Changes for page 3 Software

Last modified by Jett on 2025/03/13 14:13

From version 37.1
edited by Jett
on 2025/02/08 16:48
Change comment: There is no comment for this version
To version 21.1
edited by Devin Chen
on 2023/11/15 17:23
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.2454238480
1 +XWiki.DevinChen
Content
... ... @@ -1,194 +1,5 @@
1 1  = **1 PIStudio** =
2 2  
3 -== **V9.1.18.24122702** ==
4 -
5 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.1.18.24122702.zip]]
6 -
7 -(% class="box errormessage" %)
8 -(((
9 -**Notice**
10 -
11 -1. The new version can not support general series(PI3000,PI8000,PI9000). Please use the old version (Release Build VER:R05R998_V8.4.114_D24061301) to program the general series.
12 -1. Projects opened with the new version cannot be opened with the old version. Please make sure to back up the project.
13 -1. After the upgrade, the supported protocols will change. **For details, please refer to: [[Limitation of the Ethernet communication protocol - Wecon>>url:https://docs.we-con.com.cn/bin/view/PIStudio/PLC Protocol/Limitation of the Ethernet communication protocol/]]**
14 -1. Cannot roll back the version after upgrading.
15 -)))
16 -
17 -**Bugs fixed**
18 -
19 -1. RE series V-BOX PLC Pass-through sometime can't work properly.
20 -1. RE series V-BOX data record upload can't work properly.
21 -1. PI8043ig and PI3041ig recipe object unable to display properly in web side.
22 -1. When entering the backstage for the first time after the screen is restarted, the first digit of the backstage password is invalid.
23 -1. PI8043ig project file is too large to the logo is stuck when HMI restarted.
24 -1. WIFI model can not enable after update the system.
25 -1. HMI crash and freeze when downloading PLC project.
26 -1. When the rectangle/arc/circle object is first initialized, a shadow will appears.
27 -1. The cloud icon in backstage state error.
28 -1. In off-line simulation.The left lable of Numeric Input/Display object affect natural decimal display.
29 -1. MQTT tool publish bit address,the length setting is not 1,message error.
30 -1. MQTT V5 protocol cannot automatically connect after network disconnection.
31 -1. The cloud management tool cannot log in to non-administrator users normally.
32 -1. Object lock does not work for bit switch momentary mode.
33 -1. WIFI is not connected, but IP still exists.
34 -1. The actual minimum pressing time of the function switch does not match the setting.
35 -1. RH-WF V-BOX indicator lamp display error.
36 -1. Data record display object start time setting error.
37 -1. The camera display object disappear after switching screens.
38 -1. After using the four arithmetic operations in address mapping, reading the value in read-only mode displays an abnormality.
39 -1. Object level password does not match the setting.
40 -1. In offline simulation, the new recipe tool crashes by clicking keyboard letters.
41 -1. Recipe name changes when switching screens.
42 -1. PLC program upload fails when PLC Pass-Through.
43 -1. IDEC MicroSmart Protocol:TC CC register modifying the value of the address results in an error in the value of the next address.
44 -1. Delta_AS300_TCP Protocol:D.b register cannot modify status.
45 -1. OPCUA Client:communication error but have no time-out message.
46 -1. IEC104client:HMI get black screen after downloading this protocol.
47 -
48 -**New functions**
49 -
50 -PC Software
51 -
52 -1. New project properties page.
53 -1. i/ie/ig/IN/RE/RH series all support screen style.
54 -1. Download tool support RE,RH series flash light and test network.
55 -1. New Device management tool.
56 -1. Software homepage embedded Wecon support center.
57 -1. Allow configuration preserve network configuration when download the project.
58 -1. Software online update.
59 -1. Scada canvas extension, new draft area.
60 -1. Recipe element support bit address.
61 -1. OPC UA server.
62 -1. New X,Y internal registers(RH series).
63 -1. 3000ig series Limitation of the Ethernet communication protocol up to 32.
64 -
65 -HMI Application
66 -
67 -1. New recipe object-Recipe Record:Integrated search, add, delete, download, upload, import, export, and switch recipe functions.
68 -1. New backstage:The background can be exited instead of restarted,New UI,Ethernet download PLC program,USB update support update the system and project at the same time.
69 -1. Remote backstage.
70 -1. New system keyboard.
71 -1. Character Input/Display object support multi line display.
72 -1. Character Input/Display object support choose data format(UTF-8/GBK/UNICODE).
73 -1. Numeric Input/Display object support more 64bit data format.
74 -1. Modification of serial port parameters takes effect immediately.
75 -1. RE series can be bound to V-NET.
76 -1. lua script open user permission function interface.
77 -1. New Multi-link function.
78 -1. New special registers related to automatic logout of user functionse.
79 -1. Alarm info support multiple variables.
80 -1. Min.hold time countdown.
81 -1. ig-O support Wecon 6V freetags protocol and CODESYS V3 protocol.
82 -1. (((
83 -New special registers related to displaying user storage space information.
84 -)))
85 -
86 -Driver protocol
87 -
88 -1. OPCUA Client.
89 -1. Siemens S7-1200/1500 Ethernet FreeTag.
90 -1. TwinCAT PLC Ethernet.
91 -1. KEYENCE KV-5000(Ethernet) using bit address in word address.
92 -
93 -**New model**
94 -
95 -1. RE series:RE-00,RE-00-LA,RE-4G,RE-4G-LA
96 -1. RH series:RH-WIFI
97 -1. ig series:PI3101ig,PI8101ig,PI8121ig
98 -
99 -== **V8.4.114_D24061301** ==
100 -
101 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.114.24061301.zip]]
102 -
103 -**Bugs fixed**
104 -
105 -PC Software
106 -
107 -1. When the MQTT sending mode is set a trigger, entering the trigger address directly cannot save.
