Changes for page 3 Software

Last modified by Jett on 2025/03/13 14:13

From version 24.1
edited by Jett
on 2024/06/07 11:35
Change comment: There is no comment for this version
To version 16.5
edited by Mora Zhou
on 2023/10/27 09:55
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.2454238480
1 +XWiki.Mora
Content
... ... @@ -1,102 +1,5 @@
1 1  = **1 PIStudio** =
2 2  
3 -= **V8.4.110_D24052802** =
4 -
5 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.110.24052802.zip]]
6 -
7 -**Bugs fixed**
8 -
9 -PC Software
10 -
11 -1. When the MQTT sending mode is set a trigger, entering the trigger address directly cannot save.
12 -1. Arc object property page configuration angle cannot enter 0.
13 -1. Add the 5V protocol first, and then add the printer's protocol, can't change the protocol of the printer.
14 -1. The value of the meter and the color of the scale are inconsistent.
15 -1. After decompile tool open, the software crash.
16 -1. Off-line emulator run time the pictures of function switch object do not display.
17 -1. After deleting multiple screens, the software crash.
18 -1. After copying the local screen successfully, the directly compiled screen objects will be smaller than the modified screen objects.
19 -1. The same project file can be opened by multiple software at the same time.
20 -1. Object id duplication.
21 -1. The bar graph does not use variables, but when compiling, it prompts the variable address error.
22 -1. Using dynamic recipients, email addresses are not compiled and display recipient errors.
23 -1. The objects compile with the address error, but there is no note about what the address error is for which objects.
24 -1. When the circle/ellipse coords are in the negative area, no error message is displayed.
25 -1. When text library imports excel,the blank space and subsequent data cannot be imported.
26 -1. The function screen is deleted and then add it again.it cannot be added.
27 -1. The wrong continuous length when compiling the address of the data record.
28 -1. The wrong continuous length of lua script.
29 -1. **PI3041ig configuration Ethernet 2 does not take effect.**
30 -1. **The wrong coord prompt when the rectangular objects is determined.**
31 -1. Fix other problems.
32 -
33 -HMI Application
34 -
35 -1. The function is invalid after the function switch is pressed;
36 -1. The lua function io.open cannot open files under the u disk and sd card;
37 -1. The data record configuration data type is a string, the length is two characters, and it will be recorded more than two characters when data is collected record.
38 -1. The data type of the word switch is BCD code, and the increase and decrease do not follow the rule of the BCD code.
39 -1. "Database Format Mismatch" error after Lua script modifies table header.
40 -1. PI3070ig printing part text box printing font is not clear.
41 -1. In the offline simulation state, the graphics position offset occurs in the project with 1920*1080 resolution when the graphics are drawn by the address control.
42 -1. drawing when the graphics position offset.
43 -1. Receiving Data in Lua User Free Protocol 485 _ 2.
44 -1. Lua initialization uses the we_bas_jump screen function to jump to the screen is invalid, and there is a black screen.
45 -1. The data record cannot be recorded when the data record group id is 0.
46 -1. Value input objects check the display natural decimal function is invalid.
47 -1. To enable address control state text, must set the state sequence number, text content, and trigger settings.
48 -1. MQTT is published periodically, and changing the value of the address will also publish.
49 -1. The text on picture has a probability of becoming blurry.
50 -1. When the reset switch triggers hiding, it cannot automatically reset.
51 -1. Alarm records and data records are exported to CSV, and the table header does not switch with language switching.
52 -1. The screen alarm record csv exported using DbToCsvFile has no alarm content.
53 -1. The group number displayed in the recipe Group number address does not match the ID of the recipe display objects.
54 -1. When the number of recipe groups is set to 0, the file name address of the index does not change when there are multiple recipe files.
55 -1. The gallery is too large, causing crash.
56 -1. Drop down list username can't show multilingual.
57 -1. V-NET server anomaly causes device disconnection.
58 -1. The HMI goes off-line due to abnormal dialing of the 4G module.
59 -1. Recipe selected line ID does not match the ID in the address.
60 -1. The USB download project time is not updated, and the local time is not synchronized with the computer time.
61 -1. The keyboard screen cannot be closed normally through we_bas_closescreen function.
62 -1. The IE series uses calibri fonts and the screen display is in Song style.
63 -1. After setting floating setting as big-endian,the recipe table is displayed in Little-endian.
64 -1. Long press the bit switch, and then release the bit switch after entering the static screen saver , and the bit switch cannot be reset.
65 -1. **After the function switch uses object password, the password is invalid after the screen jumps.**
66 -1. **Some IoT cards cannot access the Internet even if they set APN.**
67 -1. Fix other problems.
68 -
69 -Drive
70 -
71 -1. DELTA AS300 MODBUS TCP driver operation D.b bit address invalid.
72 -1. OMRONE5CC driver communication abnormal.
73 -1. Xunpu printer driver prints pictures abnormally.
74 -1. Rockwell Ethernet/IP (CompactLogix Series) driver communication exception.
75 -1. Siemens LOGO drive on-line simulation crash.
