1 1  = **1 PIStudio** =
2 2  
3 +== **V9.1.18.24122702** ==
4 +
5 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.1.18.24122702.zip]]
6 +
7 +**Bugs fixed**
8 +
9 +1. RE series V-BOX PLC Pass-through sometime can't work properly.
10 +1. RE series V-BOX data record upload can't work properly.
11 +1. PI8043ig and PI3041ig recipe object unable to display properly in web side.
12 +1. When entering the backstage for the first time after the screen is restarted, the first digit of the backstage password is invalid.
13 +1. PI8043ig project file is too large to the logo is stuck when HMI restarted.
14 +1. WIFI model can not enable after update the system.
15 +1. HMI crash and freeze when downloading PLC project.
16 +1. When the rectangle/arc/circle object is first initialized, a shadow will appears.
17 +1. The cloud icon in backstage state error.
18 +1. In off-line simulation.The left lable of Numeric Input/Display object affect natural decimal display.
19 +1. MQTT tool publish bit address,the length setting is not 1,message error.
20 +1. MQTT V5 protocol cannot automatically connect after network disconnection.
21 +1. The cloud management tool cannot log in to non-administrator users normally.
22 +1. Object lock does not work for bit switch momentary mode.
23 +1. WIFI is not connected, but IP still exists.
24 +1. The actual minimum pressing time of the function switch does not match the setting.
25 +1. RH-WF V-BOX indicator lamp display error.
26 +1. Data record display object start time setting error.
27 +1. The camera display object disappear after switching screens.
28 +1. After using the four arithmetic operations in address mapping, reading the value in read-only mode displays an abnormality.
29 +1. Object level password does not match the setting.
30 +1. In offline simulation, the new recipe tool crashes by clicking keyboard letters.
31 +1. Recipe name changes when switching screens.
32 +1. PLC program upload fails when PLC Pass-Through.
33 +1. IDEC MicroSmart Protocol:TC CC register modifying the value of the address results in an error in the value of the next address.
34 +1. Delta_AS300_TCP Protocol:D.b register cannot modify status.
35 +1. OPCUA Client:communication error but have no time-out message.
36 +1. IEC104client:HMI get black screen after downloading this protocol.
37 +
38 +**New functions**
39 +
40 +PC Software
41 +
42 +1. New project properties page.
43 +1. i/ie/ig/IN/RE/RH series all support screen style.
44 +1. Download tool support RE,RH series flash light and test network.
45 +1. New Device management tool.
46 +1. Software homepage embedded Wecon support center.
47 +1. Allow configuration preserve network configuration when download the project.
48 +1. Software online update.
49 +1. Scada canvas extension, new draft area.
50 +1. Recipe element support bit address.
51 +1. OPC UA server.
52 +1. New X,Y internal registers(RH series).
53 +1. 3000ig series Limitation of the Ethernet communication protocol up to 32.
54 +
55 +HMI Application
56 +
57 +1. New recipe object-Recipe Record:Integrated search, add, delete, download, upload, import, export, and switch recipe functions.
58 +1. New backstage:The background can be exited instead of restarted,New UI,Ethernet download PLC program,USB update support update the system and project at the same time.
59 +1. Remote backstage.
60 +1. New system keyboard.
61 +1. Character Input/Display object support multi line display.
62 +1. Character Input/Display object support choose data format(UTF-8/GBK/UNICODE).
63 +1. Numeric Input/Display object support more 64bit data format.
64 +1. Modification of serial port parameters takes effect immediately.
65 +1. RE series can be bound to V-NET.
66 +1. lua script open user permission function interface.
67 +1. New Multi-link function.
68 +1. New special registers related to automatic logout of user functionse.
69 +1. Alarm info support multiple variables.
70 +1. Min.hold time countdown.
71 +1. ig-O support Wecon 6V freetags protocol and CODESYS V3 protocol.
72 +1. (((
73 +New special registers related to displaying user storage space information.
74 +)))
75 +
76 +Driver protocol
77 +
78 +1. OPCUA Client.
79 +1. Siemens S7-1200/1500 Ethernet FreeTag.
80 +1. TwinCAT PLC Ethernet.
81 +1. KEYENCE KV-5000(Ethernet) using bit address in word address.
