Changes for page 3 Software

Last modified by Devin Chen on 2025/04/23 09:14

From version 16.1
edited by Mora Zhou
on 2023/10/27 09:23
Change comment: There is no comment for this version
To version 8.1
edited by Stone Wu
on 2022/07/29 15:51
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Mora
1 +XWiki.Stone
Content
... ... @@ -1,135 +1,17 @@
1 1  = **1 PIStudio** =
2 2  
3 -== V8.4.66_D23102001 ==
4 -
5 -* Official Website: [[Download Link>>Download Linkhttps://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.66.23102001.zip]]
6 -
7 -**Bugs fixed**
8 -
9 -PC Software
10 -
11 -1. In Omron free tag protocol, software crash during project compilation after tag import;
12 -1. In Omron free tag protocol, the project cannot be driven in package when compiling;
13 -1. 3102ig Camera Display object cannot be compiled;
14 -1. Error in the length limit of the folder edit box for the image display function of the bitmap object graphical interface;
15 -1. Error in the description of the expiration time for CreateInstallmentPwd tool: Modify from expiration time to next expiration time;
16 -1. Crash when the conversion tool converts the History XY Plot;
17 -1. It prompts wrong address when the conversion tool converts the Bit Alarm Record;
18 -1. The width-height ratio is wrong when the DiscRecord Chart object switches different resolutions;
19 -1. Error in compiling address of OMRON NX Ethernet/IP Protocol;
20 -1. Software crash and abnormal interface update when search address in address list;
21 -1. PI toolkit probably fails to connect for the first time;
22 -1. The data record is incomplete, and the table column width cannot be adjusted when using DataLogTool;
23 -1. Abnormal use of some tag addresses;
24 -1. Modified: Inconsistent color between meter value and scale;
25 -1. Error in tag array correspondence of tag protocol;
26 -1. Abnormal display when configuring the underlying screen;
27 -1. Abnormal compilation of 8070ig for using Camera Control object;
28 -1. Some pictures are lost after compilation;
29 -1. Abnormal display of bitmap of Switch object;
30 -1. Shortcut key configuration will also be deleted after deleting any main screen;
31 -1. HMI graphics status color cannot be changed;
32 -1. Modified: After the text is successfully set in Text Library, the language content is not grayed out when entering the settings again;
33 -
34 -== V8.2.95_D20220928 ==
35 -
36 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220928.zip]]
37 -
38 -(% class="wikigeneratedid" id="HBugsfixed" %)
39 -**Bugs fixed**
40 -
41 41  (% class="wikigeneratedid" %)
42 -PC Software
4 +== VER: R05R998_V8.2.62_D20220625 ==
43 43  
44 -1. Optimize the function of saving project as;
45 -1. The word alarm configuration cannot be imported after being exported;
46 -1. The problem of abnormal resolution after png image editing and external import; 
47 -1. The password of project designer can be input into Chinese;
48 -1. The 8150ig model cannot be configured with camera search function;
49 -1. The probability of recipe setting cannot be saved;
50 -1. When simulating the "WECON" directory of C disk is adjusted to "HMIEmulation" directory;
51 -1. The problem that the position of text parts does not change after setting coordinates;
52 -1. The interface displays an redundant scroll bar when creating a new screen;
53 -1. The download tool only scans one of the network segments when there are multiple ip under the computer network card;
54 -1. The content of data records is abnormal and cannot be imported after being exported;
55 -1. The welcome interface opens the project and incorrectly prompts the project to be occupied;
56 -1. The installation path affects clicking offline simulation to pop up online simulation;
