Changes for page 3 Software
Last modified by Jett on 2025/03/13 14:13
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.Hunter - Content
-
... ... @@ -1,285 +1,404 @@ 1 -= ** 1PIStudio** =1 += **PIStudio Release Build VER:R05R998_V8.2.62_D20220625** = 2 2 3 -== V8.2.62_D20220625 == 3 +(% class="wikigeneratedid" %) 4 +**Official Website:** 4 4 5 - *OfficialWebsite: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220625.zip]]6 -* Google Drive:[[Download Link>>https://drive.google.com/file/d/1kJuuzxjPj5mZmeazhGxrs3lGyMceqmYj/view?usp=sharing]]6 +(% class="wikigeneratedid" %) 7 +**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220625.zip]]** 7 7 8 -(% class="wikigeneratedid" id="HBugsfixed" %) 9 -**Bugs fixed** 9 +**Google Drive:** 10 10 11 -(% class="wikigeneratedid" id="HPCSoftware" %) 12 -PC Software 11 +**[[Download Link>>https://drive.google.com/file/d/1kJuuzxjPj5mZmeazhGxrs3lGyMceqmYj/view?usp=sharing]]** 13 13 14 -1. Cloud.xml does not exist in the project file of 8000 series and cannot access cloud; 15 -1. Lua prompting error when double click the project path of General series in Screen Management; 16 -1. The cursor moving into the area of background script will be disappeared; 17 -1. After the Lua script is changed, it is not compiled, and there is no prompt when clicking offline simulation; 18 -1. DLView fails to import excel files; 19 -1. There is an abnormality when creating image files into Udisk; 20 -1. Orientation options missing for Slide switch; 21 -1. COM3 Configuration missing for following models: 3070i-A and 3102i-A; 22 -1. When the download tool downloads the project, it does not prompt when the file does not exist; 23 -1. SD Card option missing for following models: 3070i-A, 3102i-A, 3070i-C, 3102i-C; 24 -1. Some of the same font size, font style is different when the font size is displayed abnormally; 25 -1. Optimize the built-in screen No.1008, add Time and Date objects; 26 -1. Optimize the remote download; 27 -1. Optimize the U disk upgrade function; 28 -1. Prompt when the downloads a file with a long path; 29 -1. The ig series vertical screen option is available now; 13 +== **Bugs Fixed** == 30 30 31 -(% class="wikigeneratedid" id="HHMIApplication" %) 32 -HMI Application 15 +=== **PC Software** === 33 33 34 -1. The i series freezes with HSW24 soft reboot; 35 -1. Debugging window cannot be closed on the ig monitoring page; 36 -1. Abnormal record time of ig Data record; 37 -1. The ig series abnormal ethernet communication; 38 -1. The register for network status HSW850 abnormal value; 39 -1. Lua we_bas_getstring script function execution error; 40 -1. The video title with English brackets cannot be played; 41 -1. Touch screen will lead to HMI freezes when keyboard input and cursor is enabled; 42 -1. Logo failed download for PI8150ig (before the firmware version 0313); 43 -1. After PI8000 series remote download PLC program, PLC cannot communicate; 44 -1. PI8000 series and ig series online V-NET but cannot remote control; 45 -1. Background Ethernet static IP configuration is not saved; 46 -1. The ig series WVPN remote pass through fails; 47 -1. Lua timer does not perform timing operations according to the interval; 17 +A) Cloud.xml does not exist in the project file of 8000 series and cannot access cloud; 48 48 49 -(% class="wikigeneratedid" id="HDriverProtocol" %) 50 -Driver Protocol 19 +B) Lua prompting error when double click the project path of General series in Screen Management; 51 51 52 -1. PI8000ig and Yudian sensor cannot communicate; 53 -1. Modify the name of the Wecon LX6V protocol, the old version project must be re-selected; 54 -1. The following serial port protocols have intermittent communication timeout issue: Siemens S7-200 smart, modbus, INVT, etc. 55 -1. Taian AP200 C register can not read the value 21 +C) The cursor moving into the area of