82 +
83 +**New model**
84 +
85 +1. RE series:RE-00,RE-00-LA,RE-4G,RE-4G-LA
86 +1. RH series:RH-WIFI
87 +1. ig series:PI3101ig,PI8101ig,PI8121ig
88 +
89 +**Notice**
90 +
91 +1. The new version can not support general series(PI3000,PI8000,PI9000).Please use the old version (Release Build VER:R05R998_V8.4.114_D24061301) to program the general series.
92 +1. Projects opened with the new version cannot be opened with the old version. Please make sure to back up the project.
93 +1. Cannot roll back the version after upgrading.
94 +1. After the upgrade, the supported protocols will change. For details, please refer to:[[Limitation of the Ethernet communication protocol - Wecon>>url:https://docs.we-con.com.cn/bin/view/PIStudio/PLC Protocol/Limitation of the Ethernet communication protocol/]]
95 +
96 +== **V8.4.114_D24061301** ==
97 +
98 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.114.24061301.zip]]
99 +
100 +**Bugs fixed**
101 +
102 +PC Software
103 +
104 +1. When the MQTT sending mode is set a trigger, entering the trigger address directly cannot save.
105 +1. Arc object property page configuration angle cannot enter 0.
106 +1. Add the 5V protocol first, and then add the printer's protocol, can't change the protocol of the printer.
107 +1. The value of the meter and the color of the scale are inconsistent.
108 +1. After decompile tool open, the software crash.
109 +1. Off-line emulator run time the pictures of function switch object do not display.
110 +1. After deleting multiple screens, the software crash.
111 +1. After copying the local screen successfully, the directly compiled screen objects will be smaller than the modified screen objects.
112 +1. The same project file can be opened by multiple software at the same time.
113 +1. Object id duplication.
114 +1. The bar graph does not use variables, but when compiling, it prompts the variable address error.
115 +1. Using dynamic recipients, email addresses are not compiled and display recipient errors.
116 +1. The objects compile with the address error, but there is no note about what the address error is for which objects.
117 +1. When the circle/ellipse coords are in the negative area, no error message is displayed.
118 +1. When text library imports excel,the blank space and subsequent data cannot be imported.
119 +1. The function screen is deleted and then add it again.it cannot be added.
120 +1. The wrong continuous length when compiling the address of the data record.
121 +1. The wrong continuous length of lua script.
122 +1. PI3041ig configuration Ethernet 2 does not take effect.
123 +1. The wrong coord prompt when the rectangular objects is determined.
124 +1. The data record storage in project setting is error.
125 +1. Fix other problems.
126 +
127 +HMI Application
128 +
129 +1. The function is invalid after the function switch is pressed;
130 +1. The lua function io.open cannot open files under the u disk and sd card;
131 +1. The data record configuration data type is a string, the length is two characters, and it will be recorded more than two characters when data is collected record.
132 +1. The data type of the word switch is BCD code, and the increase and decrease do not follow the rule of the BCD code.
133 +1. "Database Format Mismatch" error after Lua script modifies table header.
134 +1. PI3070ig printing part text box printing font is not clear.
135 +1. In the offline simulation state, the graphics position offset occurs in the project with 1920*1080 resolution when the graphics are drawn by the address control.
136 +1. drawing when the graphics position offset.
137 +1. Receiving Data in Lua User Free Protocol 485 _ 2.
138 +1. Lua initialization uses the we_bas_jump screen function to jump to the screen is invalid, and there is a black screen.
139 +1. The data record cannot be recorded when the data record group id is 0.
140 +1. Value input objects check the display natural decimal function is invalid.
141 +1. To enable address control state text, must set the state sequence number, text content, and trigger settings.
142 +1. MQTT is published periodically, and changing the value of the address will also publish.
143 +1. The text on picture has a probability of becoming blurry.
144 +1. When the reset switch triggers hiding, it cannot automatically reset.
145 +1. Alarm records and data records are exported to CSV, and the table header does not switch with language switching.
146 +1. The screen alarm record csv exported using DbToCsvFile has no alarm content.
147 +1. The group number displayed in the recipe Group number address does not match the ID of the recipe display objects.
148 +1. When the number of recipe groups is set to 0, the file name address of the index does not change when there are multiple recipe files.
149 +1. The gallery is too large, causing crash.
150 +1. Drop down list username can't show multilingual.
151 +1. V-NET server anomaly causes device disconnection.