57 -1. The font size of the newly built-in screen 5004 is abnormal when switching to the size of 1920*1080;
58 -1. When the data record is stored in U disk and SD card, the size of the data record is not limited during compilation;
59 -1. The name of the newly created part in the right-click menu bar is consistent with the name in the part list;
60 -1. The problem that when compiling ie series projects, the memory size of the components of the picture exceeds the problem that no error is reported;
61 -1. When the U disk upgrade tool selects an invalid drive letter to generate a file, it does not normally prompt errors;
62 -1. The prompting wrong parameters when opening engineering parameters in the project of repairing vertical screen;
63 -
64 64  (% class="wikigeneratedid" %)
65 -HMI Application
7 +**Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220625.zip]]**
66 66  
67 -1. Keyboard without "&" the question of symbols;
68 -1. The camera function on HMI V2.0 system will report error messages;
69 -1. The camera picture is still displayed after switching pictures on HMI V2.0 system;
70 -1. The project of Chinese character designer password cannot be simulated;
71 -1. The screenshots of printed parts are invalid when saved to SD card;
72 -1. The project downloaded by Ethernet cannot be uploaded normally;
73 -1. The debugging window moves the left and right scroll bars, and the upper and lower scroll bars will jump to the bottom;
74 -1. The manual APN of 4G setting cannot be saved;
75 -1. The system is upgraded to V2.0, the horizontal and vertical screens are abnormal;
76 -1. PI3043ie can't communicate with plc after upgrading;
77 -1. HMI2.0 background dynamic and static switch does not cache static IP;
78 -1. PI3070ig ftpserver can't access the service;
79 -1. V-BOX can't download PI3070N through download;
80 -1. The starting time will automatically change after the data record query setting interface pops up;
81 -1. The flow component displaying deviation in web pages;
82 -1. The alarm record header of switching language is not switched;
83 -1. The current alarm record will show the problem of historical alarm record;
84 -1. The camera uses power failure to save the address, and the camera state is not initialized after power failure and restart;
85 -1. The camera directly enters the account number, password and device serial number without enabling the search module;
86 -1. PI audio plays with sound and the volume is displayed as 0;
87 -1. When the hot spot name of the connection has single quotation marks, the network cannot recognize the problem;
88 -1. Add background U Disk upgrade updates the network configuration function (downloads the Ethernet parameters in the project parameters synchronously to the HMI
89 -1. The ig series can't use ezviz cloud function when using 4G Internet of Things card to surf the Internet;
90 -1. The screen saver cannot be exited on HMI V2.0 system;
91 -1. The communication is disconnected and cannot be reconnected after ig series VPN penetrates;
92 -1. Optimize the polling speed of VB trigger script;
9 +**Google Drive: [[Download Link>>https://drive.google.com/file/d/1kJuuzxjPj5mZmeazhGxrs3lGyMceqmYj/view?usp=sharing]]**
93 93  
94 -Drive the updated
11 +=== Bugs Fixed ===
95 95  
96 -1. The abnormal communication caused by recipe reading;
97 -
98 -Driver Protocol
99 -
100 -1. Add Omron (NX/NJ) free label driver;
101 -
102 -**New functions**
103 -
104 -PC Software
105 -
106 -1. The picture compression function in the project parameters;
107 -1. Compatible switching models of PI8150ig (1920*1080 and 1280*720).
108 -1. The template picture with resolution of 1920*1080 of ig.
109 -1. ig series does not check the size limit of data record files.
