Changes for page 3 Software

Last modified by Jett on 2025/03/13 14:13

From version 16.2
edited by Mora Zhou
on 2023/10/27 09:31
Change comment: There is no comment for this version
To version 7.1
edited by Hunter
on 2022/07/29 14:41
Change comment: Renamed from xwiki:PIStudio.5 Software.WebHome

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -3 Software
1 +5 Software
Parent
... ... @@ -1,1 +1,1 @@
1 -PIStudio.Download.WebHome
1 +PIStudio.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Mora
1 +XWiki.Hunter
Content
... ... @@ -1,454 +1,404 @@
1 -= **1 PIStudio** =
1 += **PIStudio Release Build VER:R05R998_V8.2.62_D20220625** =
2 2  
3 -== V8.4.66_D23102001 ==
3 +(% class="wikigeneratedid" %)
4 +**Official Website:**
4 4  
5 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.66.23102001.zip]]
6 +(% class="wikigeneratedid" %)
7 +**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220625.zip]]**
6 6  
7 -**Bugs fixed**
9 +**Google Drive:**
8 8  
9 -PC Software
11 +**[[Download Link>>https://drive.google.com/file/d/1kJuuzxjPj5mZmeazhGxrs3lGyMceqmYj/view?usp=sharing]]**
10 10  
11 -1. In Omron free tag protocol, software crash during project compilation after tag import;
12 -1. In Omron free tag protocol, the project cannot be driven in package when compiling;
13 -1. 3102ig Camera Display object cannot be compiled;
14 -1. Error in the length limit of the folder edit box for the image display function of the bitmap object graphical interface;
15 -1. Error in the description of the expiration time for CreateInstallmentPwd tool: Modify from expiration time to next expiration time;
16 -1. Crash when the conversion tool converts the History XY Plot;
17 -1. It prompts wrong address when the conversion tool converts the Bit Alarm Record;
18 -1. The width-height ratio is wrong when the DiscRecord Chart object switches different resolutions;
19 -1. Error in compiling address of OMRON NX Ethernet/IP Protocol;
20 -1. Software crash and abnormal interface update when search address in address list;
21 -1. PI toolkit probably fails to connect for the first time;
22 -1. The data record is incomplete, and the table column width cannot be adjusted when using DataLogTool;
23 -1. Abnormal use of some tag addresses;
24 -1. Modified: Inconsistent color between meter value and scale;
25 -1. Error in tag array correspondence of tag protocol;
26 -1. Abnormal display when configuring the underlying screen;
27 -1. Abnormal compilation of 8070ig for using Camera Control object;
28 -1. Some pictures are lost after compilation;
29 -1. Abnormal display of bitmap of Switch object;
30 -1. Shortcut key configuration will also be deleted after deleting any main screen;
31 -1. HMI graphics status color cannot be changed;
32 -1. Modified: After the text is successfully set in Text Library, the language content is not grayed out when entering the settings again;
33 -1. (((
34 -Use “Save as” once, it can open the screen file normally. But use “Save as” again to rename it with the same name, and then the folder will be empty.
35 -)))
36 -1. (((
37 -There is no limit to the size of Custom object;
38 -)))
39 -1. (((
40 -Sub-screen jumps to the next/previous screen (Without common screen), and right-click to switch to the target screen which is not grayed out;
41 -)))
42 -1. (((
43 -HMI crash caused by abnormal data modification of objects;
44 -)))
45 -1. (((
46 -“More" without Spanish translation in TLS/SSL in MQTT;
47 -)))
48 -1. (((
49 -Translation of some objects in right-click is different from that of object bar;
50 -)))
51 -1. (((
52 -After importing HMI project pictures, offline simulation does not display the imported pictures;
53 -)))
54 -1. (((
55 -After modifying the function switch, it will cause communication failure;
56 -)))
57 -1. (((
58 -Download prompt garbled in Win7;
59 -)))
60 -1. (((
61 -The wiring diagram of 8043ig and 3043ig communication is inconsistent with the actual situation;
62 -)))
63 -1. (((
64 -Neutral project simulation crash and download will be stuck and cannot click;
65 -)))
66 -1. (((
67 -Draw objects exceeds boundaries after modifying coordinates to a prompted maximum value;
68 -)))
69 -1. (((
70 - Unable to use lua object directly when not enabling Lua Script;
71 -)))
72 -1. (((
73 -The error prompt of communication port configuration, namely there is spare %s;
74 -)))
75 -1. (((
76 -Language selection of data recording channel does not save;
77 -)))
78 -1. (((
79 -The project file is deleted at compile caused by setting a special path for “Save as”;
80 -)))
81 -1. (((
82 -The preview of Table object does not follow the modification of the number of rows and columns to change;
83 -)))
84 -1. (((
85 -Modifying the coordinates and sizes of Arc object through parameters will cause the inconsistency between graphics and actual situation;
86 -)))
13 +== **Bugs Fixed** ==
87 87  
88 -== V8.2.95_D20220928 ==
15 +=== **PC Software** ===
89 89  
90 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220928.zip]]
17 +A) Cloud.xml does not exist in the project file of 8000 series and cannot access cloud;
91 91  
92 -(% class="wikigeneratedid" id="HBugsfixed" %)
93 -**Bugs fixed**
19 +B) Lua prompting error when double click the project path of General series in Screen Management;
94 94  
95 -(% class="wikigeneratedid" %)
96 -PC Software
