Changes for page 3 Software

Last modified by Hunter on 2026/10/24 16:44

From version 3.1
edited by Joe
on 2025/09/05 15:11
Change comment: There is no comment for this version
To version 22.1
edited by Hunter
on 2026/10/24 16:36
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.joe
1 +XWiki.Hunter
Content
... ... @@ -1,6 +1,346 @@
1 +(((
1 1  = **1 PIStudio** =
2 2  
4 +== **V10.6.54.26102001** ==
3 3  
6 +* Offcial Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_10.6.54.26102001.zip]]
7 +
8 +**Bugs fixed**
9 +
10 +Bugs Fixed
11 +
12 +1. BACnet protocol communication error;
13 +1. LX6V PLC program download via USB flash drive fails under certain conditions;
14 +1. Media player loading error during multi-language switching;
15 +1. Network service startup error under certain conditions;
16 +1. RH firmware update via USB flash drive fails;
17 +1. Added version verification for communication protocols;
18 +1. Optimized touch calibration for 9121ig;
19 +1. An error occurs when using bit addresses with the CAN protocol;
20 +1. Lag occurs when the address library contains a large number of entries;
21 +1. Siemens S7-1200/1500 Ethernet Expansion communication issues;
22 +1. Incomplete display of remote backend protocol driver version information;
23 +1. Offset display of multi-language static text alignment position in specific situations;
24 +1. "Insufficient space [1002]" error message when downloading the project in specific situations;
25 +1. Upload failure after exceeding the number of incorrect password attempts;
26 +1. Abnormal display size of Alarm Record and Recipe record on the web page monitoring;
27 +1. 4G card not recognized by 4G module;
28 +1. Communication fails of 485_2 for i series;
29 +1. Real-time trend chart data not displayed under specific configurations;
30 +1. Pie chart not update in specific situations;
31 +1. The function switch does not work when Minimum hold time, object level, and activate on release are enabled simultaneously;
32 +1. Email SMTP address field input limitation;
33 +1. Issues with user permission operation logs in old project;
34 +1. Image sizes are saved incorrectly in the picture library for IN series models;
35 +1. Screen content is missing during offline simulation under certain conditions after editing bit alarms, alarm record objects;
36 +1. Vigor WC register type error;
37 +1. MIT iQ-L Series CPU MELSEC PROTOCOL X register type range issue;
38 +
39 +**New models**
40 +
41 +
42 +1. IN Series: IN1071-H;
43 +1. ig Series: 9156ig;
44 +
45 +== **V10.6.45.26070101** ==
46 +
47 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/PIStudio_10.6.45.26070101.zip]]
48 +
49 +**Bugs fixed**
50 +
51 +1. Object -level password check option “Becomes the lowest level”;
52 +1. Static IP inaccessible after VPN pass-through;
53 +1. Multi-language switching not supported when exporting alarm record files;
54 +1. Some fonts displayed offset in remote screens;
55 +1. Indirect screens displayed abnormally in Remote monitoring;
56 +1. Some fonts displayed abnormally;
57 +1. Connecting Easy521 with INOVANCE H5U PLC via Ethernet protocol causes partial register addresses to fail to be read on the screen;
58 +1. RH-WG-LA unable to communicate with LX6C via WiFi;
59 +1. S7-1200 protocol string data issue;
60 +1. After a project is set to read-only mode, other projects cannot be opened afterward;
61 +1. Background function custom parameter display failure;
62 +1. Multi-layer nested indirect screens displayed abnormally;
63 +1. Indirect screens flickered when screen switching;
64 +1. Alarm Runbar failed to display blank spaces for alarms;
65 +1. Freetag communication indicator showed incorrect status;
66 +1. OPC UA client crash caused by repeated connection;
67 +1. Communication failure of SIEMENS AGLink protocol via Ethernet2;
68 +1. The KEYENCE KV-5000 protocol incomplete device address range.
69 +1. AB CompactLogix communication failure;
70 +1. Sub-screens not fully displayed when zoomed in;
71 +1. The popup of the function switch configuration interface shows coordinate position setting error;
72 +1. Inappropriate translation in some configuration screens;
73 +1. Modifying the hidden bit address of a text object will clear the text content;
74 +1. A beep still sounds when clicking after the drop-down list is hidden;
75 +1. Errors occur when a static IP is configured in the background without DNS setup;
76 +1. File list select-all copy-paste operation failed;
77 +1. Some special symbols displayed abnormally in Runbar messages;
78 +1. Meter object digital status failed to display normally;
79 +1. Alarm record display filter cumulative time and occurrence count sorting ineffective;
80 +1. Alarm record row space color setting ineffective;
81 +1. BACnet driver-related issues;
82 +1. H5U Ethernet protocol communication timeout problem;
83 +1. "Not created by this software" when opening projects in specific conditions;
84 +1. Bit alarm import anomaly in specific conditions;
85 +1. When the project has multiple templates, only one can be displayed in specific conditions;
86 +1. Private deployment URL configuration failure in specific conditions;
87 +1. No compilation error occurs after removing an address from the address library;
88 +1. Using the address list replacement function clears VB scripts;
89 +1. OMRON PLC communication timeout;
90 +1. Indirect screens flickered when screen switching;
91 +1. High delay in message prompt popups in specific conditions;
92 +1. Failed to connect to encrypted MQTT servers;
93 +1. MQTT publish error in Lua script;
94 +1. Communication failure between RH-WG-LA and LX6C via Wi-Fi.
