Contact us for more information
X
*Company Name
*Name
*Email Address
Country
WhatsApp Number
*Detailed Description of Technical Question

Wiki source code of 11 PLC Protocol

Version 9.1 by Stone Wu on 2022/08/05 11:45

Show last authors
1 (((
2 (% class="wikigeneratedid" id="HPLCprotocols" %)
3 **Introduction**
4 )))
5
6 This chapter contains information on configuring the communication between device and HMI.
7
8 **General Procedure**
9
10 During configuring communication in PIStudio. The following components and conditions is indeed at least.
11
12 * One PI HMI
13 * One connected controller (for example PLC)
14 * One Cable Wiring
15
16 (% style="text-align:center" %)
17 [[image:12.PLC Protocol_html_4d84fc52012aaad6.png||data-xwiki-image-style-alignment="center" height="461" width="521" class="img-thumbnail"]]
18
19 User need to select controller protocol and set communication parameters in HMI project. Please note to set same communication parameter between controller and HMI project. After finishing project, user could download HMI project into HMI and connect HMI with controller by Cable Wiring. Thena simple automation system would be established.
20
21 = **Communication Settings** =
22
23 For example, controller is WECON LX3V series PLC and HMI is PI8070. Please set communication protocol, and set communication parameters in the [Communication].
24
25 **Timeout**
26
27 The follwoing are description for the timeout settings from [Communication].
28
29 (% style="text-align:center" %)
30 [[image:Communication Timout settings.png||data-xwiki-image-style-alignment="center" class="img-thumbnail"]]
31
32 * Wait Timeout(ms): The time HMI waits for a response from the PLC.
33 * Receive Timeout(ms): The longest waiting interval between the HMI receiving two characters.
34 * Retry Count: The number of retries when there is no response in the communication between HMI and PLC.
35 * Retry Timeout(s): The PLC will not be accessed during the Retry Timeout period when there is no response in the communication between HMI and PLC.
36 * Delay Time(ms): The speed at which the HMI communicates with the device.
37 * Continuous Length: Default value 0 means the maximum length specified by each protocol. Addresses dealt by Maximum Span settings, its read length for single time, if the Continouous Length is 1, which means it will read/write the every register one by one. If the length of Maximum Span is greater than or equal to the Continuous Length, the continuous read/write will be performed in groups according to Continuous Length.
38 * Maximum Span:  Set the interval for reading PLC addresses. If there exists two same register type addresses, their interval is less than the set value of Maximum Span, then they will be integrated into a continuous address, otherwise it will be divide into two independent addresses.
39
40 **Operating Procedure**
41
42 After creating the [Quick_Start] project,select the [Project]->[Communication].
43
44 (% style="text-align:center" %)
45 [[image:12.PLC Protocol_html_39c0d342e4b1dd27.png||data-xwiki-image-style-alignment="center" height="128" width="294" class="img-thumbnail"]]
46
47 Click “Setting” to open protocol setting windows.
48
49 (% id="cke_bm_5533S" style="display:none" %) [[image:12.PLC Protocol_html_7b55815442c5544a.png||height="450" width="537"]]
50
51 Select communication protocol, users could select serial port, Ethernet port, CAN port or USB.
52
53 * Serial port:
54
55 (% style="text-align:center" %)
56 [[image:12.PLC Protocol_html_bc7e88067e699a2b.png||data-xwiki-image-style-alignment="center" height="291" width="600" class="img-thumbnail"]]
57
58 * Ethernet port:
59
60 (% style="text-align:center" %)
61 [[image:12.PLC Protocol_html_c3865bcb998b6ded.png||data-xwiki-image-style-alignment="center" height="291" width="600" class="img-thumbnail"]]
62
63 * CAN port (In COM1):
64
65 (% style="text-align:center" %)
66 [[image:12.PLC Protocol_html_61c3c5fa99a24463.png||data-xwiki-image-style-alignment="center" height="291" width="600" class="img-thumbnail"]]
67
68 * USB port:
69
70 (% id="cke_bm_5554S" style="display:none" %) [[image:12.PLC Protocol_html_a3105a98b48fb9b7.png||height="242" width="500"]]
71
72 About parameters for communication, PLC default communication parameters have been written to PIStudio, the user can adjust them according to the actual situation.
73
74 * Serial port:
75
76 (% style="text-align:center" %)
77 [[image:12.PLC Protocol_html_36a660d5c1a17a95.png||data-xwiki-image-style-alignment="center" height="228" width="600" class="img-thumbnail"]]
78
79 * Ethernet port
80
81 Please note, during using Ethernet port, please set HMI IP in [Project Setting], the detailed, please refer to [Project Setting] chapter.
82
83 (% style="text-align:center" %)
84 [[image:12.PLC Protocol_html_eebfc6b1337ea860.png||data-xwiki-image-style-alignment="center" height="207" width="600" class="img-thumbnail"]]
85
86 Click [OK] button to save settings and close the dialog;
87
88 = **Allen-Bradley** =
89
90 == **FreeTag Ethernet/IP (CompactLogix)** ==
91
92 Allen-Brandly CompactLogix
93
94 **HMI Settings**
95
96 (% class="table-bordered" %)
97 |**Items**|**Settings**|**Note**
98 |Protocol|Allen-Brandley FreeTag Ethernet/IP (CompactLogix)|
99 |Connection|Ethernet|
100 |Port No.|44818|
101
102 **PLC Setting**
103
104 Create new tags
105
106 (% style="text-align:center" %)
107 [[image:12.PLC Protocol_html_a748a27dcf7f1124.png||data-xwiki-image-style-alignment="center" height="411" width="700" class="img-thumbnail"]]
108
109 Export tags to CSV file. ([Tools] » [Export] » [Tags and Logic Comments])
110
111 (% style="text-align:center" %)
112 [[image:12.PLC Protocol_html_151379170bb8ff3e.png||data-xwiki-image-style-alignment="center" height="352" width="700" class="img-thumbnail"]]
113
114 Import labels, please open [Communication] window and click [Import label];
115
116 Select csv file, all tags will be displayed as belows;
117
118 (% style="text-align:center" %)
119 [[image:12.PLC Protocol_html_af192e54dee96f38.png||data-xwiki-image-style-alignment="center" height="586" width="700" class="img-thumbnail"]]
120
121 **✎Note:**
122
123 Because in different region, the separation symbol is different, we suggest you check this before you want to import your tags. To open csv file as text format.
124
125 (% style="text-align:center" %)
126 [[image:12.PLC Protocol_html_33df1d63ebe53726.png||data-xwiki-image-style-alignment="center" height="206" width="700" class="img-thumbnail"]]
127
128 The directory of changing system settings: [Control Panel] -> [Date, Time, Language,and Regional Options] -> [Change the format of numbers, dates, and times]->[Customize]-> [List separator]. Please select [,] and export CSV file after setting.
129
130 **Communication settings in HMI**
131
132 Enable HMI Ethernet in [Project Settings];
133
134 (% style="text-align:center" %)
135 [[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="106" width="400" class="img-thumbnail"]]
136
137 Set PLC IP in [Device IP] settings;
138
139 (% style="text-align:center" %)
140 [[image:12.PLC Protocol_html_27870d373581892e.png||data-xwiki-image-style-alignment="center" height="206" width="600" class="img-thumbnail"]]
141
142 **Cable Wiring**
143
144 (% style="text-align:center" %)
145 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]]
146
147 == **MicroLogix** ==
148
149 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
150
151 **HMI Settings**
152
153 (% class="table-bordered" %)
154 |**Item**|**Settings**|**Note**
155 |Protocol|Allen-Bradlley MicroLogix|
156 |Connection|RS232|
157 |Baud rate|19200|
158 |Data bit|8|
159 |Parity|None|
160 |Stop bit|1|
161 |PLC station No.|1|
162
163 **Address List**
164
165 (% class="table-bordered" %)
166 |**Type**|**Device registers**|**Format**|**Range**|**Note**
167 |(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
168 |O|O d.d|0.0~~255.15|
169 |B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
170 |S|S d.d|0.0~~255.15|
171 |N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
172 |(% rowspan="9" %)Word|S|S d|0~~255|
173 |TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
174 |TP|TP nnhh|0~~ffff
175 |CS|CS nnhh|0~~ffff
176 |CP|CP nnhh|0~~ffff
177 |N|N nnhh|0~~ffff
178 |C|C nnhh|0~~ffff
179 |T|T nnhh|0~~ffff
180 |R|R nnhh|0~~ffff
181
182 **Cable Wiring**
183
184 (% style="text-align:center" %)
185 [[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]]
186
187 == **AB PLC address edit** ==
188
189 The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200.
190
191 * **Bit address I:** The address ranges from 0.0 to 255.15. The value of the data before the decimal point ranges from 0 to 255 (decimal). The value from 0 to 15 after the decimal point is the sub address (decimal).
192 * **Bit address B:** The address ranges from 000.0 to fff.15. The first f from left to right represents the block number (hexadecimal); The second and third f from left to right represent the word address (hexadecimal). The value 0 to 15 after the decimal point reprensents the sub address (decimal).
193 * **Word address S:** The word address ranges from 0 to 255 (decimal).
194 * **Word address TS:** The address ranges from 000.0 to ffff. The first and second f from left to right represents the block number (hexadecimal); The third and fourth f from left to right represent the word address (hexadecimal).
195
196 **✎Note: **Register address TP, CS, CP, N, F and TS address edit tare he same. D indicates decimal, and F indicates hexadecimal. Different PLC models may support different registers. See the following table.
197
198 |(% style="width:393px" %)**PLC bit address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range**
199 |(% style="width:393px" %)I|(% style="width:350px" %)dd.dd|(% style="width:333px" %)I 0.0 ~~ 255.15
200 |(% style="width:393px" %)O|(% style="width:350px" %)dd.dd|(% style="width:333px" %)O 0.0 ~~ 255.15
201 |(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15
202 |(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15
203 |(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15
204 |(% style="width:393px" %)**PLC word address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range**
205 |(% style="width:393px" %)S|(% style="width:350px" %)ddd|(% style="width:333px" %)S0 ~~ 255
206 |(% style="width:393px" %)TS|(% style="width:350px" %)ffff|(% style="width:333px" %)TS0 ~~ FFFF
207 |(% style="width:393px" %)TP|(% style="width:350px" %)ffff|(% style="width:333px" %)TP0 ~~ FFFF
208 |(% style="width:393px" %)CS|(% style="width:350px" %)ffff|(% style="width:333px" %)CS0 ~~ FFFF
209 |(% style="width:393px" %)CP|(% style="width:350px" %)ffff|(% style="width:333px" %)CP0 ~~ FFFF
210 |(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF
211 |(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF
212
213 = **Barcode Scanner** =
214
215 Supported: DELI 14880 barcode scanner
216
217 **HMI Setting**
218
219 (% class="table-bordered" %)
220 |**Items**|**Settings**|**Note**
221 |Protocol|Barcode Scanner|
222 |Connection|USB|
223
224 **Operating Procedures**
225
226 Select [Barcode Scanner];
227
228 (% style="text-align:center" %)
229 [[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
230
231 Set address for receiving;
232
233 Set correct length;
234
235 (% style="text-align:center" %)
236 [[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
237
238 **✎Note:**
239
240 * The protocol uploads the information acquired by the USB scanner to the HMI;
241 * The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
242 * Recommended model: DELI 14880 barcode scanner;
243
244 = **Hitachi EHV Series (Ethernet)** =
245
246 Supported series: Hitachi EHV series
247
248 **HMI Settings**
249
250 (% class="table-bordered" %)
251 |**Items**|**Settings**|**Note**
252 |Protocol|Hitachi EHV series|
253 |Connection|Ethernet|
254 |Port No.|3004~~3007|
255
256 **Address List**
257
258 (% class="table-bordered" %)
259 |**Type**|**Register**|**Range**|**Format**|**Note**
260 |(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
261 |M|0 - 7FFF.f (Hex)|M HHHH.h|
262 |X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
263 H1H2H3H4 Module main number
264
265 H1: Remote number
266
267 H2: Unit number
268
269 H3: Slot number
270
271 H4: Word number of Module
272
273 H Sub number of Module
274
275 For example:X21.3
276
277 Slot number 2
278
279 Word number of module is 1
280
281 Bit number of module is 3
282
283 Remote number and unit number are 0
284 )))
285 |Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
286 |R|0 – FF.f (Hex)|R HH.h|
287 |L|0 - 73FF.f (Hex)|L HHHH.h|
288 |(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
289 |WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
290 H1H2H3H4 Module main number
291
292 H1: Remote number
293
294 H2: Unit number
295
296 H3: Slot number
297
298 H4: Word number of module
299
300 For example:WX21
301
302 Word number of module is 1
303
304 Slot number is 2
305
306 Remote number and unit number are 0
307 )))
308 |WY|0 – FFFF (Hex)|WY H1H2H3H4
309 |WR|0 – FFFF (Hex)|WR HHHH|
310 |WL|0 - 73FF (Hex)|WL HHHH|
311 |TC|0 - 2559|TC DDDD|
312
313 **Communication settings in HMI**
314
315 Enable HMI Ethernet in [Project Settings];
316
317 (% style="text-align:center" %)
318 [[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
319
320 Set PLC IP in [Device IP] settings;
321
322 (% style="text-align:center" %)
323 [[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
324
325 **PLC Configuration**
326
327 Connect with PLC, select[Online mode];
328
329 (% style="text-align:center" %)
330 [[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
331
332 Set IP address, it is the same LAN parameters with HMI;
333
334 (% style="text-align:center" %)
335 [[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
336
337 3) Save PLC communication parameter, and restart PLC
338
339 **PLC Monitor Mode**
340
341 Connect with PLC and choose to “online” mode
342
343 (% style="text-align:center" %)
344 [[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
345
346 Open I/O monitor sheet1
347
348 (% style="text-align:center" %)
349 [[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
350
351 During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
352
353 (% style="text-align:center" %)
