Changes for page 3 Software

Last modified by Jett on 2025/03/13 14:13

From version 11.1
edited by Stone Wu
on 2022/08/01 17:09
Change comment: There is no comment for this version
To version 16.1
edited by Mora Zhou
on 2023/10/27 09:23
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Stone
1 +XWiki.Mora
Content
... ... @@ -1,5 +1,125 @@
1 1  = **1 PIStudio** =
2 2  
3 +== V8.4.66_D23102001 ==
4 +
5 +* Official Website: [[Download Link>>Download Linkhttps://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.66.23102001.zip]]
6 +
7 +**Bugs fixed**
8 +
9 +PC Software
10 +
11 +1. In Omron free tag protocol, software crash during project compilation after tag import;
12 +1. In Omron free tag protocol, the project cannot be driven in package when compiling;
13 +1. 3102ig Camera Display object cannot be compiled;
14 +1. Error in the length limit of the folder edit box for the image display function of the bitmap object graphical interface;
15 +1. Error in the description of the expiration time for CreateInstallmentPwd tool: Modify from expiration time to next expiration time;
16 +1. Crash when the conversion tool converts the History XY Plot;
17 +1. It prompts wrong address when the conversion tool converts the Bit Alarm Record;
18 +1. The width-height ratio is wrong when the DiscRecord Chart object switches different resolutions;
19 +1. Error in compiling address of OMRON NX Ethernet/IP Protocol;
20 +1. Software crash and abnormal interface update when search address in address list;
21 +1. PI toolkit probably fails to connect for the first time;
22 +1. The data record is incomplete, and the table column width cannot be adjusted when using DataLogTool;
23 +1. Abnormal use of some tag addresses;
24 +1. Modified: Inconsistent color between meter value and scale;
25 +1. Error in tag array correspondence of tag protocol;
26 +1. Abnormal display when configuring the underlying screen;
27 +1. Abnormal compilation of 8070ig for using Camera Control object;
28 +1. Some pictures are lost after compilation;
29 +1. Abnormal display of bitmap of Switch object;
30 +1. Shortcut key configuration will also be deleted after deleting any main screen;
31 +1. HMI graphics status color cannot be changed;
32 +1. Modified: After the text is successfully set in Text Library, the language content is not grayed out when entering the settings again;
33 +
34 +== V8.2.95_D20220928 ==
35 +
36 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220928.zip]]
37 +
38 +(% class="wikigeneratedid" id="HBugsfixed" %)
39 +**Bugs fixed**
40 +
41 +(% class="wikigeneratedid" %)
42 +PC Software
43 +
44 +1. Optimize the function of saving project as;
45 +1. The word alarm configuration cannot be imported after being exported;
46 +1. The problem of abnormal resolution after png image editing and external import; 
47 +1. The password of project designer can be input into Chinese;
48 +1. The 8150ig model cannot be configured with camera search function;
49 +1. The probability of recipe setting cannot be saved;
50 +1. When simulating the "WECON" directory of C disk is adjusted to "HMIEmulation" directory;
51 +1. The problem that the position of text parts does not change after setting coordinates;
52 +1. The interface displays an redundant scroll bar when creating a new screen;
53 +1. The download tool only scans one of the network segments when there are multiple ip under the computer network card;
54 +1. The content of data records is abnormal and cannot be imported after being exported;
55 +1. The welcome interface opens the project and incorrectly prompts the project to be occupied;
56 +1. The installation path affects clicking offline simulation to pop up online simulation;
57 +1. The font size of the newly built-in screen 5004 is abnormal when switching to the size of 1920*1080;
58 +1. When the data record is stored in U disk and SD card, the size of the data record is not limited during compilation;
59 +1. The name of the newly created part in the right-click menu bar is consistent with the name in the part list;
60 +1. The problem that when compiling ie series projects, the memory size of the components of the picture exceeds the problem that no error is reported;
61 +1. When the U disk upgrade tool selects an invalid drive letter to generate a file, it does not normally prompt errors;
62 +1. The prompting wrong parameters when opening engineering parameters in the project of repairing vertical screen;