76 -1. Fix other problems.
77 -
78 -**New functions**
79 -
80 -Driver
81 -
82 -1. LS MASTER Protocol driver supports bit address selection of D register.
83 -1. **TECO MP300 MODBUS TCP protocol.**
84 -1. **TECO MP300 MODBUS RTU protocol.**
85 -
86 -New models
87 -
88 -1. IN Series: IN1101
89 -1. MD Series: MD8151
90 -1. **ig Series: 3041ig, 8151ig**
91 -
92 -**Precautions**
93 -
94 -Drive 
95 -
96 -**✎Note: WECON LX6V FreeTag Ethernet will not be maintained in the future, please switch to WECON LX6V EtherNet/IP.**
97 -
98 -**✎Note: WECON LX6V FreeTag Series will not be maintained in the future, please switch to Ethernet WECON LX6V EtherNet/IP**
99 -
100 100  == V8.4.66_D23102001 ==
101 101  
102 102  * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.66.23102001.zip]]
... ... @@ -418,7 +418,7 @@
418 418  
419 419  **New functions**
420 420  
421 -PC Software
324 +**PC Software**
422 422  
423 423  1. Data record db file merge function of DataLogTool (Only HMI V2.0 system supports);
424 424  1. (((
... ... @@ -508,69 +508,6 @@
508 508  **INSeries (IN1071, IN1072, IN1073) does not distinguish models and supports mutual projects regardless of models;**
509 509  )))
510 510  
511 -Driver protocol
512 -
513 -1. WECON LX6V EtherNet / IP (Tag protocol optimized version) (Only HMI V2.0 system supports);
514 -1. Rockwell EtherNet / IP (Tag protocol optimized version) (Only HMI V2.0 system supports);
515 -1. OMRON EtherNet/IP (NX/NJ Series) (Tag protocol optimized version) (Only HMI V2.0 system supports);
516 -1. MODBUS RTU Slave (All Fuction OneBaseAddress) can customize broadcast address;
517 -1. SMS module can delete all information;
518 -1. INOVANCE H5U_Easy PLC driver protocol (Serial port);
519 -1. INOVANCE H5U_Easy free tag protocol drive;
520 -1. Xinjie XD/XE drive;
521 -1. Veichi V3 drive;
522 -1. Shihlin SX6V EtherNet/IP Protocol;
523 -1. CODESYS V3 drive;
524 -1. Modbus_Server_IoT_Plat drive;
525 -1. (((
526 -MIT Q00H CPU Port PROTOCOL drive;
527 -)))
528 -1. (((
529 -Schneider TM221 drive;
530 -)))
531 -1. (((
532 -Delta_DVP_ModbusRTU drive;
533 -)))
534 -1. (((
535 -INOVANCE H5U_Easy ModbusTCP drive;
536 -)))
537 -1. (((
538 -Siemens S7-xxx Ethernet OP new drive;
539 -)))
540 -1. (((
541 -MODBUS RTU Slave (All Function) protocol retry timeout time factor multiple ToMu;
542 -)))
543 -1. (((
544 -Schneider TM221 drive;
545 -)))
546 -
547 -{{info}}
548 -**✎Note: The maximum communication number of free tag protocol and CODESYS V3 configuration in models of each series is shown in the following table.**
549 -{{/info}}
550 -
551 -|**Series model**|**Recommended maximum number of free tag protocols**|**Recommended maximum number of CODESYS V3 protocols**
552 -|8000 Series|4|Configuration is not supported.
553 -|3000 Series|Configuration is not supported.|Configuration is not supported.
554 -|9000 Series|Configuration is not supported.|Configuration is not supported.
555 -|3000i Series|Configuration is not supported.|Configuration is not supported.
556 -|ie Series (3043ies with network port)|2|Configuration is not supported.
557 -|ie Series (Other models)|Configuration is not supported.|Configuration is not supported.
558 -|3000ig Series|4|2
559 -|8000ig Series|6|2
560 -|MD3000 Series|4|Configuration is not supported.
561 -|IN Series|Configuration is not supported.|Configuration is not supported.
562 -
563 -(% class="wikigeneratedid" %)
564 -**New models**
565 -
566 -(1). ie Series: 3070ie-H;
567 -
568 -(2). IN Series: IN1071, IN1072, IN1073;
569 -
570 -(3). MD Series: MD3102;
571 -
572 -(4). ig Series: 3070ig-H, 3043ig, 8070ig, 8102ig, 8043ig;
573 -
574 574  == V8.2.95_D20220928 ==
575 575  
576 576  * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220928.zip]]
... ... @@ -925,9 +925,9 @@
925 925  
926 926  = **2 Levi2PI** =
927 927  
928 -== V4.6.2 ==
768 +== V4.5.8 ==
929 929  
930 -* [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Levi2PI%20v4.6.2.zip]]
770 +* [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Levi2PI.zip]]
931 931  
932 932  = **3 HMI Monitor System** =
933 933  
1717728415376-899.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.2454238480
Size
... ... @@ -1,1 +1,0 @@
1 -56.5 KB
Content