Wiki source code of 01 Getting Started
Last modified by Mora Zhou on 2024/12/05 14:00
Hide last authors
author | version | line-number | content |
---|---|---|---|
![]() |
8.1 | 1 | (% class="wikigeneratedid" id="HPIStudio" %) |
![]() |
108.3 | 2 | PIStudio (HMI configuration software) Help can help you master the basic operation and usage of the configuration software more quickly, and assist you in completing your work successfully. |
![]() |
20.1 | 3 | |
4 | (% class="wikigeneratedid" %) | ||
![]() |
55.1 | 5 | The following steps will show how to install PISudio. |
![]() |
1.1 | 6 | |
![]() |
11.1 | 7 | = Requirement = |
![]() |
1.1 | 8 | |
![]() |
54.1 | 9 | PISudio installation package downloaded. |
![]() |
1.1 | 10 | |
11 | * Windows 7 (32bit / 64bit) | ||
12 | * Windows 8 (32bit / 64bit) | ||
13 | * Windows 8.1 (32bit / 64bit) | ||
14 | * Windows 10 (32bit / 64bit) | ||
15 | |||
![]() |
11.1 | 16 | = Download = |
![]() |
1.1 | 17 | |
![]() |
108.3 | 18 | [[Download>>https://docs.we-con.com.cn/bin/view/PIStudio/Download/3%20Software/]] |
![]() |
1.1 | 19 | |
![]() |
18.1 | 20 | = Installation = |
![]() |
7.1 | 21 | |
![]() |
11.1 | 22 | Steps: |
![]() |
1.1 | 23 | |
![]() |
3.2 | 24 | ((( |
![]() |
55.1 | 25 | 1. Decompress downloaded file get PISudio installation package. |
![]() |
53.1 | 26 | 1. Select PISudio installation package. |
![]() |
108.3 | 27 | 1. Right-click it. |
![]() |
1.1 | 28 | 1. Select "Run as administrator". |
![]() |
108.3 | 29 | 1. Select language for PISudio, it supports Chinese (Simplified), Chinese (Traditional), English, Italian, Russian. |
![]() |
3.2 | 30 | ))) |
![]() |
1.1 | 31 | |
32 | (% style="text-align:center" %) | ||
33 | [[image:2.Installation Software_html_f3d49e1396c6e4f6.png||data-xwiki-image-style-alignment="center" height="153" width="300" class="img-thumbnail"]] | ||
34 | |||
35 | (% start="6" %) | ||
36 | 1. Click "Next". | ||
37 | |||
38 | (% style="text-align:center" %) | ||
![]() |
53.1 | 39 | [[image:2.Installation Software_html_a8017b2a399a513a.png||data-xwiki-image-style-alignment="center" class="img-thumbnail"]] |
![]() |
1.1 | 40 | |
41 | (% start="7" %) | ||
![]() |
53.1 | 42 | 1. If there is a previous version of PISudio on the PC, please remove it before installation. |
43 | 1. Select a folder for PISudio installation, or use the default folder, then click "Next". | ||
![]() |
1.1 | 44 | |
45 | (% style="text-align:center" %) | ||
![]() |
53.1 | 46 | [[image:2.Installation Software_html_e36b4ee18ae58696.png||data-xwiki-image-style-alignment="center" class="img-thumbnail"]] |
![]() |
1.1 | 47 | |
48 | (% start="9" %) | ||
![]() |
108.3 | 49 | 1. Click "Browse..." to specify a folder, or use the folder suggested by the program, click "Next" to continue the installation process. |
![]() |
1.1 | 50 | |
51 | (% start="10" %) | ||
52 | 1. Select additional tasks, for example: "Create a desktop icon". Click "Next". | ||
53 | |||
54 | (% style="text-align:center" %) | ||
![]() |
50.2 | 55 | [[image:2.Installation Software_html_4e0e99bed6dace57.png||data-xwiki-image-style-alignment="center" class="img-thumbnail"]] |
![]() |
1.1 | 56 | |
57 | (% start="11" %) | ||
![]() |
44.3 | 58 | 1. At this stage, all settings have been completed. Please check if it is correct. If there is any need to re-select the part, please press "Back". If all is correct, please press "Install" to start the installation process. |