110 -
111 -HMI Application
112 -
113 -1. The rotation function of switch components (only supported by HMI V2.0 system);
114 -1. Automatic rotation of rotation bitmap control and address control hiding function (only supported by HMI V2.0 system);
115 -1. Ftp service function (only supported by HMI V2.0 system);
116 -1. Ezviz cloud camera function (only supported by HMI V2.0 system);
117 -1. Lua curve custom component sliding bar function and draw 8 curves (only supported by HMI V2.0 system);
118 -1. Background language boot configuration (only supported by HMI V2.0 system);
119 -1. The function of modifying the header of data records (only supported by HMI V2.0 system);
120 -1. Historical trend style 6 and style 7 (only supported by HMI V2.0 system);
121 -1. PI8150ig (1920*1080rn) resolution;
122 -
123 -== V8.2.62_D20220625 ==
124 -
125 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220625.zip]]
126 -* Google Drive: [[Download Link>>https://drive.google.com/file/d/1kJuuzxjPj5mZmeazhGxrs3lGyMceqmYj/view?usp=sharing]]
127 -
128 -(% class="wikigeneratedid" id="HBugsfixed" %)
129 -**Bugs fixed**
130 -
131 131  (% class="wikigeneratedid" id="HPCSoftware" %)
132 -PC Software
14 +**PC Software**
133 133  
134 134  1. Cloud.xml does not exist in the project file of 8000 series and cannot access cloud;
135 135  1. Lua prompting error when double click the project path of General series in Screen Management;
... ... @@ -149,7 +149,7 @@
149 149  1. The ig series vertical screen option is available now;
150 150  
151 151  (% class="wikigeneratedid" id="HHMIApplication" %)
152 -HMI Application
34 +**HMI Application**
153 153  
154 154  1. The i series freezes with HSW24 soft reboot;
155 155  1. Debugging window cannot be closed on the ig monitoring page;
... ... @@ -167,7 +167,7 @@
167 167  1. Lua timer does not perform timing operations according to the interval;
168 168  
169 169  (% class="wikigeneratedid" id="HDriverProtocol" %)
170 -Driver Protocol
52 +**Driver Protocol**
171 171  
172 172  1. PI8000ig and Yudian sensor cannot communicate;
173 173  1. Modify the name of the Wecon LX6V protocol, the old version project must be re-selected;
... ... @@ -174,11 +174,10 @@
174 174  1. The following serial port protocols have intermittent communication timeout issue: Siemens S7-200 smart, modbus, INVT, etc.
175 175  1. Taian AP200 C register can not read the value
176 176  
177 -(% class="wikigeneratedid" id="HNewfunctions" %)
178 -**New functions**
59 +=== New Functions Added ===
179 179  
180 180  (% class="wikigeneratedid" id="HPCSoftware-1" %)
181 -PC Software
62 +**PC Software**
182 182  
183 183  1. VB script customize naming function;
184 184  1. PI Suite toolkit;
... ... @@ -187,7 +187,7 @@
187 187  1. Cloud function of 8000 and 9000 series;
188 188  
189 189  (% class="wikigeneratedid" id="HHMIApplication-1" %)
190 -HMI Application
71 +**HMI Application**
191 191  
192 192  The following function is only available for ig series:
193 193  
... ... @@ -210,14 +210,13 @@
210 210  1. Color configuration of Line object;
211 211  
212 212  (% class="wikigeneratedid" id="HDriverProtocol-1" %)
213 -Driver Protocol
94 +**Driver Protocol**
214 214  
215 215  1. Inovance H3U Ethernet;
216 216  1. Rockwell micro850 Ethernet/IP Free Tags;
217 217  1. Wecon LX6V Free Tags;
218 218  
219 -(% class="wikigeneratedid" id="HNewmodels" %)
220 -**New models**
100 +=== New Models ===
221 221  
222 222  1. The i series: 3070i-A, 3102i-A, 3070i-C, 3102i-C, 3070i-2S, 3102i-2S
223 223  1. The ie series: 3043ie-T
... ... @@ -231,170 +231,243 @@
231 231  * After the wifi module (version V1.1) of 3070ig is soft restarted, if the wifi is not recognized from background interface, please repower to recover it;
232 232  )))
233 233  
234 -== V7.2.198_D20211210 ==
114 +== VER: R05R998_V7.2.198_D20211210 ==
235 235  
236 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]]
