Changes for page 3 Software

Last modified by Jett on 2025/03/13 14:13

From version 29.1
edited by Jett
on 2025/01/06 10:14
Change comment: There is no comment for this version
To version 33.1
edited by Mora Zhou
on 2025/01/06 11:07
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.2454238480
1 +XWiki.Mora
Content
... ... @@ -4,6 +4,98 @@
4 4  
5 5  * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.1.18.24122702.zip]]
6 6  
7 +**Bugs fixed**
8 +
9 +1. RE series V-BOX PLC Pass-through sometime can't work properly.
10 +1. RE series V-BOX data record upload can't work properly.
11 +1. PI8043ig and PI3041ig recipe object unable to display properly in web side.
12 +1. When entering the backstage for the first time after the screen is restarted, the first digit of the backstage password is invalid.
13 +1. PI8043ig project file is too large to the logo is stuck when HMI restarted.
14 +1. WIFI model can not enable after update the system.
15 +1. HMI crash and freeze when downloading PLC project.
16 +1. When the rectangle/arc/circle object is first initialized, a shadow will appears.
17 +1. The cloud icon in backstage state error.
18 +1. In off-line simulation.The left lable of Numeric Input/Display object affect natural decimal display.
19 +1. MQTT tool publish bit address,the length setting is not 1,message error.
20 +1. MQTT V5 protocol cannot automatically connect after network disconnection.
21 +1. The cloud management tool cannot log in to non-administrator users normally.
22 +1. Object lock does not work for bit switch momentary mode.
23 +1. WIFI is not connected, but IP still exists.
24 +1. The actual minimum pressing time of the function switch does not match the setting.
25 +1. RH-WF V-BOX indicator lamp display error.
26 +1. Data record display object start time setting error.
27 +1. The camera display object disappear after switching screens.
28 +1. After using the four arithmetic operations in address mapping, reading the value in read-only mode displays an abnormality.
29 +1. Object level password does not match the setting.
30 +1. In offline simulation, the new recipe tool crashes by clicking keyboard letters.
31 +1. Recipe name changes when switching screens.
32 +1. PLC program upload fails when PLC Pass-Through.
33 +1. IDEC MicroSmart Protocol:TC CC register modifying the value of the address results in an error in the value of the next address.
34 +1. Delta_AS300_TCP Protocol:D.b register cannot modify status.
35 +1. OPCUA Client:communication error but have no time-out message.
36 +1. IEC104client:HMI get black screen after downloading this protocol.
37 +
38 +**New functions**
39 +
40 +PC Software
41 +
42 +1. New project properties page.
43 +1. i/ie/ig/IN/RE/RH series all support screen style.
44 +1. Download tool support RE,RH series flash light and test network.
45 +1. New Device management tool.
46 +1. Software homepage embedded Wecon support center.
47 +1. Allow configuration preserve network configuration when download the project.
48 +1. Software online update.
49 +1. Scada canvas extension, new draft area.
50 +1. Recipe element support bit address.
51 +1. OPC UA server.
52 +1. New X,Y internal registers(RH series).
53 +1. 3000ig series Limitation of the Ethernet communication protocol up to 32.
54 +
55 +HMI Application
56 +
57 +1. New recipe object-Recipe Record:Integrated search, add, delete, download, upload, import, export, and switch recipe functions.
58 +1. New backstage:The background can be exited instead of restarted,New UI,Ethernet download PLC program,USB update support update the system and project at the same time.
59 +1. Remote backstage.
60 +1. New system keyboard.
61 +1. Character Input/Display object support multi line display.
62 +1. Character Input/Display object support choose data format(UTF-8/GBK/UNICODE).
63 +1. Numeric Input/Display object support more 64bit data format.
64 +1. Modification of serial port parameters takes effect immediately.
65 +1. RE series can be bound to V-NET.
66 +1. lua script open user permission function interface.
67 +1. New Multi-link function.
68 +1. New special registers related to automatic logout of user functionse.
69 +1. Alarm info support multiple variables.
70 +1. Min.hold time countdown.
71 +1. ig-O support Wecon 6V freetags protocol and CODESYS V3 protocol.
72 +1. (((
73 +New special registers related to displaying user storage space information.
74 +)))
75 +
76 +Driver protocol
77 +
78 +1. OPCUA Client.
79 +1. Siemens S7-1200/1500 Ethernet FreeTag.
80 +1. TwinCAT PLC Ethernet.
81 +1. KEYENCE KV-5000(Ethernet) using bit address in word address.
82 +
83 +**New model**
84 +
85 +1. RE series:RE-00,RE-00-LA,RE-4G,RE-4G-LA
86 +1. RH series:RH-WIFI
87 +1. ig series:PI3101ig,PI8101ig,PI8121ig
88 +
89 +(% class="box infomessage" %)
90 +(((
91 +**Notice**
92 +
93 +1. The new version can not support general series(PI3000,PI8000,PI9000). Please use the old version (Release Build VER:R05R998_V8.4.114_D24061301) to program the general series.
94 +1. Projects opened with the new version cannot be opened with the old version. Please make sure to back up the project.
95 +1. After the upgrade, the supported protocols will change. **For details, please refer to: [[Limitation of the Ethernet communication protocol - Wecon>>url:https://docs.we-con.com.cn/bin/view/PIStudio/PLC Protocol/Limitation of the Ethernet communication protocol/]]**
96 +1. Cannot roll back the version after upgrading.
97 +)))
98 +
7 7  == **V8.4.114_D24061301** ==
8 8  
9 9  * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.114.24061301.zip]]