152 +1. The HMI goes off-line due to abnormal dialing of the 4G module.
153 +1. Recipe selected line ID does not match the ID in the address.
154 +1. The USB download project time is not updated, and the local time is not synchronized with the computer time.
155 +1. The keyboard screen cannot be closed normally through we_bas_closescreen function.
156 +1. The IE series uses calibri fonts and the screen display is in Song style.
157 +1. After setting floating setting as big-endian,the recipe table is displayed in Little-endian.
158 +1. Long press the bit switch, and then release the bit switch after entering the static screen saver , and the bit switch cannot be reset.
159 +1. After the function switch uses object password, the password is invalid after the screen jumps.
160 +1. PI8150ig makes the font size smaller when using calibri font.
161 +1. IN series long press upper left corner, upper right corner invalid.
162 +1. Fix other problems.
163 +
164 +Drive
165 +
166 +1. DELTA AS300 MODBUS TCP driver operation D.b bit address invalid.
167 +1. OMRONE5CC driver communication abnormal.
168 +1. Xunpu printer driver prints pictures abnormally.
169 +1. Rockwell Ethernet/IP (CompactLogix Series) driver communication exception.
170 +1. Siemens LOGO drive on-line simulation crash.
171 +1. Fix other problems.
172 +
173 +**New functions**
174 +
175 +Driver
176 +
177 +1. LS MASTER Protocol driver supports bit address selection of D register.
178 +1. TECO MP300 MODBUS TCP protocol.
179 +1. TECO MP300 MODBUS RTU protocol.
180 +
181 +**Precautions**
182 +
183 +Drive 
184 +
185 +✎Note: WECON LX6V FreeTag Ethernet will not be maintained in the future, please switch to WECON LX6V EtherNet/IP.
186 +
187 +✎Note: WECON LX6V FreeTag Series will not be maintained in the future, please switch to Ethernet WECON LX6V EtherNet/IP
188 +
3 3  == V8.4.66_D23102001 ==
4 4  
5 5  * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.66.23102001.zip]]
... ... @@ -242,6 +242,238 @@
242 242  Fix other problems.
243 243  )))
244 244  
431 +Drive
432 +
433 +1. ShortMessage_Module message group sending timeout;
434 +1. When using Modbus_RTU_All Ethernet, the communication is reported error;
435 +1. (((
436 +OpenCAN drive communication slowly;
437 +)))
438 +1. (((
439 +WECON LX3VP recipe continuous reading fails;
440 +)))
441 +1. (((
442 +WECON LX5V M address write instruction length error;
443 +)))
444 +1. (((
445 +MIT QJ71 MELSEC PROTOCOL communication abnormally;
446 +)))
447 +1. (((
448 +Mitsubishi FX3U Drive Counter negative value display error;
449 +)))
450 +1. (((
451 +OpenCAN drive baud rate set error;
452 +)))
453 +1. (((
454 +Omron CP2E and PI HMI/online stimulation communication timeout;
455 +)))
456 +1. (((
457 +User-defined Protocol single sending cannot be used;
458 +)))
459 +1. (((
460 +Incorrect display of 32-bit signed number in MITSUBISHI FX3U/3G/3SA address CH200;
461 +)))
462 +1. (((
463 +A physical serial port double 485 will time out when communicating at the same time;
464 +)))
465 +1. (((
466 +User-defined Protocol does not display in online simulation;
467 +)))
468 +1. (((
469 +Abnormal communication of HMI with azbil protocol;
470 +)))
471 +1. (((
472 +Siemens Protocol S7300 (with PC Adaptor New) DB address is not available;
473 +)))
474 +1. (((
475 +Modbus_TCP_Master does not reply when sending read instruction;
476 +)))
477 +1. (((
478 +USB printer protocol uses print object; the printing will print black edges;
479 +)))
480 +1. (((
481 +SMS protocol cannot receive and send, Add ClrMsg register to delete all information;
482 +)))
483 +1. (((
484 +MODBUS RTU Slave (All Function) broadcasting station number communication problem. Add BrtCat station number set registers.