237 -* Google Drive: [[Download Link>>https://drive.google.com/file/d/1lRfgoOwAs7lgL4b-ZdVUvE6itHWCpfd5/view?usp=sharing]]
116 +(% class="wikigeneratedid" %)
117 +**Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]]**
238 238  
239 -(% class="wikigeneratedid" id="HBugsfixed-1" %)
240 -**Bugs fixed**
119 +**Google Drive: [[Download Link>>https://drive.google.com/file/d/1lRfgoOwAs7lgL4b-ZdVUvE6itHWCpfd5/view?usp=sharing]]**
241 241  
121 +=== Bugs Fixed ===
122 +
242 242  (% class="wikigeneratedid" id="HPCSoftware-2" %)
243 -PC Software
124 +**PC Software**
244 244  
245 -* Optimize the display style of text objects;
246 -* Optimize Lua script file size limitation to 512KB;
247 -* Optimize the import of text library and the limitation to 2000;
248 -* Protocol driver names standardized;
249 -* Font size is open to 512;
250 -* Lua script debugging window can be configured as enabled or not in Project Settings;
251 -* Optimize the font display of Runbar;
252 -* Optimized the forced backup function of project file, now you can click the cancel button to not backup;
253 -* Optimized and adjusted the default size of the password keyboard screen of newly-created projects;
254 -* Wrong display range of the History trend chart;
255 -* The font display of Drop-down List on PC is different from the actual screen;
256 -* Software crash caused by deleting the Address Library name;
257 -* General Series SMS protocol cannot be selected;
126 +A) Optimize the display style of text objects;
258 258  
128 +B) Optimize Lua script file size limitation to 512KB;
129 +
130 +C) Optimize the import of text library and the limitation to 2000;
131 +
132 +D) Protocol driver names standardized;
133 +
134 +E) Font size is open to 512;
135 +
136 +F) Lua script debugging window can be configured as enabled or not in Project Settings;
137 +
138 +G) Optimize the font display of Runbar;
139 +
140 +H) Optimized the forced backup function of project file, now you can click the cancel button to not backup;
141 +
142 +I) Optimized and adjusted the default size of the password keyboard screen of newly-created projects;
143 +
144 +J) Wrong display range of the History trend chart;
145 +
146 +K) The font display of Drop-down List on PC is different from the actual screen;
147 +
148 +L) Software crash caused by deleting the Address Library name;
149 +
150 +M) General Series SMS protocol cannot be selected;
151 +
259 259  (% class="wikigeneratedid" id="HHMIApplication-2" %)
260 -HMI Application
153 +**HMI Application**
261 261  
262 -* Multi-Language display of text fonts;
263 -* Password keyboard input to display the plain text first and then the * sign;
264 -* Prompt display of Screen Lock for ie and ig;
265 -* Auto refresh of Data Record;
155 +A) Multi-Language display of text fonts;
266 266  
157 +B) Password keyboard input to display the plain text first and then the * sign;
158 +
159 +C) Prompt display of Screen Lock for ie and ig;
160 +
161 +D) Auto refresh of Data Record;
162 +
267 267  (% class="wikigeneratedid" id="HDriverProtocol-2" %)
268 -Driver Protocol
164 +**Driver Protocol**
269 269  
270 -* Communication cannot be performed after entering the backstage project;
271 -* Stuck screen problem caused by the protocol IEC60870-104 Client;
166 +A) Communication cannot be performed after entering the backstage project;
272 272  
273 -(% class="wikigeneratedid" id="HNewfunctions-1" %)
274 -**New functions**
168 +B) Stuck screen problem caused by the protocol IEC60870-104 Client;
275 275  
170 +=== New Functions Added ===
171 +
276 276  (% class="wikigeneratedid" id="HPCSoftware-3" %)
277 -PC Software
173 +**PC Software**
278 278  
279 -* New ie series model: 3035ie;
280 -* New ig series models: 3070ig, 3102ig;
281 -* License agreement for the software installation setup process;
282 -* Object Lock/Unlock function (Pushpin);
