Changes for page 3 Software
Last modified by Jett on 2025/03/13 14:13
From version 19.1
edited by Devin Chen
on 2023/11/15 17:22
on 2023/11/15 17:22
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. DevinChen1 +XWiki.2454238480 - Content
-
... ... @@ -1,5 +1,101 @@ 1 1 = **1 PIStudio** = 2 2 3 += **V8.4.110_D24052802** = 4 + 5 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.66.23102001.zip]] 6 + 7 +**Bugs fixed** 8 + 9 +PC Software 10 + 11 +1. When the MQTT sending mode is set a trigger, entering the trigger address directly cannot save. 12 +1. Arc object property page configuration angle cannot enter 0. 13 +1. Add the 5V protocol first, and then add the printer's protocol, can't change the protocol of the printer. 14 +1. The value of the meter and the color of the scale are inconsistent. 15 +1. After decompile tool open, the software crash. 16 +1. Off-line emulator run time the pictures of function switch object do not display. 17 +1. After deleting multiple screens, the software crash. 18 +1. After copying the local screen successfully, the directly compiled screen objects will be smaller than the modified screen objects. 19 +1. The same project file can be opened by multiple software at the same time. 20 +1. Object id duplication. 21 +1. The bar graph does not use variables, but when compiling, it prompts the variable address error. 22 +1. The objects compile with the address error, but there is no note about what the address error is for which objects. 23 +1. When the circle/ellipse coords are in the negative area, no error message is displayed. 24 +1. When text library imports excel,the blank space and subsequent data cannot be imported. 25 +1. The function screen is deleted and then add it again.it cannot be added. 26 +1. The wrong continuous length when compiling the address of the data record. 27 +1. The wrong continuous length of lua script. 28 +1. **PI3041ig configuration Ethernet 2 does not take effect.** 29 +1. **The wrong coord prompt when the rectangular objects is determined.** 30 +1. Fix other problems. 31 + 32 +HMI Application 33 + 34 +1. The function is invalid after the function switch is pressed; 35 +1. The lua function io.open cannot open files under the u disk and sd card; 36 +1. The data record configuration data type is a string, the length is two characters, and it will be recorded more than two characters when data is collected record. 37 +1. The data type of the word switch is BCD code, and the increase and decrease do not follow the rule of the BCD code. 38 +1. "Database Format Mismatch" error after Lua script modifies table header. 39 +1. PI3070ig printing part text box printing font is not clear. 40 +1. In the offline simulation state, the graphics position offset occurs in the project with 1920*1080 resolution when the graphics are drawn by the address control. 41 +1. drawing when the graphics position offset. 42 +1. Receiving Data in Lua User Free Protocol 485 _ 2. 43 +1. Lua initialization uses the we_bas_jump screen function to jump to the screen is invalid, and there is a black screen. 44 +1. The data record cannot be recorded when the data record group id is 0. 45 +1. Value input objects check the display natural decimal function is invalid. 46 +1. To enable address control state text, must set the state sequence number, text content, and trigger settings. 47 +1. MQTT is published periodically, and changing the value of the address will also publish. 48 +1. The text on picture has a probability of becoming blurry. 49 +1. When the reset switch triggers hiding, it cannot automatically reset. 50 +1. Alarm records and data records are exported to CSV, and the table header does not switch with language switching. 51 +1. The screen alarm record csv exported using DbToCsvFile has no alarm content. 52 +1. The group number displayed in the recipe Group number address does not match the ID of the recipe display objects. 53 +1. When the number of recipe groups is set to 0, the file name address of the index does not change when there are multiple recipe files. 54 +1. The gallery is too large, causing crash. 55 +1. Drop down list username can't show multilingual. 56 +1. V-NET server anomaly causes device disconnection. 57 +1. The HMI goes off-line due to abnormal dialing of the 4G module. 58 +1. Recipe selected line ID does not match the ID in the address. 59 +1. The USB download project time is not updated, and the local time is not synchronized with the computer time. 60 +1. The keyboard screen cannot be closed normally through we_bas_closescreen function. 61 +1. The IE series uses calibri fonts and the screen display is in Song style. 62 +1. After setting floating setting as big-endian,the recipe table is displayed in Little-endian. 63 +1. Long press the bit switch, and then release the bit switch after entering the static screen saver , and the bit switch cannot be reset. 64 +1. **After the function switch uses object password, the password is invalid after the screen jumps.** 65 +1. **Some IoT cards cannot access the Internet even if they set APN.** 66 +1. Fix other problems. 67 + 68 +Drive 69 + 70 +1. DELTA AS300 MODBUS TCP driver operation D.b bit address invalid. 71 +1. OMRONE5CC driver communication abnormal. 72 +1. Xunpu printer driver prints pictures abnormally. 73 +1. Rockwell Ethernet/IP (CompactLogix Series) driver communication exception. 74 +1. Siemens LOGO drive on-line simulation crash. 75 +1. Fix other problems. 76 + 77 +**New functions** 78 + 79 +Driver 80 + 81 +1. LS MASTER Protocol driver supports bit address selection of D register. 82 +1. **TECO MP300 MODBUS TCP protocol.** 83 +1. **TECO MP300 MODBUS RTU protocol.** 84 + 85 +New models 86 + 87 +1. IN Series: IN1101 88 +1. MD Series: MD8151 89 +1. **ig Series: 3041ig, 8151ig** 90 + 91 +**Precautions** 92 + 93 +Drive 94 + 95 +**✎Note: WECON LX6V FreeTag Ethernet will not be maintained in the future, please switch to WECON LX6V EtherNet/IP.** 96 + 97 +**✎Note: WECON LX6V FreeTag Series will not be maintained in the future, please switch to Ethernet WECON LX6V EtherNet/IP** 98 + 3 3 == V8.4.66_D23102001 == 4 4 5 5 * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.66.23102001.zip]] ... ... @@ -832,10 +832,6 @@ 832 832 833 833 * [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Levi2PI%20v4.6.2.zip]] 834 834 835 -V4.5.8 836 - 837 -* [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Levi2PI.zip]] 838 - 839 839 = **3 HMI Monitor System** = 840 840 841 841 == VER: 20210317 ==
- 1717728415376-899.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.2454238480 - Size
-
... ... @@ -1,0 +1,1 @@ 1 +56.5 KB - Content