21 +C) The cursor moving into the area of background script will be disappeared;
97 97  
98 -1. Optimize the function of saving project as;
99 -1. The word alarm configuration cannot be imported after being exported;
100 -1. The problem of abnormal resolution after png image editing and external import; 
101 -1. The password of project designer can be input into Chinese;
102 -1. The 8150ig model cannot be configured with camera search function;
103 -1. The probability of recipe setting cannot be saved;
104 -1. When simulating the "WECON" directory of C disk is adjusted to "HMIEmulation" directory;
105 -1. The problem that the position of text parts does not change after setting coordinates;
106 -1. The interface displays an redundant scroll bar when creating a new screen;
107 -1. The download tool only scans one of the network segments when there are multiple ip under the computer network card;
108 -1. The content of data records is abnormal and cannot be imported after being exported;
109 -1. The welcome interface opens the project and incorrectly prompts the project to be occupied;
110 -1. The installation path affects clicking offline simulation to pop up online simulation;
111 -1. The font size of the newly built-in screen 5004 is abnormal when switching to the size of 1920*1080;
112 -1. When the data record is stored in U disk and SD card, the size of the data record is not limited during compilation;
113 -1. The name of the newly created part in the right-click menu bar is consistent with the name in the part list;
114 -1. The problem that when compiling ie series projects, the memory size of the components of the picture exceeds the problem that no error is reported;
115 -1. When the U disk upgrade tool selects an invalid drive letter to generate a file, it does not normally prompt errors;
116 -1. The prompting wrong parameters when opening engineering parameters in the project of repairing vertical screen;
23 +D) After the Lua script is changed, it is not compiled, and there is no prompt when clicking offline simulation;
117 117  
118 -(% class="wikigeneratedid" %)
119 -HMI Application
25 +E) DLView fails to import excel files;
120 120  
121 -1. Keyboard without "&" the question of symbols;
122 -1. The camera function on HMI V2.0 system will report error messages;
123 -1. The camera picture is still displayed after switching pictures on HMI V2.0 system;
124 -1. The project of Chinese character designer password cannot be simulated;
125 -1. The screenshots of printed parts are invalid when saved to SD card;
126 -1. The project downloaded by Ethernet cannot be uploaded normally;
127 -1. The debugging window moves the left and right scroll bars, and the upper and lower scroll bars will jump to the bottom;
128 -1. The manual APN of 4G setting cannot be saved;
129 -1. The system is upgraded to V2.0, the horizontal and vertical screens are abnormal;
130 -1. PI3043ie can't communicate with plc after upgrading;
131 -1. HMI2.0 background dynamic and static switch does not cache static IP;
132 -1. PI3070ig ftpserver can't access the service;
133 -1. V-BOX can't download PI3070N through download;
134 -1. The starting time will automatically change after the data record query setting interface pops up;
135 -1. The flow component displaying deviation in web pages;
136 -1. The alarm record header of switching language is not switched;
137 -1. The current alarm record will show the problem of historical alarm record;
138 -1. The camera uses power failure to save the address, and the camera state is not initialized after power failure and restart;
139 -1. The camera directly enters the account number, password and device serial number without enabling the search module;
140 -1. PI audio plays with sound and the volume is displayed as 0;
141 -1. When the hot spot name of the connection has single quotation marks, the network cannot recognize the problem;
142 -1. Add background U Disk upgrade updates the network configuration function (downloads the Ethernet parameters in the project parameters synchronously to the HMI
143 -1. The ig series can't use ezviz cloud function when using 4G Internet of Things card to surf the Internet;
144 -1. The screen saver cannot be exited on HMI V2.0 system;
145 -1. The communication is disconnected and cannot be reconnected after ig series VPN penetrates;
146 -1. Optimize the polling speed of VB trigger script;
27 +F) There is an abnormality when creating image files into Udisk;
147 147  
148 -Drive the updated
29 +G) Orientation options missing for Slide switch;
149 149  
150 -1. The abnormal communication caused by recipe reading;
31 +H) COM3 Configuration missing for following models: 3070i-A and 3102i-A;
151 151  
152 -Driver Protocol
33 +I) When the download tool downloads the project, it does not prompt when the file does not exist;
153 153  
154 -1. Add Omron (NX/NJ) free label driver;
35 +J) SD Card option missing for following models: 3070i-A, 3102i-A, 3070i-C, 3102i-C;
155 155  
156 -**New functions**
37 +K) Some of the same font size, font style is different when the font size is displayed abnormally;
157 157  
158 -PC Software
39 +L) Optimize the built-in screen No.1008, add Time and Date objects;
159 159  
160 -1. The picture compression function in the project parameters;
161 -1. Compatible switching models of PI8150ig (1920*1080 and 1280*720).
