Changes for page 3 Software
Last modified by Jett on 2025/03/13 14:13
Summary
-
Page properties (4 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - 5Software1 +3 Software - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -PIStudio.WebHome 1 +PIStudio.Download.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Mora - Content
-
... ... @@ -1,246 +1,400 @@ 1 -= **PIStudio Release Build VER:R05R998_V8.2.62_D20220625** =1 += **1 PIStudio** = 2 2 3 +== V8.4.66_D23102001 == 3 3 4 -(% class="wikigeneratedid" %) 5 -= **PIStudio Release Build VER:R05R998_V7.2.198_D20211210** = 5 +* Official Website: [[Download Link>>Download Linkhttps://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.66.23102001.zip]] 6 6 7 -(% class="wikigeneratedid" %) 8 -**Official Website:** 7 +**Bugs fixed** 9 9 10 -(% class="wikigeneratedid" %) 11 -**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]]** 9 +PC Software 12 12 13 -**Google Drive:** 11 +1. In Omron free tag protocol, software crash during project compilation after tag import; 12 +1. In Omron free tag protocol, the project cannot be driven in package when compiling; 13 +1. 3102ig Camera Display object cannot be compiled; 14 +1. Error in the length limit of the folder edit box for the image display function of the bitmap object graphical interface; 15 +1. Error in the description of the expiration time for CreateInstallmentPwd tool: Modify from expiration time to next expiration time; 16 +1. Crash when the conversion tool converts the History XY Plot; 17 +1. It prompts wrong address when the conversion tool converts the Bit Alarm Record; 18 +1. The width-height ratio is wrong when the DiscRecord Chart object switches different resolutions; 19 +1. Error in compiling address of OMRON NX Ethernet/IP Protocol; 20 +1. Software crash and abnormal interface update when search address in address list; 21 +1. PI toolkit probably fails to connect for the first time; 22 +1. The data record is incomplete, and the table column width cannot be adjusted when using DataLogTool; 23 +1. Abnormal use of some tag addresses; 24 +1. Modified: Inconsistent color between meter value and scale; 25 +1. Error in tag array correspondence of tag protocol; 26 +1. Abnormal display when configuring the underlying screen; 27 +1. Abnormal compilation of 8070ig for using Camera Control object; 28 +1. Some pictures are lost after compilation; 29 +1. Abnormal display of bitmap of Switch object; 30 +1. Shortcut key configuration will also be deleted after deleting any main screen; 31 +1. HMI graphics status color cannot be changed; 32 +1. Modified: After the text is successfully set in Text Library, the language content is not grayed out when entering the settings again; 14 14 15 - **[[DownloadLink>>https://drive.google.com/file/d/1lRfgoOwAs7lgL4b-ZdVUvE6itHWCpfd5/view?usp=sharing]]**34 +== V8.2.95_D20220928 == 16 16 17 - ==**BugsFixed**==36 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220928.zip]] 18 18 19 -=== **PC Software** === 38 +(% class="wikigeneratedid" id="HBugsfixed" %) 39 +**Bugs fixed** 20 20 21 -A) Optimize the display style of text objects; 41 +(% class="wikigeneratedid" %) 42 +PC Software 22 22 23 -B) Optimize Lua script file size limitation to 512KB; 44 +1. Optimize the function of saving project as; 45 +1. The word alarm configuration cannot be imported after being exported; 46 +1. The problem of abnormal resolution after png image editing and external import;  47 +1. The password of project designer can be input into Chinese; 48 +1. The 8150ig model cannot be configured with camera search function; 49 +1. The probability of recipe setting cannot be saved; 50 +1. When simulating the "WECON" directory of C disk is adjusted to "HMIEmulation" directory; 51 +1. The problem that the position of text parts does not change after setting coordinates; 52 +1. The interface displays an redundant scroll bar when creating a new screen; 53 +1. The download tool only scans one of the network segments when there are multiple ip under the computer network card; 54 +1. The content of data records is abnormal and cannot be imported after being exported; 55 +1. The welcome interface opens the project and incorrectly prompts the project to be occupied; 56 +1. The installation path affects clicking offline simulation to pop up online simulation; 57 +1. The font size of the newly built-in screen 5004 is abnormal when switching to the size of 1920*1080; 58 +1. When the data record is