +MW0=MB(0~~1)
1892 +
1893 +MW2=MB(2~~3)
1894 +
1895 +Address value is a multiple of 2
1896 +)))
1897 +|M|MD|MD d|d:0-99999|(((
1898 +MD0=MB(0~~3)
1899 +
1900 +MD4=MB(4~~7)
1901 +
1902 +Address value is a multiple of 4
1903 +)))
1904 +|I|IW|IW d|d:0-99999|
1905 +|Q|QW|QW d|d:0-99999|
1906 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
1907 +nn:0-9999
1908 +
1909 +dddd:0-9999
1910 +)))|(((
1911 +nn:DB No.
1912 +
1913 +dddd:address value
1914 +)))
1915 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
1916 +nn:0-9999
1917 +
1918 +dddd:0-9999
1919 +)))|(((
1920 +nn:DB No.
1921 +
1922 +dddd:address value
1923 +
1924 +Address value is a multiple of 2
1925 +)))
1926 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
1927 +nn:0-9999
1928 +
1929 +dddd:0-9999
1930 +)))|(((
1931 +nn:DB No.
1932 +
1933 +dddd:address value
1934 +
1935 +Address value is a multiple of 4
1936 +)))
1937 +
1938 +**Communication Settings**
1939 +
1940 +Enable HMI Ethernet in [Project Settings];
1941 +
1942 +(% style="text-align:center" %)
1943 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1944 +
1945 +Set PLC IP in [Device IP] settings;
1946 +
1947 +(% style="text-align:center" %)
1948 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
1949 +
1950 +**✎Note:**
1951 +
1952 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
1953 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
1954 +
1955 +**PLC Settings**
1956 +
1957 +Add BD
1958 +
1959 +* Please uncheck [Symbolic access only] option;
1960 +
1961 +(% style="text-align:center" %)
1962 +[[image:12.PLC Protocol_html_643144c591994418.png||data-xwiki-image-style-alignment="center" height="546" width="550" class="img-thumbnail"]]
1963 +
1964 +Address settings, using BD2 as example.
1965 +
1966 +* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1.
1967 +* 2 represent DB block number
1968 +* xxxx represent address
1969 +
1970 +**Such as:**
1971 +
1972 +* DBxDBB20000 = DB2.DBB0
1973 +* DBxDBW20004 = DB2.DBW4
1974 +
1975 +(% style="text-align:center" %)
1976 +[[image:12.PLC Protocol_html_87ceaea84d552e62.png||data-xwiki-image-style-alignment="center" height="245" width="537" class="img-thumbnail"]]
1977 +
1978 +**How to connect with S7-1200 Firmware V4.0**
1979 +
1980 +PLC configuration
1981 +
1982 +* Double click [device configuration] in Siemens via software
1983 +* Double click [protection] to enter protection configuration screen
1984 +
1985 +(% style="text-align:center" %)
1986 +[[image:12.PLC Protocol_html_9779940d38da8e07.png||data-xwiki-image-style-alignment="center" height="426" width="341" class="img-thumbnail"]]
1987 +
1988 +* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)]
1989 +
1990 +(% style="text-align:center" %)
1991 +[[image:12.PLC Protocol_html_d2c667b02f9720b1.png||data-xwiki-image-style-alignment="center" height="296" width="554" class="img-thumbnail"]]
1992 +
1993 +DB settings
1994 +
1995 +* Right click [DB], select [properties]
1996 +* Uncheck [optimized block access]
1997 +
1998 +**Cable Wiring**
1999 +
2000 +(% style="text-align:center" %)
2001 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2002 +
2003 +== **LOGO Ethernet** ==
2004 +
2005 +Supported Series: Siemens Logo 0BA0 series
2006 +
2007 +**HMI Settings**
2008 +
2009 +(% class="table-bordered" %)
2010 +|**Items**|**Settings**|**Note**
2011 +|Protocol|Siemens LOGO|
2012 +|Connection|Ethernet|
2013 +|Port No.|102|
2014 +|PLC station No.|2|
2015 +
2016 +**Address List**
2017 +
2018 +(% class="table-bordered" %)
2019 +|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
2020 +|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
2021 +|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
2022 +|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
2023 +|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
2024 +|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
2025 +|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
2026 +|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
2027 +|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
2028 +|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
2029 +|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
2030 +|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
2031 +|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
2032 +|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
2033 +|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
2034 +|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
2035 +
2036 +**PLC Settings in LOGO Software:**
2037 +
2038 +Click [Tools]~-~-[Ethernet Connections],shown as below.
2039 +
2040 +(% style="text-align:center" %)
2041 +[[image:12.PLC Protocol_html_8b9d2322edf89519.png||data-xwiki-image-style-alignment="center" height="641" width="423" class="img-thumbnail"]]
2042 +
2043 +Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
2044 +
2045 +(% style="text-align:center" %)
2046 +[[image:12.PLC Protocol_html_6c4dd041b26cd8a1.png||data-xwiki-image-style-alignment="center" height="481" width="363" class="img-thumbnail"]]
2047 +
2048 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
2049 +
2050 +(% style="text-align:center" %)
2051 +[[image:12.PLC Protocol_html_7af2611d3790a77d.png||data-xwiki-image-style-alignment="center" height="359" width="426" class="img-thumbnail"]]
2052 +
2053 +**Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
2054 +
2055 +(% style="text-align:center" %)
2056 +[[image:12.PLC Protocol_html_3243e4cd600595cc.png||data-xwiki-image-style-alignment="center" height="368" width="554" class="img-thumbnail"]]
2057 +
2058 +
2059 +(% style="text-align:center" %)
2060 +[[image:12.PLC Protocol_html_cb1d92e2cc91a8db.png||data-xwiki-image-style-alignment="center" height="320" width="553" class="img-thumbnail"]]
2061 +
2062 +
2063 +**HMI Communication Settings**
2064 +
2065 +Set PLC IP in [Device IP] settings;
2066 +
2067 +(% style="text-align:center" %)
2068 +[[image:SiemensLOGODeviceIP.png]]
2069 +
2070 +Enable HMI Ethernet in [Project Settings];
2071 +
2072 +(% style="text-align:center" %)
2073 +[[image:12.PLC Protocol_html_95917a3d92068467.png||data-xwiki-image-style-alignment="center" height="311" width="553" class="img-thumbnail"]]
2074 +
2075 +TSAP setting
2076 +
2077 +* Regarding the setting of PLC TSAP, HMI provides system special address for setting, it is recommended to run in HMI script initialization, write PLC TSAP to corresponding system special register.