63 +
64 +(% class="wikigeneratedid" %)
65 +HMI Application
66 +
67 +1. Keyboard without "&" the question of symbols;
68 +1. The camera function on HMI V2.0 system will report error messages;
69 +1. The camera picture is still displayed after switching pictures on HMI V2.0 system;
70 +1. The project of Chinese character designer password cannot be simulated;
71 +1. The screenshots of printed parts are invalid when saved to SD card;
72 +1. The project downloaded by Ethernet cannot be uploaded normally;
73 +1. The debugging window moves the left and right scroll bars, and the upper and lower scroll bars will jump to the bottom;
74 +1. The manual APN of 4G setting cannot be saved;
75 +1. The system is upgraded to V2.0, the horizontal and vertical screens are abnormal;
76 +1. PI3043ie can't communicate with plc after upgrading;
77 +1. HMI2.0 background dynamic and static switch does not cache static IP;
78 +1. PI3070ig ftpserver can't access the service;
79 +1. V-BOX can't download PI3070N through download;
80 +1. The starting time will automatically change after the data record query setting interface pops up;
81 +1. The flow component displaying deviation in web pages;
82 +1. The alarm record header of switching language is not switched;
83 +1. The current alarm record will show the problem of historical alarm record;
84 +1. The camera uses power failure to save the address, and the camera state is not initialized after power failure and restart;
85 +1. The camera directly enters the account number, password and device serial number without enabling the search module;
86 +1. PI audio plays with sound and the volume is displayed as 0;
87 +1. When the hot spot name of the connection has single quotation marks, the network cannot recognize the problem;
88 +1. Add background U Disk upgrade updates the network configuration function (downloads the Ethernet parameters in the project parameters synchronously to the HMI
89 +1. The ig series can't use ezviz cloud function when using 4G Internet of Things card to surf the Internet;
90 +1. The screen saver cannot be exited on HMI V2.0 system;
91 +1. The communication is disconnected and cannot be reconnected after ig series VPN penetrates;
92 +1. Optimize the polling speed of VB trigger script;
93 +
94 +Drive the updated
95 +
96 +1. The abnormal communication caused by recipe reading;
97 +
98 +Driver Protocol
99 +
100 +1. Add Omron (NX/NJ) free label driver;
101 +
102 +**New functions**
103 +
104 +PC Software
105 +
106 +1. The picture compression function in the project parameters;
107 +1. Compatible switching models of PI8150ig (1920*1080 and 1280*720).
108 +1. The template picture with resolution of 1920*1080 of ig.
109 +1. ig series does not check the size limit of data record files.
110 +
111 +HMI Application
112 +
113 +1. The rotation function of switch components (only supported by HMI V2.0 system);
114 +1. Automatic rotation of rotation bitmap control and address control hiding function (only supported by HMI V2.0 system);
115 +1. Ftp service function (only supported by HMI V2.0 system);
116 +1. Ezviz cloud camera function (only supported by HMI V2.0 system);
117 +1. Lua curve custom component sliding bar function and draw 8 curves (only supported by HMI V2.0 system);
118 +1. Background language boot configuration (only supported by HMI V2.0 system);
119 +1. The function of modifying the header of data records (only supported by HMI V2.0 system);
120 +1. Historical trend style 6 and style 7 (only supported by HMI V2.0 system);
121 +1. PI8150ig (1920*1080rn) resolution;
122 +
3 3  == V8.2.62_D20220625 ==
4 4  
5 5  * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220625.zip]]
... ... @@ -265,15 +265,10 @@
265 265  
266 266  = **2 Levi2PI** =
267 267  
268 -== V4.3.8 ==
388 +== V4.5.8 ==
269 269  
270 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Wecon%20LEVI2PI.zip]]
271 -* Dropbox: [[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=Wecon+LEVI2PI.zip&subfolder_nav_tracking=1]]
390 +* [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Levi2PI.zip]]
272 272  
273 -== V4.5.6(Test Version) ==
274 -
275 -* Google Drive: [[Download Link>>https://drive.google.com/file/d/10Ay8dr7MK6CCpMIKEmKITG3DGipffJsI/view?usp=sharing]]
276 -
277 277  = **3 HMI Monitor System** =
278 278  
279 279  == VER: 20210317 ==