stored in U disk and SD card, the size of the data record is not limited during compilation; 59 +1. The name of the newly created part in the right-click menu bar is consistent with the name in the part list; 60 +1. The problem that when compiling ie series projects, the memory size of the components of the picture exceeds the problem that no error is reported; 61 +1. When the U disk upgrade tool selects an invalid drive letter to generate a file, it does not normally prompt errors; 62 +1. The prompting wrong parameters when opening engineering parameters in the project of repairing vertical screen; 24 24 25 -C) Optimize the import of text library and the limitation to 2000; 64 +(% class="wikigeneratedid" %) 65 +HMI Application 26 26 27 -D) Protocol driver names standardized; 67 +1. Keyboard without "&" the question of symbols; 68 +1. The camera function on HMI V2.0 system will report error messages; 69 +1. The camera picture is still displayed after switching pictures on HMI V2.0 system; 70 +1. The project of Chinese character designer password cannot be simulated; 71 +1. The screenshots of printed parts are invalid when saved to SD card; 72 +1. The project downloaded by Ethernet cannot be uploaded normally; 73 +1. The debugging window moves the left and right scroll bars, and the upper and lower scroll bars will jump to the bottom; 74 +1. The manual APN of 4G setting cannot be saved; 75 +1. The system is upgraded to V2.0, the horizontal and vertical screens are abnormal; 76 +1. PI3043ie can't communicate with plc after upgrading; 77 +1. HMI2.0 background dynamic and static switch does not cache static IP; 78 +1. PI3070ig ftpserver can't access the service; 79 +1. V-BOX can't download PI3070N through download; 80 +1. The starting time will automatically change after the data record query setting interface pops up; 81 +1. The flow component displaying deviation in web pages; 82 +1. The alarm record header of switching language is not switched; 83 +1. The current alarm record will show the problem of historical alarm record; 84 +1. The camera uses power failure to save the address, and the camera state is not initialized after power failure and restart; 85 +1. The camera directly enters the account number, password and device serial number without enabling the search module; 86 +1. PI audio plays with sound and the volume is displayed as 0; 87 +1. When the hot spot name of the connection has single quotation marks, the network cannot recognize the problem; 88 +1. Add background U Disk upgrade updates the network configuration function (downloads the Ethernet parameters in the project parameters synchronously to the HMI 89 +1. The ig series can't use ezviz cloud function when using 4G Internet of Things card to surf the Internet; 90 +1. The screen saver cannot be exited on HMI V2.0 system; 91 +1. The communication is disconnected and cannot be reconnected after ig series VPN penetrates; 92 +1. Optimize the polling speed of VB trigger script; 28 28 29 - E)Fontsizeis opento 512;94 +Drive the updated 30 30 31 - F)Luascriptdebugging windowcanbeconfiguredas enabledornotinProject Settings;96 +1. The abnormal communication caused by recipe reading; 32 32 33 - G) Optimizethe fontdisplayof Runbar;98 +Driver Protocol 34 34 35 - H)Optimizedthe forcedbackup functionofprojectfile, now you can click thecancelbutton to not backup;100 +1. Add Omron (NX/NJ) free label driver; 36 36 37 - I) Optimizedand adjusted the default size of the password keyboard screenof newly-created projects;102 +**New functions** 38 38 39 - J)Wrong display range ofhe History trend chart;104 +PC Software 40 40 41 -K) The font display of Drop-down List on PC is different from the actual screen; 106 +1. The picture compression function in the project parameters; 107 +1. Compatible switching models of PI8150ig (1920*1080 and 1280*720). 108 +1. The template picture with resolution of 1920*1080 of ig. 109 +1. ig series does not check the size limit of data record files. 