59 | |||
![]() |
1.1 | 60 | (% style="text-align:center" %) |
![]() |
53.1 | 61 | [[image:2.Installation Software_html_4a34d864617e2e2c.png]] |
![]() |
44.3 | 62 | |
![]() |
45.2 | 63 | (% start="12" %) |
![]() |
1.1 | 64 | 1. Installer execution |
65 | |||
66 | (% style="text-align:center" %) | ||
![]() |
53.1 | 67 | [[image:2.Installation Software_html_cffc7ff7dee59cd6.png||data-xwiki-image-style-alignment="center" class="img-thumbnail"]] |
![]() |
1.1 | 68 | |
69 | (% start="13" %) | ||
70 | 1. Please check "Launch VC Runtime" to install "Microsoft Visual C++2008" in your PC. | ||
71 | |||
72 | (% style="text-align:center" %) | ||
![]() |
50.2 | 73 | [[image:2.Installation Software_html_8ac33d46970c9f0a.png||data-xwiki-image-style-alignment="center" class="img-thumbnail"]] |
![]() |
1.1 | 74 | |
![]() |
53.1 | 75 | **Result: **Users could see shortcuts to PISudio's features in the "Start" » "All Programs" » “PISudio” directory. |
![]() |
1.1 | 76 | |
![]() |
79.1 | 77 | (% class="box infomessage" %) |
78 | ((( | ||
![]() |
1.1 | 79 | ✎**Note:** |
80 | |||
![]() |
53.1 | 81 | * In case of incompatible problems, it is suggested to install and run PISudio as administrator. |
![]() |
80.1 | 82 | * Microsoft Visual C++ 2008 provides the necessary runtime components for PISudio. |
![]() |
79.1 | 83 | ))) |
![]() |
1.1 | 84 | |
![]() |
8.1 | 85 | = PISuite (Toolkit) = |
![]() |
1.1 | 86 | |
87 | In addition to being editable on PIStudio, HMI has other related components that can be used. | ||
88 | |||
![]() |
10.1 | 89 | Open the "Start" ->"All Programs" ->HMI Editor installation directory to quickly open functional tool. |
![]() |
1.1 | 90 | |
91 | (% style="text-align:center" %) | ||
92 | [[image:工具箱 1.png||data-xwiki-image-style-alignment="center" class="img-thumbnail"]] | ||
93 | |||
94 | (% style="text-align:center" %) | ||
95 | [[image:工具箱 2.png||data-xwiki-image-style-alignment="center" class="img-thumbnail"]] | ||
96 | |||
97 | (% class="wikigeneratedid" %) | ||
98 | The tools of toolkit are as follows. | ||
99 | |||
100 | (% class="table-bordered" %) | ||
101 | |=(% style="width: 200px;" %)Tool|=(% style="width: 118px;" %)Icon|=(% style="width: 756px;" %)Function | ||
![]() |
21.1 | 102 | |(% style="width:200px" %)[[Download>>https://docs.we-con.com.cn/bin/view/PIStudio/14.Tools/#HDownloadproject]]|(% style="width:118px" %)[[image:工具箱 3.png||height="66" width="66"]]|(% style="width:756px" %)Get information about HMI such as upload and download project, updata HMI's time, get HMI version, get machine colde etc,. |
103 | |(% style="width:200px" %)[[Decompile>>https://docs.we-con.com.cn/bin/view/PIStudio/14.Tools/#HDecompile]]|(% style="width:118px" %)[[image:工具箱 4.png||height="66" width="66"]]|(% style="width:756px" %)After reading the project from HMI to PC, you need to decomcompile the project before opening it with PIStudio. | ||
![]() |
1.1 | 104 | |(% style="width:200px" %)DataLogTool|(% style="width:118px" %)[[image:工具箱 5.png||height="62" width="66"]]|(% style="width:756px" %)To view the "DB" such as file data records, alarm records or operation records collected by HMI. You could also convert it to "excel" format. |
105 | |(% style="width:200px" %)LogoMakerTool|(% style="width:118px" %)[[image:工具箱 6.png||height="66" width="66"]]|(% style="width:756px" %)To make the boot logo of PI series HMI. | ||