354 [[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
355
356 Enter the register address, click OK to view the value of the register.
357
358 (% style="text-align:center" %)
359 [[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
360
361 (% style="text-align:center" %)
362 [[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
363
364 **✎Note:**
365
366 * Both word registers and bit registers support even continuous read/write functions;
367 * The range of registers is based on the specific PLC type;
368
369 **Cable Wiring**
370
371 (% style="text-align:center" %)
372 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
373
374 = **IEC60870-5 104 Client** =
375
376 **HMI Setting**
377
378 (% class="table-bordered" %)
379 |**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
380 |Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
381 |Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
382 |Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
383
384 **Address List**
385
386 (% class="table-bordered" %)
387 |(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
388 |(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
389 |(% style="width:461px" %)SCNA|0~~16777215.7
390 |(% style="width:461px" %)DPTB|0~~16777215.7
391 |(% style="width:461px" %)DCNA|0~~16777215.7
392 |(% style="width:461px" %)METF|0~~16777215.7
393 |(% style="width:461px" %)SENC|0~~16777215.7
394 |(% style="width:461px" %)SENA|0~~16777215.7
395 |(% style="width:461px" %)MENA|0~~16777215.7
396 |(% style="width:461px" %)METD|0~~16777215.7
397 |(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
398 |(% style="width:461px" %)SCNA|0~~16777215
399 |(% style="width:461px" %)DPTB|0~~16777215
400 |(% style="width:461px" %)DCNA|0~~16777215
401 |(% style="width:461px" %)SENA|0~~16777215
402 |(% style="width:461px" %)MENA|0~~16777215
403 |(% style="width:461px" %)METD|0~~16777215
404 |(% style="width:461px" %)INRO|0~~16777215
405 |(% style="width:461px" %)TIMESYN|0~~16777215
406 |(% style="width:461px" %)TIMEZ|0~~16777215
407 |(% style="width:461px" %)NTP|0~~16777215
408 |(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
409 |(% style="width:461px" %)SENC|0~~16777215
410
411 **Address Configuration**
412
413 The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
414
415 (% style="text-align:center" %)
416 [[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
417
418 (% style="text-align:center" %)
419 [[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
420
421 Extended tag name
422
423 Address range for the extended tag.
424
425 **Communication Settings**
426
427 Enable HMI Ethernet in [Project Settings];
428
429 (% style="text-align:center" %)
430 [[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
431
432 Set PLC IP in [Device IP] settings;
433
434 (% style="text-align:center" %)
435 [[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
436
437 **Cable Wiring**
438
439 (% style="text-align:center" %)
440 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
441
442 = **LG XGK FEnet Ethernet** =
443
444 Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
445
446 **HMI Settings**
447
448 (% class="table-bordered" %)
449 |**Items**|**Settings**|**Note**
450 |Protocol|LG XGK FEnet(Ethernet)|
451 |Connection|Ethernet|
452 |Port No.|2004|
453
454 **Address List**
455
456 (% class="table-bordered" %)
457 |**Type**|**Register**|**Range**|**Format**|**Note**
458 |(% rowspan="14" %)Word|P|0~~2047|P d|
459 |M|0~~2047|M d|
460 |K|0~~2047|K d|
461 |F|0~~2047|F d|
462 |T|0~~2047|T d|
463 |C|0~~2047|C d|
464 |Z|0~~127|Z d|
465 |S|0~~127|S d|
466 |L|0~~11263|L d|
467 |N|0~~21503|N d|
468 |D|0~~32767|D d|
469 |R|0~~32767|R d|
470 |ZR|0~~65535|ZR d|
471 |UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
472
473 **✎Note:**
474
475 * In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
476 * The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
477 * All bit registers are in the form of bits in word, and the range is the same as the word register;
478
479 **Communication settings in HMI**
480
481 Enable HMI Ethernet in [Project Settings];
482
483 (% style="text-align:center" %)
484 [[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
485
486 Set PLC IP in [Device IP] settings;
487
488 (% style="text-align:center" %)
489 [[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
490
491 **Cable Wiring**
492
493 = **Mitsubishi** =
494
495 == **FX1S, 1N, 2N Series** ==
496
497 Supported Series: Mitsubishi FX1S, FX1N, FX2N series
498
499 **HMI Settings**
500
501 (% class="table-bordered" %)
502 |**Item**|**Settings**|**Note**
503 |Protocol|Mitsubishi FX1S/FX1N/FX2N|
504 |Connection|RS422/RS485/RS232|
505 |Baud rate|9600~~115200|
506 |Data bit|7/8|
507 |Parity|EVEN/Odd/None|
508 |Stop bit|1/2|
509 |PLC station No.|1~~255|
510
511 **Address List**
512
513 (% class="table-bordered" %)
514 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
515 |(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
516 |Y|Y|Y o|0~~303237|
517 |M|M|M d|0~~99999|
518 |T|T|T d|0~~99999|
519 |C|C|C d|0~~99999|
520 |S|S|S d|0~~99999|
521 |SM|SM|SM d|8000~~9999|
522 |(% rowspan="8" %)Word|X|X|Xo|0~~303237|
523 |Y|Y|Y o|0~~303237|
524 |M|M|M d|0~~99999|
525 |T|T|T d|0~~99999|
526 |C|C|C d|0~~199|
527 |D|D|D d|0~~7999|
528 |S|S|S d|0~~99999|
529 |SD|SD|SD d|8000~~9999|
530
531 **Cable Wiring**
532
533 * **RS485**
534
535 (% style="text-align:center" %)
536 [[image:12.PLC Protocol_html_d4012bdeb4ce4aae.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
537
538 (% style="text-align:center" %)
539 [[image:12.PLC Protocol_html_4bf57ad8d44eacc4.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
540
541 * **RS422**
542
543 (% style="text-align:center" %)
544 [[image:12.PLC Protocol_html_f8a6bebc5792960d.png||data-xwiki-image-style-alignment="center" height="253" width="402" class="img-thumbnail"]]
545
546 **✎Note:** COM3 only available in PI8000/PI9000 series.
547
548 == **FX5U Ethernet** ==
549
550 Mitsubishi FX5U series PLC
551
552 **HMI Settings**
553
554 (% class="table-bordered" %)
555 |**Items**|**Settings**|**Note**
556 |Protocol|Mitsubishi FX5U|
557 |Connection|Ethernet|
558 |Port No.|5002|Must be the same as the PLC setting
559 |PLC station No.|0|
560
561 **Address List**
562
563 (% class="table-bordered" %)
564 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
565 |(% rowspan="15" %)Bit|X|X|X o|0~~303237|
566 |Y|Y|Y o|0~~303237|
567 |M|M|M d|0~~99999|
568 |B|B|B h|0~~7FFF|
569 |F|F|F d|0~~32767|
570 |SB|SB|SB h|0~~7FFF|
571 |TS|TS|TS d|0~~1023|
572 |TC|TC|TC d|0~~1023|
573 |STS|STS|STS d|0~~1023|
574 |STC|STC|STS d|0~~1023|
575 |CS|CS|CS d|0~~1023|
576 |CC|CC|CC d|0~~1023|
577 |SM|SM|SM d|0~~9999|
578 |L|L|L d|0~~32767|
579 |S|S|S d|0~~4095|
580 |(% rowspan="9" %)Word|W|W|W h|0~~3FF|
581 |TN|TN|TN d|0~~1023|
582 |STN|STN|STN d|0~~1023|
583 |CN|CN|CN d|0~~1023|
584 |R|R|R d|0~~32767|
585 |SW|SW|SW h|0~~7FFF|
586 |Z|Z|Z d|0~~23|
587 |D|D|D d|0~~7999|
588 |SD|SD|SD d|0~~11999|
589
590 **PLC Settings (GX Works 3)**
591
592 Find the [Ethernet port] in the navigation area.
593
594 (% style="text-align:center" %)
595 [[image:12.PLC Protocol_html_8e8f85ace087346c.png||data-xwiki-image-style-alignment="center" height="593" width="300" class="img-thumbnail"]]
596
597 Select [Own Node Settings] in the [Setting Item List];
598
599 Set [IP Address], [Subnet Mask], [Default Gateway];
600
601 Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows;
602
603 (% style="text-align:center" %)
604 [[image:12.PLC Protocol_html_5d98495052c8c10e.png||data-xwiki-image-style-alignment="center" height="339" width="600" class="img-thumbnail"]]
605
606 Select [SLMP Connection Module] and add into host station as below picture shows;
607
608 Set Port number as 5002 (this is necessary settings);
609
610 Click [Close with Reflecting the Setting] to save and close window;
611
612 (% style="text-align:center" %)
613 [[image:12.PLC Protocol_html_14b489fdc6c6589d.png||data-xwiki-image-style-alignment="center" height="350" width="600" class="img-thumbnail"]]
614
615 Click [Apply] to completed Etherenet settings;
616
617 Switch to the [On line data operation] interface as below, check the item and click [Execute] to download.
618
619 (% style="text-align:center" %)
620 [[image:12.PLC Protocol_html_c93025a968a8a9e7.png||data-xwiki-image-style-alignment="center" height="434" width="600" class="img-thumbnail"]]
621
622 **Cable Wiring**
623
624 (% style="text-align:center" %)
625 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
626
627 == **FX5U Serial Port** ==
628
629 Mitsubishi FX5U series PLC
630
631 **HMI Settings**
632
633 (% class="table-bordered" %)
634 |**Item**|**Settings**|**Note**
635 |Protocol|Mitsubishi FX5U|
636 |Connection|RS422/RS485|
637 |Baud rate|9600|
638 |Data bit|7|
639 |Parity|Odd|
640 |Stop bit|1|
641 |PLC station No.|1~~255|Need to be the same as PLC settings
642
643 **Address List**
644
645 (% class="table-bordered" %)
