Changes for page 3 Software

Last modified by Jett on 2025/03/13 14:13

From version 35.1
edited by Jett
on 2025/02/08 16:44
Change comment: There is no comment for this version
To version 29.1
edited by Jett
on 2025/01/06 10:14
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,98 +4,6 @@
4 4  
5 5  * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.1.18.24122702.zip]]
6 6  
7 -(% class="box infomessage" %)
8 -(((
9 -**Notice**
10 -
11 -1. The new version can not support general series(PI3000,PI8000,PI9000). Please use the old version (Release Build VER:R05R998_V8.4.114_D24061301) to program the general series.
12 -1. Projects opened with the new version cannot be opened with the old version. Please make sure to back up the project.
13 -1. After the upgrade, the supported protocols will change. **For details, please refer to: [[Limitation of the Ethernet communication protocol - Wecon>>url:https://docs.we-con.com.cn/bin/view/PIStudio/PLC Protocol/Limitation of the Ethernet communication protocol/]]**
14 -1. Cannot roll back the version after upgrading.
15 -)))
16 -
17 -**Bugs fixed**
18 -
19 -1. RE series V-BOX PLC Pass-through sometime can't work properly.
20 -1. RE series V-BOX data record upload can't work properly.
21 -1. PI8043ig and PI3041ig recipe object unable to display properly in web side.
22 -1. When entering the backstage for the first time after the screen is restarted, the first digit of the backstage password is invalid.
23 -1. PI8043ig project file is too large to the logo is stuck when HMI restarted.
24 -1. WIFI model can not enable after update the system.
25 -1. HMI crash and freeze when downloading PLC project.
26 -1. When the rectangle/arc/circle object is first initialized, a shadow will appears.
27 -1. The cloud icon in backstage state error.
28 -1. In off-line simulation.The left lable of Numeric Input/Display object affect natural decimal display.
29 -1. MQTT tool publish bit address,the length setting is not 1,message error.
30 -1. MQTT V5 protocol cannot automatically connect after network disconnection.
31 -1. The cloud management tool cannot log in to non-administrator users normally.
32 -1. Object lock does not work for bit switch momentary mode.
33 -1. WIFI is not connected, but IP still exists.
34 -1. The actual minimum pressing time of the function switch does not match the setting.
35 -1. RH-WF V-BOX indicator lamp display error.
36 -1. Data record display object start time setting error.
37 -1. The camera display object disappear after switching screens.
38 -1. After using the four arithmetic operations in address mapping, reading the value in read-only mode displays an abnormality.
39 -1. Object level password does not match the setting.
40 -1. In offline simulation, the new recipe tool crashes by clicking keyboard letters.
41 -1. Recipe name changes when switching screens.
42 -1. PLC program upload fails when PLC Pass-Through.
43 -1. IDEC MicroSmart Protocol:TC CC register modifying the value of the address results in an error in the value of the next address.
44 -1. Delta_AS300_TCP Protocol:D.b register cannot modify status.
45 -1. OPCUA Client:communication error but have no time-out message.
46 -1. IEC104client:HMI get black screen after downloading this protocol.
47 -
48 -**New functions**
49 -
50 -PC Software
51 -
52 -1. New project properties page.
53 -1. i/ie/ig/IN/RE/RH series all support screen style.
54 -1. Download tool support RE,RH series flash light and test network.
55 -1. New Device management tool.
56 -1. Software homepage embedded Wecon support center.
57 -1. Allow configuration preserve network configuration when download the project.
58 -1. Software online update.
59 -1. Scada canvas extension, new draft area.
60 -1. Recipe element support bit address.
61 -1. OPC UA server.
62 -1. New X,Y internal registers(RH series).
63 -1. 3000ig series Limitation of the Ethernet communication protocol up to 32.
64 -
65 -HMI Application
66 -
67 -1. New recipe object-Recipe Record:Integrated search, add, delete, download, upload, import, export, and switch recipe functions.
68 -1. New backstage:The background can be exited instead of restarted,New UI,Ethernet download PLC program,USB update support update the system and project at the same time.
69 -1. Remote backstage.
70 -1. New system keyboard.
71 -1. Character Input/Display object support multi line display.
72 -1. Character Input/Display object support choose data format(UTF-8/GBK/UNICODE).
73 -1. Numeric Input/Display object support more 64bit data format.
74 -1. Modification of serial port parameters takes effect immediately.
75 -1. RE series can be bound to V-NET.
76 -1. lua script open user permission function interface.
77 -1. New Multi-link function.
78 -1. New special registers related to automatic logout of user functionse.
79 -1. Alarm info support multiple variables.
80 -1. Min.hold time countdown.
81 -1. ig-O support Wecon 6V freetags protocol and CODESYS V3 protocol.
82 -1. (((
83 -New special registers related to displaying user storage space information.
84 -)))
85 -
86 -Driver protocol
87 -
88 -1. OPCUA Client.
89 -1. Siemens S7-1200/1500 Ethernet FreeTag.
90 -1. TwinCAT PLC Ethernet.
91 -1. KEYENCE KV-5000(Ethernet) using bit address in word address.
92 -
93 -**New model**
94 -
95 -1. RE series:RE-00,RE-00-LA,RE-4G,RE-4G-LA
96 -1. RH series:RH-WIFI
97 -1. ig series:PI3101ig,PI8101ig,PI8121ig
98 -
99 99  == **V8.4.114_D24061301** ==
100 100  
101 101  * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.114.24061301.zip]]