42 42 43 - L)Softwarecrash caused by deleting the Address Library name;111 +HMI Application 44 44 45 -M) General Series SMS protocol cannot be selected; 113 +1. The rotation function of switch components (only supported by HMI V2.0 system); 114 +1. Automatic rotation of rotation bitmap control and address control hiding function (only supported by HMI V2.0 system); 115 +1. Ftp service function (only supported by HMI V2.0 system); 116 +1. Ezviz cloud camera function (only supported by HMI V2.0 system); 117 +1. Lua curve custom component sliding bar function and draw 8 curves (only supported by HMI V2.0 system); 118 +1. Background language boot configuration (only supported by HMI V2.0 system); 119 +1. The function of modifying the header of data records (only supported by HMI V2.0 system); 120 +1. Historical trend style 6 and style 7 (only supported by HMI V2.0 system); 121 +1. PI8150ig (1920*1080rn) resolution; 46 46 47 -== =**HMIApplication**===123 +== V8.2.62_D20220625 == 48 48 49 -A) Multi-Language display of text fonts; 125 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220625.zip]] 126 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/1kJuuzxjPj5mZmeazhGxrs3lGyMceqmYj/view?usp=sharing]] 50 50 51 -B) Password keyboard input to display the plain text first and then the * sign; 128 +(% class="wikigeneratedid" id="HBugsfixed" %) 129 +**Bugs fixed** 52 52 53 -C) Prompt display of Screen Lock for ie and ig; 131 +(% class="wikigeneratedid" id="HPCSoftware" %) 132 +PC Software 54 54 55 -D) Auto refresh of Data Record; 134 +1. Cloud.xml does not exist in the project file of 8000 series and cannot access cloud; 135 +1. Lua prompting error when double click the project path of General series in Screen Management; 136 +1. The cursor moving into the area of background script will be disappeared; 137 +1. After the Lua script is changed, it is not compiled, and there is no prompt when clicking offline simulation; 138 +1. DLView fails to import excel files; 139 +1. There is an abnormality when creating image files into Udisk; 140 +1. Orientation options missing for Slide switch; 141 +1. COM3 Configuration missing for following models: 3070i-A and 3102i-A; 142 +1. When the download tool downloads the project, it does not prompt when the file does not exist; 143 +1. SD Card option missing for following models: 3070i-A, 3102i-A, 3070i-C, 3102i-C; 144 +1. Some of the same font size, font style is different when the font size is displayed abnormally; 145 +1. Optimize the built-in screen No.1008, add Time and Date objects; 146 +1. Optimize the remote download; 147 +1. Optimize the U disk upgrade function; 148 +1. Prompt when the downloads a file with a long path; 149 +1. The ig series vertical screen option is available now; 56 56 57 -=== **Driver Protocol** === 151 +(% class="wikigeneratedid" id="HHMIApplication" %) 152 +HMI Application 58 58 59 -A) Communication cannot be performed after entering the backstage project; 154 +1. The i series freezes with HSW24 soft reboot; 155 +1. Debugging window cannot be closed on the ig monitoring page; 156 +1. Abnormal record time of ig Data record; 157 +1. The ig series abnormal ethernet communication; 158 +1. The register for network status HSW850 abnormal value; 159 +1. Lua we_bas_getstring script function execution error; 160 +1. The video title with English brackets cannot be played; 161 +1. Touch screen will lead to HMI freezes when keyboard input and cursor is enabled; 162 +1. Logo failed download for PI8150ig (before the firmware version 0313); 163 +1. After PI8000 series remote download PLC program, PLC cannot communicate; 164 +1. PI8000 series and ig series online V-NET but cannot remote control; 165 +1. Background Ethernet static IP configuration is not saved; 166 +1. The ig series WVPN remote pass through fails; 167 +1. Lua timer does not perform timing operations according to the interval; 60 60 61 -B) Stuck screen problem caused by the protocol IEC60870-104 Client; 169 +(% class="wikigeneratedid" id="HDriverProtocol" %) 170 +Driver Protocol 62 62 63 -== **New Functions Added** == 172 +1. PI8000ig and Yudian sensor cannot communicate; 173 +1. Modify the name of the Wecon LX6V protocol, the old version project must be re-selected; 174 +1. The following serial port protocols have intermittent communication timeout issue: Siemens S7-200 smart, modbus, INVT, etc. 175 +1. Taian AP200 C register can not read the value 64 64 65 -=== **PC Software** === 177 +(% class="wikigeneratedid" id="HNewfunctions" %) 178 +**New functions** 66 66 67 -A) New ie series model: 3035ie; 180 +(% class="wikigeneratedid" id="HPCSoftware-1" %) 181 +PC Software 68 68 69 -B) New ig series models: 3070ig, 3102ig; 183 +1. VB script customize naming function; 184 +1. PI Suite toolkit; 185 +1. System upgrade function; 186 +1. PIRecordUpload has added User permission function; 187 +1. Cloud function of 8000 and 9000 series; 70 70 71 -C) License agreement for the