646 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
647 |(% rowspan="15" %)Bit|X|X|X o|0~~303237|
648 |Y|Y|Y o|0~~303237|
649 |M|M|M d|0~~99999|
650 |B|B|B h|0~~7FFF|
651 |F|F|F d|0~~32767|
652 |SB|SB|SB h|0~~7FFF|
653 |TS|TS|TS d|0~~1023|
654 |TC|TC|TC d|0~~1023|
655 |STS|STS|STS d|0~~1023|
656 |STC|STC|STS d|0~~1023|
657 |CS|CS|CS d|0~~1023|
658 |CC|CC|CC d|0~~1023|
659 |SM|SM|SM d|0~~9999|
660 |L|L|L d|0~~32767|
661 |S|S|S d|0~~4095|
662 |(% rowspan="9" %)Word|W|W|W h|0~~3FF|
663 |TN|TN|TN d|0~~1023|
664 |STN|STN|STN d|0~~1023|
665 |CN|CN|CN d|0~~1023|
666 |R|R|R d|0~~32767|
667 |SW|SW|SW h|0~~7FFF|
668 |Z|Z|Z d|0~~23|
669 |D|D|D d|0~~7999|
670 |SD|SD|SD d|0~~11999|
671
672 **PLC Settings (GX Works 3)**
673
674 Create a blank FX5U project
675
676 Find the 485 serial port module in the system navigation bar and double click to enter the settings.
677
678 (% style="text-align:center" %)
679 [[image:12.PLC Protocol_html_5c9cb13fac1e6c93.png||data-xwiki-image-style-alignment="center" height="462" width="200" class="img-thumbnail"]]
680
681 Select protocol in the setting item, and set parameters.
682
683 (% style="text-align:center" %)
684 [[image:12.PLC Protocol_html_de942589ca070228.png||data-xwiki-image-style-alignment="center" height="324" width="600" class="img-thumbnail"]]
685
686 Set station number, and [Message Pattern] (Pattern 1 or Pattern 4)
687
688 (% style="text-align:center" %)
689 [[image:12.PLC Protocol_html_387ec7d00b5feb59.png||data-xwiki-image-style-alignment="center" height="323" width="600" class="img-thumbnail"]]
690
691 Click the [Apply] button to finish the setting.
692
693 Click download and select the items as below, then click [execute] to download the configuration to PLC.
694
695 (% style="text-align:center" %)
696 [[image:12.PLC Protocol_html_cdef1c5ec8cc2105.png||data-xwiki-image-style-alignment="center" height="434" width="600" class="img-thumbnail"]]
697
698 As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection].
699
700 Done.
701
702 **Cable Wiring**
703
704 * **RS485**
705
706 (% style="text-align:center" %)
707 [[image:12.PLC Protocol_html_d4012bdeb4ce4aae.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
708
709 (% style="text-align:center" %)
710 [[image:12.PLC Protocol_html_4bf57ad8d44eacc4.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
711
712 * **RS422**
713
714 (% style="text-align:center" %)
715 [[image:12.PLC Protocol_html_f8a6bebc5792960d.png||data-xwiki-image-style-alignment="center" height="253" width="402" class="img-thumbnail"]]
716
717 **✎Note:** COM3 only available in PI8000/PI9000 series.
718
719 == **L02 MELSEC (Ethernet)** ==
720
721 Mitsubishi Q series CPU built-in Ethernet port.
722
723 **HMI Settings**
724
725 (% class="table-bordered" %)
726 |**Items**|**Settings**|**Note**
727 |Protocol|MIT L02 CPU MELSEC|
728 |Connection|Ethernet|
729 |Port No.|1025|Must be the same as the PLC setting
730 |PLC station No.|0|Must be the same as the PLC setting
731
732 **Address List**
733
734 (% class="table-bordered" %)
735 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
736 |Bit|X|X|X h|0~~FFFF|
737 |Bit|Y|Y|Y h|0~~FFFF|
738 |Bit|M|M|M d|0~~9999|
739 |Bit|L|L|L d|0~~9999|
740 |Bit|F|F|F d|0~~9999|
741 |Bit|B|B|B h|0~~FFFF|
742 |Bit|V|V|V d|0~~2047|
743 |Bit|TC|TC|TC d|0~~9999|
744 |Bit|SS|SS|SS d|0~~9999|
745 |Bit|SC|SC|SC d|0~~9999|
746 |Bit|CS|CS|CS d|0~~9999|
747 |Bit|CC|CC|CC d|0~~9999|
748 |Bit|SB|SB|SB h|0~~FFFF|
749 |Bit|SM|SM|SM d|0~~2047|
750 |Bit|STS|STS|STS d|0~~1023|
751 |Bit|S|S|S d|0~~9999|
752 |Bit|DX|DX|DX h|0~~FFFF|
753 |Bit|DY|DY|DY h|0~~FFFF|
754 |Bit|TS|TS|TS d|0~~9999|
755 |Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
756 |Word|W|W|W h|0~~FFFF|
757 |Word|TN|TN|TN d|0~~99999|
758 |Word|SN|SN|SN d|0~~99999|
759 |Word|CN|CN|CN d|0~~99999|
760 |Word|R|R|R d|0~~99999|
761 |Word|SW|SW|SW h|0~~FFFF|
762 |Word|Z|Z|Z d|0~~99999|
763 |Word|ZR|ZR|ZR h|0~~FFFF|
764 |Word|D|D|D d|0~~99999|
765
766 **Communication Settings**
767
768 Enable HMI Ethernet in [Project Settings];
769
770 (% id="cke_bm_7504S" style="display:none" %) [[image:12.PLC Protocol_html_43b671f18153910d.png||height="107" width="405"]]
771
772 Set PLC IP in [Device IP] settings;
773
774 (% style="text-align:center" %)
775 [[image:12.PLC Protocol_html_38189fae42f6caa7.png||data-xwiki-image-style-alignment="center" height="206" width="600" class="img-thumbnail"]]
776
777 **PLC Settings (GX Works2 )**
778
779 Create a project
780
781 Set PLC IP, subnet mask and gateway;
782
783 Select [Binary Code] as communication data code;
784
785 (% style="text-align:center" %)
786 [[image:12.PLC Protocol_html_776e17505f3fc6c0.png||data-xwiki-image-style-alignment="center" height="524" width="600" class="img-thumbnail"]]
787
788 Set PLC port number, for example 1025
789
790 (% style="text-align:center" %)
791 [[image:12.PLC Protocol_html_8d0d1a22d388f70b.png||data-xwiki-image-style-alignment="center" height="524" width="600" class="img-thumbnail"]]
792
793 Save settings;
794
795 Download project into PLC device;
796
797 Restart PLC device;
798
799 **Cable Wiring**
800
801 (% style="text-align:center" %)
802 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
803
804 == **QJ71E71 MELSEC** ==
805
806 Mitsubishi QJ71E71 Ethernet communication module;
807
808 **HMI Settings**
809
810 (% class="table-bordered" %)
811 |**Items**|**Settings**|**Note**
812 |Protocol|MIT QJ71E71 MELSEC|
813 |Connection|Ethernet|
814 |Port No.|1025|Must be the same as the PLC setting
815 |PLC station No.|0|Must be the same as the PLC setting
816
817 **Address List**
818
819 (% class="table-bordered" %)
820 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
821 |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
822 |Y|Y|Y h|0~~1FFF|
823 |M|M|M d|0~~99999|
824 |L|L|L d|0~~8191|
825 |F|F|F d|0~~2047|
826 |B|B|B h|0~~1FFF|
827 |V|V|V d|0~~2047|
828 |TS|TS|TS d|0~~2047|
829 |TC|TC|TC d|0~~2047|
830 |SS|SS|SS d|0~~2047|
831 |SC|SC|SC d|0~~2047|
832 |CS|CS|CS d|0~~1023|
833 |CC|CC|CC d|0~~1023|
834 |SB|SB|SB h|0~~7FF|
835 |S|S|S d|0~~8191|
836 |DX|DX|DX h|0~~1FFF|
837 |DY|DY|DY h|0~~1FFF|
838 |SM|SM|SM d|8000~~9999|
839 |(% rowspan="10" %)Word|SD|SD|SD d|0~~2047|
840 |D|D|D d|0~~12287|
841 |W|W|W h|0~~1FFF|
842 |TN|TN|TN d|0~~2047|
843 |SN|SN|SN d|0~~2047|
844 |CN|CN|CN d|0~~1023|
845 |R|R|R d|0~~32767|
846 |SW|SW|SW h|0~~7FF|
847 |Z|Z|Z d|0~~15|
848 |ZR|ZR|ZR h|0~~FE7FF|
849
850 **HMI Communication Settings**
851
852 1) Enable HMI Ethernet in [Project Settings];
853
854 (% id="cke_bm_7537S" style="display:none" %) [[image:12.PLC Protocol_html_43b671f18153910d.png||height="107" width="405"]]
855
856 2) Set PLC IP in [Device IP] settings;
857
858 (% style="text-align:center" %)
859 [[image:12.PLC Protocol_html_2d566cb5ffb2618c.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
860
861 **PLC Settings(GX Works2)**
862
863 * Click [Ethernet/CC IE/MELSECNET];
864 * Please select [Ethernet] as network type;
865 * Set station I/O number according to situation (For example, 0000 means that the module is connected to PLC CPU in first order);
866 * Select [Online] as Mode;(% id="cke_bm_8449S" style="display:none" %) [[image:12.PLC Protocol_html_acd084d845da380e.png||height="300" width="554"]]
867 * Click [Operation setting] to set IP;
868 * Select [Binary Code] as [Communication Data Code];(% id="cke_bm_8474S" style="display:none" %) [[image:12.PLC Protocol_html_a972e671d2bb9150.png||height="304" width="553"]]
869 * Set protocol: TCP;
870 * Set [unpassive] in [Open system];
871 * Set [receive] in [Fixed buffer];
872 * Set [procedure Exist] in [Fixed buffer communication];
873 * Disable [Pairing open];
874 * Set [No confirm] in [Existence confirmation];
875 * Host station port number: 1025;
876 * (% id="cke_bm_8547S" style="display:none" %) [[image:12.PLC Protocol_html_f2c432006cdd2f9.png||height="220" width="553"]](%%)Save settings;
877 * Download project into PLC and restart it
878
879 **Cable Wiring**
880
881 (% style="text-align:center" %)
882 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
883
884 = **MODBUS** =
885
886 == **MODBUS RTU Master** ==
887
888 Supported Series: MODBUS RTU CONTROLLER
889
890 HMI works as MODBUS SLAVE connecting with MASTER
891
892 (% style="text-align:center" %)
893 [[image:12.PLC Protocol_html_44425b313b0a6b96.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]
894
895
896 (% style="text-align:center" %)
897 [[image:12.PLC Protocol_html_b56b9da32c3caaa.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
898
899
900 (% style="text-align:center" %)
901 [[image:12.PLC Protocol_html_67cd25458b9c72a6.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
902
903 **HMI Settings**
904
905 (% class="table-bordered" %)
906 |**Items**|**Settings**|**Note**
907 |Protocol|MODBUS RTU Master|
908 |Connection|RS485/RS232|
909 |Baud rate|2400~~187500|
910 |Data bit|8|
911 |Parity|Even/ Odd/ None|
912 |Stop bit|1/2|
913 |Station No.|0~~255|
914
915 **Address List**
916
917 (% class="table-bordered" %)
918 |**Type**|**HMI address**|**MODBUS code**|**Range**
919 |Bit|HDX3000.0~~HDX3499.15|0|0~~7999
920 |Word|HDW3500~~HDW7999|4|0~~4499
921
922 **Cable Wiring**
923
924 * **RS485**
925
926 (% style="text-align:center" %)
927 [[image:12.PLC Protocol_html_68dfb6d383f0edd9.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
928
929 (% style="text-align:center" %)
930 [[image:12.PLC Protocol_html_cbeb90cb4faaa8bc.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
931
932 * **RS232**
933
934 (% style="text-align:center" %)
935 [[image:12.PLC Protocol_html_9030ba679545793b.png||data-xwiki-image-style-alignment="center" height="241" width="387" class="img-thumbnail"]]
936
937 **✎Note:** COM3 only available in PI8000/PI9000 series.
938
939 == **MODBUS RTU Slave (All function)/(All function OneBaseAddress)** ==
940
941 Supported Series: MODBUS RTU CONTROLLER
942
943 HMI works as MODBUS MASTER connecting with SLAVE.
944
945 The addresses in [All function] start from 0, while the addresses in [All function OneBaseAddress] start from 1 (offset 1).
946
947 (% style="text-align:center" %)
948 [[image:12.PLC Protocol_html_7236139c887defad.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]
949
950
951 (% style="text-align:center" %)
952 [[image:12.PLC Protocol_html_de80207f2b495c17.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
953
954
955 (% style="text-align:center" %)
956 [[image:12.PLC Protocol_html_4e9e8eff81c7ff8b.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
957
958 **HMI Settings**
959
960 (% class="table-bordered" %)
961 |**Items**|**Settings**|**Note**
962 |Protocol|MODBUS RTU Slave (All function)/( All function OneBaseAddress)|
963 |Connection|RS485/RS232|
964 |Baud rate|2400~~187500|
965 |Data bit|8|
966 |Parity|Even/ Odd/ None|
967 |Stop bit|1/2|
968 |PLC station No.|0~~255|
969
970 **Address List**
971
972 (% class="table-bordered" %)
973 |**Type**|**Address Type**|**Function code & Description**
974 |(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
975 |06 (write single register: write a binary value to a holding register)
976 |10 (write values to multiple addresses )
977 |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
978 |06 (write single register: write a binary value to a holding register)
979 |10 (write values to multiple addresses )
980 |(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
981 |06 (write single register: write a binary value to a holding register)
982 |10 (write values to multiple addresses )
983 |(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
984 |10 (write values to multiple addresses )
985 |(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
986 |05 (Force a single coil to force the on/off state of a logic coil)
987 |0F (Write multiple bits, ie write continuously)
988 |(% rowspan="3" %)1|02 (Read the input state)
989 |05 (Force a single coil to force the on/off state of a logic coil)
990 |0F (Write multiple bits)
991 |(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
992 |05 (Force a single coil to force the on/off state of a logic coil)
993 |0F (Write multiple bits)
994 |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
995 |0F (Write multiple bits)
996
997 **✎Note:**
998
999 * Modbus can also support getting bit from the word, which could access the address such as 100.1 and other formats.