283 -* Lua Editor to highlight the same content of the selected text;
284 -* Font style settings of the Runbar and chart type objects;
285 -* Software installation package VC 2017 runtime library;
175 +A) New ie series model: 3035ie;
286 286  
177 +B) New ig series models: 3070ig, 3102ig;
178 +
179 +C) License agreement for the software installation setup process;
180 +
181 +D) Object Lock/Unlock function (Pushpin);
182 +
183 +E) Lua Editor to highlight the same content of the selected text;
184 +
185 +F) Font style settings of the Runbar and chart type objects;
186 +
187 +G) Software installation package VC 2017 runtime library;
188 +
287 287  (% class="wikigeneratedid" id="HHMIApplication-3" %)
288 -HMI Application
190 +**HMI Application**
289 289  
290 -* Recipe address discontinuous address setting;
291 -* Trim 0 display setting for numeric input;
292 -* Address Mapping continuous writing settings;
293 -* Screensaver function;
294 -* Multi-Link function (not supported by ie and ig series);
295 -* Traditional recipe function is only applicable to the LEVI2PI project that uses the Recipe function;
296 -* Disc Record Chart;
297 -* Lua script weather forecast function interfaces;
298 -* The ie series supports the barcode scanner;
192 +A) Recipe address discontinuous address setting;
299 299  
194 +B) Trim 0 display setting for numeric input;
195 +
196 +C) Address Mapping continuous writing settings;
197 +
198 +D) Screensaver function;
199 +
200 +E) Multi-Link function (not supported by ie and ig series);
201 +
202 +F) Traditional recipe function is only applicable to the LEVI2PI project that uses the Recipe function;
203 +
204 +G) Disc Record Chart;
205 +
206 +H) Lua script weather forecast function interfaces;
207 +
208 +I) The ie series supports the barcode scanner;
209 +
300 300  (% class="wikigeneratedid" id="HDriverProtocol-3" %)
301 -Driver Protocol
211 +**Driver Protocol**
302 302  
303 -* Koyo Modbus RTU;
304 -* ASK series;
305 -* Anda inverter;
306 -* Optimize the barcode scanner protocol;
213 +A) Koyo Modbus RTU;
307 307  
308 -== V7.1.117_D20210320 ==
215 +B) ASK series;
309 309  
310 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20210320.zip]]
311 -* Dropbox: [[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=PIStudio20210320.zip&subfolder_nav_tracking=1]]
217 +C) Anda inverter;
312 312  
313 -(% class="wikigeneratedid" id="HBugsfixed-2" %)
314 -**Bugs fixed**
219 +D) Optimize the barcode scanner protocol;
315 315  
221 +== VER: R05R998_V7.1.117_D20210320 ==
222 +
223 +**Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20210320.zip]]**
224 +
225 +**Dropbox: [[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=PIStudio20210320.zip&subfolder_nav_tracking=1]]**
226 +
227 +=== Bugs Fixed ===
228 +
316 316  (% class="wikigeneratedid" id="HPCSoftware-4" %)
317 -PC Software
230 +**PC Software**
318 318  
319 -* Fix the crash problem of the software;
320 -* Renew the wiring diagram and pin definition diagram;
321 -* After the address is annotated, still able to communicate in Lua script;
322 -* Ethernet download optimization;
323 -* The project folder contains special language characters(except Chinese and English), errors in compiling Lua file and project, failed to download the project;
324 -* Use some fonts will cause software crash when compiling the project;
232 +A) Fix the crash problem of the software;
325 325  
234 +B) Renew the wiring diagram and pin definition diagram;
235 +
236 +C) After the address is annotated, still able to communicate in Lua script;
237 +
238 +D) Ethernet download optimization;
239 +
240 +E) The project folder contains special language characters(except Chinese and English), errors in compiling Lua file and project, failed to download the project;
241 +
242 +F) Use some fonts will cause software crash when compiling the project;
243 +
326 326  (% class="wikigeneratedid" id="HHMIApplication-4" %)