108 -1. Arc object property page configuration angle cannot enter 0.
109 -1. Add the 5V protocol first, and then add the printer's protocol, can't change the protocol of the printer.
110 -1. The value of the meter and the color of the scale are inconsistent.
111 -1. After decompile tool open, the software crash.
112 -1. Off-line emulator run time the pictures of function switch object do not display.
113 -1. After deleting multiple screens, the software crash.
114 -1. After copying the local screen successfully, the directly compiled screen objects will be smaller than the modified screen objects.
115 -1. The same project file can be opened by multiple software at the same time.
116 -1. Object id duplication.
117 -1. The bar graph does not use variables, but when compiling, it prompts the variable address error.
118 -1. Using dynamic recipients, email addresses are not compiled and display recipient errors.
119 -1. The objects compile with the address error, but there is no note about what the address error is for which objects.
120 -1. When the circle/ellipse coords are in the negative area, no error message is displayed.
121 -1. When text library imports excel,the blank space and subsequent data cannot be imported.
122 -1. The function screen is deleted and then add it again.it cannot be added.
123 -1. The wrong continuous length when compiling the address of the data record.
124 -1. The wrong continuous length of lua script.
125 -1. PI3041ig configuration Ethernet 2 does not take effect.
126 -1. The wrong coord prompt when the rectangular objects is determined.
127 -1. The data record storage in project setting is error.
128 -1. Fix other problems.
129 -
130 -HMI Application
131 -
132 -1. The function is invalid after the function switch is pressed;
133 -1. The lua function io.open cannot open files under the u disk and sd card;
134 -1. The data record configuration data type is a string, the length is two characters, and it will be recorded more than two characters when data is collected record.
135 -1. The data type of the word switch is BCD code, and the increase and decrease do not follow the rule of the BCD code.
136 -1. "Database Format Mismatch" error after Lua script modifies table header.
137 -1. PI3070ig printing part text box printing font is not clear.
138 -1. In the offline simulation state, the graphics position offset occurs in the project with 1920*1080 resolution when the graphics are drawn by the address control.
139 -1. drawing when the graphics position offset.
140 -1. Receiving Data in Lua User Free Protocol 485 _ 2.
141 -1. Lua initialization uses the we_bas_jump screen function to jump to the screen is invalid, and there is a black screen.
142 -1. The data record cannot be recorded when the data record group id is 0.
143 -1. Value input objects check the display natural decimal function is invalid.
144 -1. To enable address control state text, must set the state sequence number, text content, and trigger settings.
145 -1. MQTT is published periodically, and changing the value of the address will also publish.
146 -1. The text on picture has a probability of becoming blurry.
147 -1. When the reset switch triggers hiding, it cannot automatically reset.
148 -1. Alarm records and data records are exported to CSV, and the table header does not switch with language switching.
149 -1. The screen alarm record csv exported using DbToCsvFile has no alarm content.
150 -1. The group number displayed in the recipe Group number address does not match the ID of the recipe display objects.
151 -1. When the number of recipe groups is set to 0, the file name address of the index does not change when there are multiple recipe files.
152 -1. The gallery is too large, causing crash.
153 -1. Drop down list username can't show multilingual.
154 -1. V-NET server anomaly causes device disconnection.
155 -1. The HMI goes off-line due to abnormal dialing of the 4G module.
156 -1. Recipe selected line ID does not match the ID in the address.
157 -1. The USB download project time is not updated, and the local time is not synchronized with the computer time.
158 -1. The keyboard screen cannot be closed normally through we_bas_closescreen function.
159 -1. The IE series uses calibri fonts and the screen display is in Song style.
160 -1. After setting floating setting as big-endian,the recipe table is displayed in Little-endian.
161 -1. Long press the bit switch, and then release the bit switch after entering the static screen saver , and the bit switch cannot be reset.
162 -1. After the function switch uses object password, the password is invalid after the screen jumps.
163 -1. PI8150ig makes the font size smaller when using calibri font.
164 -1. IN series long press upper left corner, upper right corner invalid.
165 -1. Fix other problems.
166 -
167 -Drive
168 -
169 -1. DELTA AS300 MODBUS TCP driver operation D.b bit address invalid.
170 -1. OMRONE5CC driver communication abnormal.
171 -1. Xunpu printer driver prints pictures abnormally.
172 -1. Rockwell Ethernet/IP (CompactLogix Series) driver communication exception.
173 -1. Siemens LOGO drive on-line simulation crash.
174 -1. Fix other problems.
175 -
176 -**New functions**
177 -
178 -Driver
179 -
180 -1. LS MASTER Protocol driver supports bit address selection of D register.
181 -1. TECO MP300 MODBUS TCP protocol.
182 -1. TECO MP300 MODBUS RTU protocol.
183 -
184 -**Precautions**
185 -
186 -Drive 
187 -
188 -✎Note: WECON LX6V FreeTag Ethernet will not be maintained in the future, please switch to WECON LX6V EtherNet/IP.
189 -
190 -✎Note: WECON LX6V FreeTag Series will not be maintained in the future, please switch to Ethernet WECON LX6V EtherNet/IP
191 -
192 192  == V8.4.66_D23102001 ==
193 193  
194 194  * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.66.23102001.zip]]
1717728415376-899.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.2454238480
Size
... ... @@ -1,1 +1,0 @@
1 -56.5 KB
Content