... ... @@ -1,242 +1,375 @@
1 -= **1 PIStudio Release Build VER:R05R998_V7.2.198_D20211210** =
1 += **1 PIStudio** =
2 2  
3 -(% class="wikigeneratedid" %)
4 -**Official Website:**
3 +== V8.2.95_D20220928 ==
5 5  
6 -(% class="wikigeneratedid" %)
7 -**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]]**
5 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/HMIEditorP20220928.zip]]
8 8  
9 -**Google Drive:**
7 +(% class="wikigeneratedid" id="HBugsfixed" %)
8 +**Bugs fixed**
10 10  
11 -**[[Download Link>>https://drive.google.com/file/d/1lRfgoOwAs7lgL4b-ZdVUvE6itHWCpfd5/view?usp=sharing]]**
10 +(% class="wikigeneratedid" %)
11 +PC Software
12 12  
13 -== **1.1 Bugs Fixed** ==
13 +1. Optimize the function of saving project as;
14 +1. The word alarm configuration cannot be imported after being exported;
15 +1. The problem of abnormal resolution after png image editing and external import; 
16 +1. The password of project designer can be input into Chinese;
17 +1. The 8150ig model cannot be configured with camera search function;
18 +1. The probability of recipe setting cannot be saved;
19 +1. When simulating the "WECON" directory of C disk is adjusted to "HMIEmulation" directory;
20 +1. The problem that the position of text parts does not change after setting coordinates;
21 +1. The interface displays an redundant scroll bar when creating a new screen;
22 +1. The download tool only scans one of the network segments when there are multiple ip under the computer network card;
23 +1. The content of data records is abnormal and cannot be imported after being exported;
24 +1. The welcome interface opens the project and incorrectly prompts the project to be occupied;
25 +1. The installation path affects clicking offline simulation to pop up online simulation;
26 +1. The font size of the newly built-in screen 5004 is abnormal when switching to the size of 1920*1080;
27 +1. When the data record is stored in U disk and SD card, the size of the data record is not limited during compilation;
28 +1. The name of the newly created part in the right-click menu bar is consistent with the name in the part list;
29 +1. The problem that when compiling ie series projects, the memory size of the components of the picture exceeds the problem that no error is reported;
30 +1. When the U disk upgrade tool selects an invalid drive letter to generate a file, it does not normally prompt errors;
31 +1. The prompting wrong parameters when opening engineering parameters in the project of repairing vertical screen;
14 14  
15 -=== **1.1.1 PC Software** ===
33 +(% class="wikigeneratedid" %)
34 +HMI Application
16 16  
17 -A) Optimize the display style of text objects;
36 +1. Keyboard without "&" the question of symbols;
37 +1. The camera function on HMI V2.0 system will report error messages;
38 +1. The camera picture is still displayed after switching pictures on HMI V2.0 system;
39 +1. The project of Chinese character designer password cannot be simulated;
40 +1. The screenshots of printed parts are invalid when saved to SD card;
41 +1. The project downloaded by Ethernet cannot be uploaded normally;
42 +1. The debugging window moves the left and right scroll bars, and the upper and lower scroll bars will jump to the bottom;
43 +1. The manual setting of 4G APN in the background, which cannot be saved;
44 +1. The system is upgraded to V2.0, the horizontal and vertical screens are abnormal;
45 +1. PI3043ie can't communicate with plc after upgrading;
46 +1. HMI2.0 background dynamic and static switch does not cache static IP;
47 +1. PI3070ig ftpserver can't access the service;
48 +1. V-BOX can't download PI3070N through download;
49 +1. The starting time will automatically change after the data record query setting interface pops up;
50 +1. The flow component displaying deviation in web pages;
51 +1. The alarm record header of switching language is not switched;
52 +1. The current alarm record will show the problem of historical alarm record;
53 +1. The camera uses power failure to save the address, and the camera state is not initialized after power failure and restart;
