Changes for page 3 Software
Last modified by Hunter on 2025/11/24 09:49
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. joe1 +XWiki.Hunter - Content
-
... ... @@ -1,6 +1,216 @@ 1 +((( 1 1 = **1 PIStudio** = 3 +))) 2 2 5 +((( 6 +== **V10.5.45.25102301(PI9000ig, RL, RH, WP)** == 7 +))) 3 3 9 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_10.5.zip]] 10 + 11 +{{warning}} 12 +This test version software is only available for the following models: PI9000ig series, RL series, RH series, and WP series. For all other models, the released version is recommended as the first priority. 13 +{{/warning}} 14 + 15 +(% class="wikigeneratedid" %) 16 +**Bugs fixed** 17 + 18 +1. Slow response issue with IN series HMI; 19 +1. Slow response of alarm record and address monitoring table, and stuck when opening the project; 20 +1. LREAL data type cannot be read and written; 21 +1. The overlapping screen cannot be set when the sub-screen is selected in screen; 22 +1. The encoding method options for string type data in Data record; 23 +1. Communication failure on Ethernet2 of HMI when using IP address from different Subnets for Ethernet1 and Ethernet2. 24 +1. The addresses of X and Y are inconsistent in XY trend chart,; 25 +1. Object lock cannot be an index address; 26 +1. Lagging display of camera; 27 +1. Stuck on logo issue during IN, IE series upgrade; 28 +1. The IN series HMI do not support the mouse style configuration; 29 +1. Failure to download projects to IN series HMI ; 30 +1. PDF prompts display abnormal; 31 +1. CAN port configuration communication error; 32 +1. When RH device uses 4K resolution, the fonts of message prompt, background, etc. are too small; 33 +1. The issue of translator multi-language; 34 +1. Invalid address mapping; 35 +1. The advanced configuration effect of device search, device management and cloud management download project not match the expected results; 36 +1. RH-00 communication configuration does not have ETH2 configuration; 37 +1. The ig model system keyboard is not working; 38 +1. The ig, RH series vertical screen mouse movement and touch optimized; 39 +1. 4.3-inch HMI vertical screen background display effect; 40 +1. Issue of Siemens S7-1200 DBS register reads and writes less than half, need to check the ”Read DWord” option; 41 +1. OPC UA Client reads and writes strings issue, if the new string is shorter than the old one, the end of the old string will be remained; 42 +1. If using too many element in recipe for JUNCAUTO protocol, the address will be clean and overwrite the data in low addresses; 43 +1. Write LX5V bit-in-word; 44 +1. OPC UA Client cannot connect to the server configured with authentication; 45 +1. OPC UA Client cannot reconnect normally after unplugging/plugging the network cable; 46 +1. Changing communication methods in the background is invalid; 47 +1. Set user permissions on the screen, but the register cannot jump to this screen; 48 +1. The issue of abnormal using indirect screen on sub-screen; 49 +1. Abnormal display of the bar graph ; 50 +1. The RH series cannot use the CODESYS protocol; 51 +1. When the simulator's print object is set to screenshot mode, the screen cannot be switched after a screenshot. 52 +1. Operation records do not support text variable insert; 53 +1. Object or font shrinking when moving numeric object; 54 +1. CODESYS V3 protocol cannot read the Unicode string of LX6C (WSTRING); 55 +1. The issue with the UNION type data in Omron; 56 +1. Communication failure after the end of VPN pass-through, ; 57 +1. Communication failure between Keyence KV series protocol and 9000ig series; 58 +1. Gallery size limitation per screen for IN, IE and RH series; 59 +1. Other issues; 60 + 61 +(% class="wikigeneratedid" %) 62 +**New functions** 63 + 64 +(% class="wikigeneratedid" %) 65 +PC Software 66 + 67 +1. Software style selection; 68 +1. Screen layer; 69 +1. Template screen; 70 +1. Project tree objects list; 71 +1. Software settings page; 72 +1. The color palette adds a color picker; 73 +1. Address priority configuration; 74 +1. German is added to the software language; 75 +1. Automatic project backup; 76 +1. Address list search replacement; 77 +1. Import and export of user login information; 78 +1. The toolbar adds an upload project entrance and a toolbox entrance; 79 +1. UI enhancement; 80 +1. Software toolbar layout optimized; 81 +1. Address compilation optimized; 82 +1. Address integration optimized; 83 +1. Project multi-language translation(Only Baidu API key); 84 +1. Sound library configuration; 85 +1. BACNet server; 86 +1. Address search and replace; 87 +1. String table text alignment; 88 +1. Support for string table configuration 89 +1*. Drop-down list; 90 +1*. Data Record (channel name); 91 +1*. Recipe(element name); 92 +1*. Bit alarm text; 93 +1*. Word alarm text; 94 +1. Object copy attributes (font/size/color) to other languages; 95 +1. Project format upgrade.