1 1  = **1 PIStudio** =
2 2  
3 +== **V9.1.18.24122702** ==
4 +
5 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.1.18.24122702.zip]]
6 +
7 +== **V8.4.114_D24061301** ==
8 +
9 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.114.24061301.zip]]
10 +
11 +**Bugs fixed**
12 +
13 +PC Software
14 +
15 +1. When the MQTT sending mode is set a trigger, entering the trigger address directly cannot save.
16 +1. Arc object property page configuration angle cannot enter 0.
17 +1. Add the 5V protocol first, and then add the printer's protocol, can't change the protocol of the printer.
18 +1. The value of the meter and the color of the scale are inconsistent.
19 +1. After decompile tool open, the software crash.
20 +1. Off-line emulator run time the pictures of function switch object do not display.
21 +1. After deleting multiple screens, the software crash.
22 +1. After copying the local screen successfully, the directly compiled screen objects will be smaller than the modified screen objects.
23 +1. The same project file can be opened by multiple software at the same time.
24 +1. Object id duplication.
25 +1. The bar graph does not use variables, but when compiling, it prompts the variable address error.
26 +1. Using dynamic recipients, email addresses are not compiled and display recipient errors.
27 +1. The objects compile with the address error, but there is no note about what the address error is for which objects.
28 +1. When the circle/ellipse coords are in the negative area, no error message is displayed.
29 +1. When text library imports excel,the blank space and subsequent data cannot be imported.
30 +1. The function screen is deleted and then add it again.it cannot be added.
31 +1. The wrong continuous length when compiling the address of the data record.
32 +1. The wrong continuous length of lua script.
33 +1. PI3041ig configuration Ethernet 2 does not take effect.
34 +1. The wrong coord prompt when the rectangular objects is determined.
35 +1. The data record storage in project setting is error.
36 +1. Fix other problems.
37 +
38 +HMI Application
39 +
40 +1. The function is invalid after the function switch is pressed;
41 +1. The lua function io.open cannot open files under the u disk and sd card;
42 +1. The data record configuration data type is a string, the length is two characters, and it will be recorded more than two characters when data is collected record.
43 +1. The data type of the word switch is BCD code, and the increase and decrease do not follow the rule of the BCD code.
44 +1. "Database Format Mismatch" error after Lua script modifies table header.
45 +1. PI3070ig printing part text box printing font is not clear.
46 +1. In the offline simulation state, the graphics position offset occurs in the project with 1920*1080 resolution when the graphics are drawn by the address control.
47 +1. drawing when the graphics position offset.
48 +1. Receiving Data in Lua User Free Protocol 485 _ 2.
49 +1. Lua initialization uses the we_bas_jump screen function to jump to the screen is invalid, and there is a black screen.
50 +1. The data record cannot be recorded when the data record group id is 0.
51 +1. Value input objects check the display natural decimal function is invalid.
52 +1. To enable address control state text, must set the state sequence number, text content, and trigger settings.
53 +1. MQTT is published periodically, and changing the value of the address will also publish.
54 +1. The text on picture has a probability of becoming blurry.
55 +1. When the reset switch triggers hiding, it cannot automatically reset.
56 +1. Alarm records and data records are exported to CSV, and the table header does not switch with language switching.
57 +1. The screen alarm record csv exported using DbToCsvFile has no alarm content.
58 +1. The group number displayed in the recipe Group number address does not match the ID of the recipe display objects.
59 +1. When the number of recipe groups is set to 0, the file name address of the index does not change when there are multiple recipe files.
60 +1. The gallery is too large, causing crash.
61 +1. Drop down list username can't show multilingual.
62 +1. V-NET server anomaly causes device disconnection.
63 +1. The HMI goes off-line due to abnormal dialing of the 4G module.
64 +1. Recipe selected line ID does not match the ID in the address.
65 +1. The USB download project time is not updated, and the local time is not synchronized with the computer time.
66 +1. The keyboard screen cannot be closed normally through we_bas_closescreen function.
67 +1. The IE series uses calibri fonts and the screen display is in Song style.
68 +1. After setting floating setting as big-endian,the recipe table is displayed in Little-endian.