1000 * The function codes sent out are the same as those that read and write words.
1001
1002 **Station number for more than one slaves**
1003
1004 If there are more than one slaves connected to HMI, please set slave station number during editing address, as below shows.
1005
1006 (% style="text-align:center" %)
1007 [[image:12.PLC Protocol_html_31f028c6d80be344.png||data-xwiki-image-style-alignment="center" height="515" width="485" class="img-thumbnail"]]
1008
1009 **Cable Wiring**
1010
1011 * **RS485**
1012
1013 (% style="text-align:center" %)
1014 [[image:12.PLC Protocol_html_68dfb6d383f0edd9.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1015
1016 (% style="text-align:center" %)
1017 [[image:12.PLC Protocol_html_cbeb90cb4faaa8bc.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1018
1019 * **RS232**
1020
1021 (% style="text-align:center" %)
1022 [[image:12.PLC Protocol_html_9030ba679545793b.png||data-xwiki-image-style-alignment="center" height="241" width="387" class="img-thumbnail"]]
1023
1024 **✎Note:** COM3 only available in PI8000/PI9000 series.
1025
1026 == **MODBUS TCP Slave (All function)** ==
1027
1028 Supported series: MODBUS TCP controller
1029
1030 HMI works as MODBUS TCP MASTER connecting with TCP SLAVE
1031
1032 (% style="text-align:center" %)
1033 [[image:12.PLC Protocol_html_8877cb7f39c2b607.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]
1034
1035 (% style="text-align:center" %)
1036 [[image:12.PLC Protocol_html_e7e1f06f127a9175.png||data-xwiki-image-style-alignment="center" height="426" width="553" class="img-thumbnail"]]
1037
1038
1039 (% style="text-align:center" %)
1040 [[image:12.PLC Protocol_html_60bbfe5de79417a6.png||data-xwiki-image-style-alignment="center" height="163" width="553" class="img-thumbnail"]]
1041
1042 **HMI Setting**
1043
1044 (% class="table-bordered" %)
1045 |**Items**|**Settings**|**Note**
1046 |Protocol|MODBUS TCP Slave (All function)|
1047 |Connection|Ethernet|
1048 |Port No.|502|
1049 |PLC station No.|1|
1050
1051 **Address List**
1052
1053 (% class="table-bordered" %)
1054 |**Type**|**Register**|**Function code & Description**
1055 |(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1056 |06 (write single register: write a binary value to a holding register)
1057 |10 (write values to multiple addresses )
1058 |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
1059 |06 (write single register: write a binary value to a holding register)
1060 |10 (write values to multiple addresses )
1061 |(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
1062 |06 (write single register: write a binary value to a holding register)
1063 |10 (write values to multiple addresses )
1064 |(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
1065 |10 (write values to multiple addresses )
1066 |(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
1067 |05 (Force a single coil to force the on/off state of a logic coil)
1068 |0F (Write multiple bits, ie write continuously)
1069 |(% rowspan="3" %)1|02 (Read the input state)
1070 |05 (Force a single coil to force the on/off state of a logic coil)
1071 |0F (Write multiple bits)
1072 |(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
1073 |05 (Force a single coil to force the on/off state of a logic coil)
1074 |0F (Write multiple bits)
1075 |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1076 |0F (Write multiple bits)
1077
1078 **Communication Settings**
1079
1080 Enable HMI Ethernet in [Project Settings];
1081
1082 (% style="text-align:center" %)
1083 [[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1084
1085 Set PLC IP in [Device IP] settings;
1086
1087 (% style="text-align:center" %)
1088 [[image:12.PLC Protocol_html_4bd3cc8348adecf8.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
1089
1090 **Cable Wiring**
1091
1092 (% style="text-align:center" %)
1093 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1094
1095 = **Omron** =
1096
1097 == **EC55** ==
1098
1099 Supported device: EC55 temperature instrument
1100
1101 **HMI Settings**
1102
1103 (% class="table-bordered" %)
1104 |**Items**|**Settings**|**Note**
1105 |Protocol|Omron EC55|
1106 |Connection|RS485 (9600, 2, 7, EVEN)|
1107 |Port No.|None|
1108 |PLC station No.|0|
1109
1110 **Address List**
1111
1112 (% class="table-bordered" %)
1113 |**Type**|**Register**|**Device range**|**HMI range**|**Function**
1114 |(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0
1115 |C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0
1116 |C3|0-CD(Hex)|0-205|Set Read/Write parameter for area 1
1117 |(% rowspan="6" %)Word|80|0-13(Hex)|0-19|Set read only parameter in area 0
1118 |81|0-4D(Hex)|0-77|Set Read/Write parameter in area 0
1119 |83|0-CD(Hex)|0-205|Set Read/Write parameter in area 1
1120 |CP|-|0-6|Read controller intrinsic property
1121 |CS|-|0-2|Read controller states
1122 |CA|-|0-17|Action command
1123
1124 **Device Settings**
1125
1126 Omron E5CC PLC configuration
1127
1128 After entering the Communication Settings menu, please set the parameters to the default values for the following table. Press the cycle key of the instrument to enter the next setting.
1129
1130 (% style="text-align:center" %)
1131 [[image:12.PLC Protocol_html_3d95e093792ba98a.png||data-xwiki-image-style-alignment="center" height="229" width="550" class="img-thumbnail"]]
1132
1133 According to PLC configuration and communication port configuration information of the HMI, provide the corresponding steps and configuration screenshots. This configuration needs to communicate properly with the above PLC configuration. The project settings are as follows
1134
1135 (% style="text-align:center" %)
1136 [[image:12.PLC Protocol_html_be583aa69dd6cf4c.png||data-xwiki-image-style-alignment="center" height="242" width="550" class="img-thumbnail"]]
1137
1138 **✎Note:** The communication settings for HMI should be consistent with this setting.
1139
1140 **Cable Wiring**
1141
1142 (% style="text-align:center" %)
1143 [[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]]
1144
1145 (% style="text-align:center" %)
1146 [[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
1147
1148 **✎Note:**
1149
1150 * COM3 only available in PI8000/PI9000 series.
1151 * CA address could not support continuous writing function;
1152 * Because of CP address intrinsic property: read control intrinsic property, so please place the character input part in use. Set address with CP0 and character length 10, used to display controller type. And place a number input part, set address with CP5 (cache size). Do not place other CP type address without CP0 in screen, otherwise CP type address is invalid
1153 * When set value into read & write address, it is necessary to switch the temperature instrument meter to the corresponding interface according to the menu of the instrument where the address locates, so that the value could be written, otherwise, the value could not be written; When the communication write setting of the instrument is turned off, the writing function is invalid. Writing function could be opened by using the 00 address of the CA register, which write 01 value.
1154 * When continuous writing of a value to a read-write address, please make sure all continuous writing address could be written. Otherwise, if one of these addresses could not be written, then all continuous writing commands will fail.
1155 * Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document.
1156 * When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable.
1157 * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
1158 * (% id="cke_bm_8690S" style="display:none" %) [[image:12.PLC Protocol_html_d428cad280fdefb3.png||height="276" width="347"]](%%)Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1159
1160 == EtherNet/IP NX series ==
1161
1162 Supported series: Omron NX/NJ series
1163
1164 **HMI Setting**
1165
1166 (% class="table-bordered" %)
1167 |**Items**|**Settings**|**Note**
1168 |Protocol|Omron NX Ethernet/IP|
1169 |Connection|Ethernet|
1170 |Port No.|44818|
1171 |PLC station No.|1|
1172
1173 **Instruction**
1174
1175 1) In Sysmac Studio, please select [Publish Only] for [Network Publish] when setting address tag.
1176
1177 2) When [Do not publish] is selected for a tag, different import methods may lead to different results. When import tags by [Get Tags from Device], the tag will be eliminated. If [Import tags] is selected, the tags will be imported, but the communication will not succeed.
1178
1179 (% style="text-align:center" %)
1180 [[image:12.PLC Protocol_html_4156caf6f116c570.png||data-xwiki-image-style-alignment="center" height="277" width="600" class="img-thumbnail"]]
1181
1182 **Export labels from Sysmac Studio**
1183
1184 Launch Sysmac Studio, under Global Variables create the address labels, and thenselect [Tools] -> [Export Global Variables];
1185
1186 (% style="text-align:center" %)
1187 [[image:12.PLC Protocol_html_26f91dee66c723e9.png||data-xwiki-image-style-alignment="center" height="276" width="600" class="img-thumbnail"]]
1188
1189 Launch PIStudio, in [Communication] Settings add Omron NX Ethernet/IP protocol;
1190
1191 Click [Label manage];
1192
1193 (% style="text-align:center" %)
1194 [[image:12.PLC Protocol_html_cd38d2d0c5187f6b.png||data-xwiki-image-style-alignment="center" height="276" width="600" class="img-thumbnail"]]
1195
1196 Click [Import labels] and then select the file exported in step 1;
1197
1198 (% style="text-align:center" %)
1199 [[image:12.PLC Protocol_html_52bd5da678bef9b4.png||data-xwiki-image-style-alignment="center" height="403" width="600" class="img-thumbnail"]]
1200
1201 The Import Status field shows the result, click [OK] to finish importing address labels;
1202
1203 (% style="text-align:center" %)
1204 [[image:12.PLC Protocol_html_7f0465a589b98912.png||data-xwiki-image-style-alignment="center" height="291" width="600" class="img-thumbnail"]]
1205
1206 **Communication Settings**
1207
1208 Enable HMI Ethernet in [Project Settings];
1209
1210 (% style="text-align:center" %)
1211 [[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1212
1213 Set PLC IP in [Device IP] settings;
1214
1215 (% style="text-align:center" %)
1216 [[image:12.PLC Protocol_html_437cb087b36b5784.png||data-xwiki-image-style-alignment="center" height="330" width="600" class="img-thumbnail"]]
1217
1218
1219 (% style="text-align:center" %)
1220 [[image:12.PLC Protocol_html_60ef71528a99abf5.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]]
1221
1222 **Cable Wiring**
1223
1224 (% style="text-align:center" %)
1225 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1226
1227 = **OpenCAN** =
1228
1229 OpenCan is based on CAN2.0 standard; OpenCAN protocols that could be configured autonomously to accept and send frames.
1230
1231 This protocol is only available in PI8000 series HMI.
1232
1233 **HMI Settings**
1234
1235 (% class="table-bordered" %)
1236 |**Items**|**Settings**|**Note**
1237 |Protocol|OPENCAN|
1238 |Connection|CAN port|
1239 |Baud rate|250000|
1240
1241 **CAN frame setting in HMI**
1242
1243 Click [OpenCAN setting] button in communication setting window;
1244
1245 (% style="text-align:center" %)
1246 [[image:12.PLC Protocol_html_e866b9e56e19785d.png||data-xwiki-image-style-alignment="center" height="503" width="600" class="img-thumbnail"]]
1247
1248 Click [Add] to create a new frame;
1249
1250 (% style="text-align:center" %)
1251 [[image:12.PLC Protocol_html_3a6f4e2141763c8f.png||data-xwiki-image-style-alignment="center" height="315" width="600" class="img-thumbnail"]]
1252
1253 (% class="table-bordered" %)
1254 |**No**|**Items**|**Description**
1255 |1|Add|add a frame related to register address
1256 |2|Insert|Select the position where you want to insert a frame, and click [Insert frame] to add a new frame in front of the current frame position
1257 |3|Frame manager|This list shows some of the main parameters for each frame that the user adds
1258 |4|Modify|Modify the frames in frame management
1259 |5|Copy|Copy one frame to another
1260 |6|Delete|Remove the selected frames from the list by modifying the frames in frame management. If no frames are selected in the list, the first frame is deleted.