background script will be disappeared; 56 56 57 -(% class="wikigeneratedid" id="HNewfunctions" %) 58 -**New functions** 23 +D) After the Lua script is changed, it is not compiled, and there is no prompt when clicking offline simulation; 59 59 60 -(% class="wikigeneratedid" id="HPCSoftware-1" %) 61 -PC Software 25 +E) DLView fails to import excel files; 62 62 63 -1. VB script customize naming function; 64 -1. PI Suite toolkit; 65 -1. System upgrade function; 66 -1. PIRecordUpload has added User permission function; 67 -1. Cloud function of 8000 and 9000 series; 27 +F) There is an abnormality when creating image files into Udisk; 68 68 69 -(% class="wikigeneratedid" id="HHMIApplication-1" %) 70 -HMI Application 29 +G) Orientation options missing for Slide switch; 71 71 31 +H) COM3 Configuration missing for following models: 3070i-A and 3102i-A; 32 + 33 +I) When the download tool downloads the project, it does not prompt when the file does not exist; 34 + 35 +J) SD Card option missing for following models: 3070i-A, 3102i-A, 3070i-C, 3102i-C; 36 + 37 +K) Some of the same font size, font style is different when the font size is displayed abnormally; 38 + 39 +L) Optimize the built-in screen No.1008, add Time and Date objects; 40 + 41 +M) Optimize the remote download; 42 + 43 +N) Optimize the U disk upgrade function; 44 + 45 +O) Prompt when the downloads a file with a long path; 46 + 47 +P) The ig series vertical screen option is available now; 48 + 49 +=== **HMI Application** === 50 + 51 +A) The i series freezes with HSW24 soft reboot; 52 + 53 +B) Debugging window cannot be closed on the ig monitoring page; 54 + 55 +C) Abnormal record time of ig Data record; 56 + 57 +D) The ig series abnormal ethernet communication; 58 + 59 +E)The register for network status HSW850 abnormal value; 60 + 61 +F) Lua we_bas_getstring script function execution error; 62 + 63 +G)The video title with English brackets cannot be played; 64 + 65 +H)Touch screen will lead to HMI freezes when keyboard input and cursor is enabled; 66 + 67 +I) Logo failed download for PI8150ig (before the firmware version 0313); 68 + 69 +J) After PI8000 series remote download PLC program, PLC cannot communicate; 70 + 71 +L) PI8000 series and ig series online V-NET but cannot remote control; 72 + 73 +M) Background Ethernet static IP configuration is not saved; 74 + 75 +N) The ig series WVPN remote pass through fails; 76 + 77 +O)Lua timer does not perform timing operations according to the interval; 78 + 79 +=== **Driver Protocol** === 80 + 81 +A) PI8000ig and Yudian sensor cannot communicate; 82 + 83 +B) Modify the name of the Wecon LX6V protocol, the old version project must be re-selected; 84 + 85 +C)The following serial port protocols have intermittent communication timeout issue: Siemens S7-200 smart, modbus, INVT, etc. 86 + 87 +D)Taian AP200 C register can not read the value 88 + 89 +== **New Functions Added** == 90 + 91 +=== **PC Software** === 92 + 93 +A) VB script customize naming function; 94 + 95 +B) PI Suite toolkit; 96 + 97 +C) System upgrade function; 98 + 99 +D) PIRecordUpload has added User permission function; 100 + 101 +E) Cloud function of 8000 and 9000 series; 102 + 103 +=== **HMI Application** === 104 + 72 72 The following function is only available for ig series: 73 73 74 -1. Slider of History trend chart can set the color and transparency; 75 -1. Continuous read and write addresses in Lua script; 76 -1. Built-in Lua extension module; 77 -1. Display network camera on HMI screen for 8150ig; 78 -1. Vertical Display; 79 -1. The priority settings of Cloud connection method from backstage configuration; 80 -1. Lua script supports https protocol now; 81 -1. UDisk Download project prohibit upload function; 82 -1. Lua script luasqlite operation; 83 -1. The following function is only available for i,ie,ig series and HMI+ system: 84 -1. All series remove the restriction of special machine code; 85 -1. Recipe 64-bit floating point number data format; 86 -1. UDisk Pop-Up function; 87 -1. Interconversion between GB2312 and UTF-8 encoding; 88 -1. UDisk download PLC multi-file function; 89 -1. Modifitable datetime prohibited; 90 -1. Color configuration of Line object; 107 +A) Slider of History trend chart can set the color and transparency; 91 91 92 -(% class="wikigeneratedid" id="HDriverProtocol-1" %) 93 -Driver Protocol 109 +B) Continuous read and write addresses in Lua script; 94 94 95 -1. Inovance H3U Ethernet; 96 -1. Rockwell micro850 Ethernet/IP Free Tags; 97 -1. Wecon LX6V Free Tags; 111 +C) Built-in Lua extension module; 98 98 99 -(% class="wikigeneratedid" id="HNewmodels" %) 100 -**New models** 113 +D) Display network camera on HMI screen for 8150ig; 101 101 102 -1. The i series: 3070i-A, 3102i-A, 3070i-C, 3102i-C, 3070i-2S, 3102i-2S 103 -1. The ie series: 3043ie-T 104 -1. The ig series: 8150ig 115 +E) Vertical Display; 105 105 106 -(% class="box infomessage" %) 107 -((( 117 +F) The priority settings of Cloud connection method from backstage configuration; 118 + 119 +G) Lua script supports https protocol now; 120 + 121 +H) UDisk Download project prohibit upload function; 122 + 123 +I) Lua script luasqlite operation; 124 + 125 +The following function is only available for i,ie,ig series and HMI+ system: 126 + 127 +J)All series remove the restriction of special machine code; 128 + 129 +K) Recipe 64-bit floating point number data format; 130 + 131 +L) UDisk Pop-Up function; 132 + 133 +M) Interconversion between GB2312 and UTF-8 encoding; 134 + 135 +N) UDisk download PLC multi-file function; 136 + 137 +O) Modifitable datetime prohibited; 138 + 139 +P) Color configuration of Line object; 140 + 141 +=== **Driver Protocol** === 142 + 143 +A Inovance H3U Ethernet; 144 + 145 +B Rockwell micro850 Ethernet/IP Free Tags; 146 + 147 +C Wecon LX6V Free Tags; 148 + 149 +== **New Models** == 150 + 151 +(1)The i series: 3070i-A, 3102i-A, 3070i-C, 3102i-C, 3070i-2S, 3102i-2S 152 + 153 +(2)The ie series: 3043ie-T 154 + 155 +(3)The ig series: 8150ig 156 + 108 108 ✎Note: 109 109 110 -* To use the new functions avaiable from new version, the project needs to be downloaded twice; 111 -* After the wifi module (version V1.1) of 3070ig is soft restarted, if the wifi is not recognized from background interface, please repower to recover it; 112 -))) 159 +1)To use the new functions avaiable from new version, the project needs to be downloaded twice; 113 113 114 - ==V7.2.198_D20211210==161 +2)After the wifi module (version V1.1) of 3070ig is soft restarted, if the wifi is not recognized from background interface, please repower to recover it; 115 115 116 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]] 117 -* Google Drive: [[Download Link>>https://drive.google.com/file/d/1lRfgoOwAs7lgL4b-ZdVUvE6itHWCpfd5/view?usp=sharing]] 163 += **PIStudio Release Build VER:R05R998_V7.2.198_D20211210** = 118 118 119 -(% class="wikigeneratedid" id="HBugsfixed-1"%)120 -** Bugsfixed**165 +(% class="wikigeneratedid" %) 166 +**Official Website:** 121 121 122 -(% class="wikigeneratedid" id="HPCSoftware-2"%)123 - PCSoftware168 +(% class="wikigeneratedid" %) 169 +**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]]** 124 124 125 -* Optimize the display style of text objects; 126 -* Optimize Lua script file size limitation to 512KB; 127 -* Optimize the import of text library and the limitation to 2000; 128 -* Protocol driver names standardized; 129 -* Font size is open to 512; 130 -* Lua script debugging window can be configured as enabled or not in Project Settings; 131 -* Optimize the font display of Runbar; 132 -* Optimized the forced backup function of project file, now you can click the cancel button to not backup; 133 -* Optimized and adjusted the default