Changes for page 3 Software
Last modified by Hunter on 2026/10/24 16:44
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. joe1 +XWiki.Hunter - Content
-
... ... @@ -1,6 +1,346 @@ 1 +((( 1 1 = **1 PIStudio** = 2 2 4 +== **V10.6.45.26070101** == 3 3 6 +* Offcial Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_10.6.54.26102001.zip]] 7 + 8 +**Bugs fixed** 9 + 10 +Bugs Fixed 11 + 12 +1. BACnet protocol communication error; 13 +1. LX6V PLC program download via USB flash drive fails under certain conditions; 14 +1. Media player loading error during multi-language switching; 15 +1. Network service startup error under certain conditions; 16 +1. RH firmware update via USB flash drive fails; 17 +1. Added version verification for communication protocols; 18 +1. Optimized touch calibration for 9121ig; 19 +1. An error occurs when using bit addresses with the CAN protocol; 20 +1. Lag occurs when the address library contains a large number of entries; 21 +1. Siemens S7-1200/1500 Ethernet Expansion communication issues; 22 +1. Incomplete display of remote backend protocol driver version information; 23 +1. Offset display of multi-language static text alignment position in specific situations; 24 +1. "Insufficient space [1002]" error message when downloading the project in specific situations; 25 +1. Upload failure after exceeding the number of incorrect password attempts; 26 +1. Abnormal display size of Alarm Record and Recipe record on the web page monitoring; 27 +1. 4G card not recognized by 4G module; 28 +1. Communication fails of 485_2 for i series; 29 +1. Real-time trend chart data not displayed under specific configurations; 30 +1. Pie chart not update in specific situations; 31 +1. The function switch does not work when Minimum hold time, object level, and activate on release are enabled simultaneously; 32 +1. Email SMTP address field input limitation; 33 +1. Issues with user permission operation logs in old project; 34 +1. Image sizes are saved incorrectly in the picture library for IN series models; 35 +1. Screen content is missing during offline simulation under certain conditions after editing bit alarms, alarm record objects; 36 +1. Vigor WC register type error; 37 +1. MIT iQ-L Series CPU MELSEC PROTOCOL X register type range issue; 38 + 39 +**New models** 40 + 41 + 42 +1. IN Series: IN1071-H; 43 +1. ig Series: 9156ig; 44 + 45 +== **V10.6.45.26070101** == 46 + 47 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/PIStudio_10.6.45.26070101.zip]] 48 + 49 +**Bugs fixed** 50 + 51 +1. Object -level password check option “Becomes the lowest level”; 52 +1. Static IP inaccessible after VPN pass-through; 53 +1. Multi-language switching not supported when exporting alarm record files; 54 +1. Some fonts displayed offset in remote screens; 55 +1. Indirect screens displayed abnormally in Remote monitoring; 56 +1. Some fonts displayed abnormally; 57 +1. Connecting Easy521 with INOVANCE H5U PLC via Ethernet protocol causes partial register addresses to fail to be read on the screen; 58 +1. RH-WG-LA unable to communicate with LX6C via WiFi; 59 +1. S7-1200 protocol string data issue; 60 +1. After a project is set to read-only mode, other projects cannot be opened afterward; 61 +1. Background function custom parameter display failure; 62 +1. Multi-layer nested indirect screens displayed abnormally; 63 +1. Indirect screens flickered when screen switching; 64 +1. Alarm Runbar failed to display blank spaces for alarms; 65 +1. Freetag communication indicator showed incorrect status; 66 +1. OPC UA client crash caused by repeated connection; 67 +1. Communication failure of SIEMENS AGLink protocol via Ethernet2; 68 +1. The KEYENCE KV-5000 protocol incomplete device address range. 69 +1. AB CompactLogix communication failure; 70 +1. Sub-screens not fully displayed when zoomed in; 71 +1. The popup of the function switch configuration interface shows coordinate position setting error; 72 +1. Inappropriate translation in some configuration screens; 73 +1. Modifying the hidden bit address of a text object will clear the text content; 74 +1. A beep still sounds when clicking after the drop-down list is hidden; 75 +1. Errors occur when a static IP is configured in the background without DNS setup; 76 +1. File list select-all copy-paste operation failed; 77 +1. Some special symbols displayed abnormally in Runbar messages; 78 +1. Meter object digital status failed to display normally; 79 +1. Alarm record display filter cumulative time and occurrence count sorting ineffective; 80 +1. Alarm record row space