Changes for page 3 Software
Last modified by Jett on 2025/03/13 14:13
From version 28.1
edited by Jett
on 2024/06/17 11:45
on 2024/06/17 11:45
Change comment:
There is no comment for this version
To version 21.1
edited by Devin Chen
on 2023/11/15 17:23
on 2023/11/15 17:23
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. 24542384801 +XWiki.DevinChen - Content
-
... ... @@ -1,98 +1,5 @@ 1 1 = **1 PIStudio** = 2 2 3 -== **V8.4.114_D24061301** == 4 - 5 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.114.24061301.zip]] 6 - 7 -**Bugs fixed** 8 - 9 -PC Software 10 - 11 -1. When the MQTT sending mode is set a trigger, entering the trigger address directly cannot save. 12 -1. Arc object property page configuration angle cannot enter 0. 13 -1. Add the 5V protocol first, and then add the printer's protocol, can't change the protocol of the printer. 14 -1. The value of the meter and the color of the scale are inconsistent. 15 -1. After decompile tool open, the software crash. 16 -1. Off-line emulator run time the pictures of function switch object do not display. 17 -1. After deleting multiple screens, the software crash. 18 -1. After copying the local screen successfully, the directly compiled screen objects will be smaller than the modified screen objects. 19 -1. The same project file can be opened by multiple software at the same time. 20 -1. Object id duplication. 21 -1. The bar graph does not use variables, but when compiling, it prompts the variable address error. 22 -1. Using dynamic recipients, email addresses are not compiled and display recipient errors. 23 -1. The objects compile with the address error, but there is no note about what the address error is for which objects. 24 -1. When the circle/ellipse coords are in the negative area, no error message is displayed. 25 -1. When text library imports excel,the blank space and subsequent data cannot be imported. 26 -1. The function screen is deleted and then add it again.it cannot be added. 27 -1. The wrong continuous length when compiling the address of the data record. 28 -1. The wrong continuous length of lua script. 29 -1. PI3041ig configuration Ethernet 2 does not take effect. 30 -1. The wrong coord prompt when the rectangular objects is determined. 31 -1. The data record storage in project setting is error. 32 -1. Fix other problems. 33 - 34 -HMI Application 35 - 36 -1. The function is invalid after the function switch is pressed; 37 -1. The lua function io.open cannot open files under the u disk and sd card; 38 -1. The data record configuration data type is a string, the length is two characters, and it will be recorded more than two characters when data is collected record. 39 -1. The data type of the word switch is BCD code, and the increase and decrease do not follow the rule of the BCD code. 40 -1. "Database Format Mismatch" error after Lua script modifies table header. 41 -1. PI3070ig printing part text box printing font is not clear. 42 -1. In the offline simulation state, the graphics position offset occurs in the project with 1920*1080 resolution when the graphics are drawn by the address control. 43 -1. drawing when the graphics position offset. 44 -1. Receiving Data in Lua User Free Protocol 485 _ 2. 45 -1. Lua initialization uses the we_bas_jump screen function to jump to the screen is invalid, and there is a black screen. 46 -1. The data record cannot be recorded when the data record group id is 0. 47 -1. Value input objects check the display natural decimal function is invalid. 48 -1. To enable address control state text, must set the state sequence number, text content, and trigger settings. 49 -1. MQTT is published periodically, and changing the value of the address will also publish. 50 -1. The text on picture has a probability of becoming blurry. 51 -1. When the reset switch triggers hiding, it cannot automatically reset. 52 -1. Alarm records and data records are exported to CSV, and the table header does not switch with language switching. 53 -1. The screen alarm record csv exported using DbToCsvFile has no alarm content. 54 -1. The group number displayed in the recipe Group number address does not match the ID of the recipe display objects. 55 -1. When the number of recipe groups is set to 0, the file name address of the index does not change when there are multiple recipe files. 56 -1. The gallery is too large, causing crash. 57 -1. Drop down list username can't show multilingual. 58 -1. V-NET server anomaly causes device disconnection. 59 -1. The HMI goes off-line due to abnormal dialing of the 4G module. 60 -1. Recipe selected line ID does not match the ID in the address. 61 -1. The USB download project time is not updated, and the local time is not synchronized with the computer time. 62 -1. The keyboard screen cannot be closed normally through we_bas_closescreen function. 63 -1. The IE series uses calibri fonts and the screen display is in Song style. 64 -1. After setting floating setting as big-endian,the recipe table is displayed in Little-endian. 65 -1. Long press the bit switch, and then release the bit switch after entering the static screen saver , and the bit switch cannot be reset. 66 -1. After the function switch uses object password, the password is invalid after the screen jumps. 67 -1. PI8150ig makes the font size smaller when using calibri font. 68 -1. IN series long press upper left corner, upper right corner invalid. 69 -1. Fix other problems. 70 - 71 -Drive 72 - 73 -1. DELTA AS300 MODBUS TCP driver operation D.b bit address invalid. 74 -1. OMRONE5CC driver communication abnormal. 75 -1. Xunpu printer driver prints pictures abnormally. 76 -1. Rockwell Ethernet/IP (CompactLogix Series) driver communication exception. 77 -1. Siemens LOGO drive on-line simulation crash. 78 -1. Fix other problems. 79 - 80 -**New functions** 81 - 82 -Driver 83 - 84 -1. LS MASTER Protocol driver supports bit address selection of D register. 85 -1. TECO MP300 MODBUS TCP protocol. 86 -1. TECO MP300 MODBUS RTU protocol. 87 - 88 -**Precautions** 89 - 90 -Drive 91 - 92 -✎Note: WECON LX6V FreeTag Ethernet will not be maintained in the future, please switch to WECON LX6V EtherNet/IP. 93 - 94 -✎Note: WECON LX6V FreeTag Series will not be maintained in the future, please switch to Ethernet WECON LX6V EtherNet/IP 95 - 96 96 == V8.4.66_D23102001 == 97 97 98 98 * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.66.23102001.zip]]
- 1717728415376-899.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.2454238480 - Size
-
... ... @@ -1,1 +1,0 @@ 1 -56.5 KB - Content