54 +1. The camera directly enters the account number, password and device serial number without enabling the search module;
55 +1. PI audio plays with sound and the volume is displayed as 0;
56 +1. When the hot spot name of the connection has single quotation marks, the network cannot recognize the problem;
57 +1. Add background U Disk upgrade updates the network configuration function (downloads the Ethernet parameters in the project parameters synchronously to the HMI
58 +1. The ig series can't use ezviz cloud function when using 4G Internet of Things card to surf the Internet;
59 +1. The screen saver cannot be exited on HMI V2.0 system;
60 +1. The communication is disconnected and cannot be reconnected after ig series VPN penetrates;
61 +1. Optimize the polling speed of VB trigger script;
18 18  
19 -B) Optimize Lua script file size limitation to 512KB;
63 +Drive the updated
20 20  
21 -C) Optimize the import of text library and the limitation to 2000;
65 +1. The abnormal communication caused by recipe reading;
22 22  
23 -D) Protocol driver names standardized;
67 +Driver Protocol
24 24  
25 -E) Font size is open to 512;
69 +1. Add Omron (NX/NJ) free label driver;
26 26  
27 -F) Lua script debugging window can be configured as enabled or not in Project Settings;
71 +**New functions**
28 28  
29 -G) Optimize the font display of Runbar;
73 +PC Software
30 30  
31 -H) Optimized the forced backup function of project file, now you can click the cancel button to not backup;
75 +1. The picture compression function in the project parameters;
76 +1. Compatible switching models of PI8150ig (1920*1080 and 1280*720).
77 +1. The template picture with resolution of 1920*1080 of ig.
78 +1. ig series does not check the size limit of data record files.
32 32  
33 -I) Optimized and adjusted the default size of the password keyboard screen of newly-created projects;
80 +HMI Application
34 34  
35 -J) Wrong display range of the History trend chart;
82 +1. The rotation function of switch components (only supported by HMI V2.0 system);
83 +1. Automatic rotation of rotation bitmap control and address control hiding function (only supported by HMI V2.0 system);
84 +1. Ftp service function (only supported by HMI V2.0 system);
85 +1. Ezviz cloud camera function (only supported by HMI V2.0 system);
86 +1. Lua curve custom component sliding bar function and draw 8 curves (only supported by HMI V2.0 system);
87 +1. Background language boot configuration (only supported by HMI V2.0 system);
88 +1. The function of modifying the header of data records (only supported by HMI V2.0 system);
89 +1. Historical trend style 6 and style 7 (only supported by HMI V2.0 system);
90 +1. PI8150ig (1920*1080rn) resolution;
36 36  
37 -K) The font display of Drop-down List on PC is different from the actual screen;
38 38  
39 -L) Software crash caused by deleting the Address Library name;
93 +== V8.2.62_D20220625 ==
40 40  
41 -M) General Series SMS protocol cannot be selected;
95 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220625.zip]]
96 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/1kJuuzxjPj5mZmeazhGxrs3lGyMceqmYj/view?usp=sharing]]
42 42  
43 -=== **1.1.2 HMI Application** ===
98 +(% class="wikigeneratedid" id="HBugsfixed" %)
99 +**Bugs fixed**
44 44  
45 -A) Multi-Language display of text fonts;
101 +(% class="wikigeneratedid" id="HPCSoftware" %)
102 +PC Software
46 46  
47 -B) Password keyboard input to display the plain text first and then the * sign;
104 +1. Cloud.xml does not exist in the project file of 8000 series and cannot access cloud;
105 +1. Lua prompting error when double click the project path of General series in Screen Management;
106 +1. The cursor moving into the area of background script will be disappeared;
107 +1. After the Lua script is changed, it is not compiled, and there is no prompt when clicking offline simulation;
108 +1. DLView fails to import excel files;
109 +1. There is an abnormality when creating image files into Udisk;
110 +1. Orientation options missing for Slide switch;
111 +1. COM3 Configuration missing for following models: 3070i-A and 3102i-A;