size of the password keyboard screen of newly-created projects; 134 -* Wrong display range of the History trend chart; 135 -* The font display of Drop-down List on PC is different from the actual screen; 136 -* Software crash caused by deleting the Address Library name; 137 -* General Series SMS protocol cannot be selected; 171 +**Google Drive:** 138 138 139 -(% class="wikigeneratedid" id="HHMIApplication-2" %) 140 -HMI Application 173 +**[[Download Link>>https://drive.google.com/file/d/1lRfgoOwAs7lgL4b-ZdVUvE6itHWCpfd5/view?usp=sharing]]** 141 141 142 -* Multi-Language display of text fonts; 143 -* Password keyboard input to display the plain text first and then the * sign; 144 -* Prompt display of Screen Lock for ie and ig; 145 -* Auto refresh of Data Record; 175 +== **Bugs Fixed** == 146 146 147 -(% class="wikigeneratedid" id="HDriverProtocol-2" %) 148 -Driver Protocol 177 +=== **PC Software** === 149 149 150 -* Communication cannot be performed after entering the backstage project; 151 -* Stuck screen problem caused by the protocol IEC60870-104 Client; 179 +A) Optimize the display style of text objects; 152 152 153 -(% class="wikigeneratedid" id="HNewfunctions-1" %) 154 -**New functions** 181 +B) Optimize Lua script file size limitation to 512KB; 155 155 156 -(% class="wikigeneratedid" id="HPCSoftware-3" %) 157 -PC Software 183 +C) Optimize the import of text library and the limitation to 2000; 158 158 159 -* New ie series model: 3035ie; 160 -* New ig series models: 3070ig, 3102ig; 161 -* License agreement for the software installation setup process; 162 -* Object Lock/Unlock function (Pushpin); 163 -* Lua Editor to highlight the same content of the selected text; 164 -* Font style settings of the Runbar and chart type objects; 165 -* Software installation package VC 2017 runtime library; 185 +D) Protocol driver names standardized; 166 166 167 -(% class="wikigeneratedid" id="HHMIApplication-3" %) 168 -HMI Application 187 +E) Font size is open to 512; 169 169 170 -* Recipe address discontinuous address setting; 171 -* Trim 0 display setting for numeric input; 172 -* Address Mapping continuous writing settings; 173 -* Screensaver function; 174 -* Multi-Link function (not supported by ie and ig series); 175 -* Traditional recipe function is only applicable to the LEVI2PI project that uses the Recipe function; 176 -* Disc Record Chart; 177 -* Lua script weather forecast function interfaces; 178 -* The ie series supports the barcode scanner; 189 +F) Lua script debugging window can be configured as enabled or not in Project Settings; 179 179 180 -(% class="wikigeneratedid" id="HDriverProtocol-3" %) 181 -Driver Protocol 191 +G) Optimize the font display of Runbar; 182 182 183 -* Koyo Modbus RTU; 184 -* ASK series; 185 -* Anda inverter; 186 -* Optimize the barcode scanner protocol; 193 +H) Optimized the forced backup function of project file, now you can click the cancel button to not backup; 187 187 188 - ==V7.1.117_D20210320==195 +I) Optimized and adjusted the default size of the password keyboard screen of newly-created projects; 189 189 190 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20210320.zip]] 191 -* Dropbox: [[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=PIStudio20210320.zip&subfolder_nav_tracking=1]] 197 +J) Wrong display range of the History trend chart; 192 192 193 -(% class="wikigeneratedid" id="HBugsfixed-2" %) 194 -**Bugs fixed** 199 +K) The font display of Drop-down List on PC is different from the actual screen; 195 195 196 -(% class="wikigeneratedid" id="HPCSoftware-4" %) 197 -PC Software 201 +L) Software crash caused by deleting the Address Library name; 198 198 199 -* Fix the crash problem of the software; 200 -* Renew the wiring diagram and pin definition diagram; 201 -* After the address is annotated, still able to communicate in Lua script; 202 -* Ethernet download optimization; 203 -* The project folder contains special language characters(except Chinese and English), errors in compiling Lua file and project, failed to download the project; 204 -* Use some fonts will cause software crash when compiling the project; 203 +M) General Series SMS protocol cannot be selected; 205 205 206 -(% class="wikigeneratedid" id="HHMIApplication-4" %) 207 -HMI Application 205 +=== **HMI Application** === 208 208 209 -* Occasionally occur stuck logo problem after enable the Index of Recipe function; 210 -* B) Frequently screen switching might have a little chance cause stuck problem if there exist many table objects on the screen; 211 -* There is a little chance cause the stuck problem if use the script; 212 -* The stuck problem if use User permission; 213 -* The stuck problem when Data record upload; 214 -* There is a little chance to jump to the test interface after restart; 215 -* After the backlight is off, there is a small chance that the screen will display abnormal; 216 -* Video play cause stuck problem of General series 9150; 217 -* When the HMI just turned on, Recipe Display on the main screen is displayed as NULL; 218 -* Optimize Lua built-in library and file read/write functions; 219 -* The label of the operation value in the Operation record is displayed abnormal; 220 -* The length of channel name for Data record exceeds 32 bytes, will cause failed recording; 221 -* After entering the installment password, restart immediately, would require entering the password again; 207 +A) Multi-Language display of text fonts; 222 222 223 -(% class="wikigeneratedid" id="HDriverProtocol-4" %) 224 -Driver Protocol 209 +B) Password keyboard input to display the plain text first and then the * sign; 225 225 226 -* Frequently screen switching and there are many external addresses on the screen, which might have a little chance cause a stuck problem; 227 -* Ethernet free tags may cause touch problem with no response; 228 -* Ethernet free tags occur error in compiling the project; 229 -* The input/output terminals of communication with MIKOM PLC are abnormal; 230 -* The reading information from scanner will not display if it exceeds 128 characters; 231 -* Failed to communicate with the OMRON NX/NJ PLC communication after power-on the screen and then power on the PLC. 232 -* When HMI+ is just turned on, the Ethernet communication prompts timeout; 233 -* When communicate with Siemens new protocol, will let the HMI stuck on LOGO screen; 211 +C) Prompt display of Screen Lock for ie and ig; 234 234 235 -(% class="wikigeneratedid" id="HNewfunctions-2" %) 236 -**New functions** 213 +D) Auto refresh of Data Record; 237 237 238 -(% class="wikigeneratedid" id="HPCSoftware-5" %) 239 -PC Software 215 +=== **Driver Protocol** === 240 240 241 -* New ie series: 3043ie, 3043ieS, 3070ie, 3102ie; 242 -* Industry purpose-designated models: ie series 3070ind, 3102ind, I series 3070ind-n; 243 -* Import and export function for Gallery file ( .blb or .plb format); 217 +A) Communication cannot be performed after entering the backstage project; 244 244 245 -(% class="wikigeneratedid" id="HHMIApplication-5" %) 246 -HMI Application 219 +B) Stuck screen problem caused by the protocol IEC60870-104 Client; 247 247 248 -* VNC LAN monitoring function ( require i series and PI+ models with Ethernet port and customized, the -O model in General series still use HMI Monitor System) 249 -* Resource report function to count the total memory used by the current screen; 250 -* Message prompt list (timeout , message , only available for ie series); 251 -* Timer and Trigger function in Lua script (only available for ie series); 252 -* Lua custom object, Lua table drawing, Lua curve drawing (only available for ie series); 253 -* Continuous input function of numeric and character object; 254 -* 4 Macro