Changes for page 3 Software

Last modified by Joe on 2026/03/27 09:17

From version 3.1
edited by Joe
on 2025/09/05 15:11
Change comment: There is no comment for this version
To version 11.1
edited by Joe
on 2026/03/27 09:17
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,6 +1,212 @@
1 +(((
1 1  = **1 PIStudio** =
3 +)))
2 2  
5 +(((
6 +== **V10.5.45.25102301(New modules: PI9000ig, RL, RH, WP)** ==
7 +)))
3 3  
9 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_10.5.zip]]
10 +
11 +(% class="wikigeneratedid" %)
12 +**Bugs fixed**
13 +
14 +1. Slow response issue with IN series HMI;
15 +1. Slow response of alarm record and address monitoring table, and stuck when opening the project;
16 +1. LREAL data type cannot be read and written;
17 +1. The overlapping screen cannot be set when the sub-screen is selected in screen;
18 +1. The encoding method options for string type data in Data record;
19 +1. Communication failure on Ethernet2 of HMI when using IP address from different Subnets for Ethernet1 and Ethernet2.
20 +1. The addresses of X and Y are inconsistent in XY trend chart,;
21 +1. Object lock cannot be an index address;
22 +1. Lagging display of camera;
23 +1. Stuck on logo issue during IN, IE series upgrade;
24 +1. The IN series HMI do not support the mouse style configuration;
25 +1. Failure to download projects to IN series HMI ;
26 +1. PDF prompts display abnormal;
27 +1. CAN port configuration communication error;
28 +1. When RH device uses 4K resolution, the fonts of message prompt, background, etc. are too small;
29 +1. The issue of translator multi-language;
30 +1. Invalid address mapping;
31 +1. The advanced configuration effect of device search, device management and cloud management download project not match the expected results;
32 +1. RH-00 communication configuration does not have ETH2 configuration;
33 +1. The ig model system keyboard is not working;
34 +1. The ig, RH series vertical screen mouse movement and touch optimized;
35 +1. 4.3-inch HMI vertical screen background display effect;
36 +1. Issue of Siemens S7-1200 DBS register reads and writes less than half, need to check the ”Read DWord” option;
37 +1. OPC UA Client reads and writes strings issue, if the new string is shorter than the old one, the end of the old string will be remained;
38 +1. If using too many element in recipe for JUNCAUTO protocol, the address will be clean and overwrite the data in low addresses;
39 +1. Write LX5V bit-in-word;
40 +1. OPC UA Client cannot connect to the server configured with authentication;
41 +1. OPC UA Client cannot reconnect normally after unplugging/plugging the network cable;
42 +1. Changing communication methods in the background is invalid;
43 +1. Set user permissions on the screen, but the register cannot jump to this screen;
44 +1. The issue of abnormal using indirect screen on sub-screen;
45 +1. Abnormal display of the bar graph ;
46 +1. The RH series cannot use the CODESYS protocol;
47 +1. When the simulator's print object is set to screenshot mode, the screen cannot be switched after a screenshot.
48 +1. Operation records do not support text variable insert;
49 +1. Object or font shrinking when moving numeric object;
50 +1. CODESYS V3 protocol cannot read the Unicode string of LX6C (WSTRING);
51 +1. The issue with the UNION type data in Omron;
52 +1. Communication failure after the end of VPN pass-through, ;
53 +1. Communication failure between Keyence KV series protocol and 9000ig series;
54 +1. Gallery size limitation per screen for IN, IE and RH series;
55 +1. Other issues;
56 +
57 +(% class="wikigeneratedid" %)
58 +**New functions**
59 +
60 +(% class="wikigeneratedid" %)
61 +PC Software
62 +
63 +1. Software style selection;
64 +1. Screen layer;
65 +1. Template screen;
66 +1. Project tree objects list;
67 +1. Software settings page;
68 +1. The color palette adds a color picker;
69 +1. Address priority configuration;
70 +1. German is added to the software language;
71 +1. Automatic project backup;
72 +1. Address list search replacement;
73 +1. Import and export of user login information;
74 +1. The toolbar adds an upload project entrance and a toolbox entrance;
75 +1. UI enhancement;
76 +1. Software toolbar layout optimized;
77 +1. Address compilation optimized;
78 +1. Address integration optimized;
79 +1. Project multi-language translation(Only Baidu API key);
80 +1. Sound library configuration;
81 +1. BACNet server;
82 +1. Address search and replace;
83 +1. String table text alignment;
84 +1. Support for string table configuration
85 +1*. Drop-down list;
86 +1*. Data Record (channel name);
87 +1*. Recipe(element name);
88 +1*. Bit alarm text;
89 +1*. Word alarm text;
90 +1. Object copy attributes (font/size/color) to other languages;
91 +1. Project format upgrade.(.pi to .pi2)
92 +1. After the communication port connection is deleted, the communication port number is automatically sorted;
93 +1. Sub-screen pops up coordinate configuration;
94 +1. Alarm address communication priority (import/export);
95 +1. Text tag function;
96 +1. Text position vertical adjustment;
97 +1. Beckhoff tag import filtering;
98 +1. Schedule ;
99 +1. Column Chart object;
100 +1. Improve the success rate of pass-through;
101 +
102 +(% class="wikigeneratedid" %)
103 +HMI Application
104 +
105 +1. NTP time synchronization;
106 +1. New touch calibration interface;
107 +1. Sub screen modal mode;
108 +1. Exclusive operation;
109 +1. Watchdog;
110 +1. New Alarm Record;
111 +1*. New alarm record interface;
112 +1*. Alarm record ascending/descending order;
113 +1*. Alarm record statistics;
114 +1*. Diverse Alarm record styles;
115 +1. Media player;
116 +1. Mouse cursor style;
117 +1. Timeout NC effect;
118 +1. Sub-screen drag-and-drop;
119 +1. Minimum pressing interval time countdown tips UI;
120 +1. Additional options for trigger write addresses in alarm records;
121 +1. UNICODE and GBK display format are added to alarm variables;
122 +1. User permissions can configure the time of auto logout;
123 +1. Text-To-Speech;
124 +1. Voice broadcast;
125 +1. The message prompt module supports 48 languages;
126 +1. Remote management module in the background;
127 +1*. Remote background;
128 +1*. Access verification;
129 +1*. IP Whitelist/Blacklist;
130 +1*. Access log viewing;
131 +1. Configure network routing mode, switch mode and WIFI hotspot in the background
132 +1. RH series, 9000ig series DIP switch function
133 +1*. Factory reset
134 +1*. Touch calibration adaptation;
135 +1. Vertical alignment method for text display;
136 +1. Column Chart;
137 +1. Text tag function;
138 +1. Supports control via special registers to adjust the button size and spacing on the new Alarm record object, new Recipe Record object, and Column Chart;
139 +1. The text for email content, user login (username), user login (description), and log message text (operation records) supports configuration via a string table.