327 -HMI Application
245 +**HMI Application**
328 328  
329 -* Occasionally occur stuck logo problem after enable the Index of Recipe function;
330 -* B) Frequently screen switching might have a little chance cause stuck problem if there exist many table objects on the screen;
331 -* There is a little chance cause the stuck problem if use the script;
332 -* The stuck problem if use User permission;
333 -* The stuck problem when Data record upload;
334 -* There is a little chance to jump to the test interface after restart;
335 -* After the backlight is off, there is a small chance that the screen will display abnormal;
336 -* Video play cause stuck problem of General series 9150;
337 -* When the HMI just turned on, Recipe Display on the main screen is displayed as NULL;
338 -* Optimize Lua built-in library and file read/write functions;
339 -* The label of the operation value in the Operation record is displayed abnormal;
340 -* The length of channel name for Data record exceeds 32 bytes, will cause failed recording;
341 -* After entering the installment password, restart immediately, would require entering the password again;
247 +A) Occasionally occur stuck logo problem after enable the Index of Recipe function;
342 342  
249 +B) Frequently screen switching might have a little chance cause stuck problem if there exist many table objects on the screen;
250 +
251 +C) There is a little chance cause the stuck problem if use the script;
252 +
253 +D) The stuck problem if use User permission;
254 +
255 +E) The stuck problem when Data record upload;
256 +
257 +F) There is a little chance to jump to the test interface after restart;
258 +
259 +G) After the backlight is off, there is a small chance that the screen will display abnormal;
260 +
261 +H) Video play cause stuck problem of General series 9150;
262 +
263 +I) When the HMI just turned on, Recipe Display on the main screen is displayed as NULL;
264 +
265 +J) Optimize Lua built-in library and file read/write functions;
266 +
267 +K) The label of the operation value in the Operation record is displayed abnormal;
268 +
269 +L) The length of channel name for Data record exceeds 32 bytes, will cause failed recording;
270 +
271 +M) After entering the installment password, restart immediately, would require entering the password again;
272 +
343 343  (% class="wikigeneratedid" id="HDriverProtocol-4" %)
344 -Driver Protocol
274 +**Driver Protocol**
345 345  
346 -* Frequently screen switching and there are many external addresses on the screen, which might have a little chance cause a stuck problem; 
347 -* Ethernet free tags may cause touch problem with no response;
348 -* Ethernet free tags occur error in compiling the project;
349 -* The input/output terminals of communication with MIKOM PLC are abnormal;
350 -* The reading information from scanner will not display if it exceeds 128 characters;
351 -* Failed to communicate with the OMRON NX/NJ PLC communication after power-on the screen and then power on the PLC.
352 -* When HMI+ is just turned on, the Ethernet communication prompts timeout;
353 -* When communicate with Siemens new protocol, will let the HMI stuck on LOGO screen;
276 +A) Frequently screen switching and there are many external addresses on the screen, which might have a little chance cause a stuck problem; 
354 354  
355 -(% class="wikigeneratedid" id="HNewfunctions-2" %)
356 -**New functions**
278 +B) Ethernet free tags may cause touch problem with no response;
357 357  
280 +C) Ethernet free tags occur error in compiling the project;
281 +
282 +D) The input/output terminals of communication with MIKOM PLC are abnormal;
283 +
284 +E) The reading information from scanner will not display if it exceeds 128 characters;
285 +
286 +F) Failed to communicate with the OMRON NX/NJ PLC communication after power-on the screen and then power on the PLC.