1261 |7|Empty|All frames in the list are cleared
1262 |8|Browse|Displays configuration files in XML format in IE
1263 |9|OK|Complete the configuration of the frame and exit
1264
1265 Set CANBUS frame in setting windows
1266
1267 (% style="text-align:center" %)
1268 [[image:12.PLC Protocol_html_7c83130820321ef.png||data-xwiki-image-style-alignment="center" height="507" width="600" class="img-thumbnail"]]
1269
1270 (% class="table-bordered" %)
1271 |**No**|(% style="width:185px" %)**Items**|(% style="width:854px" %)**Description**
1272 |1|(% style="width:185px" %)ID|(% style="width:854px" %)Set the ID of a can frame in hexadecimal format;
1273 |2|(% style="width:185px" %)ID assign|(% style="width:854px" %)split the ID by PF, PS, and SA;
1274 |3|(% style="width:185px" %)Frame type|(% style="width:854px" %)Select Standard frame or Extended Frame;
1275 |4|(% style="width:185px" %)Frame format|(% style="width:854px" %)Select between data frame and remote Frame;
1276 |5|(% style="width:185px" %)Data|(% style="width:854px" %)Set the data part of CAN frame, with two Numbers representing a hexadecimal number and Spaces spaced; Maximum support of 8 bytes is defined according to CAN message;
1277 |6|(% style="width:185px" %)Use address|(% style="width:854px" %)(((
1278 Set the register address related to the CAN frame, which corresponds to the register address set on the main state one by one. The data obtained from the address is assigned continuously;
1279
1280 **Edit:** Set a bit or word address by its format;
1281
1282 **Option: **Set address options related to frame, enter “register address option” interface, specifically browse the following “register address option” interface;
1283 )))
1284 |(% rowspan="8" %)7|(% rowspan="8" style="width:185px" %)Data interactive configuration|(% style="width:854px" %)There are two interactive modes of the touch screen. One is that the touch screen actively sends frames, and the device receives and processes and feeds back. The other, on the contrary, passively receives frames from the device for processing and feedback;
1285 |(% style="width:854px" %)Send after receiving: if this item is selected, the interaction of the touch screen will act as a passive party, and the touch screen will receive the CAN frame first and send feedback. Unchecked items interact in the opposite way;
1286 |(% style="width:854px" %)Feedback mode: feedback mode includes no response, confirm response and data response;
1287 |(% style="width:854px" %)No response: the device or touch screen will not receive feedback;
1288 |(% style="width:854px" %)Confirm response: the device or the touch screen will receive feedback with confirmation, which could be used to compare the data parts. If this function is used, the 20 addresses before and after this address should not be used. All addresses of cata10-cata30 could not be used with the reply confirmation function of cata20;
1289 |(% style="width:854px" %)Data response: the device or touch screen will receive feedback with data, and the data to be separated from the feedback frame should be set to store in the register address;
1290 |(% style="width:854px" %)response ID: if the address wants to receive data on a frame with a different ID, set this, check "different from sender", and enter a different ID in the following input box. Without this setting, the screen will receive and process a frame with the same ID as the sender;
1291 |(% style="width:854px" %)Response timeout: sets whether the response frame timeout;
1292 |(% rowspan="3" %)8|(% rowspan="3" style="width:185px" %)Control address|(% style="width:854px" %)If ticked, enable sending when the value of the corresponding control bit number (address) is non-0.
1293 |(% style="width:854px" %)Control bit: CtrlBit register range 0~~255, if the control bit is ON, can instruction will run normally. Otherwise, it doesn't run;
1294 |(% style="width:854px" %)Manually send: a manually send tick indicates only one send;
1295 |9|(% style="width:185px" %)Flag configuration|(% style="width:854px" %)Communication control for each frame. Display OFF when communication is normal, and ON when communication is abnormal;
1296 |10|(% style="width:185px" %)Note|(% style="width:854px" %)Fill the text to explain the meaning of the frame;
1297 |11|(% style="width:185px" %)Data assign|(% style="width:854px" %)Preview the display in this table based on the address and the corresponding number of digits;
1298 |12|(% style="width:185px" %)Current operation display|(% style="width:854px" %)Display the description of current operation;
1299 |13|(% style="width:185px" %)Add|(% style="width:854px" %)Add a new frame;
1300 |14|(% style="width:185px" %)Save frame|(% style="width:854px" %)Save the configured frame format;
1301 |15|(% style="width:185px" %)Cancel|(% style="width:854px" %)Cancel the frame configuration;
1302
1303 Set CAN address (Read or write operation);
1304
1305 (% style="text-align:center" %)
1306 [[image:12.PLC Protocol_html_7e9f9b25eb6ae8ce.png||data-xwiki-image-style-alignment="center" height="446" width="600" class="img-thumbnail"]]
1307
1308 (% class="table-bordered" %)
1309 |**No.**|(% style="width:207px" %)**Item**|(% style="width:829px" %)**Description**
1310 |1|(% style="width:207px" %)Current address|(% style="width:829px" %)Displays the register type and register address set by the user in the data access interface
1311 |(% rowspan="3" %)2|(% rowspan="3" style="width:207px" %)Trigger|(% style="width:829px" %)Two operations, "read" and "write," are based on on-screen registers
1312 |(% style="width:829px" %)If "read" is selected, the register address is reading device data in a manner of sending frames set by the user in a loop.
1313 |(% style="width:829px" %)If "write" is selected, the screen data of the register address will be written into the device. The writing mode is that the user makes a write operation on the screen, which will trigger the sending of a frame set by the user.
1314 |(% rowspan="5" %)3|(% rowspan="3" style="width:207px" %)Data operation|(% style="width:829px" %)The read and write operations in the trigger conditions are set accordingly.
1315 |(% style="width:829px" %)If the trigger condition is a read operation, this section needs to set the position and length of the data to be obtained at the current address in the frame.
1316 |(% style="width:829px" %)If the trigger condition is a writing operation, there are two situations:(((
1317 * If the "add writing data to the frame" option is not selected, the frame set by the user will be sent directly when the user writes on the screen.
1318 * Select the "add the written data to the frame" option, and when the user writes on the screen, the program will insert the data in the frame set by the user and send the written data to the frame set by the user according to the data insertion position and length set by the user.
1319 )))
1320 |(% rowspan="2" style="width:207px" %)Position and length input format|(% style="width:829px" %)If the register type is a bit address, the decimal point is required to represent the bits in the byte. For example, 1.1 represents the first bit of the first byte of 8 bytes in the data frame, and the length is in bits, and so on.
1321 |(% style="width:829px" %)If the register type is word address, the integer only needs to represent the byte, such as 1, which represents the first byte of 8-byte data in the data frame, and the unit of length is byte, and so on.
1322 |4|(% style="width:207px" %)Add|(% style="width:829px" %)Add current configuration
1323 |5|(% style="width:207px" %)Close|(% style="width:829px" %)Close the configuration window to exit
1324
1325 **Multiple Packages Settings**
1326
1327 (% style="text-align:center" %)
1328 [[image:12.PLC Protocol_html_107e0f6b1a90afff.png||data-xwiki-image-style-alignment="center" height="341" width="600" class="img-thumbnail"]]
1329
1330 Check [Multiple packages supported] to open [Multiple package data] window, as below show.
1331
1332 Select Multiple package type
1333
1334 * Not Multiple packages
1335 * J1939 Multiple packages
1336 * Customized Multiple packages
1337
1338 Click [Edit Receive data] for [Receive] settings
1339
1340 * Start code+ Total length (J1939)
1341
1342 (% style="text-align:center" %)
1343 [[image:12.PLC Protocol_html_3c360c6b5aca51bf.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]]
1344
1345 As set above set, J1939 command is received by the HMI, only when its length is 25 bytes, and the start code is 0x57, 0x1B;
1346
1347 * Start code + Data max length (J1939)
1348
1349 (% style="text-align:center" %)
1350 [[image:12.PLC Protocol_html_74496b2a68cfcdde.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]]
1351
1352 As set above set, J1939 command is received by the HMI, only when its length less than 50 bytes, and the start code is 0x57, 0x1B;
1353
1354 * Data max length (J1939)
1355
1356 (% style="text-align:center" %)
1357 [[image:12.PLC Protocol_html_98cea3e7cbd8f05d.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]]
1358
1359 As set above set, J1939 command is received by the HMI, only when its length less than 50 bytes.
1360
1361 * Customized multiple package
1362
1363 (% style="text-align:center" %)
1364 [[image:12.PLC Protocol_html_4635bbe4d7999db0.png||data-xwiki-image-style-alignment="center" height="395" width="367" class="img-thumbnail"]]
1365
1366 As set above, It is received by the HMI, when the first frame starts with 0X57 0X1B, and the sum of the data lengths of multiple frames is equal to 79 bytes.
1367
1368 Click [Edit Send data] for [Send] setting
1369
1370 * J1939
1371
1372 (% style="text-align:center" %)
1373 [[image:12.PLC Protocol_html_a4769e44331ca732.png||data-xwiki-image-style-alignment="center" height="280" width="463" class="img-thumbnail"]]
1374
1375 [Data] is all data to be sent.
1376
1377 Since the frame of the J1939 frame contains the number of the data packet, so the data sent is: the first byte (number) + 7 bytes of data. If it is less than 7 bytes, it is sent in the actual number of bytes.
1378
1379 * Customized multiple package
1380
1381 (% style="text-align:center" %)
1382 [[image:12.PLC Protocol_html_78546f765d6f3deb.png||data-xwiki-image-style-alignment="center" height="280" width="463"]]
1383
1384 [Data] is all data to be sent.
1385
1386 As set above, fist frame length is 2 bytes, and others are sent with 6 bytes for every frame, if the last frame is less than 6 bytes, send according to the actual length.
1387
1388 **Cable Wiring**
1389
1390 (% style="text-align:center" %)
1391 [[image:12.PLC Protocol_html_fccede84efcbdc22.png||data-xwiki-image-style-alignment="center" height="111" width="391" class="img-thumbnail"]]
1392
1393 **✎Note:** The address interval between each frame need to be more than a word address;
1394
1395 = **SHIMADEN** =
1396
1397 == **FP23** ==
1398
1399 Supported series: SHIMADEN FP23 series
1400
1401 **HMI Setting**
1402
1403 (% class="table-bordered" %)
1404 |**Items**|**Settings**|**Note**
1405 |Protocol|SHIMADEN FP23 series|
1406 |Connection|RS485 (9600, 1, 7, EVEN)|
1407 |Port No.|None|
1408 |PLC station No.|0|
1409
1410 **Address List**
1411
1412 (% class="table-bordered" %)
1413 |**Device address**|**HMI register**|**Address range**|**Type**
1414 |0040-0043(HEX)|FP040|100064-200067|Read only
1415 |0100-010B(HEX)|FP100|100256-200267|Read only
1416 |0110-0142(HEX)|FP110|100272-200322|Read only
1417 |0182-0252(HEX)|FP182|100386-200594|Write only
1418 |0280-0281(HEX)|FP280|100640-200641|Read only
1419 |0300-030B(HEX)|FP300|100768-200779|Read and write
1420 |0380-039F(HEX)|FP380|100896-200927|Read and write
1421 |0400-04D7(HEX)|FP400|101024-201239|Read and write
1422 |0500-05B0(HEX)|FP500|101280-201456|Read and write
1423 |0600-0670(HEX)|FP600|101536-201814|Read and write
1424 |0720-0738(HEX)|FP720|101824-201848|Read and write
1425 |0800-083F(HEX)|FP800|102048-202111|Read and write
1426 |0900-0952(HEX)|FP900|102304-202386|Read and write
1427 | |Ctrl|0-2|
1428
1429 **✎Note:**
1430
1431 * The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
1432 * The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in FP23;
1433 * The Ctrl register is used to store the control group number and BCC check mode.
1434
1435 **Ctrl Register Description**
1436
1437 * The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
1438 * Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR .
1439 * Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
1440 * Ctrl3 reserved
1441
1442 **✎Note:**
1443
1444 After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
1445
1446 **Cable Wiring**
1447
1448 (% style="text-align:center" %)
1449 [[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]]
1450
1451 (% style="text-align:center" %)
1452 [[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
1453
1454 **✎Note:** COM3 only available in PI8000/PI9000 series.