software installation setup process; 189 +(% class="wikigeneratedid" id="HHMIApplication-1" %) 190 +HMI Application 72 72 73 - D) ObjectLock/Unlockfunction(Pushpin);192 +The following function is only available for ig series: 74 74 75 -E) Lua Editor to highlight the same content of the selected text; 194 +1. Slider of History trend chart can set the color and transparency; 195 +1. Continuous read and write addresses in Lua script; 196 +1. Built-in Lua extension module; 197 +1. Display network camera on HMI screen for 8150ig; 198 +1. Vertical Display; 199 +1. The priority settings of Cloud connection method from backstage configuration; 200 +1. Lua script supports https protocol now; 201 +1. UDisk Download project prohibit upload function; 202 +1. Lua script luasqlite operation; 203 +1. The following function is only available for i,ie,ig series and HMI+ system: 204 +1. All series remove the restriction of special machine code; 205 +1. Recipe 64-bit floating point number data format; 206 +1. UDisk Pop-Up function; 207 +1. Interconversion between GB2312 and UTF-8 encoding; 208 +1. UDisk download PLC multi-file function; 209 +1. Modifitable datetime prohibited; 210 +1. Color configuration of Line object; 76 76 77 -F) Font style settings of the Runbar and chart type objects; 212 +(% class="wikigeneratedid" id="HDriverProtocol-1" %) 213 +Driver Protocol 78 78 79 -G) Software installation package VC 2017 runtime library; 215 +1. Inovance H3U Ethernet; 216 +1. Rockwell micro850 Ethernet/IP Free Tags; 217 +1. Wecon LX6V Free Tags; 80 80 81 -=== **HMI Application** === 219 +(% class="wikigeneratedid" id="HNewmodels" %) 220 +**New models** 82 82 83 -A) Recipe address discontinuous address setting; 222 +1. The i series: 3070i-A, 3102i-A, 3070i-C, 3102i-C, 3070i-2S, 3102i-2S 223 +1. The ie series: 3043ie-T 224 +1. The ig series: 8150ig 84 84 85 -B) Trim 0 display setting for numeric input; 226 +(% class="box infomessage" %) 227 +((( 228 +✎Note: 86 86 87 -C) Address Mapping continuous writing settings; 230 +* To use the new functions avaiable from new version, the project needs to be downloaded twice; 231 +* After the wifi module (version V1.1) of 3070ig is soft restarted, if the wifi is not recognized from background interface, please repower to recover it; 232 +))) 88 88 89 -D ) Screensaverfunction;234 +== V7.2.198_D20211210 == 90 90 91 -E) Multi-Link function (not supported by ie and ig series); 236 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]] 237 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/1lRfgoOwAs7lgL4b-ZdVUvE6itHWCpfd5/view?usp=sharing]] 92 92 93 -F) Traditional recipe function is only applicable to the LEVI2PI project that uses the Recipe function; 239 +(% class="wikigeneratedid" id="HBugsfixed-1" %) 240 +**Bugs fixed** 94 94 95 -G) Disc Record Chart; 242 +(% class="wikigeneratedid" id="HPCSoftware-2" %) 243 +PC Software 96 96 97 -H) Lua script weather forecast function interfaces; 245 +* Optimize the display style of text objects; 246 +* Optimize Lua script file size limitation to 512KB; 247 +* Optimize the import of text library and the limitation to 2000; 248 +* Protocol driver names standardized; 249 +* Font size is open to 512; 250 +* Lua script debugging window can be configured as enabled or not in Project Settings; 251 +* Optimize the font display of Runbar; 252 +* Optimized the forced backup function of project file, now you can click the cancel button to not backup; 253 +* Optimized and adjusted the default size of the password keyboard screen of newly-created projects; 254 +* Wrong display range of the History trend chart; 255 +* The font display of Drop-down List on PC is different from the actual screen; 256 +* Software crash caused by deleting the Address Library name; 257 +* General Series SMS protocol cannot be selected; 98 98 99 -I) The ie series supports the barcode scanner; 259 +(% class="wikigeneratedid" id="HHMIApplication-2" %) 260 +HMI Application 100 100 101 -=== **Driver Protocol** === 262 +* Multi-Language display of text fonts; 263 +* Password keyboard input to display the plain text first and then the * sign; 264 +* Prompt display of Screen Lock for ie and ig; 265 +* Auto refresh of Data Record; 102 102 103 -A) Koyo Modbus RTU; 267 +(% class="wikigeneratedid" id="HDriverProtocol-2" %) 268 +Driver Protocol 104 104 105 -B) ASK series; 270 +* Communication cannot be performed after entering the backstage project; 271 +* Stuck screen problem caused by the