106 | |(% style="width:200px" %)DataUpload|(% style="width:118px" %)[[image:工具箱 7.png]]|(% style="width:756px" %)Upload data record ,alarm records or operation records collected by HMI. | ||
![]() |
21.1 | 107 | |(% style="width:200px" %)[[PIRecordUpload>>https://docs.we-con.com.cn/bin/view/PIStudio/14.Tools/#HDataRecordUpload28Onlyigseries29]]|(% style="width:118px" %)[[image:工具箱 8.png]]|(% style="width:756px" %)Monitor devices in real time, update and export data records, alarm records or operation records collected by HMI synchronously. (Only supported by ig Sseries) |
108 | |(% style="width:200px" %)[[CreatInstallmentPwd>>https://docs.we-con.com.cn/bin/view/PIStudio/14.Tools/#HPasswordtool]]|(% style="width:118px" %)[[image:工具箱 9.png]]|(% style="width:756px" %)The installment payment mode is dynamic password. You can use the Installment password tool "CreatInstallmentPwd" to generate the dynamic password. | ||
![]() |
1.1 | 109 | |(% style="width:200px" %)PIMonitor|(% style="width:118px" %)[[image:工具箱 10.png]]|(% style="width:756px" %)LAN monitoring of 3000 series HMI screen. |
![]() |
21.1 | 110 | |(% style="width:200px" %)[[Levi2PI>>https://docs.we-con.com.cn/bin/view/PIStudio/17.Levi2PI/]]|(% style="width:118px" %)[[image:工具箱 11.png||height="67" width="66"]]|(% style="width:756px" %)Convert LEVI series engineering to PI series engineering. |
![]() |
1.1 | 111 | |(% style="width:200px" %)HMIPrjStdNeutral|(% style="width:118px" %)[[image:工具箱 12.png]]|(% style="width:756px" %)Project conversion between PI standard and PI neutral version |
112 | |(% style="width:200px" %)PIRptEditTool|(% style="width:118px" %)[[image:工具箱 13.png]]|(% style="width:756px" %)Convert the record files generated by LEVI or PI to the specified format. | ||
113 | |(% style="width:200px" %)HMIProjectReportTool|(% style="width:118px" %)[[image:工具箱 14.png]]|(% style="width:756px" %)Analyze and generate HMI engineering report. | ||
114 | |||
![]() |
81.1 | 115 | (% class="box infomessage" %) |
116 | ((( | ||
![]() |
1.1 | 117 | **✎Note:** HMI supports the use of USB and Ethernet to download/upload project and record files. |
![]() |
81.1 | 118 | ))) |
![]() |
1.1 | 119 | |
![]() |
16.1 | 120 | = Getting Started = |
![]() |
1.1 | 121 | |
![]() |
71.1 | 122 | This chapter provides a quick and precise introduction of PISudio. |
![]() |
1.1 | 123 | |
124 | It does not contain a comprehensive list of all functions, but it only takes 6 simple steps to create a new project. | ||
125 | |||
126 | (% class="table-bordered" %) | ||
127 | |=(% style="width: 243px;" %)Operation |=(% style="width: 832px;" %)Description | ||
128 | |(% style="width:243px" %)((( | ||
![]() |
14.1 | 129 | 1. [[Create a new project>>||anchor="HCreatenewproject"]] |
![]() |
1.1 | 130 | )))|(% style="width:832px" %)((( |
131 | [[image:新建工程 4.png]] | ||
132 | |||
![]() |
108.4 | 133 | Click the "New" in the upper left corner of the software to create a new project. You could click [["New screen">>https://docs.we-con.com.cn/bin/view/PIStudio/04.Software%20Menu/#HScreen]] to create a new screen. See the [["Screen Style (only for ig series)">>https://docs.we-con.com.cn/bin/view/PIStudio/04.Software%20Menu/#HScreenstyle28Onlyigseries29]] for details. |
![]() |
1.1 | 134 | ))) |
135 | |(% style="width:243px" %)((( | ||
136 | (% start="2" %) | ||
![]() |
21.1 | 137 | 1. [[Project Settings>>doc:PIStudio.05\.Project Settings.WebHome]] |