1455
1456 == **{{id name="_Toc23422"/}}SR90** ==
1457
1458 Supported series: SHIMADEN SR90 series
1459
1460 **HMI Setting**
1461
1462 (% class="table-bordered" %)
1463 |**Items**|**Settings**|**Note**
1464 |Protocol|SHIMADEN SR90 protocol|
1465 |Connection|RS485 (1200, 1, 7, EVEN)|
1466 |Port No.|None|
1467 |PLC station No.|0|
1468
1469 **Address List**
1470
1471 (% class="table-bordered" %)
1472 |**Device address**|**HMI register**|**Address range**|**Type**
1473 |0040-0043 (HEX)|SR040|100064-100067|Read only
1474 |0100-010A(HEX)|SR0100|100256-100266|Read only
1475 |0182-018C(HEX)|SR0182|100386-100396|Write only
1476 |0300-04FE(HEX)|SR0300|100768-101278|Write/read
1477 |0500-050B(HEX)|SR0500|101280-101291|Write/read
1478 |0590-0611(HEX)|SR0590|101424-101553|Write/read
1479 |0701-0709(HEX)|SR0701|101793-101801|Write/read
1480 | |Ctrl|0-2|~-~-
1481
1482 **✎Note:**
1483
1484 * The upper 2 bits of the address of HMIs are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
1485 * The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in SR90;
1486 * The Ctrl register is used to store the control group number and BCC check mode. See how to use it below;
1487
1488 **Ctrl Register Description**
1489
1490 * The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
1491 * Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR .
1492 * Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
1493 * Ctrl3 reserved
1494
1495 **✎Note:**
1496
1497 After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
1498
1499 **Cable Wiring**
1500
1501 (% style="text-align:center" %)
1502 [[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]]
1503
1504 (% style="text-align:center" %)
1505 [[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
1506
1507 **✎Note:** COM3 only available in PI8000/PI9000 series.
1508
1509 == **{{id name="_Toc22635"/}}MR13 series(standard protocol)** ==
1510
1511 Supported series: SHIMADEN MR13 series
1512
1513 **HMI Setting**
1514
1515 (% class="table-bordered" %)
1516 |**Items**|**Settings**|**Note**
1517 |Protocol|SHIMADEN standard protocol|
1518 |Connection|RS485 (1200, 1, 7, EVEN)|
1519 |Port No.|None|
1520 |PLC station No.|0|
1521
1522 **Address List**
1523
1524 (% class="table-bordered" %)
1525 |**Device address**|**HMI register**|**Address range**|**Type**
1526 |0100-010B(HEX)|MR100|100256-300267|Read only
1527 |0111-0126(HEX)|MR111|100273-300294|Read only
1528 |0184-0192(HEX)|MR184|100388-300402|Write only
1529 |0280-0282(HEX)|MR280|100640-300642|Read only
1530 |0300-030B(HEX)|MR300|100768-300779|Read/write
1531 |0314-0317(HEX)|MR314|100788-300791|Read/write
1532 |031A(HEX)|MR31A|100794-300794|Read/write
1533 |0320-0321(HEX)|MR320|100800-300801|Read/write
1534 |0400-0504(HEX)|MR400|101024-301284|Read/write
1535 |0506(HEX)|MR506|101286-301286|Read/write
1536 |0510-0514(HEX)|MR510|101296-301300|Read/write
1537 |0516-0524(HEX)|MR516|101302-301316|Read/write
1538 |0526(HEX)|MR526|101318-301318|Read/write
1539 |0580-08C3(HEX)|MR580|101408-302243|Read/write
1540 |~-~-|Ctrl|0-2|~-~-
1541
1542 **✎Note:**
1543
1544 * The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
1545 * The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in MR13;
1546 * The Ctrl register is used to store the control group number and BCC check mode.
1547
1548 **Ctrl Register Description**
1549
1550 * The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
1551 * Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR, STX_ETX_CR LF and @_:_CR .
1552 * Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
1553 * Ctrl3 reserved
1554
1555 **✎Note:**
1556
1557 After reloading project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
1558
1559 **Cable Wiring**
1560
1561 (% style="text-align:center" %)
1562 [[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]]
1563
1564 (% style="text-align:center" %)
1565 [[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
1566
1567 **✎Note:** COM3 only available in PI8000/PI9000 series.
1568
1569 = **Siemens** =
1570
1571 == **S7-200 Smart Ethernet** ==
1572
1573 Supported Series: Siemens S7-200 SMART Series Ethernet Module.
1574
1575 Website: [[http:~~/~~/www.siemens.com/entry/cc/en/>>url:http://www.siemens.com/entry/cc/en/]]
1576
1577 **HMI Setting**
1578
1579 (% class="table-bordered" %)
1580 |**Items**|**Settings**|**Note**
1581 |Protocol|Simens S7-200 Smart Ethernet|
1582 |Connection|Ethernet|
1583 |Port No.|102|
1584 |PLC station No.|2|
1585
1586 **Address List**
1587
1588 (% class="table-bordered" %)
1589 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
1590 |(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
1591 |Q|Q|Q ddddd.o|0.0~~99999.7|
1592 |V|VWbit|VWbit ddddd.o|0.0~~99999.7|
1593 |V|V|V ddddd.o|0.0~~99999.7|
1594 |M|M|M ddddd.o|0.0~~99999.7|
1595 |SM|SM|ddddd.o|0.0~~99999.7|
1596 |S|S|ddddd.o|0.0~~99999.7|Read only
1597 |T|T|ddddd|0~~99999|Timer state, read only
1598 |C|C|ddddd|0~~99999|Counter state, read only
1599 |(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999|
1600 |Q|QW|QW ddddd|0~~99999|
1601 |AI|AIW|AIW ddddd|0~~99999|
1602 |AQ|VB|VB ddddd|0~~99999|
1603 |V|VW|VW ddddd|0~~99998|(((
1604 VW0=VB (0~~1)
1605
1606 VW2=VB (2~~3)
1607
1608 Address value is a multiple of 2
1609 )))
1610 |V|VD|VD ddddd|0~~99998|(((
1611 VD0=VB (0~~3)
1612
1613 VD2=VB (4~~7)
1614
1615 Address value is a multiple of 4
1616 )))
1617 |M|MB|MB ddddd|0~~99999|
1618 |M|MW|MW ddddd|0~~99999|(((
1619 MW0=MB(0~~1)
1620
1621 MW2=MB(2~~3)
1622
1623 Address value is a multiple of 2
1624 )))
1625 |M|MD|MD ddddd|0~~99999|(((
1626 MD0=MB(0~~3)
1627
1628 MD4=MB(4~~7)
1629
1630 Address value is a multiple of 4
1631 )))
1632 |T|TW|TW ddddd|0~~99999|Value of timer
1633 |C|CW|CW ddddd|0~~99999|Value of counter
1634 |W|SW|SW ddddd|0~~99999|
1635
1636 **Communication Settings**
1637
1638 Enable HMI Ethernet in [Project Settings];
1639
1640 (% style="text-align:center" %)
1641 [[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1642
1643 Set PLC IP in [Device IP] settings;
1644
1645 (% style="text-align:center" %)
1646 [[image:12.PLC Protocol_html_70b0c4c2ee21b10d.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
1647
1648 * PLC IP Address: PLC IP
1649 * PLC pot No.: 102(fixed)
1650 * Network:TCP_Client_2N(fixed)
1651
1652 (% style="text-align:center" %)
1653 [[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
1654
1655 * Wait timeout: depend on actual network situation (more than 1500 ms)
1656
1657 **Cable Wiring**
1658
1659 (% style="text-align:center" %)
1660 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1661
1662 == **S7-300 Ethernet** ==
1663
1664 Supported Series: Siemens S7-300 series PLC
1665
1666 **HMI Setting**
1667
1668 (% class="table-bordered" %)
1669 |**Items**|**Settings**|**Note**
1670 |Protocol|Simens S7-300 Ethernet|
1671 |Connection|Ethernet|
1672 |Port No.|102|
1673 |PLC station No.|2|Need to be same as the PLC setting
1674
1675 **Address List**
1676
1677 (% class="table-bordered" %)
1678 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
1679 |(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
1680 |Q|Q|Q ddddd.o|0.0~~99999.7|
1681 |M|M|M ddddd.o|0.0~~99999.7|
1682 |DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
1683 nn: block number;
1684
1685 dddd: address;
1686 )))
1687 |(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
1688 |Q|QW|QW ddddd|0~~99999|
1689 |(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
1690 |MW|MW ddddd|0~~99999|(((
1691 MW0=MB(0~~1)
1692
1693 MW2=MB(2~~3)
1694
1695 Address value is a multiple of 2
1696 )))
1697 |MD|MD ddddd|0~~99999|(((
1698 MD0=MB(0~~3)
1699
1700 MD4=MB(4~~7)
1701
1702 Address value is a multiple of 4
1703 )))
1704 |(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
1705 nn: block number;
1706
1707 dddd: address
1708 )))
1709 |DBxDBW|DBxDBW nndddd|0~~99999999
1710 |DBxDBD|DBxDBD nndddd|0~~99999999
1711
1712 **Communication Settings**
1713
1714 Enable HMI Ethernet in [Project Settings];
1715
1716 (% style="text-align:center" %)
1717 [[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1718
1719 Set PLC IP in [Device IP] settings;
1720
1721 (% style="text-align:center" %)
1722 [[image:12.PLC Protocol_html_910b1a0aa9e2201c.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]]
1723
1724 * PLC IP Address: PLC IP
1725 * PLC pot No.: 102(fixed)
1726 * Network:TCP_Client_2N(fixed)
1727
1728 (% style="text-align:center" %)
1729 [[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
1730
1731 * Wait timeout: depend on actual network situation (more than 1500 ms)
1732
1733 **Cable Wiring**
1734
1735 (% style="text-align:center" %)
1736 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1737
1738 == **S7-1200 Ethernet** ==
1739
1740 Supported Series: Siemens S7-1200
1741
1742 **HMI Setting**
1743
1744 (% class="table-bordered" %)
1745 |**Items**|**Settings**|**Note**
1746 |Protocol|Siemens S7-1200|
1747 |Connection|Ethernet|
1748 |Port No.|102|
1749 |PLC station No.|2|
1750
1751 **Address List**
1752
1753 (% class="table-bordered" %)
1754 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
1755 |(% rowspan="4" %)Bit|I|I|M d.o|(((
1756 d:0~-~-9999
1757
1758 o:0-7
1759 )))|
1760 |Q|Q|Q d.o|(((
1761 d:0~-~-9999
1762
1763 o:0-7
1764 )))|
1765 |M|M|M d.o|(((
1766 d:0~-~-9999
1767
1768 o:0-7
1769 )))|
1770 |DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
1771 nn:0-9999,
1772
1773 dddd:0-9999,
1774
1775 o:0-7
1776 )))|(((
1777 nn:DB No.
1778
1779 dddd:address value
1780
1781 o: digit address
1782 )))
1783 |(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
1784 |M|MW|MW d|d:0-99999|(((
1785 MW0=MB(0~~1)
1786
1787 MW2=MB(2~~3)
1788
1789 Address value is a multiple of 2
1790 )))
1791 |M|MD|MD d|d:0-99999|(((
1792 MD0=MB(0~~3)
1793
1794 MD4=MB(4~~7)
1795
1796 Address value is a multiple of 4
1797 )))
1798 |I|IW|IW d|d:0-99999|
1799 |Q|QW|QW d|d:0-99999|
1800 |DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
1801 nn:0-9999
1802
1803 dddd:0-9999
1804 )))|(((
1805 nn:DB No.
1806
1807 dddd:address value
1808 )))
1809 |DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
1810 nn:0-9999
1811
1812 dddd:0-9999
1813 )))|(((
1814 nn:DB No.
1815
1816 dddd:address value
1817
1818 Address value is a multiple of 2
1819 )))
1820 |DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
1821 nn:0-9999
1822
1823 dddd:0-9999
1824 )))|(((
1825 nn:DB No.
1826
1827 dddd:address value
1828
1829 Address value is a multiple of 4
1830 )))
1831
1832 **Communication Settings**
1833
1834 Enable HMI Ethernet in [Project Settings];
1835
1836 (% style="text-align:center" %)
1837 [[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1838
1839 Set PLC IP in [Device IP] settings;
1840
1841 (% style="text-align:center" %)
1842 [[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
1843
1844 **✎Note:**
1845
1846 * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
1847 * HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
1848
1849 **PLC Settings**
1850
1851 Add BD
1852
1853 * Please uncheck [Symbolic access only] option;
1854
1855
1856 (% style="text-align:center" %)
1857 [[image:12.PLC Protocol_html_643144c591994418.png||data-xwiki-image-style-alignment="center" height="546" width="550" class="img-thumbnail"]]
1858
1859 Address settings, using BD2 as example.
1860
1861 * DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1.