69 +1. Long press the bit switch, and then release the bit switch after entering the static screen saver , and the bit switch cannot be reset.
70 +1. After the function switch uses object password, the password is invalid after the screen jumps.
71 +1. PI8150ig makes the font size smaller when using calibri font.
72 +1. IN series long press upper left corner, upper right corner invalid.
73 +1. Fix other problems.
74 +
75 +Drive
76 +
77 +1. DELTA AS300 MODBUS TCP driver operation D.b bit address invalid.
78 +1. OMRONE5CC driver communication abnormal.
79 +1. Xunpu printer driver prints pictures abnormally.
80 +1. Rockwell Ethernet/IP (CompactLogix Series) driver communication exception.
81 +1. Siemens LOGO drive on-line simulation crash.
82 +1. Fix other problems.
83 +
84 +**New functions**
85 +
86 +Driver
87 +
88 +1. LS MASTER Protocol driver supports bit address selection of D register.
89 +1. TECO MP300 MODBUS TCP protocol.
90 +1. TECO MP300 MODBUS RTU protocol.
91 +
92 +**Precautions**
93 +
94 +Drive 
95 +
96 +✎Note: WECON LX6V FreeTag Ethernet will not be maintained in the future, please switch to WECON LX6V EtherNet/IP.
97 +
98 +✎Note: WECON LX6V FreeTag Series will not be maintained in the future, please switch to Ethernet WECON LX6V EtherNet/IP
99 +
3 3  == V8.4.66_D23102001 ==
4 4  
5 5  * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.66.23102001.zip]]
... ... @@ -242,6 +242,238 @@
242 242  Fix other problems.
243 243  )))
244 244  
342 +Drive
343 +
344 +1. ShortMessage_Module message group sending timeout;
345 +1. When using Modbus_RTU_All Ethernet, the communication is reported error;
346 +1. (((
347 +OpenCAN drive communication slowly;
348 +)))
349 +1. (((
350 +WECON LX3VP recipe continuous reading fails;
351 +)))
352 +1. (((
353 +WECON LX5V M address write instruction length error;
354 +)))
355 +1. (((
356 +MIT QJ71 MELSEC PROTOCOL communication abnormally;
357 +)))
358 +1. (((
359 +Mitsubishi FX3U Drive Counter negative value display error;
360 +)))
361 +1. (((
362 +OpenCAN drive baud rate set error;
363 +)))
364 +1. (((
365 +Omron CP2E and PI HMI/online stimulation communication timeout;
366 +)))
367 +1. (((
368 +User-defined Protocol single sending cannot be used;
369 +)))
370 +1. (((
371 +Incorrect display of 32-bit signed number in MITSUBISHI FX3U/3G/3SA address CH200;
372 +)))
373 +1. (((
374 +A physical serial port double 485 will time out when communicating at the same time;
375 +)))
376 +1. (((
377 +User-defined Protocol does not display in online simulation;
378 +)))
379 +1. (((
380 +Abnormal communication of HMI with azbil protocol;
381 +)))
382 +1. (((
383 +Siemens Protocol S7300 (with PC Adaptor New) DB address is not available;
384 +)))
385 +1. (((
386 +Modbus_TCP_Master does not reply when sending read instruction;
387 +)))
388 +1. (((
389 +USB printer protocol uses print object; the printing will print black edges;
390 +)))
391 +1. (((
392 +SMS protocol cannot receive and send, Add ClrMsg register to delete all information;
393 +)))
394 +1. (((
395 +MODBUS RTU Slave (All Function) broadcasting station number communication problem. Add BrtCat station number set registers.