script functions involving file operations, FileCmpDir(), MyDeleteFile(), WriteWordToFile(), ReadWordFormFile(); 255 -* The backstage interface can upgrade PLC program to support 5VPLC program download (only available for 3000i and PI+ series); 221 +== **New Functions Added** == 256 256 257 -(% class="wikigeneratedid" id="HDriverProtocol-5" %) 258 -Driver Protocol 223 +=== **PC Software** === 259 259 260 - *KeyenceKVseries;225 +A) New ie series model: 3035ie; 261 261 262 - ==NotificationofPI+==227 +B) New ig series models: 3070ig, 3102ig; 263 263 264 - * [[DownloadLink>>url:https://drive.google.com/file/d/1UMb8YGc5lLSfoF_UHD5A4HwE_HKd-Qg7/view?usp=sharing]]229 +C) License agreement for the software installation setup process; 265 265 266 - =**2Levi2PI** =231 +D) Object Lock/Unlock function (Pushpin); 267 267 268 - ==V4.3.8==233 +E) Lua Editor to highlight the same content of the selected text; 269 269 270 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Wecon%20LEVI2PI.zip]] 271 -* Dropbox: [[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=Wecon+LEVI2PI.zip&subfolder_nav_tracking=1]] 235 +F) Font style settings of the Runbar and chart type objects; 272 272 273 - == V4.5.6(TestVersion)==237 +G) Software installation package VC 2017 runtime library; 274 274 275 -* Google Drive: [[Download Link>>https://drive.google.com/file/d/10Ay8dr7MK6CCpMIKEmKITG3DGipffJsI/view?usp=sharing]]239 +=== **HMI Application** === 276 276 277 - =**3HMI MonitorSystem** =241 +A) Recipe address discontinuous address setting; 278 278 279 - ==VER: 20210317==243 +B) Trim 0 display setting for numeric input; 280 280 281 - * Google Drive:[[Download Link>>https://drive.google.com/file/d/1RA3ui3jTCKtQTCLySjD4Qi7Ut58EYYD1/view?usp=sharing]]245 +C) Address Mapping continuous writing settings; 282 282 283 - = **4 Logo MakingTool** =247 +D) Screensaver function; 284 284 285 -* Google Drive: [[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]] 249 +E) Multi-Link function (not supported by ie and ig series); 250 + 251 +F) Traditional recipe function is only applicable to the LEVI2PI project that uses the Recipe function; 252 + 253 +G) Disc Record Chart; 254 + 255 +H) Lua script weather forecast function interfaces; 256 + 257 +I) The ie series supports the barcode scanner; 258 + 259 +=== **Driver Protocol** === 260 + 261 +A) Koyo Modbus RTU; 262 + 263 +B) ASK series; 264 + 265 +C) Anda inverter; 266 + 267 +D) Optimize the barcode scanner protocol; 268 + 269 += **PIStudio Release Build VER:R05R998_V7.1.117_D20210320** = 270 + 271 +**Official Website:** 272 + 273 +**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20210320.zip]]** 274 + 275 +**Dropbox:** 276 + 277 +**[[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=PIStudio20210320.zip&subfolder_nav_tracking=1]]** 278 + 279 +== **Bugs Fixed** == 280 + 281 +=== **PC Software** === 282 + 283 +A) Fix the crash problem of the software; 284 + 285 +B) Renew the wiring diagram and pin definition diagram; 286 + 287 +C) After the address is annotated, still able to communicate in Lua script; 288 + 289 +D) Ethernet download optimization; 290 + 291 +E) The project folder contains special language characters(except Chinese and English), errors in compiling Lua file and project, failed to download the project; 292 + 293 +F) Use some fonts will cause software crash when compiling the project; 294 + 295 +=== **HMI Application** === 296 + 297 +A) Occasionally occur stuck logo problem after enable the Index of Recipe function; 298 + 299 +B) Frequently screen switching might have a little chance cause stuck problem if there exist many table objects on the screen; 300 + 301 +C) There is a little chance cause the stuck problem if use the script; 302 + 303 +D) The stuck problem if use User permission; 304 + 305 +E) The stuck problem when Data record upload; 306 + 307 +F) There is