162 -1. The template picture with resolution of 1920*1080 of ig.
163 -1. ig series does not check the size limit of data record files.
41 +M) Optimize the remote download;
164 164  
165 -HMI Application
43 +N) Optimize the U disk upgrade function;
166 166  
167 -1. The rotation function of switch components (only supported by HMI V2.0 system);
168 -1. Automatic rotation of rotation bitmap control and address control hiding function (only supported by HMI V2.0 system);
169 -1. Ftp service function (only supported by HMI V2.0 system);
170 -1. Ezviz cloud camera function (only supported by HMI V2.0 system);
171 -1. Lua curve custom component sliding bar function and draw 8 curves (only supported by HMI V2.0 system);
172 -1. Background language boot configuration (only supported by HMI V2.0 system);
173 -1. The function of modifying the header of data records (only supported by HMI V2.0 system);
174 -1. Historical trend style 6 and style 7 (only supported by HMI V2.0 system);
175 -1. PI8150ig (1920*1080rn) resolution;
45 +O) Prompt when the downloads a file with a long path;
176 176  
177 -== V8.2.62_D20220625 ==
47 +P) The ig series vertical screen option is available now;
178 178  
179 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220625.zip]]
180 -* Google Drive: [[Download Link>>https://drive.google.com/file/d/1kJuuzxjPj5mZmeazhGxrs3lGyMceqmYj/view?usp=sharing]]
49 +=== **HMI Application** ===
181 181  
182 -(% class="wikigeneratedid" id="HBugsfixed" %)
183 -**Bugs fixed**
51 +A) The i series freezes with HSW24 soft reboot;
184 184  
185 -(% class="wikigeneratedid" id="HPCSoftware" %)
186 -PC Software
53 +B) Debugging window cannot be closed on the ig monitoring page;
187 187  
188 -1. Cloud.xml does not exist in the project file of 8000 series and cannot access cloud;
189 -1. Lua prompting error when double click the project path of General series in Screen Management;
190 -1. The cursor moving into the area of background script will be disappeared;
191 -1. After the Lua script is changed, it is not compiled, and there is no prompt when clicking offline simulation;
192 -1. DLView fails to import excel files;
193 -1. There is an abnormality when creating image files into Udisk;
194 -1. Orientation options missing for Slide switch;
195 -1. COM3 Configuration missing for following models: 3070i-A and 3102i-A;
196 -1. When the download tool downloads the project, it does not prompt when the file does not exist;
197 -1. SD Card option missing for following models: 3070i-A, 3102i-A, 3070i-C, 3102i-C;
198 -1. Some of the same font size, font style is different when the font size is displayed abnormally;
199 -1. Optimize the built-in screen No.1008, add Time and Date objects;
200 -1. Optimize the remote download;
201 -1. Optimize the U disk upgrade function;
202 -1. Prompt when the downloads a file with a long path;
203 -1. The ig series vertical screen option is available now;
55 +C) Abnormal record time of ig Data record;
204 204  
205 -(% class="wikigeneratedid" id="HHMIApplication" %)
206 -HMI Application
57 +D) The ig series abnormal ethernet communication;
207 207  
208 -1. The i series freezes with HSW24 soft reboot;
209 -1. Debugging window cannot be closed on the ig monitoring page;
210 -1. Abnormal record time of ig Data record;
211 -1. The ig series abnormal ethernet communication;
212 -1. The register for network status HSW850 abnormal value;
213 -1. Lua we_bas_getstring script function execution error;
214 -1. The video title with English brackets cannot be played;
215 -1. Touch screen will lead to HMI freezes when keyboard input and cursor is enabled;
216 -1. Logo failed download for PI8150ig (before the firmware version 0313);
217 -1. After PI8000 series remote download PLC program, PLC cannot communicate;
218 -1. PI8000 series and ig series online V-NET but cannot remote control;
219 -1. Background Ethernet static IP configuration is not saved;
220 -1. The ig series WVPN remote pass through fails;
221 -1. Lua timer does not perform timing operations according to the interval;
59 +E)The register for network status HSW850 abnormal value;
222 222  
223 -(% class="wikigeneratedid" id="HDriverProtocol" %)
224 -Driver Protocol
61 +F) Lua we_bas_getstring script function execution error;
225 225  
226 -1. PI8000ig and Yudian sensor cannot communicate;
227 -1. Modify the name of the Wecon LX6V protocol, the old version project must be re-selected;
228 -1. The following serial port protocols have intermittent communication timeout issue: Siemens S7-200 smart, modbus, INVT, etc.