1862 * 2 represent DB block number
1863 * xxxx represent address
1864
1865 **Such as:**
1866
1867 * DBxDBB20000 = DB2.DBB0
1868 * DBxDBW20004 = DB2.DBW4
1869
1870 (% style="text-align:center" %)
1871 [[image:12.PLC Protocol_html_87ceaea84d552e62.png||data-xwiki-image-style-alignment="center" height="245" width="537" class="img-thumbnail"]]
1872
1873 **How to connect with S7-1200 Firmware V4.0**
1874
1875 PLC configuration
1876
1877 * Double click [device configuration] in Siemens via software
1878 * Double click [protection] to enter protection configuration screen
1879
1880 (% style="text-align:center" %)
1881 [[image:12.PLC Protocol_html_9779940d38da8e07.png||data-xwiki-image-style-alignment="center" height="426" width="341" class="img-thumbnail"]]
1882
1883 * Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)]
1884
1885 (% style="text-align:center" %)
1886 [[image:12.PLC Protocol_html_d2c667b02f9720b1.png||data-xwiki-image-style-alignment="center" height="296" width="554" class="img-thumbnail"]]
1887
1888 DB settings
1889
1890 * Right click [DB], select [properties]
1891 * Uncheck [optimized block access]
1892
1893 **Cable Wiring**
1894
1895 (% style="text-align:center" %)
1896 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1897
1898 == **LOGO Ethernet** ==
1899
1900 Supported Series: Siemens Logo
1901
1902 **HMI Settings**
1903
1904 (% class="table-bordered" %)
1905 |**Items**|**Settings**|**Note**
1906 |Protocol|Siemens LOGO|
1907 |Connection|Ethernet|
1908 |Port No.|102|
1909 |PLC station No.|2|
1910
1911 **Address List**
1912
1913 (% class="table-bordered" %)
1914 |**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
1915 |1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
1916 |2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
1917 |3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
1918 |4|VW|Word|0-1468|DB1.DBX0.0|0x000000
1919 |5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
1920 |6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
1921 |7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
1922 |8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
1923 |9|AI|Word|1-16|DB1.DBX1032.0|0x002040
1924 |10|I|Bit|1-64|DB1.DBX1024.0|0x002000
1925 |11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
1926 |12|M|Bit|1-112|DB1.DBX1104.0|0x002280
1927 |13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
1928 |14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
1929 |15|V|Bit|0-14697|DB1.DBX0.0|0x000000
1930
1931 **PLC Settings in LOGO Software:**
1932
1933 Click [Tools]~-~-[Ethernet Connections],shown as below.
1934
1935 (% style="text-align:center" %)
1936 [[image:12.PLC Protocol_html_8b9d2322edf89519.png||data-xwiki-image-style-alignment="center" height="641" width="423" class="img-thumbnail"]]
1937
1938 Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
1939
1940 (% style="text-align:center" %)
1941 [[image:12.PLC Protocol_html_6c4dd041b26cd8a1.png||data-xwiki-image-style-alignment="center" height="481" width="363" class="img-thumbnail"]]
1942
1943 **TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
1944
1945 (% style="text-align:center" %)
1946 [[image:12.PLC Protocol_html_7af2611d3790a77d.png||data-xwiki-image-style-alignment="center" height="359" width="426" class="img-thumbnail"]]
1947
1948 **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
1949
1950 (% style="text-align:center" %)
1951 [[image:12.PLC Protocol_html_3243e4cd600595cc.png||data-xwiki-image-style-alignment="center" height="368" width="554" class="img-thumbnail"]]
1952
1953
1954 (% style="text-align:center" %)
1955 [[image:12.PLC Protocol_html_cb1d92e2cc91a8db.png||data-xwiki-image-style-alignment="center" height="320" width="553" class="img-thumbnail"]]
1956
1957
1958 **HMI Communication Settings**
1959
1960 Set PLC IP in [Device IP] settings;
1961
1962 (% style="text-align:center" %)
1963 [[image:12.PLC Protocol_html_573fc64ad393cd4f.png||data-xwiki-image-style-alignment="center" height="655" width="379" class="img-thumbnail"]]
1964
1965
1966 Enable HMI Ethernet in [Project Settings];
1967
1968 (% style="text-align:center" %)
1969 [[image:12.PLC Protocol_html_95917a3d92068467.png||data-xwiki-image-style-alignment="center" height="311" width="553" class="img-thumbnail"]]
1970
1971 TSAP setting
1972
1973 * Regarding the setting of PLC TSAP, HMI provides system special address for setting, it is recommended to run in HMI script initialization, write PLC TSAP to corresponding system special register.
1974 * HSW10118 = local TSAP of HMI, this is remote TSAP of PLC.
1975 * HSW10119 = Remote TSAP of HMI, this is local TSAP of PLC.
1976
1977 **✎Note:**
1978
1979 * The data of TSAP is hexadecimal format. For example: the remote TSAP configured in the PLC is set to 20.00, then HSW10118 should be set to 0x2000, that is, HSW10118 = 8192.
1980
1981 (% style="text-align:center" %)
1982 [[image:12.PLC Protocol_html_5c6374b21f46e01e.png||data-xwiki-image-style-alignment="center" height="139" width="498" class="img-thumbnail"]]
1983
1984
1985 * AI word address and Ibit address are read-only and cannot be written on HMI.
1986 * VW address should be even number.such as VW0, VW2, VW4...
1987 * VD address it takes two VW addresses.such as VD0,VD4,VD8...
1988 * Written value of RTC cannot exceed 255.
1989
1990 **Cable Wiring**
1991
1992 (% style="text-align:center" %)
1993 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1994
1995 == **S7-XXX Ethernet** ==
1996
1997 Supported Series: Siemens S7-1200 and S7-1500
1998
1999 **HMI Setting**
2000
2001 (% class="table-bordered" %)
2002 |**Items**|**Settings**|**Note**
2003 |Protocol|Siemens S7-XXX|
2004 |Connection|Ethernet|
2005 |Port No.|102|
2006 |PLC station No.|1 (for S7-1500)/ 2 (for S7-1200)|
2007
2008 **Address List**
2009
2010 (% class="table-bordered" %)
2011 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
2012 |(% rowspan="4" %)Bit|I|I|M d.o|(((
2013 d:0~-~-9999
2014
2015 o:0-7
2016 )))|
2017 |Q|Q|Q d.o|(((
2018 d:0~-~-9999
2019
2020 o:0-7
2021 )))|
2022 |M|M|M d.o|(((
2023 d:0~-~-9999
2024
2025 o:0-7
2026 )))|
2027 |DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
2028 nn:0-9999,
2029
2030 dddd:0-9999,
2031
2032 o:0-7
2033 )))|(((
2034 nn:DB No.
2035
2036 dddd:address value
2037
2038 o: digit address
2039 )))
2040 |(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
2041 |M|MW|MW d|d:0-99999|(((
2042 MW0=MB(0~~1)
2043
2044 MW2=MB(2~~3)
2045
2046 Address value is a multiple of 2
2047 )))
2048 |M|MD|MD d|d:0-99999|(((
2049 MD0=MB(0~~3)
2050
2051 MD4=MB(4~~7)
2052
2053 Address value is a multiple of 4
2054 )))
2055 |I|IW|IW d|d:0-99999|
2056 |Q|QW|QW d|d:0-99999|
2057 |DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
2058 nn:0-9999
2059
2060 dddd:0-9999
2061 )))|(((
2062 nn:DB No.
2063
2064 dddd:address value
2065 )))
2066 |DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
2067 nn:0-9999
2068
2069 dddd:0-9999
2070 )))|(((
2071 nn:DB No.
2072
2073 dddd:address value
2074
2075 Address value is a multiple of 2
2076 )))
2077 |DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
2078 nn:0-9999
2079
2080 dddd:0-9999
2081 )))|(((
2082 nn:DB No.
2083
2084 dddd:address value
2085
2086 Address value is a multiple of 4
2087 )))
2088
2089 **Communication Settings**
2090
2091 Enable HMI Ethernet in [Project Settings];
2092
2093 (% style="text-align:center" %)
2094 [[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]]
2095
2096 Set PLC IP in [Device IP] settings;
2097
2098 (% style="text-align:center" %)
2099 [[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
2100
2101 **✎Note:**
2102
2103 * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
2104 * HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
2105
2106 **Cable Wiring**
2107
2108 {{id name="OLE_LINK8"/}}
2109
2110 (% style="text-align:center" %)
2111 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2112
2113 = **User Defined Protocol** =
2114
2115 If the device does not support MODBUS standard, and the protocol is not list in PIStudio, then user can define the protocol by following instruction to realize simply communication functions like sending and receiving commands.
2116
2117 **HMI Settings**
2118
2119 (% class="table-bordered" %)
2120 |**Items**|**Settings**|**Note**
2121 |Protocol|User defined protocol|
2122 |Connection|RS485/RS232|
2123 |Baud rate|2400~~187500|
2124 |Stop bits|1/ 2|
2125 |Data bits|7/ 8|
2126 |Parity|None/ Even/ ODD|
2127
2128 **Operating Procedures**
2129
2130 Select [User defined protocol];
2131
2132 Click [User defined protocol] button to open setting window as below;
2133
2134 (% style="text-align:center" %)
2135 [[image:12.PLC Protocol_html_5ca13817ac812cf0.png||data-xwiki-image-style-alignment="center" height="367" width="437" class="img-thumbnail"]]
2136
2137 Configure user defined command;
2138
2139 (% style="text-align:center" %)
2140 [[image:12.PLC Protocol_html_11441e69f21e243d.png||data-xwiki-image-style-alignment="center" height="525" width="553" class="img-thumbnail"]]
2141
2142 (% class="table-bordered" %)
2143 |**No**|**Item**|**Description**
2144 |1|Instruction edit|The required command.
2145 |2|Mode|Write to address or read from the address.
2146 |3|Format|Encode format: HEX or ASCII.
2147 |4|Other|(((
2148 **No receiving: **HMI does not respond to the receiving command.
2149
2150 **Send after receiving:** HMI responds to the receiving command.
2151 )))
2152 |5|Manually send|(((
2153 Respond once after trigger the address.
2154
2155 Address: set the trigger address.
2156 )))
2157 |6|Add|Save this setting.
2158 |7|Cancel|Cancel current settings.
2159 |(% rowspan="4" %)8|Add|Add a new command.
2160 |Edit|Edit the selected command.
2161 |Delete|Delete the selected command.
2162 |Clear|Clear all the commands.
2163 |9|Instruction list|Display all current commands.
2164 |10|Address List|Display all the addresses added.
2165 |(% rowspan="5" %)11|Import|Import the command files to the instruction list.
2166 |Export|Export current command settings to local storage.
2167 |Browse|Browse local command files.
2168 |Advanced|Combine two commands.
2169 |Exit|Complete editing and exit setting.
2170
2171 **Operating Procedures**
2172
2173 Click [Add] to create a new command, as below shows;
2174
2175 (% style="text-align:center" %)
2176 [[image:12.PLC Protocol_html_463f2cd3a8c338fc.png||data-xwiki-image-style-alignment="center" height="116" width="88" class="img-thumbnail"]]
2177
2178 Select mode, [Read] or [Write], and then select Format, there are two options [Hex] and [ASCII]. As below shows;
2179
2180 (% style="text-align:center" %)
2181 [[image:12.PLC Protocol_html_a48eba3aa30b612d.png||data-xwiki-image-style-alignment="center" height="80" width="121" class="img-thumbnail"]]
2182
2183 Other settings: [No receiving] means HMI only sends command, and it would not process the reply command which from device. [Send after receiving] means HMI will be receiving the command which from device firstly, and then sending the command to device. From example, when HMI receiving [00 FF 00] firstly and then send command, as below shows
2184
2185 (% style="text-align:center" %)
2186 [[image:12.PLC Protocol_html_b36d990e126365d.png||data-xwiki-image-style-alignment="center" height="77" width="179" class="img-thumbnail"]]
2187
2188 Check [Manually send], and then please set the address for trigging, the setting range is 1~~10, and please put Bit switch in project screen for it, and [OneCtrlBit] register is for [Manually send].