![]() |
1.1 | 138 | )))|(% style="width:832px" %)((( |
139 | [[image:工程配置 1.png]] | ||
140 | |||
![]() |
47.2 | 141 | Click [["Communication">>https://docs.we-con.com.cn/bin/view/PIStudio/05.Project%20Settings/#HCommunication]] and [["Project settings">>doc:PIStudio.05\.Project Settings.WebHome]] to set communication protocol and port parameters. |
![]() |
1.1 | 142 | ))) |
143 | |(% style="width:243px" %)((( | ||
144 | (% start="3" %) | ||
145 | 1. Project design | ||
![]() |
47.2 | 146 | )))|(% style="width:832px" %)Create screens and place the objects you need. You could draw your own project through [["draw">>https://docs.we-con.com.cn/bin/view/PIStudio/06.Objects/#HDraw]], import the required pictures and vector maps using [["Shape">>https://docs.we-con.com.cn/bin/view/PIStudio/7.Library/#HShape]] library, and enrich the project as much as possible by using the diversified objects. |
![]() |
1.1 | 147 | |(% style="width:243px" %)((( |
148 | (% start="4" %) | ||
149 | 1. Compile and save | ||
150 | )))|(% style="width:832px" %)((( | ||
![]() |
21.1 | 151 | You need to [["compile">>https://docs.we-con.com.cn/bin/view/PIStudio/14.Tools/#HCompileProject]] every project before downloading to it HMI. |
![]() |
1.1 | 152 | |
![]() |
21.1 | 153 | When uploading a project from the HMI to the PC, you need [["Decompile">>https://docs.we-con.com.cn/bin/view/PIStudio/14.Tools/#HDecompile]]. |
![]() |
1.1 | 154 | ))) |
155 | |(% style="width:243px" %)((( | ||
156 | (% start="5" %) | ||
![]() |
47.2 | 157 | 1. [[Simulaion>>https://docs.we-con.com.cn/bin/view/PIStudio/14.Tools/#HSimulation]] |
![]() |
1.1 | 158 | )))|(% style="width:832px" %)((( |
![]() |
47.2 | 159 | HMIEditorP provides two simulation modes: offline simulation and online simulation. |
![]() |
1.1 | 160 | |
![]() |
21.1 | 161 | 1. **Offline: **Simulate the operation of the HMI and PL on the computer. There is no need to connect with PLC. |
162 | 1. **Online: **Simulate the operation of the HMI and PL on the computer, but require the PC to be connected to the PLC and set the correct communication parameters. There is a 30-minute time limit for using online simulations. | ||
![]() |
1.1 | 163 | ))) |
164 | |(% style="width:243px" %)((( | ||
165 | (% start="6" %) | ||
![]() |
21.1 | 166 | 1. [[Download project>>https://docs.we-con.com.cn/bin/view/PIStudio/14.Tools/#HDownloadproject]] |
![]() |
47.2 | 167 | )))|(% style="width:832px" %)Downloading is the last step. After completing the download, the HMI can run the designed project, and the project downloaded to the HMI can also be uploaded to the PC. |
![]() |
1.1 | 168 | |
![]() |
14.2 | 169 | == Create new project == |
![]() |
1.1 | 170 | |
171 | The following steps will show how to start PIStudio and create a project. | ||
172 | |||
173 | **Requirement** | ||
174 | |||
175 | PIStudio programming software is installed. | ||
176 | |||
![]() |
43.2 | 177 | **Operating Procedure** |
![]() |
1.1 | 178 | |
![]() |
60.1 | 179 | 1. Start PISudio software by clicking icon, or from Start Menu. |
180 | 1. Find " PISudio" folder. | ||
181 | 1. Click " PISudio" icon to start software. | ||
![]() |
1.1 | 182 | |
183 | (% style="text-align:center" %) | ||
![]() |
110.1 | 184 | [[image:PI1.jpg||alt="新建工程 1.gif" class="img-thumbnail"]] |
![]() |
1.1 | 185 | |
186 | (% start="4" %) | ||
187 | 1. Click "New project". | ||