229 -1. Taian AP200 C register can not read the value
63 +G)The video title with English brackets cannot be played;
230 230  
231 -(% class="wikigeneratedid" id="HNewfunctions" %)
232 -**New functions**
65 +H)Touch screen will lead to HMI freezes when keyboard input and cursor is enabled;
233 233  
234 -(% class="wikigeneratedid" id="HPCSoftware-1" %)
235 -PC Software
67 +I) Logo failed download for PI8150ig (before the firmware version 0313);
236 236  
237 -1. VB script customize naming function;
238 -1. PI Suite toolkit;
239 -1. System upgrade function;
240 -1. PIRecordUpload has added User permission function;
241 -1. Cloud function of 8000 and 9000 series;
69 +J) After PI8000 series remote download PLC program, PLC cannot communicate;
242 242  
243 -(% class="wikigeneratedid" id="HHMIApplication-1" %)
244 -HMI Application
71 +L) PI8000 series and ig series online V-NET but cannot remote control;
245 245  
73 +M) Background Ethernet static IP configuration is not saved;
74 +
75 +N) The ig series WVPN remote pass through fails;
76 +
77 +O)Lua timer does not perform timing operations according to the interval;
78 +
79 +=== **Driver Protocol** ===
80 +
81 +A) PI8000ig and Yudian sensor cannot communicate;
82 +
83 +B) Modify the name of the Wecon LX6V protocol, the old version project must be re-selected;
84 +
85 +C)The following serial port protocols have intermittent communication timeout issue: Siemens S7-200 smart, modbus, INVT, etc.
86 +
87 +D)Taian AP200 C register can not read the value
88 +
89 +== **New Functions Added** ==
90 +
91 +=== **PC Software** ===
92 +
93 +A) VB script customize naming function;
94 +
95 +B) PI Suite toolkit;
96 +
97 +C) System upgrade function;
98 +
99 +D) PIRecordUpload has added User permission function;
100 +
101 +E) Cloud function of 8000 and 9000 series;
102 +
103 +=== **HMI Application** ===
104 +
246 246  The following function is only available for ig series:
247 247  
248 -1. Slider of History trend chart can set the color and transparency;
249 -1. Continuous read and write addresses in Lua script;
250 -1. Built-in Lua extension module;
251 -1. Display network camera on HMI screen for 8150ig;
252 -1. Vertical Display;
253 -1. The priority settings of Cloud connection method from backstage configuration;
254 -1. Lua script supports https protocol now;
255 -1. UDisk Download project prohibit upload function;
256 -1. Lua script luasqlite operation;
257 -1. The following function is only available for i,ie,ig series and HMI+ system:
258 -1. All series remove the restriction of special machine code;
259 -1. Recipe 64-bit floating point number data format;
260 -1. UDisk Pop-Up function;
261 -1. Interconversion between GB2312 and UTF-8 encoding;
262 -1. UDisk download PLC multi-file function;
263 -1. Modifitable datetime prohibited;
264 -1. Color configuration of Line object;
107 +A) Slider of History trend chart can set the color and transparency;
265 265  
266 -(% class="wikigeneratedid" id="HDriverProtocol-1" %)
267 -Driver Protocol
109 +B) Continuous read and write addresses in Lua script;
268 268  
269 -1. Inovance H3U Ethernet;
270 -1. Rockwell micro850 Ethernet/IP Free Tags;
271 -1. Wecon LX6V Free Tags;
111 +C) Built-in Lua extension module;
272 272  
273 -(% class="wikigeneratedid" id="HNewmodels" %)
274 -**New models**
113 +D) Display network camera on HMI screen for 8150ig;
275 275  
276 -1. The i series: 3070i-A, 3102i-A, 3070i-C, 3102i-C, 3070i-2S, 3102i-2S
277 -1. The ie series: 3043ie-T
278 -1. The ig series: 8150ig
115 +E) Vertical Display;
279 279  
280 -(% class="box infomessage" %)
281 -(((
117 +F) The priority settings of Cloud connection method from backstage configuration;
118 +
119 +G) Lua script supports https protocol now;
120 +
121 +H) UDisk Download project prohibit upload function;
122 +
123 +I) Lua script luasqlite operation;
124 +
125 +The following function is only available for i,ie,ig series and HMI+ system:
126 +
127 +J)All series remove the restriction of special machine code;
128 +
129 +K) Recipe 64-bit floating point number data format;
130 +
131 +L) UDisk Pop-Up function;
132 +
133 +M) Interconversion between GB2312 and UTF-8 encoding;
134 +
135 +N) UDisk download PLC multi-file function;