396 +)))
397 +1. (((
398 +Siemens 200SMART communication abnormally;
399 +)))
400 +1. (((
401 +Xinjie XDH communication abnormally;
402 +)))
403 +1. (((
404 +Drive customized protocol cache cannot be cleared;
405 +)))
406 +1. (((
407 +Errors in DWORD read/write in INOVANCE H5U_Easy PLC Ethernet Protocol;
408 +)))
409 +1. (((
410 +Parameters such as PI timeout reconnection are not valid;
411 +)))
412 +1. (((
413 +The matching mode of user-defined protocol receiving first and then sending;
414 +)))
415 +1. (((
416 +Fix other problems;
417 +)))
418 +
419 +**New functions**
420 +
421 +PC Software
422 +
423 +1. Data record db file merge function of DataLogTool (Only HMI V2.0 system supports);
424 +1. (((
425 +Text color dynamic configuration of numerical value and text input object (Only HMI V2.0 system supports);
426 +)))
427 +1. (((
428 +8000ig supports that the maximum number of configuring communication connections is 32 (Only HMI V2.0 system supports);
429 +)))
430 +1. (((
431 +Curve object add 8 types of line configuration (Only HMI V2.0 system supports);
432 +)))
433 +1. (((
434 +Ethernet communication supports the selection and settings of network card type (Only HMI V2.0 system supports);
435 +)))
436 +1. (((
437 +Customized name configuration is added for communication port configuration, which can be used in address editing interface and address list interface (Only HMI V2.0 system supports);
438 +)))
439 +1. (((
440 +**Improve compilation speed;**
441 +)))
442 +1. (((
443 +**Function switch right-click selection to jump to the target screen;**
444 +)))
445 +1. (((
446 +**Right-click the object and select jump to image gallery configuration;**
447 +)))
448 +1. (((
449 +**String table configuration;**
450 +)))
451 +1. (((
452 +**External keyboard shortcut configuration (Only ig series and MD series support);**
453 +)))
454 +1. (((
455 +**Visual configuration of MQTT docking third-party platform (Only ig series and MD series support);**
456 +)))
457 +1. (((
458 +**8070ig and 8102ig support video player controls.**
459 +)))
460 +
461 +HMI applications
462 +
463 +1. Countdown prompt to enter background (Only HMI V2.0 system supports);
464 +1. Background LAN security monitoring configuration (Only HMI V2.0 system supports);
465 +1. Background USB flash disk upgrade mirror limit fallback version (Only HMI V2.0 system supports);
466 +1. 8000ig double network port configuration (Only HMI V2.0 system supports);
467 +1. Support to modify Ethernet static IP configuration through special registers (Only HMI V2.0 system supports);
468 +1. User management supports multi languages (Only HMI V2.0 system supports);
469 +1. 8000ig supports video play (Only HMI V2.0 system supports);
470 +1. Text color dynamic configuration of numerical value and text input object (Only HMI V2.0 system supports);
471 +1. Dynamic screensaver (Only HMI V2.0 system supports);
472 +1. Lua SMS sending (only supported by HM I V2.0 system);
473 +1. Lua obtains SIM card information (Only HMI V2.0 system supports);
474 +1. Camera configuration (Only HMI V2.0 system supports);
475 +1. Support PI8000/PI9000 series update system without deleting project (Only HMI V2.0 system supports);
476 +1. Backstage supports multi languages switch and language customization (Only HMI V2.0 system supports);
477 +1. (((
478 +When switching languages, clean up the screen cache (Only HMI V2.0 system supports);
479 +)))
480 +1. (((
481 +Register HSW1890 triggers to refresh network signal (Only HMI V2.0 system supports);
482 +)))
483 +1. (((
484 +Register HSW1891 controls the cleaning of the screen cache (Only HMI V2.0 system supports);
485 +)))
486 +1. (((
487 +Background stimulates the terminal (Only HMI V2.0 system supports);
488 +)))
489 +1. (((
490 +**Dynamic text (Only HMI V2.0 system supports);**
491 +)))
492 +1. (((
493 +**External keyboard shortcut (Only ig series and MD series support);**
494 +)))
495 +1. (((
496 +**HMIdevice name (Only HMI V2.0 system supports);**
497 +)))
498 +1. (((