140 +1. Task scheduler;
141 +1. Sub-screen pop-up position optimization;
142 +1. RE and RL series support NTP (network time protocol) function;
143 +
144 +(% class="wikigeneratedid" %)
145 +**New drive**
146 +
147 +1. Winding Machine MODBUS RTU Winder;
148 +1. KEYENCE EtherNet/IP (KV-8000);
149 +1. KEYENCE EtherNet/IP (KV-X310);
150 +1. KEYENCE EtherNet/IP (KV-X520);
151 +1. INOVANCE H5U PLC Ethernet FreeTag (fast) replaces INOVANCE H5U PLC Ethernet FreeTag ;
152 +1. Siemens Ethernet FreeTag (S7 Series);
153 +1. LAICARD RFID Reader;
154 +1. KEYENCE Scanner HR-100B;
155 +1. KEYENCE Scanner HR-100;
156 +1. RONGSHI RFID Reader;
157 +1. KCJ RFID Reader;
158 +1. BACnet_IP;
159 +1. HONEYWELL Scanner 1902-C;
160 +1. Read interval time setting (RwDelay register) for modbus rtu slave.
161 +1. Expanded SD,SM register address range (up to 511) for INVT_IVC1.
162 +1. Leadshine LEISHINE _ SC-C32A4DS ModbusTcp;
163 +1. Leadshine LEISHINE _ SC-C32A4DS ModbusRTU;
164 +1. FANUC protocol;
165 +1. NEWLAND Scanner;
166 +1. NEWLAND Scanner COM;
167 +1. Leadshine LEISHINE _ LC1000 _ Series _ TCP;
168 +1. Leadshine LEISHINE _ LC1000 _ Series _ RTU;
169 +1. ModBus RTU Slave (All Fuction)~-~-RwDelay register for controlling send/receive interval;
170 +1. MITSUBISHI FX5U Ethernet—Bit-in-Word;
171 +1. Expanded SD, SM register range for INVT_IVC1 protocol;
172 +1. New CODESYS V3 protocol-read Unicode strings (WSTRING data type);
173 +
174 +(% class="wikigeneratedid" %)
175 +**New models**
176 +
177 +1. GB series: GB3041, GB3070, GB3101, GB8041, GB8070-H, GB8101;
178 +1. ig series: PI9102ig, PI9121ig, PI9150ig, PI9151ig;
179 +1. WP series: WP2070, WP2071, WP3070, WP3071;
180 +1. MD series: MD8102;
181 +1. RL series: RL-G, RL-WF;
182 +1. RH series: RH-00, RH-00-4K, RH-AG, RH-G, RH-W, RH-WG, RH-WG-CNC, RH-WG-E, RH-WG-LA, RH-WIFI;
183 +
184 +== **V9.5.9.25091702** ==
185 +
186 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.5.9.25091702.zip]]
187 +
188 +(% class="box errormessage" %)
189 +(((
190 +**Notice**
191 +
192 +1. The new version can not support general series(PI3000,PI8000,PI9000). Please use the old version (Release Build VER:R05R998_V8.4.114_D24061301) to program the general series.
193 +1. **After the upgrade, only the ig series can use the Lua MQTT library.**
194 +1. Projects opened with the new version cannot be opened with the old version. Please make sure to back up the project.
195 +1. After the upgrade, the supported protocols will change. PI3000ig can not support the third-part Free-tags Protocol.**For details, please refer to: [[Limitation of the Ethernet communication protocol - Wecon>>url:https://docs.we-con.com.cn/bin/view/PIStudio/PLC Protocol/Limitation of the Ethernet communication protocol/]]**
196 +1. Cannot roll back the version after upgrading.
197 +)))
198 +
199 +**Bugs fixed**
200 +
201 +1. i Series 485_2 communication issues;
202 +1. Pie chart control lag issues under certain circumstances;
203 +1. Remote monitoring issues with the mobile app and PC client software causing link errors;
204 +1. Other issues;
205 +
206 +**New functions**
207 +
208 +Cloud configuration supports Asian 2.0 servers;
209 +
4 4  == **V9.4.13.25053001** ==
5 5  
6 6  * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.4.13.25053001.zip]]
... ... @@ -748,7 +748,7 @@
748 748  
749 749  == V8.2.95_D20220928 ==
750 750  
751 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220928.zip]]
957 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.2.95.22092802.zip]]
752 752  
753 753  (% class="wikigeneratedid" id="HBugsfixed" %)
754 754  **Bugs fixed**