95 +1. Communication anomaly in INOVANCE H5U PLC Ethernet protocol in specific conditions;
96 +1. SMS sending error in Lua script;
97 +1. Timeout occurs when continuously writing over 800 addresses to SCHNEIDER M221 PLC via Ethernet;
98 +1. Optimize loading speed of numeric input and text input controls;
99 +1. Optimize layout and style of background interface;
100 +1. Optimize loading speed of background WIFI configuration page;
101 +1. Optimize background prompt messages;
102 +1. Optimize communication efficiency of free tags;
103 +1. New calibration interface;
104 +1. Optimize click response speed of dropdown list;
105 +1. Optimize loading speed of alarm data during device startup;
106 +1. Other issues;
107 +
108 +**New functions**
109 +
110 +**PC software**
111 +
112 +1. Added: MQTT multi-server configuration;
113 +1. Add downloaded project path and update version No. for device management tool title;
114 +1. Europe 2.0 server option
115 +
116 +**HMI application**
117 +
118 +1. Display user storage space in background;
119 +1. Background online upgrade channel;
120 +1. Support European V2.0 server configuration in background;
121 +1. Register HSW2108 sets the scrollbar width of dropdown list;
122 +1. Lua interface for device name configuration;
123 +1. Register HSW893 controls synchronous/asynchronous mode of user permission between web terminal and touch screen terminal;
124 +1. Lua interface for selecting sound card of TTS voice playback;
125 +1. Registers HSW11829 and HSW11830 control keyboard mask transparency;
126 +1. Register HSW11831 controls enable/disable of long-press countdown animation effect;
127 +1. Optimize built-in virtual keyboard to support continuous text input after pressing backspace key;
128 +
129 +**New drive**
130 +
131 +1. KEYENCE KV-7000/8000 (Ethernet);
132 +1. Siemens S7-1200 Ethernet new protocol adds DBxDBLW four-word register;
133 +1. Siemens S7-200 Smart (Ethernet) V3/G2 drive;
134 +1. MIT Q Series CPU MELSEC PROTOCOL;
135 +1. MIT iQ-L Series CPU MELSEC PROTOCOL;
136 +1. MIT iQ-R Series CPU MELSEC PROTOCOL;
137 +)))
138 +
139 +(((
140 +== **V10.5.45.25102301(New available modules: PI9000ig, RL, RH, WP)** ==
141 +)))
142 +
143 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_10.5.zip]]
144 +
145 +(% class="wikigeneratedid" %)
146 +**Bugs fixed**
147 +
148 +1. Slow response issue with IN series HMI;
149 +1. Slow response of alarm record and address monitoring table, and stuck when opening the project;
150 +1. LREAL data type cannot be read and written;
151 +1. The overlapping screen cannot be set when the sub-screen is selected in screen;
152 +1. The encoding method options for string type data in Data record;
153 +1. Communication failure on Ethernet2 of HMI when using IP address from different Subnets for Ethernet1 and Ethernet2.
154 +1. The addresses of X and Y are inconsistent in XY trend chart,;
155 +1. Object lock cannot be an index address;
156 +1. Lagging display of camera;
157 +1. Stuck on logo issue during IN, IE series upgrade;
158 +1. The IN series HMI do not support the mouse style configuration;
159 +1. Failure to download projects to IN series HMI ;
160 +1. PDF prompts display abnormal;
161 +1. CAN port configuration communication error;
162 +1. When RH device uses 4K resolution, the fonts of message prompt, background, etc. are too small;
163 +1. The issue of translator multi-language;
164 +1. Invalid address mapping;
165 +1. The advanced configuration effect of device search, device management and cloud management download project not match the expected results;
166 +1. RH-00 communication configuration does not have ETH2 configuration;
167 +1. The ig model system keyboard is not working;
168 +1. The ig, RH series vertical screen mouse movement and touch optimized;
169 +1. 4.3-inch HMI vertical screen background display effect;
170 +1. Issue of Siemens S7-1200 DBS register reads and writes less than half, need to check the ”Read DWord” option;
171 +1. OPC UA Client reads and writes strings issue, if the new string is shorter than the old one, the end of the old string will be remained;
172 +1. If using too many element in recipe for JUNCAUTO protocol, the address will be clean and overwrite the data in low addresses;
173 +1. Write LX5V bit-in-word;
174 +1. OPC UA Client cannot connect to the server configured with authentication;
175 +1. OPC UA Client cannot reconnect normally after unplugging/plugging the network cable;
176 +1. Changing communication methods in the background is invalid;
177 +1. Set user permissions on the screen, but the register cannot jump to this screen;
178 +1. The issue of abnormal using indirect screen on sub-screen;
179 +1. Abnormal display of the bar graph ;
180 +1. The RH series cannot use the CODESYS protocol;
181 +1. When the simulator's print object is set to screenshot mode, the screen cannot be switched after a screenshot.
