Changes for page 3 Software
Last modified by Iris on 2026/07/27 10:58
From version 13.1
edited by Devin Chen
on 2026/04/25 09:46
on 2026/04/25 09:46
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. DevinChen1 +XWiki.Iris - Content
-
... ... @@ -1,9 +1,102 @@ 1 1 ((( 2 2 = **1 PIStudio** = 3 + 4 +== **V10.6.45.26070101** == 5 + 6 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/PIStudio_10.6.45.26070101.zip]] 7 + 8 +**Bugs fixed** 9 + 10 +1. Object -level password check option “Becomes the lowest level”; 11 +1. Static IP inaccessible after VPN pass-through; 12 +1. Multi-language switching not supported when exporting alarm record files; 13 +1. Some fonts displayed offset in remote screens; 14 +1. Indirect screens displayed abnormally in Remote monitoring; 15 +1. Some fonts displayed abnormally; 16 +1. Connecting Easy521 with INOVANCE H5U PLC via Ethernet protocol causes partial register addresses to fail to be read on the screen; 17 +1. RH-WG-LA unable to communicate with LX6C via WiFi; 18 +1. S7-1200 protocol string data issue; 19 +1. After a project is set to read-only mode, other projects cannot be opened afterward; 20 +1. Background function custom parameter display failure; 21 +1. Multi-layer nested indirect screens displayed abnormally; 22 +1. Indirect screens flickered when screen switching; 23 +1. Alarm Runbar failed to display blank spaces for alarms; 24 +1. Freetag communication indicator showed incorrect status; 25 +1. OPC UA client crash caused by repeated connection; 26 +1. Communication failure of SIEMENS AGLink protocol via Ethernet2; 27 +1. The KEYENCE KV-5000 protocol incomplete device address range. 28 +1. AB CompactLogix communication failure; 29 +1. Sub-screens not fully displayed when zoomed in; 30 +1. The popup of the function switch configuration interface shows coordinate position setting error; 31 +1. Inappropriate translation in some configuration screens; 32 +1. Modifying the hidden bit address of a text object will clear the text content; 33 +1. A beep still sounds when clicking after the drop-down list is hidden; 34 +1. Errors occur when a static IP is configured in the background without DNS setup; 35 +1. File list select-all copy-paste operation failed; 36 +1. Some special symbols displayed abnormally in Runbar messages; 37 +1. Meter object digital status failed to display normally; 38 +1. Alarm record display filter cumulative time and occurrence count sorting ineffective; 39 +1. Alarm record row space color setting ineffective; 40 +1. BACnet driver-related issues; 41 +1. H5U Ethernet protocol communication timeout problem; 42 +1. "Not created by this software" when opening projects in specific conditions; 43 +1. Bit alarm import anomaly in specific conditions; 44 +1. When the project has multiple templates, only one can be displayed in specific conditions; 45 +1. Private deployment URL configuration failure in specific conditions; 46 +1. No compilation error occurs after removing an address from the address library; 47 +1. Using the address list replacement function clears VB scripts; 48 +1. OMRON PLC communication timeout; 49 +1. Indirect screens flickered when screen switching; 50 +1. High delay in message prompt popups in specific conditions; 51 +1. Failed to connect to encrypted MQTT servers; 52 +1. MQTT publish error in Lua script; 53 +1. Communication failure between RH-WG-LA and LX6C via Wi-Fi. 54 +1. Communication anomaly in INOVANCE H5U PLC Ethernet protocol in specific conditions; 55 +1. SMS sending error in Lua script; 56 +1. Timeout occurs when continuously writing over 800 addresses to SCHNEIDER M221 PLC via Ethernet; 57 +1. Optimize loading speed of numeric input and text input controls; 58 +1. Optimize layout and style of background interface; 59 +1. Optimize loading speed of background WIFI configuration page; 60 +1. Optimize background prompt messages; 61 +1. Optimize communication efficiency of free tags; 62 +1. New calibration interface; 63 +1. Optimize click response speed of dropdown list; 64 +1. Optimize loading speed of alarm data during device startup; 65 +1. Other issues; 66 + 67 +**New functions** 68 + 69 +**PC software** 70 + 71 +1. Added: MQTT multi-server configuration; 72 +1. Add downloaded project path and update version No. for device management tool title; 73 +1. Europe 2.0 server option 74 + 75 +**HMI application** 76 + 77 +1. Display user storage space in background; 78 +1. Background online upgrade channel; 79 +1. Support European V2.0 server configuration in background; 80 +1. Register HSW2108 sets the scrollbar width of dropdown list; 81 +1. Lua interface for device name configuration; 82 +1. Register HSW893 controls synchronous/asynchronous mode of user permission between web terminal and touch screen terminal; 83 +1. Lua interface for selecting sound card of TTS voice playback; 84 +1. Registers HSW11829 and HSW11830 control keyboard mask transparency; 85 +1. Register HSW11831 controls enable/disable of long-press countdown animation effect; 86 +1. Optimize built-in virtual keyboard to support continuous text input after pressing backspace key; 87 + 88 +**New drive** 89 + 90 +1. KEYENCE KV-7000/8000 (Ethernet); 91 +1. Siemens S7-1200 Ethernet new protocol adds DBxDBLW four-word register; 92 +1. Siemens S7-200 Smart (Ethernet) V3/G2 drive; 93 +1. MIT Q Series CPU MELSEC PROTOCOL; 94 +1. MIT iQ-L Series CPU MELSEC PROTOCOL; 95 +1. MIT iQ-R Series CPU MELSEC PROTOCOL; 3 3 ))) 4 4 5 5 ((( 6 -== **V10.5.45.25102301(New modules: PI9000ig, RL, RH, WP)** == 99 +== **V10.5.45.25102301(New available modules: PI9000ig, RL, RH, WP)** == 7 7 ))) 8 8 9 9 * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_10.5.zip]]