1 1  = **1 PIStudio** =
2 2  
3 -== **V8.4.114_D24061301** ==
4 -
5 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.114.24061301.zip]]
6 -
7 -**Bugs fixed**
8 -
9 -PC Software
10 -
11 -1. When the MQTT sending mode is set a trigger, entering the trigger address directly cannot save.
12 -1. Arc object property page configuration angle cannot enter 0.
13 -1. Add the 5V protocol first, and then add the printer's protocol, can't change the protocol of the printer.
14 -1. The value of the meter and the color of the scale are inconsistent.
15 -1. After decompile tool open, the software crash.
16 -1. Off-line emulator run time the pictures of function switch object do not display.
17 -1. After deleting multiple screens, the software crash.
18 -1. After copying the local screen successfully, the directly compiled screen objects will be smaller than the modified screen objects.
19 -1. The same project file can be opened by multiple software at the same time.
20 -1. Object id duplication.
21 -1. The bar graph does not use variables, but when compiling, it prompts the variable address error.
22 -1. Using dynamic recipients, email addresses are not compiled and display recipient errors.
23 -1. The objects compile with the address error, but there is no note about what the address error is for which objects.
24 -1. When the circle/ellipse coords are in the negative area, no error message is displayed.
25 -1. When text library imports excel,the blank space and subsequent data cannot be imported.
26 -1. The function screen is deleted and then add it again.it cannot be added.
27 -1. The wrong continuous length when compiling the address of the data record.
28 -1. The wrong continuous length of lua script.
29 -1. PI3041ig configuration Ethernet 2 does not take effect.
30 -1. The wrong coord prompt when the rectangular objects is determined.
31 -1. The data record storage in project setting is error.
32 -1. Fix other problems.
33 -
34 -HMI Application
35 -
36 -1. The function is invalid after the function switch is pressed;
37 -1. The lua function io.open cannot open files under the u disk and sd card;
38 -1. The data record configuration data type is a string, the length is two characters, and it will be recorded more than two characters when data is collected record.
39 -1. The data type of the word switch is BCD code, and the increase and decrease do not follow the rule of the BCD code.
40 -1. "Database Format Mismatch" error after Lua script modifies table header.
41 -1. PI3070ig printing part text box printing font is not clear.
42 -1. In the offline simulation state, the graphics position offset occurs in the project with 1920*1080 resolution when the graphics are drawn by the address control.
43 -1. drawing when the graphics position offset.
44 -1. Receiving Data in Lua User Free Protocol 485 _ 2.
45 -1. Lua initialization uses the we_bas_jump screen function to jump to the screen is invalid, and there is a black screen.
46 -1. The data record cannot be recorded when the data record group id is 0.
47 -1. Value input objects check the display natural decimal function is invalid.
48 -1. To enable address control state text, must set the state sequence number, text content, and trigger settings.
49 -1. MQTT is published periodically, and changing the value of the address will also publish.
50 -1. The text on picture has a probability of becoming blurry.
51 -1. When the reset switch triggers hiding, it cannot automatically reset.
52 -1. Alarm records and data records are exported to CSV, and the table header does not switch with language switching.
53 -1. The screen alarm record csv exported using DbToCsvFile has no alarm content.
54 -1. The group number displayed in the recipe Group number address does not match the ID of the recipe display objects.
55 -1. When the number of recipe groups is set to 0, the file name address of the index does not change when there are multiple recipe files.
56 -1. The gallery is too large, causing crash.
57 -1. Drop down list username can't show multilingual.
58 -1. V-NET server anomaly causes device disconnection.
59 -1. The HMI goes off-line due to abnormal dialing of the 4G module.
60 -1. Recipe selected line ID does not match the ID in the address.
61 -1. The USB download project time is not updated, and the local time is not synchronized with the computer time.
62 -1. The keyboard screen cannot be closed normally through we_bas_closescreen function.
63 -1. The IE series uses calibri fonts and the screen display is in Song style.
64 -1. After setting floating setting as big-endian,the recipe table is displayed in Little-endian.
65 -1. Long press the bit switch, and then release the bit switch after entering the static screen saver , and the bit switch cannot be reset.
66 -1. After the function switch uses object password, the password is invalid after the screen jumps.
67 -1. PI8150ig makes the font size smaller when using calibri font.
68 -1. IN series long press upper left corner, upper right corner invalid.
69 -1. Fix other problems.
70 -
71 -Drive
72 -
73 -1. DELTA AS300 MODBUS TCP driver operation D.b bit address invalid.
74 -1. OMRONE5CC driver communication abnormal.
75 -1. Xunpu printer driver prints pictures abnormally.
76 -1. Rockwell Ethernet/IP (CompactLogix Series) driver communication exception.
77 -1. Siemens LOGO drive on-line simulation crash.
78 -1. Fix other problems.
79 -
80 -**New functions**
81 -
82 -Driver
83 -
84 -1. LS MASTER Protocol driver supports bit address selection of D register.
85 -1. TECO MP300 MODBUS TCP protocol.
86 -1. TECO MP300 MODBUS RTU protocol.
87 -
88 -**Precautions**
89 -
90 -Drive 
91 -
92 -✎Note: WECON LX6V FreeTag Ethernet will not be maintained in the future, please switch to WECON LX6V EtherNet/IP.
93 -
94 -✎Note: WECON LX6V FreeTag Series will not be maintained in the future, please switch to Ethernet WECON LX6V EtherNet/IP
95 -
96 96  == V8.4.66_D23102001 ==
97 97  
98 98  * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.66.23102001.zip]]