(.pi to .pi2) 96 +1. After the communication port connection is deleted, the communication port number is automatically sorted; 97 +1. Sub-screen pops up coordinate configuration; 98 +1. Alarm address communication priority (import/export); 99 +1. Text tag function; 100 +1. Text position vertical adjustment; 101 +1. Beckhoff tag import filtering; 102 +1. Schedule ; 103 +1. Column Chart object; 104 +1. Improve the success rate of pass-through; 105 + 106 +(% class="wikigeneratedid" %) 107 +HMI Application 108 + 109 +1. NTP time synchronization; 110 +1. New touch calibration interface; 111 +1. Sub screen modal mode; 112 +1. Exclusive operation; 113 +1. Watchdog; 114 +1. New Alarm Record; 115 +1*. New alarm record interface; 116 +1*. Alarm record ascending/descending order; 117 +1*. Alarm record statistics; 118 +1*. Diverse Alarm record styles; 119 +1. Media player; 120 +1. Mouse cursor style; 121 +1. Timeout NC effect; 122 +1. Sub-screen drag-and-drop; 123 +1. Minimum pressing interval time countdown tips UI; 124 +1. Additional options for trigger write addresses in alarm records; 125 +1. UNICODE and GBK display format are added to alarm variables; 126 +1. User permissions can configure the time of auto logout; 127 +1. Text-To-Speech; 128 +1. Voice broadcast; 129 +1. The message prompt module supports 48 languages; 130 +1. Remote management module in the background; 131 +1*. Remote background; 132 +1*. Access verification; 133 +1*. IP Whitelist/Blacklist; 134 +1*. Access log viewing; 135 +1. Configure network routing mode, switch mode and WIFI hotspot in the background 136 +1. RH series, 9000ig series DIP switch function 137 +1*. Factory reset 138 +1*. Touch calibration adaptation; 139 +1. Vertical alignment method for text display; 140 +1. Column Chart; 141 +1. Text tag function; 142 +1. Supports control via special registers to adjust the button size and spacing on the new Alarm record object, new Recipe Record object, and Column Chart; 143 +1. The text for email content, user login (username), user login (description), and log message text (operation records) supports configuration via a string table. 144 +1. Task scheduler; 145 +1. Sub-screen pop-up position optimization; 146 +1. RE and RL series support NTP (network time protocol) function; 147 + 148 +(% class="wikigeneratedid" %) 149 +**New drive** 150 + 151 +1. Winding Machine MODBUS RTU Winder; 152 +1. KEYENCE EtherNet/IP (KV-8000); 153 +1. KEYENCE EtherNet/IP (KV-X310); 154 +1. KEYENCE EtherNet/IP (KV-X520); 155 +1. INOVANCE H5U PLC Ethernet FreeTag (fast) replaces INOVANCE H5U PLC Ethernet FreeTag ; 156 +1. Siemens Ethernet FreeTag (S7 Series); 157 +1. LAICARD RFID Reader; 158 +1. KEYENCE Scanner HR-100B; 159 +1. KEYENCE Scanner HR-100; 160 +1. RONGSHI RFID Reader; 161 +1. KCJ RFID Reader; 162 +1. BACnet_IP; 163 +1. HONEYWELL Scanner 1902-C; 164 +1. Read interval time setting (RwDelay register) for modbus rtu slave. 165 +1. Expanded SD,SM register address range (up to 511) for INVT_IVC1. 166 +1. Leadshine LEISHINE _ SC-C32A4DS ModbusTcp; 167 +1. Leadshine LEISHINE _ SC-C32A4DS ModbusRTU; 168 +1. FANUC protocol; 169 +1. NEWLAND Scanner; 170 +1. NEWLAND Scanner COM; 171 +1. Leadshine LEISHINE _ LC1000 _ Series _ TCP; 172 +1. Leadshine LEISHINE _ LC1000 _ Series _ RTU; 173 +1. ModBus RTU Slave (All Fuction)~-~-RwDelay register for controlling send/receive interval; 174 +1. MITSUBISHI FX5U Ethernet—Bit-in-Word; 175 +1. Expanded SD, SM register range for INVT_IVC1 protocol; 176 +1. New CODESYS V3 protocol-read Unicode strings (WSTRING data type); 177 + 178 +(% class="wikigeneratedid" %) 179 +**New models** 180 + 181 +1. GB series: GB3041, GB3070, GB3101, GB8041, GB8070-H, GB8101; 182 +1. ig series: PI9102ig, PI9121ig, PI9150ig, PI9151ig; 183 +1. WP series: WP2070, WP2071, WP3070, WP3071; 184 +1. MD series: MD8102; 185 +1. RL series: RL-G, RL-WF; 186 +1. RH series: RH-00, RH-00-4K, RH-AG, RH-G, RH-W, RH-WG, RH-WG-CNC, RH-WG-E, RH-WG-LA, RH-WIFI; 187 + 188 +== **V9.5.9.25091702** == 189 + 190 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.5.9.25091702.zip]] 191 + 192 +(% class="box errormessage" %) 193 +((( 194 +**Notice** 195 + 196 +1. The new version can not support general series(PI3000,PI8000,PI9000). Please use the old version (Release Build VER:R05R998_V8.4.114_D24061301) to program the general series. 197 +1. **After the upgrade, only the ig series can use the Lua MQTT library.** 198 +1. Projects opened with the new version cannot be opened with the old version. Please make sure to back up the project. 199 +1. After the upgrade, the supported protocols will change. PI3000ig can not support the third-part Free-tags Protocol.**For details, please refer to: [[Limitation of the Ethernet communication protocol - Wecon>>url:https://docs.we-con.com.cn/bin/view/PIStudio/PLC Protocol/Limitation of the Ethernet communication protocol/]]** 200 +1. Cannot roll back the version after upgrading. 201 +))) 202 + 203 +**Bugs fixed** 204 + 205 +1. i Series 485_2 communication issues; 206 +1. Pie chart control lag issues under certain circumstances; 207 +1. Remote monitoring issues with the mobile app and PC client software causing link errors; 208 +1. Other issues; 209 + 210 +**New functions** 211 + 212 +Cloud configuration supports Asian 2.0 servers; 213 + 4 4 == **V9.4.13.25053001** == 5 5 6 6 * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.4.13.25053001.zip]]