color setting ineffective; 81 +1. BACnet driver-related issues; 82 +1. H5U Ethernet protocol communication timeout problem; 83 +1. "Not created by this software" when opening projects in specific conditions; 84 +1. Bit alarm import anomaly in specific conditions; 85 +1. When the project has multiple templates, only one can be displayed in specific conditions; 86 +1. Private deployment URL configuration failure in specific conditions; 87 +1. No compilation error occurs after removing an address from the address library; 88 +1. Using the address list replacement function clears VB scripts; 89 +1. OMRON PLC communication timeout; 90 +1. Indirect screens flickered when screen switching; 91 +1. High delay in message prompt popups in specific conditions; 92 +1. Failed to connect to encrypted MQTT servers; 93 +1. MQTT publish error in Lua script; 94 +1. Communication failure between RH-WG-LA and LX6C via Wi-Fi. 95 +1. Communication anomaly in INOVANCE H5U PLC Ethernet protocol in specific conditions; 96 +1. SMS sending error in Lua script; 97 +1. Timeout occurs when continuously writing over 800 addresses to SCHNEIDER M221 PLC via Ethernet; 98 +1. Optimize loading speed of numeric input and text input controls; 99 +1. Optimize layout and style of background interface; 100 +1. Optimize loading speed of background WIFI configuration page; 101 +1. Optimize background prompt messages; 102 +1. Optimize communication efficiency of free tags; 103 +1. New calibration interface; 104 +1. Optimize click response speed of dropdown list; 105 +1. Optimize loading speed of alarm data during device startup; 106 +1. Other issues; 107 + 108 +**New functions** 109 + 110 +**PC software** 111 + 112 +1. Added: MQTT multi-server configuration; 113 +1. Add downloaded project path and update version No. for device management tool title; 114 +1. Europe 2.0 server option 115 + 116 +**HMI application** 117 + 118 +1. Display user storage space in background; 119 +1. Background online upgrade channel; 120 +1. Support European V2.0 server configuration in background; 121 +1. Register HSW2108 sets the scrollbar width of dropdown list; 122 +1. Lua interface for device name configuration; 123 +1. Register HSW893 controls synchronous/asynchronous mode of user permission between web terminal and touch screen terminal; 124 +1. Lua interface for selecting sound card of TTS voice playback; 125 +1. Registers HSW11829 and HSW11830 control keyboard mask transparency; 126 +1. Register HSW11831 controls enable/disable of long-press countdown animation effect; 127 +1. Optimize built-in virtual keyboard to support continuous text input after pressing backspace key; 128 + 129 +**New drive** 130 + 131 +1. KEYENCE KV-7000/8000 (Ethernet); 132 +1. Siemens S7-1200 Ethernet new protocol adds DBxDBLW four-word register; 133 +1. Siemens S7-200 Smart (Ethernet) V3/G2 drive; 134 +1. MIT Q Series CPU MELSEC PROTOCOL; 135 +1. MIT iQ-L Series CPU MELSEC PROTOCOL; 136 +1. MIT iQ-R Series CPU MELSEC PROTOCOL; 137 +))) 138 + 139 +((( 140 +== **V10.5.45.25102301(New available modules: PI9000ig, RL, RH, WP)** == 141 +))) 142 + 143 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_10.5.zip]] 144 + 145 +(% class="wikigeneratedid" %) 146 +**Bugs fixed** 147 + 148 +1. Slow response issue with IN series HMI; 149 +1. Slow response of alarm record and address monitoring table, and stuck when opening the project; 150 +1. LREAL data type cannot be read and written; 151 +1. The overlapping screen cannot be set when the sub-screen is selected in screen; 152 +1. The encoding method options for string type data in Data record; 153 +1. Communication failure on Ethernet2 of HMI when using IP address from different Subnets for Ethernet1 and Ethernet2. 154 +1. The addresses of X and Y are inconsistent in XY trend chart,; 155 +1. Object lock cannot be an index address; 156 +1. Lagging display of camera; 157 +1. Stuck on logo issue during IN, IE series upgrade; 158 +1. The IN series HMI do not support the mouse style configuration; 159 +1. Failure to download projects to IN series HMI ; 160 +1. PDF prompts display abnormal; 161 +1. CAN port configuration communication error; 162 +1. When RH device uses 4K resolution, the fonts of message prompt, background, etc. are too small; 163 +1. The issue of translator multi-language; 164 +1. Invalid address mapping; 165 +1. The advanced configuration effect of device search, device management and cloud management download project not match the expected results; 166 +1. RH-00 communication configuration does not have ETH2 configuration; 167 +1. The ig model system keyboard is not working; 168 +1. The ig, RH series vertical screen mouse movement and touch optimized; 169 +1. 