Changes for page 3 Software

Last modified by Jett on 2025/03/13 14:13

From version 20.1
edited by Devin Chen
on 2023/11/15 17:23
Change comment: There is no comment for this version
To version 39.1
edited by Jett
on 2025/03/12 11:38
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.DevinChen
1 +XWiki.2454238480
Content
... ... @@ -1,5 +1,234 @@
1 1  = **1 PIStudio** =
2 2  
3 +== **V9.3.2.25030401** ==
4 +
5 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.1.18.24122702.zip]]
6 +
7 +(% class="box errormessage" %)
8 +(((
9 +**Notice**
10 +
11 +1. The new version can not support general series(PI3000,PI8000,PI9000). Please use the old version (Release Build VER:R05R998_V8.4.114_D24061301) to program the general series.
12 +1. Projects opened with the new version cannot be opened with the old version. Please make sure to back up the project.
13 +1. After the upgrade, the supported protocols will change. PI3000ig can not support the third-part Free-tags Protocol.**For details, please refer to: [[Limitation of the Ethernet communication protocol - Wecon>>url:https://docs.we-con.com.cn/bin/view/PIStudio/PLC Protocol/Limitation of the Ethernet communication protocol/]]**
14 +1. Cannot roll back the version after upgrading.
15 +)))
16 +
17 +**Bugs fixed**
18 +
19 +1. Rectangle object disappear when using color control function.
20 +1. ie series can not use the Indirect addressing function.
21 +1. gif images are stuck when used.
22 +1. APN cannot be saved correctly in 4G Setting.
23 +1. About time span of the alarm record display,the value in LAN monitoring does not match the actual value.
24 +1. The new recipe tool displays anomalies in LAN Monitoring
25 +1. Recipe data cannot be saved when downloading the project via USB
26 +1. Communication problem between ie series and 5V PLC.
27 +1. Communication error with Omron PLC after RE/RH series restart.
28 +1. The string display error for the Siemens S7-1200 protocol.
29 +1. Mobile data consumption is abnormal when HMI is connected to the cloud via 4G.
30 +1. Fix other bug.
31 +1. Optimized shape gallery content.
32 +1. Optimized some of communication protocols.
33 +
34 +**New functions**
35 +
36 +1. The drop-down list triggers the beeper function
37 +1.
38 +
39 +**New model**
40 +
41 +1. PI8102ig-H
42 +
43 +== **V9.1.18.24122702** ==
44 +
45 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.1.18.24122702.zip]]
46 +
47 +(% class="box errormessage" %)
48 +(((
49 +**Notice**
50 +
51 +1. The new version can not support general series(PI3000,PI8000,PI9000). Please use the old version (Release Build VER:R05R998_V8.4.114_D24061301) to program the general series.
52 +1. Projects opened with the new version cannot be opened with the old version. Please make sure to back up the project.
53 +1. After the upgrade, the supported protocols will change. PI3000ig can not support the third-part Free-tags Protocol.**For details, please refer to: [[Limitation of the Ethernet communication protocol - Wecon>>url:https://docs.we-con.com.cn/bin/view/PIStudio/PLC Protocol/Limitation of the Ethernet communication protocol/]]**
54 +1. Cannot roll back the version after upgrading.
55 +)))
56 +
57 +**Bugs fixed**
58 +
59 +1. RE series V-BOX PLC Pass-through sometime can't work properly.
60 +1. RE series V-BOX data record upload can't work properly.
61 +1. PI8043ig and PI3041ig recipe object unable to display properly in web side.
62 +1. When entering the backstage for the first time after the screen is restarted, the first digit of the backstage password is invalid.
63 +1. PI8043ig project file is too large to the logo is stuck when HMI restarted.
64 +1. WIFI model can not enable after update the system.
65 +1. HMI crash and freeze when downloading PLC project.
66 +1. When the rectangle/arc/circle object is first initialized, a shadow will appears.
67 +1. The cloud icon in backstage state error.
68 +1. In off-line simulation.The left lable of Numeric Input/Display object affect natural decimal display.
69 +1. MQTT tool publish bit address,the length setting is not 1,message error.
70 +1. MQTT V5 protocol cannot automatically connect after network disconnection.
71 +1. The cloud management tool cannot log in to non-administrator users normally.
72 +1. Object lock does not work for bit switch momentary mode.
73 +1. WIFI is not connected, but IP still exists.
74 +1. The actual minimum pressing time of the function switch does not match the setting.
75 +1. RH-WF V-BOX indicator lamp display error.