485 +)))
486 +1. (((
487 +Siemens 200SMART communication abnormally;
488 +)))
489 +1. (((
490 +Xinjie XDH communication abnormally;
491 +)))
492 +1. (((
493 +Drive customized protocol cache cannot be cleared;
494 +)))
495 +1. (((
496 +Errors in DWORD read/write in INOVANCE H5U_Easy PLC Ethernet Protocol;
497 +)))
498 +1. (((
499 +Parameters such as PI timeout reconnection are not valid;
500 +)))
501 +1. (((
502 +The matching mode of user-defined protocol receiving first and then sending;
503 +)))
504 +1. (((
505 +Fix other problems;
506 +)))
507 +
508 +**New functions**
509 +
510 +PC Software
511 +
512 +1. Data record db file merge function of DataLogTool (Only HMI V2.0 system supports);
513 +1. (((
514 +Text color dynamic configuration of numerical value and text input object (Only HMI V2.0 system supports);
515 +)))
516 +1. (((
517 +8000ig supports that the maximum number of configuring communication connections is 32 (Only HMI V2.0 system supports);
518 +)))
519 +1. (((
520 +Curve object add 8 types of line configuration (Only HMI V2.0 system supports);
521 +)))
522 +1. (((
523 +Ethernet communication supports the selection and settings of network card type (Only HMI V2.0 system supports);
524 +)))
525 +1. (((
526 +Customized name configuration is added for communication port configuration, which can be used in address editing interface and address list interface (Only HMI V2.0 system supports);
527 +)))
528 +1. (((
529 +**Improve compilation speed;**
530 +)))
531 +1. (((
532 +**Function switch right-click selection to jump to the target screen;**
533 +)))
534 +1. (((
535 +**Right-click the object and select jump to image gallery configuration;**
536 +)))
537 +1. (((
538 +**String table configuration;**
539 +)))
540 +1. (((
541 +**External keyboard shortcut configuration (Only ig series and MD series support);**
542 +)))
543 +1. (((
544 +**Visual configuration of MQTT docking third-party platform (Only ig series and MD series support);**
545 +)))
546 +1. (((
547 +**8070ig and 8102ig support video player controls.**
548 +)))
549 +
550 +HMI applications
551 +
552 +1. Countdown prompt to enter background (Only HMI V2.0 system supports);
553 +1. Background LAN security monitoring configuration (Only HMI V2.0 system supports);
554 +1. Background USB flash disk upgrade mirror limit fallback version (Only HMI V2.0 system supports);
555 +1. 8000ig double network port configuration (Only HMI V2.0 system supports);
556 +1. Support to modify Ethernet static IP configuration through special registers (Only HMI V2.0 system supports);
557 +1. User management supports multi languages (Only HMI V2.0 system supports);
558 +1. 8000ig supports video play (Only HMI V2.0 system supports);
559 +1. Text color dynamic configuration of numerical value and text input object (Only HMI V2.0 system supports);
560 +1. Dynamic screensaver (Only HMI V2.0 system supports);
561 +1. Lua SMS sending (only supported by HM I V2.0 system);
562 +1. Lua obtains SIM card information (Only HMI V2.0 system supports);
563 +1. Camera configuration (Only HMI V2.0 system supports);
564 +1. Support PI8000/PI9000 series update system without deleting project (Only HMI V2.0 system supports);
565 +1. Backstage supports multi languages switch and language customization (Only HMI V2.0 system supports);
566 +1. (((
567 +When switching languages, clean up the screen cache (Only HMI V2.0 system supports);
568 +)))
569 +1. (((
570 +Register HSW1890 triggers to refresh network signal (Only HMI V2.0 system supports);
571 +)))
572 +1. (((
573 +Register HSW1891 controls the cleaning of the screen cache (Only HMI V2.0 system supports);
574 +)))
575 +1. (((
576 +Background stimulates the terminal (Only HMI V2.0 system supports);
577 +)))
578 +1. (((
579 +**Dynamic text (Only HMI V2.0 system supports);**
580 +)))
581 +1. (((
582 +**External keyboard shortcut (Only ig series and MD series support);**
583 +)))
584 +1. (((
585 +**HMIdevice name (Only HMI V2.0 system supports);**
586 +)))