protocol IEC60870-104 Client; 106 106 107 -C) Anda inverter; 273 +(% class="wikigeneratedid" id="HNewfunctions-1" %) 274 +**New functions** 108 108 109 -D) Optimize the barcode scanner protocol; 276 +(% class="wikigeneratedid" id="HPCSoftware-3" %) 277 +PC Software 110 110 111 -= **PIStudio Release Build VER:R05R998_V7.1.117_D20210320** = 279 +* New ie series model: 3035ie; 280 +* New ig series models: 3070ig, 3102ig; 281 +* License agreement for the software installation setup process; 282 +* Object Lock/Unlock function (Pushpin); 283 +* Lua Editor to highlight the same content of the selected text; 284 +* Font style settings of the Runbar and chart type objects; 285 +* Software installation package VC 2017 runtime library; 112 112 113 -**Official Website:** 287 +(% class="wikigeneratedid" id="HHMIApplication-3" %) 288 +HMI Application 114 114 115 -**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20210320.zip]]** 290 +* Recipe address discontinuous address setting; 291 +* Trim 0 display setting for numeric input; 292 +* Address Mapping continuous writing settings; 293 +* Screensaver function; 294 +* Multi-Link function (not supported by ie and ig series); 295 +* Traditional recipe function is only applicable to the LEVI2PI project that uses the Recipe function; 296 +* Disc Record Chart; 297 +* Lua script weather forecast function interfaces; 298 +* The ie series supports the barcode scanner; 116 116 117 -**Dropbox:** 300 +(% class="wikigeneratedid" id="HDriverProtocol-3" %) 301 +Driver Protocol 118 118 119 -**[[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=PIStudio20210320.zip&subfolder_nav_tracking=1]]** 303 +* Koyo Modbus RTU; 304 +* ASK series; 305 +* Anda inverter; 306 +* Optimize the barcode scanner protocol; 120 120 121 -== **BugsFixed**==308 +== V7.1.117_D20210320 == 122 122 123 -=== **PC Software** === 310 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20210320.zip]] 311 +* Dropbox: [[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=PIStudio20210320.zip&subfolder_nav_tracking=1]] 124 124 125 -A) Fix the crash problem of the software; 313 +(% class="wikigeneratedid" id="HBugsfixed-2" %) 314 +**Bugs fixed** 126 126 127 -B) Renew the wiring diagram and pin definition diagram; 316 +(% class="wikigeneratedid" id="HPCSoftware-4" %) 317 +PC Software 128 128 129 -C) After the address is annotated, still able to communicate in Lua script; 319 +* Fix the crash problem of the software; 320 +* Renew the wiring diagram and pin definition diagram; 321 +* After the address is annotated, still able to communicate in Lua script; 322 +* Ethernet download optimization; 323 +* The project folder contains special language characters(except Chinese and English), errors in compiling Lua file and project, failed to download the project; 324 +* Use some fonts will cause software crash when compiling the project; 130 130 131 -D) Ethernet download optimization; 326 +(% class="wikigeneratedid" id="HHMIApplication-4" %) 327 +HMI Application 132 132 133 -E) The project folder contains special language characters(except Chinese and English), errors in compiling Lua file and project, failed to download the project; 329 +* Occasionally occur stuck logo problem after enable the Index of Recipe function; 330 +* B) Frequently screen switching might have a little chance cause stuck problem if there exist many table objects on the screen; 331 +* There is a little chance cause the stuck problem if use the script; 332 +* The stuck problem if use User permission; 333 +* The stuck problem when Data record upload; 334 +* There is a little chance to jump to the test interface after restart; 335 +* After the backlight is off, there is a small chance that the screen will display abnormal; 336 +* Video play cause stuck problem of General series 9150; 337 +* When the HMI just turned on, Recipe Display on the main screen is displayed as NULL; 338 +* Optimize Lua built-in library and file read/write functions; 339 +* The label of the operation value in the Operation record is displayed abnormal; 340 +* The length of channel name for Data record exceeds 32 bytes, will cause failed recording; 341 +* After entering the installment password, restart immediately, would require entering the password again; 134 134 135 -F) Use some fonts will cause software crash when compiling the project; 343 +(% class="wikigeneratedid" id="HDriverProtocol-4" %) 344 +Driver Protocol 136 136 137 -=== **HMI Application** === 346 +* Frequently