112 +1. When the download tool downloads the project, it does not prompt when the file does not exist;
113 +1. SD Card option missing for following models: 3070i-A, 3102i-A, 3070i-C, 3102i-C;
114 +1. Some of the same font size, font style is different when the font size is displayed abnormally;
115 +1. Optimize the built-in screen No.1008, add Time and Date objects;
116 +1. Optimize the remote download;
117 +1. Optimize the U disk upgrade function;
118 +1. Prompt when the downloads a file with a long path;
119 +1. The ig series vertical screen option is available now;
48 48  
49 -C) Prompt display of Screen Lock for ie and ig;
121 +(% class="wikigeneratedid" id="HHMIApplication" %)
122 +HMI Application
50 50  
51 -D) Auto refresh of Data Record;
124 +1. The i series freezes with HSW24 soft reboot;
125 +1. Debugging window cannot be closed on the ig monitoring page;
126 +1. Abnormal record time of ig Data record;
127 +1. The ig series abnormal ethernet communication;
128 +1. The register for network status HSW850 abnormal value;
129 +1. Lua we_bas_getstring script function execution error;
130 +1. The video title with English brackets cannot be played;
131 +1. Touch screen will lead to HMI freezes when keyboard input and cursor is enabled;
132 +1. Logo failed download for PI8150ig (before the firmware version 0313);
133 +1. After PI8000 series remote download PLC program, PLC cannot communicate;
134 +1. PI8000 series and ig series online V-NET but cannot remote control;
135 +1. Background Ethernet static IP configuration is not saved;
136 +1. The ig series WVPN remote pass through fails;
137 +1. Lua timer does not perform timing operations according to the interval;
52 52  
53 -=== **1.1.3 Driver Protocol** ===
139 +(% class="wikigeneratedid" id="HDriverProtocol" %)
140 +Driver Protocol
54 54  
55 -A) Communication cannot be performed after entering the backstage project;
142 +1. PI8000ig and Yudian sensor cannot communicate;
143 +1. Modify the name of the Wecon LX6V protocol, the old version project must be re-selected;
144 +1. The following serial port protocols have intermittent communication timeout issue: Siemens S7-200 smart, modbus, INVT, etc.
145 +1. Taian AP200 C register can not read the value
56 56  
57 -B) Stuck screen problem caused by the protocol IEC60870-104 Client;
147 +(% class="wikigeneratedid" id="HNewfunctions" %)
148 +**New functions**
58 58  
59 -== **1.2 New Functions Added** ==
150 +(% class="wikigeneratedid" id="HPCSoftware-1" %)
151 +PC Software
60 60  
61 -=== **1.2.1 PC Software** ===
153 +1. VB script customize naming function;
154 +1. PI Suite toolkit;
155 +1. System upgrade function;
156 +1. PIRecordUpload has added User permission function;
157 +1. Cloud function of 8000 and 9000 series;
62 62  
63 -A) New ie series model: 3035ie;
159 +(% class="wikigeneratedid" id="HHMIApplication-1" %)
160 +HMI Application
64 64  
65 -B) New ig series models: 3070ig, 3102ig;
162 +The following function is only available for ig series:
66 66  
67 -C) License agreement for the software installation setup process;
164 +1. Slider of History trend chart can set the color and transparency;
165 +1. Continuous read and write addresses in Lua script;
166 +1. Built-in Lua extension module;
167 +1. Display network camera on HMI screen for 8150ig;
168 +1. Vertical Display;
169 +1. The priority settings of Cloud connection method from backstage configuration;
170 +1. Lua script supports https protocol now;
171 +1. UDisk Download project prohibit upload function;
172 +1. Lua script luasqlite operation;
173 +1. The following function is only available for i,ie,ig series and HMI+ system:
174 +1. All series remove the restriction of special machine code;
175 +1. Recipe 64-bit floating point number data format;
176 +1. UDisk Pop-Up function;
177 +1. Interconversion between GB2312 and UTF-8 encoding;
178 +1. UDisk download PLC multi-file function;
179 +1. Modifitable datetime prohibited;
180 +1. Color configuration of Line object;
68 68  
69 -D) Object Lock/Unlock function (Pushpin);
182 +(% class="wikigeneratedid" id="HDriverProtocol-1" %)
183 +Driver Protocol