587 +1. (((
588 +**Background supports cloud server switching (Only general 8000 series with V2.0 system, ig series and MD series supports);**
589 +)))
590 +1. (((
591 +**Support remote screen adaptation display of vertical screen project (Only HMI V2.0 system supports);**
592 +)))
593 +1. (((
594 +**Common lua script function of verification algorithms (Only HMI V2.0 system supports);**
595 +)))
596 +1. (((
597 +**INSeries (IN1071, IN1072, IN1073) does not distinguish models and supports mutual projects regardless of models;**
598 +)))
599 +
600 +Driver protocol
601 +
602 +1. WECON LX6V EtherNet / IP (Tag protocol optimized version) (Only HMI V2.0 system supports);
603 +1. Rockwell EtherNet / IP (Tag protocol optimized version) (Only HMI V2.0 system supports);
604 +1. OMRON EtherNet/IP (NX/NJ Series) (Tag protocol optimized version) (Only HMI V2.0 system supports);
605 +1. MODBUS RTU Slave (All Fuction OneBaseAddress) can customize broadcast address;
606 +1. SMS module can delete all information;
607 +1. INOVANCE H5U_Easy PLC driver protocol (Serial port);
608 +1. INOVANCE H5U_Easy free tag protocol drive;
609 +1. Xinjie XD/XE drive;
610 +1. Veichi V3 drive;
611 +1. Shihlin SX6V EtherNet/IP Protocol;
612 +1. CODESYS V3 drive;
613 +1. Modbus_Server_IoT_Plat drive;
614 +1. (((
615 +MIT Q00H CPU Port PROTOCOL drive;
616 +)))
617 +1. (((
618 +Schneider TM221 drive;
619 +)))
620 +1. (((
621 +Delta_DVP_ModbusRTU drive;
622 +)))
623 +1. (((
624 +INOVANCE H5U_Easy ModbusTCP drive;
625 +)))
626 +1. (((
627 +Siemens S7-xxx Ethernet OP new drive;
628 +)))
629 +1. (((
630 +MODBUS RTU Slave (All Function) protocol retry timeout time factor multiple ToMu;
631 +)))
632 +1. (((
633 +Schneider TM221 drive;
634 +)))
635 +
636 +{{info}}
637 +**✎Note: The maximum communication number of free tag protocol and CODESYS V3 configuration in models of each series is shown in the following table.**
638 +{{/info}}
639 +
640 +|**Series model**|**Recommended maximum number of free tag protocols**|**Recommended maximum number of CODESYS V3 protocols**
641 +|8000 Series|4|Configuration is not supported.
642 +|3000 Series|Configuration is not supported.|Configuration is not supported.
643 +|9000 Series|Configuration is not supported.|Configuration is not supported.
644 +|3000i Series|Configuration is not supported.|Configuration is not supported.
645 +|ie Series (3043ies with network port)|2|Configuration is not supported.
646 +|ie Series (Other models)|Configuration is not supported.|Configuration is not supported.
647 +|3000ig Series|4|2
648 +|8000ig Series|6|2
649 +|MD3000 Series|4|Configuration is not supported.
650 +|IN Series|Configuration is not supported.|Configuration is not supported.
651 +
652 +(% class="wikigeneratedid" %)
653 +**New models**
654 +
655 +(1). ie Series: 3070ie-H;
656 +
657 +(2). IN Series: IN1071, IN1072, IN1073;
658 +
659 +(3). MD Series: MD3102;
660 +
661 +(4). ig Series: 3070ig-H, 3043ig, 8070ig, 8102ig, 8043ig;
662 +
245 245  == V8.2.95_D20220928 ==
246 246  
247 247  * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220928.zip]]
... ... @@ -302,13 +302,13 @@
302 302  1. The communication is disconnected and cannot be reconnected after ig series VPN penetrates;
303 303  1. Optimize the polling speed of VB trigger script;
304 304  
305 -Drive the updated
723 +Drive the updated
306 306  
307 307  1. The abnormal communication caused by recipe reading;
308 308  
309 309  Driver Protocol
310 310  
311 -1. Add Omron (NX/NJ) free label driver;
729 +1. Add Omron (NX/NJ) free tadriver;
312 312  
313 313  **New functions**
314 314  
... ... @@ -596,9 +596,9 @@
596 596  
597 597  = **2 Levi2PI** =
598 598  
599 -== V4.5.8 ==
1017 +== V4.6.2 ==
600 600  
601 -* [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Levi2PI.zip]]
1019 +* [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Levi2PI%20v4.6.2.zip]]
602 602  
603 603  = **3 HMI Monitor System** =
604 604  
1717728415376-899.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size