136 +
137 +O) Modifitable datetime prohibited;
138 +
139 +P) Color configuration of Line object;
140 +
141 +=== **Driver Protocol** ===
142 +
143 +A Inovance H3U Ethernet;
144 +
145 +B Rockwell micro850 Ethernet/IP Free Tags;
146 +
147 +C Wecon LX6V Free Tags;
148 +
149 +== **New Models** ==
150 +
151 +(1)The i series: 3070i-A, 3102i-A, 3070i-C, 3102i-C, 3070i-2S, 3102i-2S
152 +
153 +(2)The ie series: 3043ie-T
154 +
155 +(3)The ig series: 8150ig
156 +
282 282  ✎Note:
283 283  
284 -* To use the new functions avaiable from new version, the project needs to be downloaded twice;
285 -* After the wifi module (version V1.1) of 3070ig is soft restarted, if the wifi is not recognized from background interface, please repower to recover it;
286 -)))
159 +1)To use the new functions avaiable from new version, the project needs to be downloaded twice;
287 287  
288 -== V7.2.198_D20211210 ==
161 +2)After the wifi module (version V1.1) of 3070ig is soft restarted, if the wifi is not recognized from background interface, please repower to recover it;
289 289  
290 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]]
291 -* Google Drive: [[Download Link>>https://drive.google.com/file/d/1lRfgoOwAs7lgL4b-ZdVUvE6itHWCpfd5/view?usp=sharing]]
163 += **PIStudio Release Build VER:R05R998_V7.2.198_D20211210** =
292 292  
293 -(% class="wikigeneratedid" id="HBugsfixed-1" %)
294 -**Bugs fixed**
165 +(% class="wikigeneratedid" %)
166 +**Official Website:**
295 295  
296 -(% class="wikigeneratedid" id="HPCSoftware-2" %)
297 -PC Software
168 +(% class="wikigeneratedid" %)
169 +**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]]**
298 298  
299 -* Optimize the display style of text objects;
300 -* Optimize Lua script file size limitation to 512KB;
301 -* Optimize the import of text library and the limitation to 2000;
302 -* Protocol driver names standardized;
303 -* Font size is open to 512;
304 -* Lua script debugging window can be configured as enabled or not in Project Settings;
305 -* Optimize the font display of Runbar;
306 -* Optimized the forced backup function of project file, now you can click the cancel button to not backup;
307 -* Optimized and adjusted the default size of the password keyboard screen of newly-created projects;
308 -* Wrong display range of the History trend chart;
309 -* The font display of Drop-down List on PC is different from the actual screen;
310 -* Software crash caused by deleting the Address Library name;
311 -* General Series SMS protocol cannot be selected;
171 +**Google Drive:**
312 312  
313 -(% class="wikigeneratedid" id="HHMIApplication-2" %)
314 -HMI Application
173 +**[[Download Link>>https://drive.google.com/file/d/1lRfgoOwAs7lgL4b-ZdVUvE6itHWCpfd5/view?usp=sharing]]**
315 315  
316 -* Multi-Language display of text fonts;
317 -* Password keyboard input to display the plain text first and then the * sign;
318 -* Prompt display of Screen Lock for ie and ig;
319 -* Auto refresh of Data Record;
175 +== **Bugs Fixed** ==
320 320  
321 -(% class="wikigeneratedid" id="HDriverProtocol-2" %)
322 -Driver Protocol
177 +=== **PC Software** ===
323 323  
324 -* Communication cannot be performed after entering the backstage project;
325 -* Stuck screen problem caused by the protocol IEC60870-104 Client;
179 +A) Optimize the display style of text objects;
326 326  
327 -(% class="wikigeneratedid" id="HNewfunctions-1" %)
328 -**New functions**
181 +B) Optimize Lua script file size limitation to 512KB;
329 329  
330 -(% class="wikigeneratedid" id="HPCSoftware-3" %)
331 -PC Software
183 +C) Optimize the import of text library and the limitation to 2000;
332 332  
333 -* New ie series model: 3035ie;
334 -* New ig series models: 3070ig, 3102ig;
335 -* License agreement for the software installation setup process;
336 -* Object Lock/Unlock function (Pushpin);
337 -* Lua Editor to highlight the same content of the selected text;
338 -* Font style settings of the Runbar and chart type objects;
339 -* Software installation package VC 2017 runtime library;
185 +D) Protocol driver names standardized;
340 340  
341 -(% class="wikigeneratedid" id="HHMIApplication-3" %)
342 -HMI Application
187 +E) Font size is open to 512;
343 343  