70 70  
71 -E) Lua Editor to highlight the same content of the selected text;
185 +1. Inovance H3U Ethernet;
186 +1. Rockwell micro850 Ethernet/IP Free Tags;
187 +1. Wecon LX6V Free Tags;
72 72  
73 -F) Font style settings of the Runbar and chart type objects;
189 +(% class="wikigeneratedid" id="HNewmodels" %)
190 +**New models**
74 74  
75 -G) Software installation package VC 2017 runtime library;
192 +1. The i series: 3070i-A, 3102i-A, 3070i-C, 3102i-C, 3070i-2S, 3102i-2S
193 +1. The ie series: 3043ie-T
194 +1. The ig series: 8150ig
76 76  
77 -=== **1.2.2 HMI Application** ===
196 +(% class="box infomessage" %)
197 +(((
198 +✎Note:
78 78  
79 -A) Recipe address discontinuous address setting;
200 +* To use the new functions avaiable from new version, the project needs to be downloaded twice;
201 +* After the wifi module (version V1.1) of 3070ig is soft restarted, if the wifi is not recognized from background interface, please repower to recover it;
202 +)))
80 80  
81 -B) Trim 0 display setting for numeric input;
204 +== V7.2.198_D20211210 ==
82 82  
83 -C) Address Mapping continuous writing settings;
206 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]]
207 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/1lRfgoOwAs7lgL4b-ZdVUvE6itHWCpfd5/view?usp=sharing]]
84 84  
85 -D) Screensaver function;
209 +(% class="wikigeneratedid" id="HBugsfixed-1" %)
210 +**Bugs fixed**
86 86  
87 -E) Multi-Link function (not supported by ie and ig series);
212 +(% class="wikigeneratedid" id="HPCSoftware-2" %)
213 +PC Software
88 88  
89 -F) Traditional recipe function is only applicable to the LEVI2PI project that uses the Recipe function;
215 +* Optimize the display style of text objects;
216 +* Optimize Lua script file size limitation to 512KB;
217 +* Optimize the import of text library and the limitation to 2000;
218 +* Protocol driver names standardized;
219 +* Font size is open to 512;
220 +* Lua script debugging window can be configured as enabled or not in Project Settings;
221 +* Optimize the font display of Runbar;
222 +* Optimized the forced backup function of project file, now you can click the cancel button to not backup;
223 +* Optimized and adjusted the default size of the password keyboard screen of newly-created projects;
224 +* Wrong display range of the History trend chart;
225 +* The font display of Drop-down List on PC is different from the actual screen;
226 +* Software crash caused by deleting the Address Library name;
227 +* General Series SMS protocol cannot be selected;
90 90  
91 -G) Disc Record Chart;
229 +(% class="wikigeneratedid" id="HHMIApplication-2" %)
230 +HMI Application
92 92  
93 -H) Lua script weather forecast function interfaces;
232 +* Multi-Language display of text fonts;
233 +* Password keyboard input to display the plain text first and then the * sign;
234 +* Prompt display of Screen Lock for ie and ig;
235 +* Auto refresh of Data Record;
94 94  
95 -I) The ie series supports the barcode scanner;
237 +(% class="wikigeneratedid" id="HDriverProtocol-2" %)
238 +Driver Protocol
96 96  
97 -=== **1.2.3 Driver Protocol** ===
240 +* Communication cannot be performed after entering the backstage project;
241 +* Stuck screen problem caused by the protocol IEC60870-104 Client;
98 98  
99 -A) Koyo Modbus RTU;
243 +(% class="wikigeneratedid" id="HNewfunctions-1" %)
244 +**New functions**
100 100  
101 -B) ASK series;
246 +(% class="wikigeneratedid" id="HPCSoftware-3" %)
247 +PC Software
102 102  
103 -C) Anda inverter;
249 +* New ie series model: 3035ie;
250 +* New ig series models: 3070ig, 3102ig;
251 +* License agreement for the software installation setup process;
252 +* Object Lock/Unlock function (Pushpin);
253 +* Lua Editor to highlight the same content of the selected text;
254 +* Font style settings of the Runbar and chart type objects;
255 +* Software installation package VC 2017 runtime library;
104 104  
105 -D) Optimize the barcode scanner protocol;
257 +(% class="wikigeneratedid" id="HHMIApplication-3" %)
258 +HMI Application
106 106  
107 -= **PIStudio Release Build VER:R05R998_V7.1.117_D20210320** =