76 +1. Data record display object start time setting error.
77 +1. The camera display object disappear after switching screens.
78 +1. After using the four arithmetic operations in address mapping, reading the value in read-only mode displays an abnormality.
79 +1. Object level password does not match the setting.
80 +1. In offline simulation, the new recipe tool crashes by clicking keyboard letters.
81 +1. Recipe name changes when switching screens.
82 +1. PLC program upload fails when PLC Pass-Through.
83 +1. IDEC MicroSmart Protocol:TC CC register modifying the value of the address results in an error in the value of the next address.
84 +1. Delta_AS300_TCP Protocol:D.b register cannot modify status.
85 +1. OPCUA Client:communication error but have no time-out message.
86 +1. IEC104client:HMI get black screen after downloading this protocol.
87 +
88 +**New functions**
89 +
90 +PC Software
91 +
92 +1. New project properties page.
93 +1. i/ie/ig/IN/RE/RH series all support screen style.
94 +1. Download tool support RE,RH series flash light and test network.
95 +1. New Device management tool.
96 +1. Software homepage embedded Wecon support center.
97 +1. Allow configuration preserve network configuration when download the project.
98 +1. Software online update.
99 +1. Scada canvas extension, new draft area.
100 +1. Recipe element support bit address.
101 +1. OPC UA server.
102 +1. New X,Y internal registers(RH series).
103 +1. 3000ig series Limitation of the Ethernet communication protocol up to 32.
104 +
105 +HMI Application
106 +
107 +1. New recipe object-Recipe Record:Integrated search, add, delete, download, upload, import, export, and switch recipe functions.
108 +1. New backstage:The background can be exited instead of restarted,New UI,Ethernet download PLC program,USB update support update the system and project at the same time.
109 +1. Remote backstage.
110 +1. New system keyboard.
111 +1. Character Input/Display object support multi line display.
112 +1. Character Input/Display object support choose data format(UTF-8/GBK/UNICODE).
113 +1. Numeric Input/Display object support more 64bit data format.
114 +1. Modification of serial port parameters takes effect immediately.
115 +1. RE series can be bound to V-NET.
116 +1. lua script open user permission function interface.
117 +1. New Multi-link function.
118 +1. New special registers related to automatic logout of user functionse.
119 +1. Alarm info support multiple variables.
120 +1. Min.hold time countdown.
121 +1. ig-O support Wecon 6V freetags protocol and CODESYS V3 protocol.
122 +1. (((
123 +New special registers related to displaying user storage space information.
124 +)))
125 +
126 +Driver protocol
127 +
128 +1. OPCUA Client.
129 +1. Siemens S7-1200/1500 Ethernet FreeTag.
130 +1. TwinCAT PLC Ethernet.
131 +1. KEYENCE KV-5000(Ethernet) using bit address in word address.
132 +
133 +**New model**
134 +
135 +1. RE series:RE-00,RE-00-LA,RE-4G,RE-4G-LA
136 +1. RH series:RH-WIFI
137 +1. ig series:PI3101ig,PI8101ig,PI8121ig
138 +
139 +== **V8.4.114_D24061301** ==
140 +
141 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.114.24061301.zip]]
142 +
143 +**Bugs fixed**
144 +
145 +PC Software
146 +
147 +1. When the MQTT sending mode is set a trigger, entering the trigger address directly cannot save.
148 +1. Arc object property page configuration angle cannot enter 0.
149 +1. Add the 5V protocol first, and then add the printer's protocol, can't change the protocol of the printer.
150 +1. The value of the meter and the color of the scale are inconsistent.
151 +1. After decompile tool open, the software crash.
152 +1. Off-line emulator run time the pictures of function switch object do not display.
153 +1. After deleting multiple screens, the software crash.
154 +1. After copying the local screen successfully, the directly compiled screen objects will be smaller than the modified screen objects.
155 +1. The same project file can be opened by multiple software at the same time.
156 +1. Object id duplication.
157 +1. The bar graph does not use variables, but when compiling, it prompts the variable address error.
158 +1. Using dynamic recipients, email addresses are not compiled and display recipient errors.
159 +1. The objects compile with the address error, but there is no note about what the address error is for which objects.
160 +1. When the circle/ellipse coords are in the negative area, no error message is displayed.
161 +1. When text library imports excel,the blank space and subsequent data cannot be imported.
162 +1. The function screen is deleted and then add it again.it cannot be added.
163 +1. The wrong continuous length when compiling the address of the data record.