344 -* Recipe address discontinuous address setting;
345 -* Trim 0 display setting for numeric input;
346 -* Address Mapping continuous writing settings;
347 -* Screensaver function;
348 -* Multi-Link function (not supported by ie and ig series);
349 -* Traditional recipe function is only applicable to the LEVI2PI project that uses the Recipe function;
350 -* Disc Record Chart;
351 -* Lua script weather forecast function interfaces;
352 -* The ie series supports the barcode scanner;
189 +F) Lua script debugging window can be configured as enabled or not in Project Settings;
353 353  
354 -(% class="wikigeneratedid" id="HDriverProtocol-3" %)
355 -Driver Protocol
191 +G) Optimize the font display of Runbar;
356 356  
357 -* Koyo Modbus RTU;
358 -* ASK series;
359 -* Anda inverter;
360 -* Optimize the barcode scanner protocol;
193 +H) Optimized the forced backup function of project file, now you can click the cancel button to not backup;
361 361  
362 -== V7.1.117_D20210320 ==
195 +I) Optimized and adjusted the default size of the password keyboard screen of newly-created projects;
363 363  
364 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20210320.zip]]
365 -* Dropbox: [[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=PIStudio20210320.zip&subfolder_nav_tracking=1]]
197 +J) Wrong display range of the History trend chart;
366 366  
367 -(% class="wikigeneratedid" id="HBugsfixed-2" %)
368 -**Bugs fixed**
199 +K) The font display of Drop-down List on PC is different from the actual screen;
369 369  
370 -(% class="wikigeneratedid" id="HPCSoftware-4" %)
371 -PC Software
201 +L) Software crash caused by deleting the Address Library name;
372 372  
373 -* Fix the crash problem of the software;
374 -* Renew the wiring diagram and pin definition diagram;
375 -* After the address is annotated, still able to communicate in Lua script;
376 -* Ethernet download optimization;
377 -* The project folder contains special language characters(except Chinese and English), errors in compiling Lua file and project, failed to download the project;
378 -* Use some fonts will cause software crash when compiling the project;
203 +M) General Series SMS protocol cannot be selected;
379 379  
380 -(% class="wikigeneratedid" id="HHMIApplication-4" %)
381 -HMI Application
205 +=== **HMI Application** ===
382 382  
383 -* Occasionally occur stuck logo problem after enable the Index of Recipe function;
384 -* B) Frequently screen switching might have a little chance cause stuck problem if there exist many table objects on the screen;
385 -* There is a little chance cause the stuck problem if use the script;
386 -* The stuck problem if use User permission;
387 -* The stuck problem when Data record upload;
388 -* There is a little chance to jump to the test interface after restart;
389 -* After the backlight is off, there is a small chance that the screen will display abnormal;
390 -* Video play cause stuck problem of General series 9150;
391 -* When the HMI just turned on, Recipe Display on the main screen is displayed as NULL;
392 -* Optimize Lua built-in library and file read/write functions;
393 -* The label of the operation value in the Operation record is displayed abnormal;
394 -* The length of channel name for Data record exceeds 32 bytes, will cause failed recording;
395 -* After entering the installment password, restart immediately, would require entering the password again;
207 +A) Multi-Language display of text fonts;
396 396  
397 -(% class="wikigeneratedid" id="HDriverProtocol-4" %)
398 -Driver Protocol
209 +B) Password keyboard input to display the plain text first and then the * sign;
399 399  
400 -* Frequently screen switching and there are many external addresses on the screen, which might have a little chance cause a stuck problem; 
401 -* Ethernet free tags may cause touch problem with no response;
402 -* Ethernet free tags occur error in compiling the project;
403 -* The input/output terminals of communication with MIKOM PLC are abnormal;
404 -* The reading information from scanner will not display if it exceeds 128 characters;
405 -* Failed to communicate with the OMRON NX/NJ PLC communication after power-on the screen and then power on the PLC.