188 | |||
189 | (% style="text-align:center" %) | ||
![]() |
110.1 | 190 | [[image:PI2.jpg||alt="新建工程 2.png" class="img-thumbnail"]] |
![]() |
1.1 | 191 | |
192 | (% start="5" %) | ||
193 | 1. Configure project name, project path. | ||
194 | 1. Select HMI model and communication protocol. | ||
195 | 1. Click "OK" to save setting. | ||
196 | |||
197 | (% style="text-align:center" %) | ||
![]() |
52.1 | 198 | [[image:新建工程 3.gif||class="img-thumbnail"]] |
![]() |
1.1 | 199 | |
200 | **Result** | ||
201 | |||
202 | * User could find a folder named HMIProject on the desktop. | ||
203 | * In the folder user could find a file with a suffix named ".pi". Double click the file to open the project. | ||
204 | |||
![]() |
16.1 | 205 | == Add screen == |
![]() |
1.1 | 206 | |
![]() |
47.2 | 207 | The following steps will show how to create and rename screens in HMIEditorP. |
![]() |
1.1 | 208 | |
209 | New screens, which are still blank, could be created using the "Common object". User could choose different objects to design screen according to project's requirements. | ||
210 | |||
211 | **Requirement** | ||
212 | |||
213 | The "Quick_Start" project is open. | ||
214 | |||
![]() |
2.1 | 215 | **Steps:** |
![]() |
1.1 | 216 | |
217 | 1. Create a new process screen: Clicking "New" will appear "New screen" setting. | ||
218 | |||
219 | (% style="text-align:center" %) | ||
![]() |
110.2 | 220 | [[image:PI3.jpg||alt="新建画面 1.gif" class="img-thumbnail"]] |
![]() |
1.1 | 221 | |
222 | (% start="2" %) | ||
223 | 1. Set screen parameter in "New Screen", such as screen number, screen name, background type. | ||
224 | |||
225 | (% style="text-align:center" %) | ||
![]() |
111.1 | 226 | [[image:企业微信截图_17333673989587.png||alt="新建画面 2.gif" class="img-thumbnail"]] |
![]() |
1.1 | 227 | |
228 | (% start="3" %) | ||
229 | 1. After making a new screen, user could insert objects in screen. For example, button and trend. | ||
230 | 1. Add button object in screen. | ||
![]() |
47.2 | 231 | 1. Set button object parameters, such as read address, mode, etc. |
![]() |
1.1 | 232 | |
233 | (% style="text-align:center" %) | ||
![]() |
111.1 | 234 | [[image:PI5.png||alt="新建画面 3.gif" class="img-thumbnail"]] |
![]() |
1.1 | 235 | |
236 | (% start="6" %) | ||
237 | 1. Add "Trend Chart" from "Chart". | ||
238 | |||
239 | (% style="text-align:center" %) | ||
240 | [[image:新建画面 4.gif||class="img-thumbnail"]] | ||
241 | |||
242 | (% start="7" %) | ||
243 | 1. And "Function key" for screens switch. | ||
244 | |||
245 | **Result** | ||
246 | |||
![]() |
47.2 | 247 | Do a project screen with a bit button, one chart display object, and one Function key for switching screen. |
![]() |
12.1 | 248 | |
![]() |
16.1 | 249 | == Project size limits == |
![]() |
12.1 | 250 | |
251 | * 3000 series limits the project file size to 25M | ||
252 | * 3070i series limit the project file size to 25M | ||
253 | * 3070ie series limit the project file size to 22M | ||
254 | * 3070ig series limit the project file size to 25M | ||
255 | * 8000&9000 series limit the project file size to 165M | ||
![]() |
22.1 | 256 | |
257 | = Create communication with WECON PLC = | ||
258 | |||
![]() |
35.1 | 259 | (% class="wikigeneratedid" %) |
260 | [[11 PLC Protocol - Wecon (we-con.com.cn)>>https://docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/#HCreatecommunicationwithWECONPLC]] | ||
![]() |
86.1 | 261 | |