260 +* Recipe address discontinuous address setting;
261 +* Trim 0 display setting for numeric input;
262 +* Address Mapping continuous writing settings;
263 +* Screensaver function;
264 +* Multi-Link function (not supported by ie and ig series);
265 +* Traditional recipe function is only applicable to the LEVI2PI project that uses the Recipe function;
266 +* Disc Record Chart;
267 +* Lua script weather forecast function interfaces;
268 +* The ie series supports the barcode scanner;
108 108  
109 -**Official Website:**
270 +(% class="wikigeneratedid" id="HDriverProtocol-3" %)
271 +Driver Protocol
110 110  
111 -**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20210320.zip]]**
273 +* Koyo Modbus RTU;
274 +* ASK series;
275 +* Anda inverter;
276 +* Optimize the barcode scanner protocol;
112 112  
113 -**Dropbox:**
278 +== V7.1.117_D20210320 ==
114 114  
115 -**[[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=PIStudio20210320.zip&subfolder_nav_tracking=1]]**
280 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20210320.zip]]
281 +* Dropbox: [[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=PIStudio20210320.zip&subfolder_nav_tracking=1]]
116 116  
117 -== **2.1 Bugs Fixed** ==
283 +(% class="wikigeneratedid" id="HBugsfixed-2" %)
284 +**Bugs fixed**
118 118  
119 -=== **2.1.1 PC Software** ===
286 +(% class="wikigeneratedid" id="HPCSoftware-4" %)
287 +PC Software
120 120  
121 -A) Fix the crash problem of the software;
289 +* Fix the crash problem of the software;
290 +* Renew the wiring diagram and pin definition diagram;
291 +* After the address is annotated, still able to communicate in Lua script;
292 +* Ethernet download optimization;
293 +* The project folder contains special language characters(except Chinese and English), errors in compiling Lua file and project, failed to download the project;
294 +* Use some fonts will cause software crash when compiling the project;
122 122  
123 -B) Renew the wiring diagram and pin definition diagram;
296 +(% class="wikigeneratedid" id="HHMIApplication-4" %)
297 +HMI Application
124 124  
125 -C) After the address is annotated, still able to communicate in Lua script;
299 +* Occasionally occur stuck logo problem after enable the Index of Recipe function;
300 +* B) Frequently screen switching might have a little chance cause stuck problem if there exist many table objects on the screen;
301 +* There is a little chance cause the stuck problem if use the script;
302 +* The stuck problem if use User permission;
303 +* The stuck problem when Data record upload;
304 +* There is a little chance to jump to the test interface after restart;
305 +* After the backlight is off, there is a small chance that the screen will display abnormal;
306 +* Video play cause stuck problem of General series 9150;
307 +* When the HMI just turned on, Recipe Display on the main screen is displayed as NULL;
308 +* Optimize Lua built-in library and file read/write functions;
309 +* The label of the operation value in the Operation record is displayed abnormal;
310 +* The length of channel name for Data record exceeds 32 bytes, will cause failed recording;
311 +* After entering the installment password, restart immediately, would require entering the password again;
126 126  
127 -D) Ethernet download optimization;
313 +(% class="wikigeneratedid" id="HDriverProtocol-4" %)
314 +Driver Protocol
128 128  
129 -E) The project folder contains special language characters(except Chinese and English), errors in compiling Lua file and project, failed to download the project;
316 +* Frequently screen switching and there are many external addresses on the screen, which might have a little chance cause a stuck problem; 
317 +* Ethernet free tags may cause touch problem with no response;
318 +* Ethernet free tags occur error in compiling the project;
319 +* The input/output terminals of communication with MIKOM PLC are abnormal;
320 +* The reading information from scanner will not display if it exceeds 128 characters;
321 +* Failed to communicate with the OMRON NX/NJ PLC communication after power-on the screen and then power on the PLC.
