Changes for page 3 Software
Last modified by Joe on 2026/03/27 09:17
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. joe1 +XWiki.Hunter - Content
-
... ... @@ -1,13 +1,16 @@ 1 -((( 1 +1. ((( 2 2 = **1 PIStudio** = 3 3 ))) 4 - 5 -((( 6 -== **V10.5.45.25102301(New modules: PI9000ig, RL, RH, WP)** == 4 +1. ((( 5 +== **V10.5.45.25102301(PI9000ig, RL, RH, WP)** == 7 7 ))) 8 8 9 9 * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_10.5.zip]] 10 10 10 +{{warning}} 11 +This test version software is only available for the following models: PI9000ig series, RL series, RH series, and WP series. For all other models, the released version is recommended as the first priority. 12 +{{/warning}} 13 + 11 11 (% class="wikigeneratedid" %) 12 12 **Bugs fixed** 13 13 ... ... @@ -15,43 +15,48 @@ 15 15 1. Slow response of alarm record and address monitoring table, and stuck when opening the project; 16 16 1. LREAL data type cannot be read and written; 17 17 1. The overlapping screen cannot be set when the sub-screen is selected in screen; 18 -1. The encoding method options for string type data in Data record; 21 +1. Software crash caused by too many project tag and alarm points; 22 +1. The encoding method cannot be selected when recording string data; 19 19 1. Communication failure on Ethernet2 of HMI when using IP address from different Subnets for Ethernet1 and Ethernet2. 20 20 1. The addresses of X and Y are inconsistent in XY trend chart,; 25 +1. The address monitor is limited to one text address. 21 21 1. Object lock cannot be an index address; 22 -1. Laggingdisplayof camera;23 -1. Stuckon logo issue during IN, IE series upgrade;27 +1. Choppy display from the camera; 28 +1. Logo display issue during IN, IE series upgrade; 24 24 1. The IN series HMI do not support the mouse style configuration; 25 25 1. Failure to download projects to IN series HMI ; 26 26 1. PDF prompts display abnormal; 27 27 1. CAN port configuration communication error; 28 28 1. When RH device uses 4K resolution, the fonts of message prompt, background, etc. are too small; 29 -1. The issue of translator multi-language; 34 +1. Fixed:The issue of translator multi-language; 30 30 1. Invalid address mapping; 31 31 1. The advanced configuration effect of device search, device management and cloud management download project not match the expected results; 32 -1. RH-00 communication configuration does not have ETH2 configuration;37 +1. RH-00 communication port configuration does not have network port2 configuration ; 33 33 1. The ig model system keyboard is not working; 34 -1. The ig, RH series vertical screen mouse movement and touch optimized; 35 -1. 4.3-inch HMI vertical screen background display effect; 36 -1. Issue of Siemens S7-1200 DBS register reads and writes less than half, need to check the ”Read DWord” option; 37 -1. OPC UA Client reads and writes strings issue, if the new string is shorter than the old one, the end of the old string will be remained; 38 -1. If using too many element in recipe for JUNCAUTO protocol, the address will be clean and overwrite the data in low addresses; 39 -1. Write LX5V bit-in-word; 40 -1. OPC UA Client cannot connect to the server configured with authentication; 41 -1. OPC UA Client cannot reconnect normally after unplugging/plugging the network cable; 39 +1. Optimized: Remote cloud and pass-through; 40 +1. Optimized: Ig, RH series vertical screen mouse movement and touch; 41 +1. Optimization: 4.3-inch HMI vertical screen background display effect; 42 +1. Fixed:Issue of Siemens S7-1200 DBS register reads and writes less than half, need to check the ”Read Double Bytes”; 43 +1. The issue of OPCUA client reads and writes strings, if the new string is shorter than the old one, the end of the old string will be remained; 44 +1. When the recipe in the JUNCAUTO protocol is too large, the address will be clean and overwrite the data in low addresses; 45 +1. The issue with a bit in the LX5V word; 46 +1. OPCUA Client cannot connect to the server configured with authentication; 47 +1. OPCUA Client cannot reconnect normally after unplugging/plugging the network cable; 42 42 1. Changing communication methods in the background is invalid; 43 43 1. Set user permissions on the screen, but the register cannot jump to this screen; 44 -1. The issue of abnormal using indirect screenon sub-screen;50 +1. The issue of abnormal using indirect pictures on sub-screen; 45 45 1. Abnormal display of the bar graph ; 46 46 1. The RH series cannot use the CODESYS protocol; 47 47 1. When the simulator's print object is set to screenshot mode, the screen cannot be switched after a screenshot. 48 -1. Operation records do not support t extvariableinsert;54 +1. Operation records do not support multi-variable; 49 49 1. Object or font shrinking when moving numeric object; 56 +1. The issue with quotation marks in recipe data after export/import on the 9000ig HMI; 57 +1. IN1072 cannot communicate with Siemens s7-200smart; 50 50 1. CODESYS V3 protocol cannot read the Unicode string of LX6C (WSTRING); 51 -1. The issue with the UNIONtype datain Omron;59 +1. The issue with the union in Omron; 52 52 1. Communication failure after the end of VPN pass-through, ; 53 53 1. Communication failure between Keyence KV series protocol and 9000ig series; 54 -1. Gallery size limit ationper screen for IN, IE and RH series;62 +1. Optimized: Gallery size limit per screen for IN, IE and RH series; 55 55 1. Other issues; 56 56 57 57 (% class="wikigeneratedid" %) ... ... @@ -144,6 +144,7 @@ 144 144 (% class="wikigeneratedid" %) 145 145 **New drive** 146 146 155 + 147 147 1. Winding Machine MODBUS RTU Winder; 148 148 1. KEYENCE EtherNet/IP (KV-8000); 149 149 1. KEYENCE EtherNet/IP (KV-X310); ... ... @@ -174,6 +174,7 @@ 174 174 (% class="wikigeneratedid" %) 175 175 **New models** 176 176 186 + 177 177 1. GB series: GB3041, GB3070, GB3101, GB8041, GB8070-H, GB8101; 178 178 1. ig series: PI9102ig, PI9121ig, PI9150ig, PI9151ig; 179 179 1. WP series: WP2070, WP2071, WP3070, WP3071; ... ... @@ -954,7 +954,7 @@ 954 954 955 955 == V8.2.95_D20220928 == 956 956 957 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio _8.2.95.22092802.zip]]967 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220928.zip]] 958 958 959 959 (% class="wikigeneratedid" id="HBugsfixed" %) 960 960 **Bugs fixed**