![]() |
100.1 | 262 | = Upgrade from old(LEVI) project = |
263 | |||
264 | == **General** == | ||
265 | |||
266 | This document mainly introduces how to use the conversion tool Levi2PI. Its function is converting the project from Levi to PI. | ||
267 | |||
268 | (% style="text-align:center" %) | ||
269 | [[image:LEVI2PI_html_1f551a34b9514d7c.png]] | ||
270 | |||
271 | == **Operation steps** == | ||
272 | |||
![]() |
107.1 | 273 | ((( |
![]() |
106.1 | 274 | **Select source project** |
275 | ))) | ||
![]() |
100.1 | 276 | |
277 | Select the .ump file of Levi project. | ||
278 | |||
279 | (% style="text-align:center" %) | ||
280 | [[image:LEVI2PI_html_69bf6c9539a62a15 (1).png]] | ||
281 | |||
![]() |
106.1 | 282 | **Select destination** |
![]() |
100.1 | 283 | |
284 | Select the saved path of converted project. | ||
285 | |||
286 | (% style="text-align:center" %) | ||
287 | [[image:LEVI2PI_html_e0a8696b9eda61ee.png]] | ||
288 | |||
![]() |
107.1 | 289 | **Convert** |
![]() |
100.1 | 290 | |
291 | Click the "Start" to start conversion. | ||
292 | |||
293 | (% style="text-align:center" %) | ||
294 | [[image:LEVI2PI_html_21849369a58dc272 (1).png]] | ||
295 | |||
296 | It will pop up a reminder to confirm the model to be converted.At present we don't support changing model at this process. Please change that in PIStudio after conversion done. Click “Yes” to continue. | ||
297 | |||
298 | (% style="text-align:center" %) | ||
299 | [[image:LEVI2PI_html_a7c00d5cb446622b (1).png]] | ||
300 | |||
301 | After the conversion is finished,it can click the “OPEN” button to quick open the project. | ||
302 | |||
303 | (% style="text-align:center" %) | ||
304 | [[image:LEVI2PI_html_375ef97c32946fc8.png]] | ||
305 | |||
306 | Currently most Levi models are converted into PI3000 series or PI3000i series by default. | ||
307 | |||
308 | So if you want to change the model, please remember to change it in PIStudio. | ||
309 | |||
310 | (% style="text-align:center" %) | ||
311 | [[image:LEVI2PI_html_3fc4689aa730099d.png]] | ||
312 | |||
![]() |
107.1 | 313 | **Appearance** |
![]() |
100.1 | 314 | |
315 | **Original project:** To choose the ump file you want to convert | ||
316 | |||
317 | **Purpose project:** To choose the converted project saved path. | ||
318 | |||
319 | (% style="text-align:center" %) | ||
320 | [[image:LEVI2PI_html_f47a745337309281.png]] | ||
321 | |||
322 | Print out the info of conversion. | ||
323 | |||
324 | **LEVI software:** To choose the LeviStudioU or HMIEditorU Editor.exe file for original project. | ||
325 | |||
326 | (% style="text-align:center" %) | ||
327 | [[image:LEVI2PI_html_74559da3a782d43c.png]] | ||
328 | |||
329 | **PI software:** To choose the PIstudio or HMIstudioP Editor.exe file for conversion. | ||
330 | |||
331 | (% style="text-align:center" %) | ||
332 | [[image:LEVI2PI_html_718d5f0f834821ed.png]] | ||
333 | |||
334 | **Informations:** To view original project's basic info. | ||
335 | |||
336 | (% style="text-align:center" %) | ||
337 | [[image:LEVI2PI_html_925b4e6c906746c3.png]] | ||
338 | |||
339 | **Records:** To view historical convert records. | ||
340 | |||
341 | **Start:** To start the conversion. | ||
342 | |||
343 | **Open report:** To get the convert report(A HTML format file). | ||
344 | |||
345 | (% style="text-align:center" %) | ||
346 | [[image:LEVI2PI_html_c37ae5ba105cc8a5.png]] | ||
347 | |||