182 +1. Operation records do not support text variable insert;
183 +1. Object or font shrinking when moving numeric object;
184 +1. CODESYS V3 protocol cannot read the Unicode string of LX6C (WSTRING);
185 +1. The issue with the UNION type data in Omron;
186 +1. Communication failure after the end of VPN pass-through, ;
187 +1. Communication failure between Keyence KV series protocol and 9000ig series;
188 +1. Gallery size limitation per screen for IN, IE and RH series;
189 +1. Other issues;
190 +
191 +(% class="wikigeneratedid" %)
192 +**New functions**
193 +
194 +(% class="wikigeneratedid" %)
195 +PC Software
196 +
197 +1. Software style selection;
198 +1. Screen layer;
199 +1. Template screen;
200 +1. Project tree objects list;
201 +1. Software settings page;
202 +1. The color palette adds a color picker;
203 +1. Address priority configuration;
204 +1. German is added to the software language;
205 +1. Automatic project backup;
206 +1. Address list search replacement;
207 +1. Import and export of user login information;
208 +1. The toolbar adds an upload project entrance and a toolbox entrance;
209 +1. UI enhancement;
210 +1. Software toolbar layout optimized;
211 +1. Address compilation optimized;
212 +1. Address integration optimized;
213 +1. Project multi-language translation(Only Baidu API key);
214 +1. Sound library configuration;
215 +1. BACNet server;
216 +1. Address search and replace;
217 +1. String table text alignment;
218 +1. Support for string table configuration
219 +1*. Drop-down list;
220 +1*. Data Record (channel name);
221 +1*. Recipe(element name);
222 +1*. Bit alarm text;
223 +1*. Word alarm text;
224 +1. Object copy attributes (font/size/color) to other languages;
225 +1. Project format upgrade.(.pi to .pi2)
226 +1. After the communication port connection is deleted, the communication port number is automatically sorted;
227 +1. Sub-screen pops up coordinate configuration;
228 +1. Alarm address communication priority (import/export);
229 +1. Text tag function;
230 +1. Text position vertical adjustment;
231 +1. Beckhoff tag import filtering;
232 +1. Schedule ;
233 +1. Column Chart object;
234 +1. Improve the success rate of pass-through;
235 +
236 +(% class="wikigeneratedid" %)
237 +HMI Application
238 +
239 +1. NTP time synchronization;
240 +1. New touch calibration interface;
241 +1. Sub screen modal mode;
242 +1. Exclusive operation;
243 +1. Watchdog;
244 +1. New Alarm Record;
245 +1*. New alarm record interface;
246 +1*. Alarm record ascending/descending order;
247 +1*. Alarm record statistics;
248 +1*. Diverse Alarm record styles;
249 +1. Media player;
250 +1. Mouse cursor style;
251 +1. Timeout NC effect;
252 +1. Sub-screen drag-and-drop;
253 +1. Minimum pressing interval time countdown tips UI;
254 +1. Additional options for trigger write addresses in alarm records;
255 +1. UNICODE and GBK display format are added to alarm variables;
256 +1. User permissions can configure the time of auto logout;
257 +1. Text-To-Speech;
258 +1. Voice broadcast;
259 +1. The message prompt module supports 48 languages;
260 +1. Remote management module in the background;
261 +1*. Remote background;
262 +1*. Access verification;
263 +1*. IP Whitelist/Blacklist;
264 +1*. Access log viewing;
265 +1. Configure network routing mode, switch mode and WIFI hotspot in the background
266 +1. RH series, 9000ig series DIP switch function
267 +1*. Factory reset
268 +1*. Touch calibration adaptation;
269 +1. Vertical alignment method for text display;
270 +1. Column Chart;
271 +1. Text tag function;
272 +1. Supports control via special registers to adjust the button size and spacing on the new Alarm record object, new Recipe Record object, and Column Chart;
273 +1. The text for email content, user login (username), user login (description), and log message text (operation records) supports configuration via a string table.