164 +1. The wrong continuous length of lua script.
165 +1. PI3041ig configuration Ethernet 2 does not take effect.
166 +1. The wrong coord prompt when the rectangular objects is determined.
167 +1. The data record storage in project setting is error.
168 +1. Fix other problems.
169 +
170 +HMI Application
171 +
172 +1. The function is invalid after the function switch is pressed;
173 +1. The lua function io.open cannot open files under the u disk and sd card;
174 +1. The data record configuration data type is a string, the length is two characters, and it will be recorded more than two characters when data is collected record.
175 +1. The data type of the word switch is BCD code, and the increase and decrease do not follow the rule of the BCD code.
176 +1. "Database Format Mismatch" error after Lua script modifies table header.
177 +1. PI3070ig printing part text box printing font is not clear.
178 +1. In the offline simulation state, the graphics position offset occurs in the project with 1920*1080 resolution when the graphics are drawn by the address control.
179 +1. drawing when the graphics position offset.
180 +1. Receiving Data in Lua User Free Protocol 485 _ 2.
181 +1. Lua initialization uses the we_bas_jump screen function to jump to the screen is invalid, and there is a black screen.
182 +1. The data record cannot be recorded when the data record group id is 0.
183 +1. Value input objects check the display natural decimal function is invalid.
184 +1. To enable address control state text, must set the state sequence number, text content, and trigger settings.
185 +1. MQTT is published periodically, and changing the value of the address will also publish.
186 +1. The text on picture has a probability of becoming blurry.
187 +1. When the reset switch triggers hiding, it cannot automatically reset.
188 +1. Alarm records and data records are exported to CSV, and the table header does not switch with language switching.
189 +1. The screen alarm record csv exported using DbToCsvFile has no alarm content.
190 +1. The group number displayed in the recipe Group number address does not match the ID of the recipe display objects.
191 +1. When the number of recipe groups is set to 0, the file name address of the index does not change when there are multiple recipe files.
192 +1. The gallery is too large, causing crash.
193 +1. Drop down list username can't show multilingual.
194 +1. V-NET server anomaly causes device disconnection.
195 +1. The HMI goes off-line due to abnormal dialing of the 4G module.
196 +1. Recipe selected line ID does not match the ID in the address.
197 +1. The USB download project time is not updated, and the local time is not synchronized with the computer time.
198 +1. The keyboard screen cannot be closed normally through we_bas_closescreen function.
199 +1. The IE series uses calibri fonts and the screen display is in Song style.
200 +1. After setting floating setting as big-endian,the recipe table is displayed in Little-endian.
201 +1. Long press the bit switch, and then release the bit switch after entering the static screen saver , and the bit switch cannot be reset.
202 +1. After the function switch uses object password, the password is invalid after the screen jumps.
203 +1. PI8150ig makes the font size smaller when using calibri font.
204 +1. IN series long press upper left corner, upper right corner invalid.
205 +1. Fix other problems.
206 +
207 +Drive
208 +
209 +1. DELTA AS300 MODBUS TCP driver operation D.b bit address invalid.
210 +1. OMRONE5CC driver communication abnormal.
211 +1. Xunpu printer driver prints pictures abnormally.
212 +1. Rockwell Ethernet/IP (CompactLogix Series) driver communication exception.
213 +1. Siemens LOGO drive on-line simulation crash.
214 +1. Fix other problems.
215 +
216 +**New functions**
217 +
218 +Driver
219 +
220 +1. LS MASTER Protocol driver supports bit address selection of D register.
221 +1. TECO MP300 MODBUS TCP protocol.
222 +1. TECO MP300 MODBUS RTU protocol.
223 +
224 +**Precautions**
225 +
226 +Drive 
227 +
228 +✎Note: WECON LX6V FreeTag Ethernet will not be maintained in the future, please switch to WECON LX6V EtherNet/IP.
229 +
230 +✎Note: WECON LX6V FreeTag Series will not be maintained in the future, please switch to Ethernet WECON LX6V EtherNet/IP
231 +
3 3  == V8.4.66_D23102001 ==
4 4  
5 5  * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.66.23102001.zip]]
... ... @@ -832,10 +832,6 @@
832 832  
833 833  * [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Levi2PI%20v4.6.2.zip]]
834 834  
835 -== V4.5.8 ==
836 -
837 -* [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Levi2PI.zip]]
838 -
839 839  = **3 HMI Monitor System** =
840 840  
841 841  == VER: 20210317 ==
1717728415376-899.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +56.5 KB
Content