406 -* When HMI+ is just turned on, the Ethernet communication prompts timeout;
407 -* When communicate with Siemens new protocol, will let the HMI stuck on LOGO screen;
211 +C) Prompt display of Screen Lock for ie and ig;
408 408  
409 -(% class="wikigeneratedid" id="HNewfunctions-2" %)
410 -**New functions**
213 +D) Auto refresh of Data Record;
411 411  
412 -(% class="wikigeneratedid" id="HPCSoftware-5" %)
413 -PC Software
215 +=== **Driver Protocol** ===
414 414  
415 -* New ie series: 3043ie, 3043ieS, 3070ie, 3102ie;
416 -* Industry purpose-designated models: ie series 3070ind, 3102ind, I series 3070ind-n;
417 -* Import and export function for Gallery file ( .blb or .plb format);
217 +A) Communication cannot be performed after entering the backstage project;
418 418  
419 -(% class="wikigeneratedid" id="HHMIApplication-5" %)
420 -HMI Application
219 +B) Stuck screen problem caused by the protocol IEC60870-104 Client;
421 421  
422 -* VNC LAN monitoring function ( require i series and PI+ models with Ethernet port and customized, the -O model in General series still use HMI Monitor System)
423 -* Resource report function to count the total memory used by the current screen;
424 -* Message prompt list (timeout , message , only available for ie series);
425 -* Timer and Trigger function in Lua script (only available for ie series);
426 -* Lua custom object, Lua table drawing, Lua curve drawing (only available for ie series);
427 -* Continuous input function of numeric and character object;
428 -* 4 Macro script functions involving file operations, FileCmpDir(), MyDeleteFile(), WriteWordToFile(), ReadWordFormFile();
429 -* The backstage interface can upgrade PLC program to support 5VPLC program download (only available for 3000i and PI+ series);
221 +== **New Functions Added** ==
430 430  
431 -(% class="wikigeneratedid" id="HDriverProtocol-5" %)
432 -Driver Protocol
223 +=== **PC Software** ===
433 433  
434 -* Keyence KV series;
225 +A) New ie series model: 3035ie;
435 435  
436 -== Notification of PI+ ==
227 +B) New ig series models: 3070ig, 3102ig;
437 437  
438 -* [[Download Link>>url:https://drive.google.com/file/d/1UMb8YGc5lLSfoF_UHD5A4HwE_HKd-Qg7/view?usp=sharing]]
229 +C) License agreement for the software installation setup process;
439 439  
440 -= **2 Levi2PI** =
231 +D) Object Lock/Unlock function (Pushpin);
441 441  
442 -== V4.5.8 ==
233 +E) Lua Editor to highlight the same content of the selected text;
443 443  
444 -* [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Levi2PI.zip]]
235 +F) Font style settings of the Runbar and chart type objects;
445 445  
446 -= **3 HMI Monitor System** =
237 +G) Software installation package VC 2017 runtime library;
447 447  
448 -== VER: 20210317 ==
239 +=== **HMI Application** ===
449 449  
450 -* Google Drive: [[Download Link>>https://drive.google.com/file/d/1RA3ui3jTCKtQTCLySjD4Qi7Ut58EYYD1/view?usp=sharing]]
241 +A) Recipe address discontinuous address setting;
451 451  
452 -= **4 Logo Making Tool** =
243 +B) Trim 0 display setting for numeric input;
453 453  
454 -* Google Drive: [[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]
245 +C) Address Mapping continuous writing settings;
246 +
247 +D) Screensaver function;
248 +
249 +E) Multi-Link function (not supported by ie and ig series);
250 +
251 +F) Traditional recipe function is only applicable to the LEVI2PI project that uses the Recipe function;
252 +
253 +G) Disc Record Chart;
254 +
255 +H) Lua script weather forecast function interfaces;
256 +
257 +I) The ie series supports the barcode scanner;
258 +
259 +=== **Driver Protocol** ===
260 +
261 +A) Koyo Modbus RTU;
262 +
263 +B) ASK series;
264 +
265 +C) Anda inverter;
266 +
267 +D) Optimize the barcode scanner protocol;
268 +
269 += **PIStudio Release Build VER:R05R998_V7.1.117_D20210320** =
270 +
271 +**Official Website:**
272 +
273 +**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20210320.zip]]**
274 +
275 +**Dropbox:**
276 +
277 +**[[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=PIStudio20210320.zip&subfolder_nav_tracking=1]]**
278 +
279 +== **Bugs Fixed** ==
280 +
281 +=== **PC Software** ===
282 +
283 +A) Fix the crash problem of the software;
284 +
285 +B) Renew the wiring diagram and pin definition diagram;
286 +
287 +C) After the address is annotated, still able to communicate in Lua script;
288 +
289 +D) Ethernet download optimization;
290 +
291 +E) The project folder contains special language characters(except Chinese and English), errors in compiling Lua file and project, failed to download the project;
