Changes for page 3 Software

Last modified by Jett on 2025/06/27 09:22

From version 29.1
edited by Jett
on 2025/01/06 10:14
Change comment: There is no comment for this version
To version 49.1
edited by Jett
on 2025/06/27 09:22
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,9 +1,184 @@
1 1  = **1 PIStudio** =
2 2  
3 +
4 +== **V9.4.13.25053001** ==
5 +
6 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.4.13.25053001.zip]]
7 +
8 +(% class="box errormessage" %)
9 +(((
10 +**Notice**
11 +
12 +1. The new version can not support general series(PI3000,PI8000,PI9000). Please use the old version (Release Build VER:R05R998_V8.4.114_D24061301) to program the general series.
13 +1. **After the upgrade, only the ig series can use the Lua MQTT library.**
14 +1. Projects opened with the new version cannot be opened with the old version. Please make sure to back up the project.
15 +1. After the upgrade, the supported protocols will change. PI3000ig can not support the third-part Free-tags Protocol.**For details, please refer to: [[Limitation of the Ethernet communication protocol - Wecon>>url:https://docs.we-con.com.cn/bin/view/PIStudio/PLC Protocol/Limitation of the Ethernet communication protocol/]]**
16 +1. Cannot roll back the version after upgrading.
17 +)))
18 +
19 +**Bugs fixed**
20 +
21 +1. The centralized monitoring page (Device management tool) of WIN7 system using 9.3 software displays blank
22 +1. Ethernet setting and 4G setting can not close in the backstage.
23 +1. 3000ig, 8000ig, and RE series update interruption during project download causes Ethernet connection error
24 +1. After setting the calculation and length when mapping the bit address, the mapping error occurs
25 +1. ie series HSW10494 can not display the machine code.
26 +1. After clearing the alarm record, the subsequent record exports are all blank.
27 +1. HMI freeze when alarm record display object choose head text color and color of alarm text at the same time.
28 +1. USB download error when 3070ig-C in the loading page.
29 +1. Optimized the display font and format of the background of some models
30 +1. 3035ie Time reset problem that may occur when downloading a project
31 +1. Administrator privileges can be removed directly
32 +1. HMI screen cannot be awakened by mouse after being turned off
33 +1. ie series HDW register range becomes invalid when it exceeds  HDW100,000
34 +1. Optimize SIEMENS S7-1200 Ethernet new protocol
35 +
36 +**New functions**
37 +
38 +1. Added special register HSW11816 to control the button size of the new recipe tool
39 +
40 +**New drive**
41 +
42 +1. JUNCAUTO Jxxx Series protocol
43 +
44 +== **V9.3.2.25030401** ==
45 +
46 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.3.2.25030401.zip]]
47 +
48 +(% class="box errormessage" %)
49 +(((
50 +**Notice**
51 +
52 +1. The new version can not support general series(PI3000,PI8000,PI9000). Please use the old version (Release Build VER:R05R998_V8.4.114_D24061301) to program the general series.
53 +1. **After the upgrade, only the ig series can use the Lua MQTT library.**
54 +1. Projects opened with the new version cannot be opened with the old version. Please make sure to back up the project.
55 +1. After the upgrade, the supported protocols will change. PI3000ig can not support the third-part Free-tags Protocol.**For details, please refer to: [[Limitation of the Ethernet communication protocol - Wecon>>url:https://docs.we-con.com.cn/bin/view/PIStudio/PLC Protocol/Limitation of the Ethernet communication protocol/]]**
56 +1. Cannot roll back the version after upgrading.
57 +)))
58 +
59 +**Bugs fixed**
60 +
61 +1. Rectangle object disappear when using color control function.
62 +1. ie series can not use the Indirect addressing function.
63 +1. gif images are stuck when used.
64 +1. APN cannot be saved correctly in 4G Setting.
65 +1. About time span of the alarm record display,the value in LAN monitoring does not match the actual value.
66 +1. The new recipe tool displays anomalies in LAN Monitoring
67 +1. Recipe data cannot be saved when downloading the project via USB
68 +1. Communication problem between ie series and 5V PLC.
69 +1. Communication error with Omron PLC after RE/RH series restart.
70 +1. The string display error for the Siemens S7-1200 protocol.
71 +1. Mobile data consumption is abnormal when HMI is connected to the cloud via 4G.
72 +1. Fix other bug.
73 +1. Optimized shape gallery content.
74 +1. Optimized some of communication protocols.
75 +
76 +**New functions**
77 +
78 +1. The drop-down list triggers the beeper function
79 +1. Add watchdog function.
80 +
81 +**New model**
82 +
83 +1. PI8102ig-H
84 +
3 3  == **V9.1.18.24122702** ==
4 4  
5 5  * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.1.18.24122702.zip]]
6 6  
89 +(% class="box errormessage" %)
90 +(((
91 +**Notice**
92 +
93 +1. The new version can not support general series(PI3000,PI8000,PI9000). Please use the old version (Release Build VER:R05R998_V8.4.114_D24061301) to program the general series.
94 +1. **After the upgrade, only the ig series can use the Lua MQTT library.**
95 +1. Projects opened with the new version cannot be opened with the old version. Please make sure to back up the project.