2078 +* HSW10118 = local TSAP of HMI, this is remote TSAP of PLC.
2079 +* HSW10119 = Remote TSAP of HMI, this is local TSAP of PLC.
2080 +
2081 +**✎Note:**
2082 +
2083 +* The data of TSAP is hexadecimal format. For example: the remote TSAP configured in the PLC is set to 20.00, then HSW10118 should be set to 0x2000, that is, HSW10118 = 8192.
2084 +
2085 +(% style="text-align:center" %)
2086 +[[image:12.PLC Protocol_html_5c6374b21f46e01e.png||data-xwiki-image-style-alignment="center" height="139" width="498" class="img-thumbnail"]]
2087 +
2088 +
2089 +* AI word address and Ibit address are read-only and cannot be written on HMI.
2090 +* VW address should be even number.such as VW0, VW2, VW4...
2091 +* VD address it takes two VW addresses.such as VD0,VD4,VD8...
2092 +* Written value of RTC cannot exceed 255.
2093 +
2094 +**Cable Wiring**
2095 +
2096 +(% style="text-align:center" %)
2097 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2098 +
2099 +== **S7-XXX Ethernet** ==
2100 +
2101 +Supported Series: Siemens S7-400, S7-1200 and S7-1500
2102 +
2103 +**HMI Setting**
2104 +
2105 +(% class="table-bordered" style="width:823px" %)
2106 +|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note**
2107 +|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %)
2108 +|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %)
2109 +|Port No.|(% style="width:437px" %)102|(% style="width:201px" %)
2110 +|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %)
2111 +|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %)
2112 +
2113 +Slot from TIA Portal is equal to Device No. of PIStudio
2114 +
2115 +Rack from TIA Portal is equal to HMI No. of PIStudio
2116 +
2117 +(% style="text-align:center" %)
2118 +[[image:S7-XXXCommunication Settings.png]]
2119 +
2120 +(% style="text-align:center" %)
2121 +[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]]
2122 +
2123 +**Address List**
2124 +
2125 +(% class="table-bordered" %)
2126 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
2127 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
2128 +d:0~-~-9999
2129 +
2130 +o:0-7
2131 +)))|
2132 +|Q|Q|Q d.o|(((
2133 +d:0~-~-9999
2134 +
2135 +o:0-7
2136 +)))|
2137 +|M|M|M d.o|(((
2138 +d:0~-~-9999
2139 +
2140 +o:0-7
2141 +)))|
2142 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
2143 +nn:0-9999,
2144 +
2145 +dddd:0-9999,
2146 +
2147 +o:0-7
2148 +)))|(((
2149 +nn:DB No.
2150 +
2151 +dddd:address value
2152 +
2153 +o: digit address
2154 +)))
2155 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
2156 +|M|MW|MW d|d:0-99999|(((
2157 +MW0=MB(0~~1)
2158 +
2159 +MW2=MB(2~~3)
2160 +
2161 +Address value is a multiple of 2
2162 +)))
2163 +|M|MD|MD d|d:0-99999|(((
2164 +MD0=MB(0~~3)
2165 +
2166 +MD4=MB(4~~7)
2167 +
2168 +Address value is a multiple of 4
2169 +)))
2170 +|I|IW|IW d|d:0-99999|
2171 +|Q|QW|QW d|d:0-99999|
2172 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
2173 +nn:0-9999
2174 +
2175 +dddd:0-9999
2176 +)))|(((
2177 +nn:DB No.
2178 +
2179 +dddd:address value
2180 +)))
2181 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
2182 +nn:0-9999
2183 +
2184 +dddd:0-9999
2185 +)))|(((
2186 +nn:DB No.
2187 +
2188 +dddd:address value
2189 +
2190 +Address value is a multiple of 2
2191 +)))
2192 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
2193 +nn:0-9999
2194 +
2195 +dddd:0-9999
2196 +)))|(((
2197 +nn:DB No.
2198 +
2199 +dddd:address value
2200 +
2201 +Address value is a multiple of 4
2202 +)))
2203 +
2204 +**Communication Settings**
2205 +
2206 +Enable HMI Ethernet in [Project Settings];
2207 +
2208 +(% style="text-align:center" %)
2209 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]]
2210 +
2211 +Set PLC IP in [Device IP] settings;
2212 +
2213 +(% style="text-align:center" %)
2214 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
2215 +
2216 +**✎Note:**
2217 +
2218 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
2219 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
2220 +
2221 +**Cable Wiring**
2222 +
2223 +{{id name="OLE_LINK8"/}}
2224 +
2225 +(% style="text-align:center" %)
2226 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2227 +
2222 2222  = **User Defined Protocol** =
2223 2223  
2224 2224  If the device does not support MODBUS standard, and the protocol is not list in PIStudio, then user can define the protocol by following instruction to realize simply communication functions like sending and receiving commands.
... ... @@ -2842,5 +2842,3 @@
2842 2842  [[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
2843 2843  
2844 2844  **Cable Wiring**