Changes for page 3 Software
Last modified by Hunter on 2025/11/22 16:31
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. joe1 +XWiki.Hunter - Content
-
... ... @@ -1,5 +1,118 @@ 1 +1. ((( 1 1 = **1 PIStudio** = 3 +))) 4 +1. ((( 5 +== **V10.5.45.25102301(PI9000ig, RL, RH, WP)** == 6 +))) 2 2 8 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_10.5.zip]] 9 + 10 +{{warning}} 11 +This test version software is only available for the following models: PI9000ig series, RL series, RH series, and WP series. For all other models, the released version is recommended as the first priority. 12 +{{/warning}} 13 + 14 +(% class="wikigeneratedid" %) 15 +**Bugs fixed** 16 + 17 +1. Slow response issue with IN series HMI; 18 +1. ((( 19 +Slow response of Alarm record and address monitoring table, and stuck when opening the project 20 +))) 21 + 22 + 23 + 24 +(% class="wikigeneratedid" %) 25 +**New functions** 26 + 27 +(% class="wikigeneratedid" %) 28 +PC Software 29 + 30 + 31 +(% class="wikigeneratedid" %) 32 +HMI Application 33 + 34 +1. NTP time synchronization; 35 +1. New touch calibration interface; 36 +1. Sub screen modal mode; 37 +1. Exclusive operation; 38 +1. Watchdog; 39 +1. New Alarm Record; 40 +1*. New alarm record interface; 41 +1*. Alarm record ascending/descending order; 42 +1*. Alarm record statistics; 43 +1*. Diverse Alarm record styles; 44 +1. Media player; 45 +1. Mouse cursor style; 46 +1. Timeout NC effect; 47 +1. Sub-screen drag-and-drop; 48 +1. Minimum pressing interval time countdown tips UI; 49 +1. Additional options for trigger write addresses in alarm records; 50 +1. UNICODE and GBK display format are added to alarm variables; 51 +1. User permissions can configure the time of auto logout; 52 +1. Text-To-Speech; 53 +1. Voice broadcast; 54 +1. The message prompt module supports 48 languages; 55 +1. Add remote management module in the background; 56 +1. Remote background; 57 +1. Access verification function; 58 +1. IP restriction function; 59 +1. Equipment control function; 60 +1. Access log viewing function; 61 +1. Configure network routing mode, switch mode and WIFI hotspot in the background 62 +1. RH series, 9000ig series DIP switch function 63 +11. Factory reset 64 +11. Touch calibration adaptation; 65 +1. Vertical alignment method for text display; 66 +1. Histogram object; 67 +1. Text tag function; 68 +1. Supports control via special registers to adjust the button size and spacing on the new Alarm record object, new Recipe Record object, and Column Chart; 69 +1. The text for email content, user login (username), user login (description), and log message text (operation records) supports configuration via a string table. 70 +1. Scheduling function; 71 +1. Optimized: Sub-screen pop-up position optimization; 72 +1. RE and RL series support NTP (network time protocol) function; 73 + 74 +(% class="wikigeneratedid" %) 75 +**New drive** 76 + 77 + 78 +1. Winding Machine MODBUS RTU Winder; 79 +1. KEYENCE EtherNet/IP (KV-8000); 80 +1. KEYENCE EtherNet/IP (KV-X310); 81 +1. KEYENCE EtherNet/IP (KV-X520); 82 +1. INOVANCE H5U PLC Ethernet FreeTag (fast) replaces INOVANCE H5U PLC Ethernet FreeTag ; 83 +1. Siemens Ethernet FreeTag (S7 Series); 84 +1. LAICARD RFID Reader; 85 +1. KEYENCE Scanner HR-100B; 86 +1. KEYENCE Scanner HR-100; 87 +1. RONGSHI RFID Reader; 88 +1. KCJ RFID Reader; 89 +1. BACnet_IP; 90 +1. HONEYWELL Scanner 1902-C; 91 +1. Read interval time setting (RwDelay register) for modbus rtu slave. 92 +1. Expanded SD,SM register address range (up to 511) for INVT_IVC1. 93 +1. Leadshine LEISHINE _ SC-C32A4DS ModbusTcp; 94 +1. Leadshine LEISHINE _ SC-C32A4DS ModbusRTU; 95 +1. FANUC protocol; 96 +1. NEWLAND Scanner; 97 +1. NEWLAND Scanner COM; 98 +1. Leadshine LEISHINE _ LC1000 _ Series _ TCP; 99 +1. Leadshine LEISHINE _ LC1000 _ Series _ RTU; 100 +1. ModBus RTU Slave (All Fuction)~-~-RwDelay register for controlling send/receive interval; 101 +1. MITSUBISHI FX5U Ethernet—Bit-in-Word; 102 +1. Expanded SD, SM register range for INVT_IVC1 protocol; 103 +1. New CODESYS V3 protocol-read Unicode strings (WSTRING data type); 104 + 105 +(% class="wikigeneratedid" %) 106 +**New models** 107 + 108 + 109 +1. GB series: GB3041, GB3070, GB3101, GB8041, GB8070-H, GB8101; 110 +1. ig series: PI9102ig, PI9121ig, PI9150ig, PI9151ig; 111 +1. WP series: WP2070, WP2071, WP3070, WP3071; 112 +1. MD series: MD8102; 113 +1. RL series: RL-G, RL-WF; 114 +1. RH series: RH-00, RH-00-4K, RH-AG, RH-G, RH-W, RH-WG, RH-WG-CNC, RH-WG-E, RH-WG-LA, RH-WIFI; 115 + 3 3 == **V9.5.9.25091702** == 4 4 5 5 * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.5.9.25091702.zip]] ... ... @@ -6,12 +6,13 @@ 6 6 7 7 (% class="box errormessage" %) 8 8 ((( 9 -**Notice** 10 -1. The new version can not support general series(PI3000,PI8000,PI9000). Please use the old version (Release Build VER:R05R998_V8.4.114_D24061301) to program the general series. 11 -2. **After the upgrade, only the ig series can use the Lua MQTT library.** 12 -3. Projects opened with the new version cannot be opened with the old version. Please make sure to back up the project. 13 -4. After the upgrade, the supported protocols will change. PI3000ig can not support the third-part Free-tags Protocol.**For details, please refer to: [[Limitation of the Ethernet communication protocol - Wecon>>url:https://docs.we-con.com.cn/bin/view/PIStudio/PLC Protocol/Limitation of the Ethernet communication protocol/]]** 14 -5. Cannot roll back the version after upgrading. 122 +**Notice** 123 + 124 +1. The new version can not support general series(PI3000,PI8000,PI9000). Please use the old version (Release Build VER:R05R998_V8.4.114_D24061301) to program the general series. 125 +1. **After the upgrade, only the ig series can use the Lua MQTT library.** 126 +1. Projects opened with the new version cannot be opened with the old version. Please make sure to back up the project. 127 +1. After the upgrade, the supported protocols will change. PI3000ig can not support the third-part Free-tags Protocol.**For details, please refer to: [[Limitation of the Ethernet communication protocol - Wecon>>url:https://docs.we-con.com.cn/bin/view/PIStudio/PLC Protocol/Limitation of the Ethernet communication protocol/]]** 128 +1. Cannot roll back the version after upgrading. 15 15 ))) 16 16 17 17 **Bugs fixed** ... ... @@ -23,7 +23,7 @@ 23 23 24 24 **New functions** 25 25 26 - **Cloud configuration supports Asian 2.0 servers;**140 +Cloud configuration supports Asian 2.0 servers; 27 27 28 28 == **V9.4.13.25053001** == 29 29