287 +
288 +G) When HMI+ is just turned on, the Ethernet communication prompts timeout;
289 +
290 +H) When communicate with Siemens new protocol, will let the HMI stuck on LOGO screen;
291 +
292 +=== **New Functions Added** ===
293 +
358 358  (% class="wikigeneratedid" id="HPCSoftware-5" %)
359 -PC Software
295 +**PC Software**
360 360  
361 -* New ie series: 3043ie, 3043ieS, 3070ie, 3102ie;
362 -* Industry purpose-designated models: ie series 3070ind, 3102ind, I series 3070ind-n;
363 -* Import and export function for Gallery file ( .blb or .plb format);
297 +A) New ie series: 3043ie, 3043ieS, 3070ie, 3102ie;
364 364  
299 +B) Industry purpose-designated models: ie series 3070ind, 3102ind, I series 3070ind-n;
300 +
301 +C) Import and export function for Gallery file ( .blb or .plb format);
302 +
365 365  (% class="wikigeneratedid" id="HHMIApplication-5" %)
366 -HMI Application
304 +**HMI Application**
367 367  
368 -* VNC LAN monitoring function ( require i series and PI+ models with Ethernet port and customized, the -O model in General series still use HMI Monitor System)
369 -* Resource report function to count the total memory used by the current screen;
370 -* Message prompt list (timeout , message , only available for ie series);
371 -* Timer and Trigger function in Lua script (only available for ie series);
372 -* Lua custom object, Lua table drawing, Lua curve drawing (only available for ie series);
373 -* Continuous input function of numeric and character object;
374 -* 4 Macro script functions involving file operations, FileCmpDir(), MyDeleteFile(), WriteWordToFile(), ReadWordFormFile();
375 -* The backstage interface can upgrade PLC program to support 5VPLC program download (only available for 3000i and PI+ series);
306 +A) VNC LAN monitoring function ( require i series and PI+ models with Ethernet port and customized, the -O model in General series still use HMI Monitor System)
376 376  
308 +B) Resource report function to count the total memory used by the current screen;
309 +
310 +C) Message prompt list (timeout , message , only available for ie series);
311 +
312 +D) Timer and Trigger function in Lua script (only available for ie series);
313 +
314 +E) Lua custom object, Lua table drawing, Lua curve drawing (only available for ie series);
315 +
316 +F) Continuous input function of numeric and character object;
317 +
318 +G) 4 Macro script functions involving file operations, FileCmpDir(), MyDeleteFile(), WriteWordToFile(), ReadWordFormFile();
319 +
320 +H) The backstage interface can upgrade PLC program to support 5VPLC program download (only available for 3000i and PI+ series);
321 +
377 377  (% class="wikigeneratedid" id="HDriverProtocol-5" %)
378 -Driver Protocol
323 +**Driver Protocol**
379 379  
380 -* Keyence KV series;
325 +A) Keyence KV series;
381 381  
382 382  == Notification of PI+ ==
383 383  
384 -* [[Download Link>>url:https://drive.google.com/file/d/1UMb8YGc5lLSfoF_UHD5A4HwE_HKd-Qg7/view?usp=sharing]]
329 +**[[Download Link>>url:https://drive.google.com/file/d/1UMb8YGc5lLSfoF_UHD5A4HwE_HKd-Qg7/view?usp=sharing]]**
385 385  
386 386  = **2 Levi2PI** =
387 387  
388 -== V4.5.8 ==
333 +(% class="wikigeneratedid" %)
334 +== V4.3.8 ==
389 389  
390 -* [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Levi2PI.zip]]
336 +**Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Wecon%20LEVI2PI.zip]]**
391 391  
338 +**Dropbox: [[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=Wecon+LEVI2PI.zip&subfolder_nav_tracking=1]]**
339 +
340 +== V4.5.6(Test Version) ==
341 +
342 +**Google Drive: [[Download Link>>https://drive.google.com/file/d/10Ay8dr7MK6CCpMIKEmKITG3DGipffJsI/view?usp=sharing]]**
343 +
392 392  = **3 HMI Monitor System** =
393 393  
346 +(% class="wikigeneratedid" %)
394 394  == VER: 20210317 ==
395 395  
396 -* Google Drive: [[Download Link>>https://drive.google.com/file/d/1RA3ui3jTCKtQTCLySjD4Qi7Ut58EYYD1/view?usp=sharing]]
349 +**Google Drive: [[Download Link>>https://drive.google.com/file/d/1RA3ui3jTCKtQTCLySjD4Qi7Ut58EYYD1/view?usp=sharing]]**
397 397  
398 398  = **4 Logo Making Tool** =
399 399  
400 -* Google Drive: [[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]
353 +**Google Drive: [[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]**