4.3-inch HMI vertical screen background display effect; 170 +1. Issue of Siemens S7-1200 DBS register reads and writes less than half, need to check the ”Read DWord” option; 171 +1. OPC UA Client reads and writes strings issue, if the new string is shorter than the old one, the end of the old string will be remained; 172 +1. If using too many element in recipe for JUNCAUTO protocol, the address will be clean and overwrite the data in low addresses; 173 +1. Write LX5V bit-in-word; 174 +1. OPC UA Client cannot connect to the server configured with authentication; 175 +1. OPC UA Client cannot reconnect normally after unplugging/plugging the network cable; 176 +1. Changing communication methods in the background is invalid; 177 +1. Set user permissions on the screen, but the register cannot jump to this screen; 178 +1. The issue of abnormal using indirect screen on sub-screen; 179 +1. Abnormal display of the bar graph ; 180 +1. The RH series cannot use the CODESYS protocol; 181 +1. When the simulator's print object is set to screenshot mode, the screen cannot be switched after a screenshot. 182 +1. Operation records do not support text variable insert; 183 +1. Object or font shrinking when moving numeric object; 184 +1. CODESYS V3 protocol cannot read the Unicode string of LX6C (WSTRING); 185 +1. The issue with the UNION type data in Omron; 186 +1. Communication failure after the end of VPN pass-through, ; 187 +1. Communication failure between Keyence KV series protocol and 9000ig series; 188 +1. Gallery size limitation per screen for IN, IE and RH series; 189 +1. Other issues; 190 + 191 +(% class="wikigeneratedid" %) 192 +**New functions** 193 + 194 +(% class="wikigeneratedid" %) 195 +PC Software 196 + 197 +1. Software style selection; 198 +1. Screen layer; 199 +1. Template screen; 200 +1. Project tree objects list; 201 +1. Software settings page; 202 +1. The color palette adds a color picker; 203 +1. Address priority configuration; 204 +1. German is added to the software language; 205 +1. Automatic project backup; 206 +1. Address list search replacement; 207 +1. Import and export of user login information; 208 +1. The toolbar adds an upload project entrance and a toolbox entrance; 209 +1. UI enhancement; 210 +1. Software toolbar layout optimized; 211 +1. Address compilation optimized; 212 +1. Address integration optimized; 213 +1. Project multi-language translation(Only Baidu API key); 214 +1. Sound library configuration; 215 +1. BACNet server; 216 +1. Address search and replace; 217 +1. String table text alignment; 218 +1. Support for string table configuration 219 +1*. Drop-down list; 220 +1*. Data Record (channel name); 221 +1*. Recipe(element name); 222 +1*. Bit alarm text; 223 +1*. Word alarm text; 224 +1. Object copy attributes (font/size/color) to other languages; 225 +1. Project format upgrade.(.pi to .pi2) 226 +1. After the communication port connection is deleted, the communication port number is automatically sorted; 227 +1. Sub-screen pops up coordinate configuration; 228 +1. Alarm address communication priority (import/export); 229 +1. Text tag function; 230 +1. Text position vertical adjustment; 231 +1. Beckhoff tag import filtering; 232 +1. Schedule ; 233 +1. Column Chart object; 234 +1. Improve the success rate of pass-through; 235 + 236 +(% class="wikigeneratedid" %) 237 +HMI Application 238 + 239 +1. NTP time synchronization; 240 +1. New touch calibration interface; 241 +1. Sub screen modal mode; 242 +1. Exclusive operation; 243 +1. Watchdog; 244 +1. New Alarm Record; 245 +1*. New alarm record interface; 246 +1*. Alarm record ascending/descending order; 247 +1*. Alarm record statistics; 248 +1*. Diverse Alarm record styles; 249 +1. Media player; 250 +1. Mouse cursor style; 251 +1. Timeout NC effect; 252 +1. Sub-screen drag-and-drop; 253 +1. Minimum pressing interval time countdown tips UI; 254 +1. Additional options for trigger write addresses in alarm records; 255 +1. UNICODE and GBK display format are added to alarm variables; 256 +1. User permissions can configure the time of auto logout; 257 +1. Text-To-Speech; 258 +1. Voice broadcast; 259 +1. The message prompt module supports 48 languages; 260 +1. Remote management module in the background; 261 +1*. Remote background; 262 +1*. Access verification; 263 +1*. IP Whitelist/Blacklist; 264 +1*. Access log viewing; 265 +1. Configure network routing mode, switch mode and WIFI hotspot in the background 266 +1. RH series, 9000ig series DIP switch function 267 +1*. Factory reset 268 +1*. Touch calibration adaptation; 269 +1. Vertical alignment method for text display; 270 +1. Column Chart; 271 +1. Text tag function; 272 +1. Supports control via special registers to adjust the button size and spacing on the new Alarm record object, new Recipe Record object, and Column Chart; 273 +1. The text for email content, user login (username), user login (description), and log message text (operation records) supports configuration via a string table. 