499 +**Background supports cloud server switching (Only general 8000 series with V2.0 system, ig series and MD series supports);**
500 +)))
501 +1. (((
502 +**Support remote screen adaptation display of vertical screen project (Only HMI V2.0 system supports);**
503 +)))
504 +1. (((
505 +**Common lua script function of verification algorithms (Only HMI V2.0 system supports);**
506 +)))
507 +1. (((
508 +**INSeries (IN1071, IN1072, IN1073) does not distinguish models and supports mutual projects regardless of models;**
509 +)))
510 +
511 +Driver protocol
512 +
513 +1. WECON LX6V EtherNet / IP (Tag protocol optimized version) (Only HMI V2.0 system supports);
514 +1. Rockwell EtherNet / IP (Tag protocol optimized version) (Only HMI V2.0 system supports);
515 +1. OMRON EtherNet/IP (NX/NJ Series) (Tag protocol optimized version) (Only HMI V2.0 system supports);
516 +1. MODBUS RTU Slave (All Fuction OneBaseAddress) can customize broadcast address;
517 +1. SMS module can delete all information;
518 +1. INOVANCE H5U_Easy PLC driver protocol (Serial port);
519 +1. INOVANCE H5U_Easy free tag protocol drive;
520 +1. Xinjie XD/XE drive;
521 +1. Veichi V3 drive;
522 +1. Shihlin SX6V EtherNet/IP Protocol;
523 +1. CODESYS V3 drive;
524 +1. Modbus_Server_IoT_Plat drive;
525 +1. (((
526 +MIT Q00H CPU Port PROTOCOL drive;
527 +)))
528 +1. (((
529 +Schneider TM221 drive;
530 +)))
531 +1. (((
532 +Delta_DVP_ModbusRTU drive;
533 +)))
534 +1. (((
535 +INOVANCE H5U_Easy ModbusTCP drive;
536 +)))
537 +1. (((
538 +Siemens S7-xxx Ethernet OP new drive;
539 +)))
540 +1. (((
541 +MODBUS RTU Slave (All Function) protocol retry timeout time factor multiple ToMu;
542 +)))
543 +1. (((
544 +Schneider TM221 drive;
545 +)))
546 +
547 +{{info}}
548 +**✎Note: The maximum communication number of free tag protocol and CODESYS V3 configuration in models of each series is shown in the following table.**
549 +{{/info}}
550 +
551 +|**Series model**|**Recommended maximum number of free tag protocols**|**Recommended maximum number of CODESYS V3 protocols**
552 +|8000 Series|4|Configuration is not supported.
553 +|3000 Series|Configuration is not supported.|Configuration is not supported.
554 +|9000 Series|Configuration is not supported.|Configuration is not supported.
555 +|3000i Series|Configuration is not supported.|Configuration is not supported.
556 +|ie Series (3043ies with network port)|2|Configuration is not supported.
557 +|ie Series (Other models)|Configuration is not supported.|Configuration is not supported.
558 +|3000ig Series|4|2
559 +|8000ig Series|6|2
560 +|MD3000 Series|4|Configuration is not supported.
561 +|IN Series|Configuration is not supported.|Configuration is not supported.
562 +
563 +(% class="wikigeneratedid" %)
564 +**New models**
565 +
566 +(1). ie Series: 3070ie-H;
567 +
568 +(2). IN Series: IN1071, IN1072, IN1073;
569 +
570 +(3). MD Series: MD3102;
571 +
572 +(4). ig Series: 3070ig-H, 3043ig, 8070ig, 8102ig, 8043ig;
573 +
245 245  == V8.2.95_D20220928 ==
246 246  
247 247  * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220928.zip]]
... ... @@ -302,13 +302,13 @@
302 302  1. The communication is disconnected and cannot be reconnected after ig series VPN penetrates;
303 303  1. Optimize the polling speed of VB trigger script;
304 304  
305 -Drive the updated
634 +Drive the updated
306 306  
307 307  1. The abnormal communication caused by recipe reading;
308 308  
309 309  Driver Protocol
310 310  
311 -1. Add Omron (NX/NJ) free label driver;
640 +1. Add Omron (NX/NJ) free tadriver;
312 312  
313 313  **New functions**
314 314  
... ... @@ -596,9 +596,9 @@
596 596  
597 597  = **2 Levi2PI** =
598 598  
599 -== V4.5.8 ==
928 +== V4.6.2 ==
600 600  
601 -* [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Levi2PI.zip]]
930 +* [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Levi2PI%20v4.6.2.zip]]
602 602  
603 603  = **3 HMI Monitor System** =
604 604  
1717728415376-899.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +56.5 KB
Content