292 +
293 +F) Use some fonts will cause software crash when compiling the project;
294 +
295 +=== **HMI Application** ===
296 +
297 +A) Occasionally occur stuck logo problem after enable the Index of Recipe function;
298 +
299 +B) Frequently screen switching might have a little chance cause stuck problem if there exist many table objects on the screen;
300 +
301 +C) There is a little chance cause the stuck problem if use the script;
302 +
303 +D) The stuck problem if use User permission;
304 +
305 +E) The stuck problem when Data record upload;
306 +
307 +F) There is a little chance to jump to the test interface after restart;
308 +
309 +G) After the backlight is off, there is a small chance that the screen will display abnormal;
310 +
311 +H) Video play cause stuck problem of General series 9150;
312 +
313 +I) When the HMI just turned on, Recipe Display on the main screen is displayed as NULL;
314 +
315 +J) Optimize Lua built-in library and file read/write functions;
316 +
317 +K) The label of the operation value in the Operation record is displayed abnormal;
318 +
319 +L) The length of channel name for Data record exceeds 32 bytes, will cause failed recording;
320 +
321 +M) After entering the installment password, restart immediately, would require entering the password again;
322 +
323 +=== **Driver Protocol** ===
324 +
325 +A) Frequently screen switching and there are many external addresses on the screen, which might have a little chance cause a stuck problem; 
326 +
327 +B) Ethernet free tags may cause touch problem with no response;
328 +
329 +C) Ethernet free tags occur error in compiling the project;
330 +
331 +D) The input/output terminals of communication with MIKOM PLC are abnormal;
332 +
333 +E) The reading information from scanner will not display if it exceeds 128 characters;
334 +
335 +F) Failed to communicate with the OMRON NX/NJ PLC communication after power-on the screen and then power on the PLC.
336 +
337 +G) When HMI+ is just turned on, the Ethernet communication prompts timeout;
338 +
339 +H) When communicate with Siemens new protocol, will let the HMI stuck on LOGO screen;
340 +
341 +== **New Functions Added** ==
342 +
343 +=== **PC Software** ===
344 +
345 +A) New ie series: 3043ie, 3043ieS, 3070ie, 3102ie;
346 +
347 +B) Industry purpose-designated models: ie series 3070ind, 3102ind, I series 3070ind-n;
348 +
349 +C) Import and export function for Gallery file ( .blb or .plb format);
350 +
351 +=== **HMI Application** ===
352 +
353 +A) VNC LAN monitoring function ( require i series and PI+ models with Ethernet port and customized, the -O model in General series still use HMI Monitor System)
354 +
355 +B) Resource report function to count the total memory used by the current screen;
356 +
357 +C) Message prompt list (timeout , message , only available for ie series);
358 +
359 +D) Timer and Trigger function in Lua script (only available for ie series);
360 +
361 +E) Lua custom object, Lua table drawing, Lua curve drawing (only available for ie series);
362 +
363 +F) Continuous input function of numeric and character object;
364 +
365 +G) 4 Macro script functions involving file operations, FileCmpDir(), MyDeleteFile(), WriteWordToFile(), ReadWordFormFile();
366 +
367 +H) The backstage interface can upgrade PLC program to support 5VPLC program download (only available for 3000i and PI+ series);
368 +
369 +== **Driver Protocol** ==
370 +
371 +A) Keyence KV series;
372 +
373 +== **Notification of PI+** ==
374 +
375 +**[[Download Link>>url:https://drive.google.com/file/d/1UMb8YGc5lLSfoF_UHD5A4HwE_HKd-Qg7/view?usp=sharing]]**
376 +
377 += **Levi2PI V4.3.8** =
378 +
379 +**Official Website:**
380 +
381 +**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/Wecon%20LEVI2PI.zip]]**
382 +
383 +**Dropbox:**
384 +
385 +**[[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=Wecon+LEVI2PI.zip&subfolder_nav_tracking=1]]**
386 +
387 += **Levi2PI V4.5.6(Test Version)** =
388 +
389 +**Google Drive**
390 +
391 +**[[Download Link>>https://drive.google.com/file/d/10Ay8dr7MK6CCpMIKEmKITG3DGipffJsI/view?usp=sharing]]**
392 +
393 += **HMI Monitor System20210317** =
394 +
395 +**Google Drive:**
396 +
397 +**[[Download Link>>https://drive.google.com/file/d/1RA3ui3jTCKtQTCLySjD4Qi7Ut58EYYD1/view?usp=sharing]]**
398 +
399 +
400 += **6 Logo Making Tool** =
401 +
402 +**Google Drive:**
403 +
404 +**[[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]**