a little chance to jump to the test interface after restart; 308 + 309 +G) After the backlight is off, there is a small chance that the screen will display abnormal; 310 + 311 +H) Video play cause stuck problem of General series 9150; 312 + 313 +I) When the HMI just turned on, Recipe Display on the main screen is displayed as NULL; 314 + 315 +J) Optimize Lua built-in library and file read/write functions; 316 + 317 +K) The label of the operation value in the Operation record is displayed abnormal; 318 + 319 +L) The length of channel name for Data record exceeds 32 bytes, will cause failed recording; 320 + 321 +M) After entering the installment password, restart immediately, would require entering the password again; 322 + 323 +=== **Driver Protocol** === 324 + 325 +A) Frequently screen switching and there are many external addresses on the screen, which might have a little chance cause a stuck problem; 326 + 327 +B) Ethernet free tags may cause touch problem with no response; 328 + 329 +C) Ethernet free tags occur error in compiling the project; 330 + 331 +D) The input/output terminals of communication with MIKOM PLC are abnormal; 332 + 333 +E) The reading information from scanner will not display if it exceeds 128 characters; 334 + 335 +F) Failed to communicate with the OMRON NX/NJ PLC communication after power-on the screen and then power on the PLC. 336 + 337 +G) When HMI+ is just turned on, the Ethernet communication prompts timeout; 338 + 339 +H) When communicate with Siemens new protocol, will let the HMI stuck on LOGO screen; 340 + 341 +== **New Functions Added** == 342 + 343 +=== **PC Software** === 344 + 345 +A) New ie series: 3043ie, 3043ieS, 3070ie, 3102ie; 346 + 347 +B) Industry purpose-designated models: ie series 3070ind, 3102ind, I series 3070ind-n; 348 + 349 +C) Import and export function for Gallery file ( .blb or .plb format); 350 + 351 +=== **HMI Application** === 352 + 353 +A) VNC LAN monitoring function ( require i series and PI+ models with Ethernet port and customized, the -O model in General series still use HMI Monitor System) 354 + 355 +B) Resource report function to count the total memory used by the current screen; 356 + 357 +C) Message prompt list (timeout , message , only available for ie series); 358 + 359 +D) Timer and Trigger function in Lua script (only available for ie series); 360 + 361 +E) Lua custom object, Lua table drawing, Lua curve drawing (only available for ie series); 362 + 363 +F) Continuous input function of numeric and character object; 364 + 365 +G) 4 Macro script functions involving file operations, FileCmpDir(), MyDeleteFile(), WriteWordToFile(), ReadWordFormFile(); 366 + 367 +H) The backstage interface can upgrade PLC program to support 5VPLC program download (only available for 3000i and PI+ series); 368 + 369 +== **Driver Protocol** == 370 + 371 +A) Keyence KV series; 372 + 373 +== **Notification of PI+** == 374 + 375 +**[[Download Link>>url:https://drive.google.com/file/d/1UMb8YGc5lLSfoF_UHD5A4HwE_HKd-Qg7/view?usp=sharing]]** 376 + 377 += **Levi2PI V4.3.8** = 378 + 379 +**Official Website:** 380 + 381 +**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/Wecon%20LEVI2PI.zip]]** 382 + 383 +**Dropbox:** 384 + 385 +**[[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=Wecon+LEVI2PI.zip&subfolder_nav_tracking=1]]** 386 + 387 += **Levi2PI V4.5.6(Test Version)** = 388 + 389 +**Google Drive** 390 + 391 +**[[Download Link>>https://drive.google.com/file/d/10Ay8dr7MK6CCpMIKEmKITG3DGipffJsI/view?usp=sharing]]** 392 + 393 += **HMI Monitor System20210317** = 394 + 395 +**Google Drive:** 396 + 397 +**[[Download Link>>https://drive.google.com/file/d/1RA3ui3jTCKtQTCLySjD4Qi7Ut58EYYD1/view?usp=sharing]]** 398 + 399 + 400 += **6 Logo Making Tool** = 401 + 402 +**Google Drive:** 403 + 404 +**[[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]**