2189
2190 Instruction edit, when the data format is HEX, please use two numbers to represent one 16-bit number. ASCII format using characters to input;
2191
2192 Check settings;
2193
2194 (% style="text-align:center" %)
2195 [[image:12.PLC Protocol_html_5ac7075d9e8dad8d.png||data-xwiki-image-style-alignment="center" height="185" width="554" class="img-thumbnail"]]
2196
2197 (% class="table-bordered" %)
2198 |**No**|**Items**|**Description**
2199 |1|Add checking|Add checking command when receiving the data.
2200 |(% rowspan="2" %)2|Back checking|Add control character in ASCII format.
2201 |Differ with send check|Set return checking.
2202 |(% rowspan="2" %)3|(% rowspan="2" %)Add control character|Start position: select the start position of the data which need to check.
2203 |Length: The data length need to be checked.
2204
2205 Object settings;
2206
2207 (% style="text-align:center" %)
2208 [[image:12.PLC Protocol_html_1e776a838316fb5.png||data-xwiki-image-style-alignment="center" height="185" width="554" class="img-thumbnail"]]
2209
2210 (% class="table-bordered" %)
2211 |**No**|**Items**|**Description**
2212 |(% rowspan="3" %)1|(% rowspan="3" %)Object settings|Object type: bit or word address;
2213 |Address: the triggering address;
2214 |Note: description to object;
2215 |2|Byte order|The numerical display order;
2216
2217 Data length settings;
2218
2219 (% style="text-align:center" %)
2220 [[image:12.PLC Protocol_html_6959664a46b03b69.png||data-xwiki-image-style-alignment="center" height="185" width="554" class="img-thumbnail"]]
2221
2222 (% class="table-bordered" %)
2223 |**No**|**Item**|**Description**
2224 |(% rowspan="2" %)1|(% rowspan="2" %)Return data|Position: the start position of the return data.
2225 |Length: the return data length.
2226 |(% rowspan="2" %)2|(% rowspan="2" %)Write data|Position: the start position of the write data.
2227 |Length: the write data length.
2228
2229 Instruction length settings
2230
2231 (% style="text-align:center" %)
2232 [[image:12.PLC Protocol_html_7e0d8613c5e12f7b.png||data-xwiki-image-style-alignment="center" height="185" width="554" class="img-thumbnail"]]
2233
2234 (% class="table-bordered" %)
2235 |**No**|**Item**|**Description**
2236 |1|Send length|The instruction data will only send designated data length.
2237 |2|Return length|The responds data length.
2238 |3|End code|Instruction will not be terminated until receiving [End code];
2239
2240 **Cable Wiring**
2241
2242 * **RS485**
2243
2244 (% style="text-align:center" %)
2245 [[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]]
2246
2247 (% style="text-align:center" %)
2248 [[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
2249
2250 * **RS232**
2251
2252 (% style="text-align:center" %)
2253 [[image:12.PLC Protocol_html_5de71638aab8e40d.png||data-xwiki-image-style-alignment="center" height="205" width="385" class="img-thumbnail"]]
2254
2255 **✎Note:** COM3 only available in PI8000/PI9000 series.
2256
2257 = **WECON PLC** =
2258
2259 Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
2260
2261 **HMI Settings**
2262
2263 (% class="table-bordered" %)
2264 |**Item**|**Settings**|**Note**
2265 |Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
2266 |Connection|RS422/RS485|
2267 |Baud rate|9600|
2268 |Data bit|7|
2269 |Parity|EVEN|
2270 |Stop bit|1|
2271 |PLC station No.|1|
2272
2273 **Address List**
2274
2275 (% class="table-bordered" %)
2276 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
2277 |(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
2278 |Y|Y|Y o|0~~303237|
2279 |M|M|M d|0~~99999|
2280 |T|T|T d|0~~99999|
2281 |C|C|C d|0~~99999|
2282 |S|S|S d|0~~99999|
2283 |(% rowspan="8" %)Word|X|X|Xo|0~~303237|
2284 |Y|Y|Y o|0~~303237|
2285 |M|M|M d|0~~99999|
2286 |T|T|T d|0~~99999|
2287 |C|C|C d|0~~199|
2288 |D|D|D d|0~~7999|
2289 |S|S|S d|0~~99999|
2290 |SD|SD|SD d|8000~~9999|
2291
2292 **Cable Wiring**
2293
2294 * **RS485**
2295
2296 (% style="text-align:center" %)
2297 [[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]]
2298
2299 (% style="text-align:center" %)
2300 [[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
2301
2302 * **RS422**
2303
2304 (% style="text-align:center" %)
2305 [[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]]
2306
2307 **✎Note:**
2308
2309 * HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) .
2310 * If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual.
2311
2312 [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
2313
2314 = **Printer** =
2315
2316 == **TSPL label printer** ==
2317
2318 **Introduction**
2319
2320 TSPL label printer protocol supports following models.
2321
2322 * SPRT TL21: [[https:~~/~~/www.sprinter.com.cn/show-60-62-1.html>>https://www.sprinter.com.cn/show-60-62-1.html]]
2323 * DL-888D: [[https:~~/~~/www.deliworld.com/product/detail/7624>>https://www.deliworld.com/product/detail/7624]]
2324
2325 **Setting Step**
2326
2327 Select the protocol
2328
2329 * Create a new project, select the TSPL label printer protocol as shown below.
2330
2331 (% style="text-align:center" %)
2332 [[image:12.PLC Protocol_html_a2bec264816230db.png||data-xwiki-image-style-alignment="center" height="331" width="495" class="img-thumbnail"]]
2333
2334 Set parameters
2335
2336 * The connection between the TSPL label printer and the HMI is via the USB-A interface, no need to configure serial port parameters.
2337
2338 Printer register
2339
2340 (% class="table-bordered" %)
2341 |**Register**|**System**|**Range**|**Function**
2342 |TSPL_SP|decimal|0 - 1|Set the paper size
2343 |TSPL_PT|decimal|0 - 1999|Print text
2344 |TSPL_PQ|decimal|0 - 999|Print QR code
2345 |TSPL_PB|decimal|0 - 999|Print barcode
2346 |TSPL_PR|decimal|0 - 1|Print offset
2347 |TSPL_PN|decimal|0 - 0|Trigger printing
2348 |TSPL_PS|decimal|0 - 0|Print status
2349
2350 * Set paper size:
2351 ** TSPL_SP0: width of paper, unit: mm.
2352 ** TSPL_SP1: height of paper, unit: mm.
2353 * Print text:
2354 ** TSPL_PT can print up to 20 texts. TSPL_PT0-TSPL_PT99 is the first text; TSPL_PT100-TSPL_PT199 is the second text; … TSPL_PT1000-TSPL_PT1999 is the 20th text.
2355 ** Detailed parameter settings of each text is shown as below table. For example, first text,TSPL_PT0-TSPL_PT99.
2356
2357 (% class="table-bordered" %)
2358 |**Register**|**Function**|**Description**
2359 |TSPL_PT0|X coordinate|Unit: dot
2360 |TSPL_PT1|Ycoordinate|Unit: dot
2361 |TSPL_PT2|Rotation angle|(((
2362 0: 0 degrees
2363
2364 1: 90 degrees
2365
2366 2: 180 degrees
2367
2368 3: 270 degrees
2369 )))
2370 |TSPL_PT3|Size|Range: 0-3
2371 |TSPL_PT4 - TSPL_PT99|QR code content(text content)|Use character input device to configure
2372
2373 By analogy, we can know the text information configuration of the 2nd to 20th QR codes
2374
2375 Print QR code:
2376
2377 * TSPL_PQ can print up to 10 QR codes. TSPL_PQ0-TSPL_PQ99 is the first QR code; TSPL_PQ100-TSPL_PQ199 is the second QR code; ...., TSPL_PQ900-TSPL_PQ999 is the tenth QR code.
2378 * Specific parameter description of each item: for example, the first QR code, TSPL_PQ0-TSPL_PQ99:
2379
2380 (% class="table-bordered" %)
2381 |**Register**|**Function**|**Description**
2382 |TSPL_PQ0|X coordinate|Unit: dot
2383 |TSPL_PQ1|Ycoordinate|Unit: dot
2384 |TSPL_PQ2|Rotation angle|(((
2385 0: 0 degrees
2386
2387 1: 90 degrees
2388
2389 2: 180 degrees
2390
2391 3: 270 degrees
2392 )))
2393 |TSPL_PQ3|Size|Range: 0-5
2394 |TSPL_PQ4 - TSPL_PQ99|QR code content|Use character input device to configure
2395
2396 * By analogy, we can know the text information configuration of the 2nd to 20th QR codes.
2397
2398 Print bar code:
2399
2400 * TSPL_PB can print up to 10 barcodes. TSPL_PB0-TSPL_PB99 is the first bar code; TSPL_PB100-TSPL_PB199 is the second bar code; ..., TSPL_PB900-TSPL_PB999 is the tenth bar code.
2401 * Specific parameter description of each item: for example, the first barcode, TSPL_PB0-TSPL_PB99:
2402
2403 (% class="table-bordered" %)
2404 |**Register**|**Function**|**Description**
2405 |TSPL_PB0|X coordinate|Unit: dot
2406 |TSPL_PB1|Ycoordinate|Unit: dot
2407 |TSPL_PB2|Rotation angle|(((
2408 0: 0 degrees
2409
2410 1: 90 degrees
2411
2412 2: 180 degrees
2413
2414 3: 270 degrees
2415 )))
2416 |TSPL_PB3|height|Unit: dot
2417 |TSPL_PB4|width|Range:0-2
2418 |TSPL_PB5- TSPL_PB99|Bar code content|Use character input device to configure
2419
2420 By analogy, we can know the text information configuration of the 2nd to 20th bar codes.
2421
2422 Print offset:
2423
2424 * TSPL_PR0: X coordinate offset, unit: mm;
2425 * TSPL_PR1: Y coordinate offset, unit: mm.
2426
2427 Trigger printing:
2428
2429 * TSPL_PN0 = 1: trigger the printer to start printing.
2430
2431 Printing status:
2432
2433 * TSPL_PS0 = 1: The printing is normal.
2434 * TSPL_PS0 = 1: The printing is abnormal.
2435
2436 Print picture
2437
2438 * For the function of printing pictures, please refer to the configuration of [Printer object].
2439
2440 Conversion between dot and mm
2441
2442 * Dot is the meaning of pixels. For the conversion between dot and mm, please refer to the printer manual or consult the customer service of the corresponding printer manufacturer. For example, SPRT TL21: 8 dots / mm, that is, 1mm = 8 dot.
2443
2444 == **EpsonTM series** ==
2445
2446 **HMI Settings**
2447
2448 (% class="table-bordered" %)
2449 |**Item**|**Settings**|**Note**
2450 |Protocol|EPSON-TM-T82II/TM-XXX|
2451 |Connection|RS232|
2452 |Baud rate|9600~~115200|
2453 |Data bit|8|
2454 |Parity|None|
2455 |Stop bit|1|
2456 |PLC station No.|1|
2457
2458 Each printer protocol has default parameter. These parameters could be configured by addresses. Error parameters may cause print failure.
2459
2460 **Printer Settings**
2461
2462 (% class="table-bordered" %)
2463 |(% style="width:504px" %)**Address**|(% style="width:778px" %)**Description**|(% style="width:208px" %)**Value**
2464 |(% style="width:504px" %)HSW10603|(% style="width:778px" %)Print direction (only valid for print function)|(% style="width:208px" %)1
2465 |(% style="width:504px" %)HSW10604|(% style="width:778px" %)Dot Matrix Type|(% style="width:208px" %)1
2466 |(% style="width:504px" %)HSW10605|(% style="width:778px" %)Print width (depending on printer and paper)|(% style="width:208px" %)384
2467 |(% style="width:504px" %)HSW10606|(% style="width:778px" %)Printer instruction type|(% style="width:208px" %)1
2468 |(% style="width:504px" %)HSW10607|(% style="width:778px" %)Paper cut|(% style="width:208px" %)2
2469 |(% style="width:504px" %)HSW10608|(% style="width:778px" %)Alignment (only valid for print function)|(% style="width:208px" %)1
2470
2471 **Cable Wiring**
2472
2473 (% style="text-align:center" %)
2474 [[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]]
2475
2476 (% style="text-align:center" %)
2477 [[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
2478
2479 **✎Note:** COM3 only available in PI8000/PI9000 series.