274 +1. Task scheduler;
275 +1. Sub-screen pop-up position optimization;
276 +1. RE and RL series support NTP (network time protocol) function;
277 +
278 +(% class="wikigeneratedid" %)
279 +**New drive**
280 +
281 +1. Winding Machine MODBUS RTU Winder;
282 +1. KEYENCE EtherNet/IP (KV-8000);
283 +1. KEYENCE EtherNet/IP (KV-X310);
284 +1. KEYENCE EtherNet/IP (KV-X520);
285 +1. INOVANCE H5U PLC Ethernet FreeTag (fast) replaces INOVANCE H5U PLC Ethernet FreeTag ;
286 +1. Siemens Ethernet FreeTag (S7 Series);
287 +1. LAICARD RFID Reader;
288 +1. KEYENCE Scanner HR-100B;
289 +1. KEYENCE Scanner HR-100;
290 +1. RONGSHI RFID Reader;
291 +1. KCJ RFID Reader;
292 +1. BACnet_IP;
293 +1. HONEYWELL Scanner 1902-C;
294 +1. Read interval time setting (RwDelay register) for modbus rtu slave.
295 +1. Expanded SD,SM register address range (up to 511) for INVT_IVC1.
296 +1. Leadshine LEISHINE _ SC-C32A4DS ModbusTcp;
297 +1. Leadshine LEISHINE _ SC-C32A4DS ModbusRTU;
298 +1. FANUC protocol;
299 +1. NEWLAND Scanner;
300 +1. NEWLAND Scanner COM;
301 +1. Leadshine LEISHINE _ LC1000 _ Series _ TCP;
302 +1. Leadshine LEISHINE _ LC1000 _ Series _ RTU;
303 +1. ModBus RTU Slave (All Fuction)~-~-RwDelay register for controlling send/receive interval;
304 +1. MITSUBISHI FX5U Ethernet—Bit-in-Word;
305 +1. Expanded SD, SM register range for INVT_IVC1 protocol;
306 +1. New CODESYS V3 protocol-read Unicode strings (WSTRING data type);
307 +
308 +(% class="wikigeneratedid" %)
309 +**New models**
310 +
311 +1. GB series: GB3041, GB3070, GB3101, GB8041, GB8070-H, GB8101;
312 +1. ig series: PI9102ig, PI9121ig, PI9150ig, PI9151ig;
313 +1. WP series: WP2070, WP2071, WP3070, WP3071;
314 +1. MD series: MD8102;
315 +1. RL series: RL-G, RL-WF;
316 +1. RH series: RH-00, RH-00-4K, RH-AG, RH-G, RH-W, RH-WG, RH-WG-CNC, RH-WG-E, RH-WG-LA, RH-WIFI;
317 +
318 +== **V9.5.9.25091702** ==
319 +
320 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.5.9.25091702.zip]]
321 +
322 +(% class="box errormessage" %)
323 +(((
324 +**Notice**
325 +
326 +1. The new version can not support general series(PI3000,PI8000,PI9000). Please use the old version (Release Build VER:R05R998_V8.4.114_D24061301) to program the general series.
327 +1. **After the upgrade, only the ig series can use the Lua MQTT library.**
328 +1. Projects opened with the new version cannot be opened with the old version. Please make sure to back up the project.
329 +1. After the upgrade, the supported protocols will change. PI3000ig can not support the third-part Free-tags Protocol.**For details, please refer to: [[Limitation of the Ethernet communication protocol - Wecon>>url:https://docs.we-con.com.cn/bin/view/PIStudio/PLC Protocol/Limitation of the Ethernet communication protocol/]]**
330 +1. Cannot roll back the version after upgrading.
331 +)))
332 +
333 +**Bugs fixed**
334 +
335 +1. i Series 485_2 communication issues;
336 +1. Pie chart control lag issues under certain circumstances;
337 +1. Remote monitoring issues with the mobile app and PC client software causing link errors;
338 +1. Other issues;
339 +
340 +**New functions**
341 +
342 +Cloud configuration supports Asian 2.0 servers;
343 +
4 4  == **V9.4.13.25053001** ==
5 5  
6 6  * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.4.13.25053001.zip]]
... ... @@ -748,7 +748,7 @@
748 748  
749 749  == V8.2.95_D20220928 ==
750 750  
751 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220928.zip]]
1091 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.2.95.22092802.zip]]
752 752  
753 753  (% class="wikigeneratedid" id="HBugsfixed" %)
754 754  **Bugs fixed**
... ... @@ -1112,5 +1112,6 @@
1112 1112  
1113 1113  = **4 StartupLogoTool** =
1114 1114  
1455 +* V3.0.24: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/StartupLogoTool%20v3.0.24.zip]] (Support RH series)
1115 1115  * V3.0.19: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/StartupLogoTool%20V3.0.19.zip]]
1116 1116  * old version: [[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]