274 +1. Task scheduler; 275 +1. Sub-screen pop-up position optimization; 276 +1. RE and RL series support NTP (network time protocol) function; 277 + 278 +(% class="wikigeneratedid" %) 279 +**New drive** 280 + 281 +1. Winding Machine MODBUS RTU Winder; 282 +1. KEYENCE EtherNet/IP (KV-8000); 283 +1. KEYENCE EtherNet/IP (KV-X310); 284 +1. KEYENCE EtherNet/IP (KV-X520); 285 +1. INOVANCE H5U PLC Ethernet FreeTag (fast) replaces INOVANCE H5U PLC Ethernet FreeTag ; 286 +1. Siemens Ethernet FreeTag (S7 Series); 287 +1. LAICARD RFID Reader; 288 +1. KEYENCE Scanner HR-100B; 289 +1. KEYENCE Scanner HR-100; 290 +1. RONGSHI RFID Reader; 291 +1. KCJ RFID Reader; 292 +1. BACnet_IP; 293 +1. HONEYWELL Scanner 1902-C; 294 +1. Read interval time setting (RwDelay register) for modbus rtu slave. 295 +1. Expanded SD,SM register address range (up to 511) for INVT_IVC1. 296 +1. Leadshine LEISHINE _ SC-C32A4DS ModbusTcp; 297 +1. Leadshine LEISHINE _ SC-C32A4DS ModbusRTU; 298 +1. FANUC protocol; 299 +1. NEWLAND Scanner; 300 +1. NEWLAND Scanner COM; 301 +1. Leadshine LEISHINE _ LC1000 _ Series _ TCP; 302 +1. Leadshine LEISHINE _ LC1000 _ Series _ RTU; 303 +1. ModBus RTU Slave (All Fuction)~-~-RwDelay register for controlling send/receive interval; 304 +1. MITSUBISHI FX5U Ethernet—Bit-in-Word; 305 +1. Expanded SD, SM register range for INVT_IVC1 protocol; 306 +1. New CODESYS V3 protocol-read Unicode strings (WSTRING data type); 307 + 308 +(% class="wikigeneratedid" %) 309 +**New models** 310 + 311 +1. GB series: GB3041, GB3070, GB3101, GB8041, GB8070-H, GB8101; 312 +1. ig series: PI9102ig, PI9121ig, PI9150ig, PI9151ig; 313 +1. WP series: WP2070, WP2071, WP3070, WP3071; 314 +1. MD series: MD8102; 315 +1. RL series: RL-G, RL-WF; 316 +1. RH series: RH-00, RH-00-4K, RH-AG, RH-G, RH-W, RH-WG, RH-WG-CNC, RH-WG-E, RH-WG-LA, RH-WIFI; 317 + 318 +== **V9.5.9.25091702** == 319 + 320 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.5.9.25091702.zip]] 321 + 322 +(% class="box errormessage" %) 323 +((( 324 +**Notice** 325 + 326 +1. The new version can not support general series(PI3000,PI8000,PI9000). Please use the old version (Release Build VER:R05R998_V8.4.114_D24061301) to program the general series. 327 +1. **After the upgrade, only the ig series can use the Lua MQTT library.** 328 +1. Projects opened with the new version cannot be opened with the old version. Please make sure to back up the project. 329 +1. After the upgrade, the supported protocols will change. PI3000ig can not support the third-part Free-tags Protocol.**For details, please refer to: [[Limitation of the Ethernet communication protocol - Wecon>>url:https://docs.we-con.com.cn/bin/view/PIStudio/PLC Protocol/Limitation of the Ethernet communication protocol/]]** 330 +1. Cannot roll back the version after upgrading. 331 +))) 332 + 333 +**Bugs fixed** 334 + 335 +1. i Series 485_2 communication issues; 336 +1. Pie chart control lag issues under certain circumstances; 337 +1. Remote monitoring issues with the mobile app and PC client software causing link errors; 338 +1. Other issues; 339 + 340 +**New functions** 341 + 342 +Cloud configuration supports Asian 2.0 servers; 343 + 4 4 == **V9.4.13.25053001** == 5 5 6 6 * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.4.13.25053001.zip]] ... ... @@ -748,7 +748,7 @@ 748 748 749 749 == V8.2.95_D20220928 == 750 750 751 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio2 0220928.zip]]1091 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.2.95.22092802.zip]] 752 752 753 753 (% class="wikigeneratedid" id="HBugsfixed" %) 754 754 **Bugs fixed** ... ... @@ -1112,5 +1112,6 @@ 1112 1112 1113 1113 = **4 StartupLogoTool** = 1114 1114 1455 +* V3.0.24: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/StartupLogoTool%20v3.0.24.zip]] (Support RH series) 1115 1115 * V3.0.19: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/StartupLogoTool%20V3.0.19.zip]] 1116 1116 * old version: [[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]