Changes for page 3 Software

Last modified by Jett on 2025/03/13 14:13

From version 23.1
edited by Jett
on 2024/06/07 10:51
Change comment: There is no comment for this version
To version 21.1
edited by Devin Chen
on 2023/11/15 17:23
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.2454238480
1 +XWiki.DevinChen
Content
... ... @@ -1,101 +1,5 @@
1 1  = **1 PIStudio** =
2 2  
3 -= **V8.4.110_D24052802** =
4 -
5 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.110.24052802.zip]]
6 -
7 -**Bugs fixed**
8 -
9 -PC Software
10 -
11 -1. When the MQTT sending mode is set a trigger, entering the trigger address directly cannot save.
12 -1. Arc object property page configuration angle cannot enter 0.
13 -1. Add the 5V protocol first, and then add the printer's protocol, can't change the protocol of the printer.
14 -1. The value of the meter and the color of the scale are inconsistent.
15 -1. After decompile tool open, the software crash.
16 -1. Off-line emulator run time the pictures of function switch object do not display.
17 -1. After deleting multiple screens, the software crash.
18 -1. After copying the local screen successfully, the directly compiled screen objects will be smaller than the modified screen objects.
19 -1. The same project file can be opened by multiple software at the same time.
20 -1. Object id duplication.
21 -1. The bar graph does not use variables, but when compiling, it prompts the variable address error.
22 -1. The objects compile with the address error, but there is no note about what the address error is for which objects.
23 -1. When the circle/ellipse coords are in the negative area, no error message is displayed.
24 -1. When text library imports excel,the blank space and subsequent data cannot be imported.
25 -1. The function screen is deleted and then add it again.it cannot be added.
26 -1. The wrong continuous length when compiling the address of the data record.
27 -1. The wrong continuous length of lua script.
28 -1. **PI3041ig configuration Ethernet 2 does not take effect.**
29 -1. **The wrong coord prompt when the rectangular objects is determined.**
30 -1. Fix other problems.
31 -
32 -HMI Application
33 -
34 -1. The function is invalid after the function switch is pressed;
35 -1. The lua function io.open cannot open files under the u disk and sd card;
36 -1. The data record configuration data type is a string, the length is two characters, and it will be recorded more than two characters when data is collected record.
37 -1. The data type of the word switch is BCD code, and the increase and decrease do not follow the rule of the BCD code.
38 -1. "Database Format Mismatch" error after Lua script modifies table header.
39 -1. PI3070ig printing part text box printing font is not clear.
40 -1. In the offline simulation state, the graphics position offset occurs in the project with 1920*1080 resolution when the graphics are drawn by the address control.
41 -1. drawing when the graphics position offset.
42 -1. Receiving Data in Lua User Free Protocol 485 _ 2.
43 -1. Lua initialization uses the we_bas_jump screen function to jump to the screen is invalid, and there is a black screen.
44 -1. The data record cannot be recorded when the data record group id is 0.
45 -1. Value input objects check the display natural decimal function is invalid.
46 -1. To enable address control state text, must set the state sequence number, text content, and trigger settings.
47 -1. MQTT is published periodically, and changing the value of the address will also publish.
48 -1. The text on picture has a probability of becoming blurry.
49 -1. When the reset switch triggers hiding, it cannot automatically reset.
50 -1. Alarm records and data records are exported to CSV, and the table header does not switch with language switching.
51 -1. The screen alarm record csv exported using DbToCsvFile has no alarm content.
52 -1. The group number displayed in the recipe Group number address does not match the ID of the recipe display objects.
53 -1. When the number of recipe groups is set to 0, the file name address of the index does not change when there are multiple recipe files.
54 -1. The gallery is too large, causing crash.
55 -1. Drop down list username can't show multilingual.
56 -1. V-NET server anomaly causes device disconnection.
57 -1. The HMI goes off-line due to abnormal dialing of the 4G module.
58 -1. Recipe selected line ID does not match the ID in the address.
59 -1. The USB download project time is not updated, and the local time is not synchronized with the computer time.
60 -1. The keyboard screen cannot be closed normally through we_bas_closescreen function.
61 -1. The IE series uses calibri fonts and the screen display is in Song style.
62 -1. After setting floating setting as big-endian,the recipe table is displayed in Little-endian.
63 -1. Long press the bit switch, and then release the bit switch after entering the static screen saver , and the bit switch cannot be reset.
64 -1. **After the function switch uses object password, the password is invalid after the screen jumps.**
65 -1. **Some IoT cards cannot access the Internet even if they set APN.**
66 -1. Fix other problems.
67 -
68 -Drive
69 -
70 -1. DELTA AS300 MODBUS TCP driver operation D.b bit address invalid.
71 -1. OMRONE5CC driver communication abnormal.
72 -1. Xunpu printer driver prints pictures abnormally.
73 -1. Rockwell Ethernet/IP (CompactLogix Series) driver communication exception.
74 -1. Siemens LOGO drive on-line simulation crash.
75 -1. Fix other problems.
76 -
77 -**New functions**
78 -
79 -Driver
80 -
81 -1. LS MASTER Protocol driver supports bit address selection of D register.
82 -1. **TECO MP300 MODBUS TCP protocol.**
83 -1. **TECO MP300 MODBUS RTU protocol.**
84 -
85 -New models
86 -
87 -1. IN Series: IN1101
88 -1. MD Series: MD8151
89 -1. **ig Series: 3041ig, 8151ig**
90 -
91 -**Precautions**
92 -
93 -Drive 
94 -
95 -**✎Note: WECON LX6V FreeTag Ethernet will not be maintained in the future, please switch to WECON LX6V EtherNet/IP.**
96 -
97 -**✎Note: WECON LX6V FreeTag Series will not be maintained in the future, please switch to Ethernet WECON LX6V EtherNet/IP**
98 -
99 99  == V8.4.66_D23102001 ==
100 100  
101 101  * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.66.23102001.zip]]
1717728415376-899.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.2454238480
Size
... ... @@ -1,1 +1,0 @@
1 -56.5 KB
Content