322 +* When HMI+ is just turned on, the Ethernet communication prompts timeout;
323 +* When communicate with Siemens new protocol, will let the HMI stuck on LOGO screen;
130 130  
131 -F) Use some fonts will cause software crash when compiling the project;
325 +(% class="wikigeneratedid" id="HNewfunctions-2" %)
326 +**New functions**
132 132  
133 -=== **2.1.2 HMI Application** ===
328 +(% class="wikigeneratedid" id="HPCSoftware-5" %)
329 +PC Software
134 134  
135 -A) Occasionally occur stuck logo problem after enable the Index of Recipe function;
331 +* New ie series: 3043ie, 3043ieS, 3070ie, 3102ie;
332 +* Industry purpose-designated models: ie series 3070ind, 3102ind, I series 3070ind-n;
333 +* Import and export function for Gallery file ( .blb or .plb format);
136 136  
137 -B) Frequently screen switching might have a little chance cause stuck problem if there exist many table objects on the screen;
335 +(% class="wikigeneratedid" id="HHMIApplication-5" %)
336 +HMI Application
138 138  
139 -C) There is a little chance cause the stuck problem if use the script;
338 +* VNC LAN monitoring function ( require i series and PI+ models with Ethernet port and customized, the -O model in General series still use HMI Monitor System)
339 +* Resource report function to count the total memory used by the current screen;
340 +* Message prompt list (timeout , message , only available for ie series);
341 +* Timer and Trigger function in Lua script (only available for ie series);
342 +* Lua custom object, Lua table drawing, Lua curve drawing (only available for ie series);
343 +* Continuous input function of numeric and character object;
344 +* 4 Macro script functions involving file operations, FileCmpDir(), MyDeleteFile(), WriteWordToFile(), ReadWordFormFile();
345 +* The backstage interface can upgrade PLC program to support 5VPLC program download (only available for 3000i and PI+ series);
140 140  
141 -D) The stuck problem if use User permission;
347 +(% class="wikigeneratedid" id="HDriverProtocol-5" %)
348 +Driver Protocol
142 142  
143 -E) The stuck problem when Data record upload;
350 +* Keyence KV series;
144 144  
145 -F) There is a little chance to jump to the test interface after restart;
352 +== Notification of PI+ ==
146 146  
147 -G) After the backlight is off, there is a small chance that the screen will display abnormal;
354 +* [[Download Link>>url:https://drive.google.com/file/d/1UMb8YGc5lLSfoF_UHD5A4HwE_HKd-Qg7/view?usp=sharing]]
148 148  
149 -H) Video play cause stuck problem of General series 9150;
356 += **2 Levi2PI** =
150 150  
151 -I) When the HMI just turned on, Recipe Display on the main screen is displayed as NULL;
358 +== V4.3.8 ==
152 152  
153 -J) Optimize Lua built-in library and file read/write functions;
360 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Wecon%20LEVI2PI.zip]]
361 +* Dropbox: [[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=Wecon+LEVI2PI.zip&subfolder_nav_tracking=1]]
154 154  
155 -K) The label of the operation value in the Operation record is displayed abnormal;
363 +== V4.5.6(Test Version) ==
156 156  
157 -L) The length of channel name for Data record exceeds 32 bytes, will cause failed recording;
365 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/10Ay8dr7MK6CCpMIKEmKITG3DGipffJsI/view?usp=sharing]]
158 158  
159 -M) After entering the installment password, restart immediately, would require entering the password again;
367 += **3 HMI Monitor System** =
160 160  
161 -=== **2.1.3 Driver Protocol** ===
369 +== VER: 20210317 ==
162 162  
163 -A) Frequently screen switching and there are many external addresses on the screen, which might have a little chance cause a stuck problem; 
371 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/1RA3ui3jTCKtQTCLySjD4Qi7Ut58EYYD1/view?usp=sharing]]
164 164  
165 -B) Ethernet free tags may cause touch problem with no response;
373 += **4 Logo Making Tool** =
166 166  
167 -C) Ethernet free tags occur error in compiling the project;
168 -
169 -D) The input/output terminals of communication with MIKOM PLC are abnormal;
170 -
171 -E) The reading information from scanner will not display if it exceeds 128 characters;
172 -
173 -F) Failed to communicate with the OMRON NX/NJ PLC communication after power-on the screen and then power on the PLC.
