... ... @@ -1,1 +1,1 @@
1 -XWiki.joe
1 +XWiki.Hunter
Content
... ... @@ -1,13 +1,16 @@
1 -(((
1 +1. (((
2 2  = **1 PIStudio** =
3 3  )))
4 -
5 -(((
6 -== **V10.5.45.25102301(New modules: PI9000ig, RL, RH, WP)** ==
4 +1. (((
5 +== **V10.5.45.25102301(PI9000ig, RL, RH, WP)** ==
7 7  )))
8 8  
9 9  * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_10.5.zip]]
10 10  
10 +{{warning}}
11 +This test version software is only available for the following models: PI9000ig series, RL series, RH series, and WP series. For all other models, the released version is recommended as the first priority.
12 +{{/warning}}
13 +
11 11  (% class="wikigeneratedid" %)
12 12  **Bugs fixed**
13 13  
... ... @@ -15,43 +15,48 @@
15 15  1. Slow response of alarm record and address monitoring table, and stuck when opening the project;
16 16  1. LREAL data type cannot be read and written;
17 17  1. The overlapping screen cannot be set when the sub-screen is selected in screen;
18 -1. The encoding method options for string type data in Data record;
21 +1. Software crash caused by too many project tag and alarm points;
22 +1. The encoding method cannot be selected when recording string data;
19 19  1. Communication failure on Ethernet2 of HMI when using IP address from different Subnets for Ethernet1 and Ethernet2.
20 20  1. The addresses of X and Y are inconsistent in XY trend chart,;
25 +1. The address monitor is limited to one text address.
21 21  1. Object lock cannot be an index address;
22 -1. Lagging display of camera;
23 -1. Stuck on logo issue during IN, IE series upgrade;
27 +1. Choppy display from the camera;
28 +1. Logo display issue during IN, IE series upgrade;
24 24  1. The IN series HMI do not support the mouse style configuration;
25 25  1. Failure to download projects to IN series HMI ;
26 26  1. PDF prompts display abnormal;
27 27  1. CAN port configuration communication error;
28 28  1. When RH device uses 4K resolution, the fonts of message prompt, background, etc. are too small;
29 -1. The issue of translator multi-language;
34 +1. Fixed:The issue of translator multi-language;
30 30  1. Invalid address mapping;
31 31  1. The advanced configuration effect of device search, device management and cloud management download project not match the expected results;
32 -1. RH-00 communication configuration does not have ETH2 configuration;
37 +1. RH-00 communication port configuration does not have network port2 configuration ;
33 33  1. The ig model system keyboard is not working;
34 -1. The ig, RH series vertical screen mouse movement and touch optimized;
35 -1. 4.3-inch HMI vertical screen background display effect;
36 -1. Issue of Siemens S7-1200 DBS register reads and writes less than half, need to check the ”Read DWord” option;
37 -1. OPC UA Client reads and writes strings issue, if the new string is shorter than the old one, the end of the old string will be remained;
38 -1. If using too many element in recipe for JUNCAUTO protocol, the address will be clean and overwrite the data in low addresses;
39 -1. Write LX5V bit-in-word;
40 -1. OPC UA Client cannot connect to the server configured with authentication;
41 -1. OPC UA Client cannot reconnect normally after unplugging/plugging the network cable;
39 +1. Optimized: Remote cloud and pass-through;
40 +1. Optimized: Ig, RH series vertical screen mouse movement and touch;
41 +1. Optimization: 4.3-inch HMI vertical screen background display effect;
42 +1. Fixed:Issue of Siemens S7-1200 DBS register reads and writes less than half, need to check the ”Read Double Bytes”;
43 +1. The issue of OPCUA client reads and writes strings, if the new string is shorter than the old one, the end of the old string will be remained;
44 +1. When the recipe in the JUNCAUTO protocol is too large, the address will be clean and overwrite the data in low addresses;
45 +1. The issue with a bit in the LX5V word;
46 +1. OPCUA Client cannot connect to the server configured with authentication;
47 +1. OPCUA Client cannot reconnect normally after unplugging/plugging the network cable;
42 42  1. Changing communication methods in the background is invalid;
43 43  1. Set user permissions on the screen, but the register cannot jump to this screen;
44 -1. The issue of abnormal using indirect screen on sub-screen;
50 +1. The issue of abnormal using indirect pictures on sub-screen;
45 45  1. Abnormal display of the bar graph ;
46 46  1. The RH series cannot use the CODESYS protocol;
47 47  1. When the simulator's print object is set to screenshot mode, the screen cannot be switched after a screenshot.
48 -1. Operation records do not support text variable insert;
54 +1. Operation records do not support multi-variable;
49 49  1. Object or font shrinking when moving numeric object;
56 +1. The issue with quotation marks in recipe data after export/import on the 9000ig HMI;
57 +1. IN1072 cannot communicate with Siemens s7-200smart;
50 50  1. CODESYS V3 protocol cannot read the Unicode string of LX6C (WSTRING);
51 -1. The issue with the UNION type data in Omron;
59 +1. The issue with the union in Omron;
52 52  1. Communication failure after the end of VPN pass-through, ;
53 53  1. Communication failure between Keyence KV series protocol and 9000ig series;
54 -1. Gallery size limitation per screen for IN, IE and RH series;
62 +1. Optimized: Gallery size limit per screen for IN, IE and RH series;
55 55  1. Other issues;
56 56  
57 57  (% class="wikigeneratedid" %)
... ... @@ -144,6 +144,7 @@
144 144  (% class="wikigeneratedid" %)
145 145  **New drive**
146 146  
155 +
147 147  1. Winding Machine MODBUS RTU Winder;
148 148  1. KEYENCE EtherNet/IP (KV-8000);
149 149  1. KEYENCE EtherNet/IP (KV-X310);
... ... @@ -174,6 +174,7 @@
174 174  (% class="wikigeneratedid" %)
175 175  **New models**
176 176  
186 +
177 177  1. GB series: GB3041, GB3070, GB3101, GB8041, GB8070-H, GB8101;
178 178  1. ig series: PI9102ig, PI9121ig, PI9150ig, PI9151ig;
179 179  1. WP series: WP2070, WP2071, WP3070, WP3071;
... ... @@ -954,7 +954,7 @@
954 954  
955 955  == V8.2.95_D20220928 ==
956 956  
957 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.2.95.22092802.zip]]
967 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220928.zip]]
958 958  
959 959  (% class="wikigeneratedid" id="HBugsfixed" %)
960 960  **Bugs fixed**