96 +1. After the upgrade, the supported protocols will change. PI3000ig can not support the third-part Free-tags Protocol.**For details, please refer to: [[Limitation of the Ethernet communication protocol - Wecon>>url:https://docs.we-con.com.cn/bin/view/PIStudio/PLC Protocol/Limitation of the Ethernet communication protocol/]]**
97 +1. Cannot roll back the version after upgrading.
98 +)))
99 +
100 +**Bugs fixed**
101 +
102 +1. RE series V-BOX PLC Pass-through sometime can't work properly.
103 +1. RE series V-BOX data record upload can't work properly.
104 +1. PI8043ig and PI3041ig recipe object unable to display properly in web side.
105 +1. When entering the backstage for the first time after the screen is restarted, the first digit of the backstage password is invalid.
106 +1. PI8043ig project file is too large to the logo is stuck when HMI restarted.
107 +1. WIFI model can not enable after update the system.
108 +1. HMI crash and freeze when downloading PLC project.
109 +1. When the rectangle/arc/circle object is first initialized, a shadow will appears.
110 +1. The cloud icon in backstage state error.
111 +1. In off-line simulation.The left lable of Numeric Input/Display object affect natural decimal display.
112 +1. MQTT tool publish bit address,the length setting is not 1,message error.
113 +1. MQTT V5 protocol cannot automatically connect after network disconnection.
114 +1. The cloud management tool cannot log in to non-administrator users normally.
115 +1. Object lock does not work for bit switch momentary mode.
116 +1. WIFI is not connected, but IP still exists.
117 +1. The actual minimum pressing time of the function switch does not match the setting.
118 +1. RH-WF V-BOX indicator lamp display error.
119 +1. Data record display object start time setting error.
120 +1. The camera display object disappear after switching screens.
121 +1. After using the four arithmetic operations in address mapping, reading the value in read-only mode displays an abnormality.
122 +1. Object level password does not match the setting.
123 +1. In offline simulation, the new recipe tool crashes by clicking keyboard letters.
124 +1. Recipe name changes when switching screens.
125 +1. PLC program upload fails when PLC Pass-Through.
126 +1. IDEC MicroSmart Protocol:TC CC register modifying the value of the address results in an error in the value of the next address.
127 +1. Delta_AS300_TCP Protocol:D.b register cannot modify status.
128 +1. OPCUA Client:communication error but have no time-out message.
129 +1. IEC104client:HMI get black screen after downloading this protocol.
130 +
131 +**New functions**
132 +
133 +PC Software
134 +
135 +1. New project properties page.
136 +1. i/ie/ig/IN/RE/RH series all support screen style.
137 +1. Download tool support RE,RH series flash light and test network.
138 +1. New Device management tool.
139 +1. Software homepage embedded Wecon support center.
140 +1. Allow configuration preserve network configuration when download the project.
141 +1. Software online update.
142 +1. Scada canvas extension, new draft area.
143 +1. Recipe element support bit address.
144 +1. OPC UA server.
145 +1. New X,Y internal registers(RH series).
146 +1. 3000ig series Limitation of the Ethernet communication protocol up to 32.
147 +
148 +HMI Application
149 +
150 +1. New recipe object-Recipe Record:Integrated search, add, delete, download, upload, import, export, and switch recipe functions.
151 +1. New backstage:The background can be exited instead of restarted,New UI,Ethernet download PLC program,USB update support update the system and project at the same time.
152 +1. Remote backstage.
153 +1. New system keyboard.
154 +1. Character Input/Display object support multi line display.
155 +1. Character Input/Display object support choose data format(UTF-8/GBK/UNICODE).
156 +1. Numeric Input/Display object support more 64bit data format.
157 +1. Modification of serial port parameters takes effect immediately.
158 +1. RE series can be bound to V-NET.
159 +1. lua script open user permission function interface.
160 +1. New Multi-link function.
161 +1. New special registers related to automatic logout of user functionse.
162 +1. Alarm info support multiple variables.
163 +1. Min.hold time countdown.
164 +1. ig-O support Wecon 6V freetags protocol and CODESYS V3 protocol.
165 +1. (((
166 +New special registers related to displaying user storage space information.
167 +)))
168 +
169 +Driver protocol
170 +
171 +1. OPCUA Client.
172 +1. Siemens S7-1200/1500 Ethernet FreeTag.
173 +1. TwinCAT PLC Ethernet.
174 +1. KEYENCE KV-5000(Ethernet) using bit address in word address.
175 +
176 +**New model**
177 +
178 +1. RE series:RE-00,RE-00-LA,RE-4G,RE-4G-LA
179 +1. RH series:RH-WIFI
180 +1. ig series:PI3101ig,PI8101ig,PI8121ig
181 +
7 7  == **V8.4.114_D24061301** ==
8 8  
9 9  * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.114.24061301.zip]]
... ... @@ -935,6 +935,7 @@
935 935  
936 936  * Google Drive: [[Download Link>>https://drive.google.com/file/d/1RA3ui3jTCKtQTCLySjD4Qi7Ut58EYYD1/view?usp=sharing]]
937 937  
938 -= **4 Logo Making Tool** =
1113 += **4 StartupLogoTool** =
939 939  
940 -* Google Drive: [[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]
1115 +* V3.0.19: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/StartupLogoTool%20V3.0.19.zip]]
1116 +* old version: [[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]