174 -
175 -G) When HMI+ is just turned on, the Ethernet communication prompts timeout;
176 -
177 -H) When communicate with Siemens new protocol, will let the HMI stuck on LOGO screen;
178 -
179 -== **2.2 New Functions Added** ==
180 -
181 -=== **2.2.1 PC Software** ===
182 -
183 -A) New ie series: 3043ie, 3043ieS, 3070ie, 3102ie;
184 -
185 -B) Industry purpose-designated models: ie series 3070ind, 3102ind, I series 3070ind-n;
186 -
187 -C) Import and export function for Gallery file ( .blb or .plb format);
188 -
189 -=== **2.2.2 HMI Application** ===
190 -
191 -A) VNC LAN monitoring function ( require i series and PI+ models with Ethernet port and customized, the -O model in General series still use HMI Monitor System)
192 -
193 -B) Resource report function to count the total memory used by the current screen;
194 -
195 -C) Message prompt list (timeout , message , only available for ie series);
196 -
197 -D) Timer and Trigger function in Lua script (only available for ie series);
198 -
199 -E) Lua custom object, Lua table drawing, Lua curve drawing (only available for ie series);
200 -
201 -F) Continuous input function of numeric and character object;
202 -
203 -G) 4 Macro script functions involving file operations, FileCmpDir(), MyDeleteFile(), WriteWordToFile(), ReadWordFormFile();
204 -
205 -H) The backstage interface can upgrade PLC program to support 5VPLC program download (only available for 3000i and PI+ series);
206 -
207 -== **2.2.3 Driver Protocol** ==
208 -
209 -A) Keyence KV series;
210 -
211 -== **2.2.4 Notification of PI+** ==
212 -
213 -**[[Download Link>>url:https://drive.google.com/file/d/1UMb8YGc5lLSfoF_UHD5A4HwE_HKd-Qg7/view?usp=sharing]]**
214 -
215 -= **3 Levi2PI V4.3.8** =
216 -
217 -**Official Website:**
218 -
219 -**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/Wecon%20LEVI2PI.zip]]**
220 -
221 -**Dropbox:**
222 -
223 -**[[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=Wecon+LEVI2PI.zip&subfolder_nav_tracking=1]]**
224 -
225 -= **4 Levi2PI V4.5.6(Test Version)** =
226 -
227 -**Google Drive**
228 -
229 -**[[Download Link>>https://drive.google.com/file/d/10Ay8dr7MK6CCpMIKEmKITG3DGipffJsI/view?usp=sharing]]**
230 -
231 -= **5 HMI Monitor System20210317** =
232 -
233 -**Google Drive:**
234 -
235 -**[[Download Link>>https://drive.google.com/file/d/1RA3ui3jTCKtQTCLySjD4Qi7Ut58EYYD1/view?usp=sharing]]**
236 -
237 -
238 -= **6 Logo Making Tool** =
239 -
240 -**Google Drive:**
241 -
242 -**[[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]**
375 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]
image-20220708184749-1.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.6 KB
Content
image-20220708184750-2.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.6 KB
Content
image-20220708184750-3.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.6 KB
Content
image-20220708184751-4.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.6 KB
Content
image-20220708184751-5.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.6 KB
Content