screen switching and there are many external addresses on the screen, which might have a little chance cause a stuck problem; 347 +* Ethernet free tags may cause touch problem with no response; 348 +* Ethernet free tags occur error in compiling the project; 349 +* The input/output terminals of communication with MIKOM PLC are abnormal; 350 +* The reading information from scanner will not display if it exceeds 128 characters; 351 +* Failed to communicate with the OMRON NX/NJ PLC communication after power-on the screen and then power on the PLC. 352 +* When HMI+ is just turned on, the Ethernet communication prompts timeout; 353 +* When communicate with Siemens new protocol, will let the HMI stuck on LOGO screen; 138 138 139 -A) Occasionally occur stuck logo problem after enable the Index of Recipe function; 355 +(% class="wikigeneratedid" id="HNewfunctions-2" %) 356 +**New functions** 140 140 141 -B) Frequently screen switching might have a little chance cause stuck problem if there exist many table objects on the screen; 358 +(% class="wikigeneratedid" id="HPCSoftware-5" %) 359 +PC Software 142 142 143 -C) There is a little chance cause the stuck problem if use the script; 361 +* New ie series: 3043ie, 3043ieS, 3070ie, 3102ie; 362 +* Industry purpose-designated models: ie series 3070ind, 3102ind, I series 3070ind-n; 363 +* Import and export function for Gallery file ( .blb or .plb format); 144 144 145 -D) The stuck problem if use User permission; 365 +(% class="wikigeneratedid" id="HHMIApplication-5" %) 366 +HMI Application 146 146 147 -E) The stuck problem when Data record upload; 368 +* VNC LAN monitoring function ( require i series and PI+ models with Ethernet port and customized, the -O model in General series still use HMI Monitor System) 369 +* Resource report function to count the total memory used by the current screen; 370 +* Message prompt list (timeout , message , only available for ie series); 371 +* Timer and Trigger function in Lua script (only available for ie series); 372 +* Lua custom object, Lua table drawing, Lua curve drawing (only available for ie series); 373 +* Continuous input function of numeric and character object; 374 +* 4 Macro script functions involving file operations, FileCmpDir(), MyDeleteFile(), WriteWordToFile(), ReadWordFormFile(); 375 +* The backstage interface can upgrade PLC program to support 5VPLC program download (only available for 3000i and PI+ series); 148 148 149 -F) There is a little chance to jump to the test interface after restart; 377 +(% class="wikigeneratedid" id="HDriverProtocol-5" %) 378 +Driver Protocol 150 150 151 - G) Afterthebacklight is off, there is a small chancethatthescreen will display abnormal;380 +* Keyence KV series; 152 152 153 - H) Videoplaycause stuck problemofGeneralseries 9150;382 +== Notification of PI+ == 154 154 155 - I)Whenthe HMI justurnedon, Recipelay on the main screenis displayed as NULL;384 +* [[Download Link>>url:https://drive.google.com/file/d/1UMb8YGc5lLSfoF_UHD5A4HwE_HKd-Qg7/view?usp=sharing]] 156 156 157 - J) OptimizeLuabuilt-in library and fileread/writefunctions;386 += **2 Levi2PI** = 158 158 159 - K)Thelabel of the operation value in the Operation record is displayed abnormal;388 +== V4.5.8 == 160 160 161 - L)The lengthof channel namefor Data record exceeds 32 bytes,will causefailedrecording;390 +* [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Levi2PI.zip]] 162 162 163 - M)Afterenteringthe installment password,restart immediately,would require entering the password again;392 += **3 HMI Monitor System** = 164 164 165 -== =**DriverProtocol**===394 +== VER: 20210317 == 166 166 167 - A) Frequentlyscreen switchingand therearemany externaldressesonthescreen, whichmight have alittlechance cause a stuckproblem;396 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/1RA3ui3jTCKtQTCLySjD4Qi7Ut58EYYD1/view?usp=sharing]] 168 168 169 - B) Ethernetfreetagsmaycause touch problemwith no response;398 += **4 Logo Making Tool** = 170 170 171 -C) Ethernet free tags occur error in compiling the project; 172 - 173 -D) The input/output terminals of communication with MIKOM PLC are abnormal; 174 - 175 -E) The reading information from scanner will not display if it exceeds 128 characters; 176 - 177 -F) Failed to communicate with the OMRON NX/NJ PLC communication after power-on the screen and then power on the PLC. 178 - 179 -G) When HMI+ is just turned on, the Ethernet communication prompts timeout; 180 - 181 -H) When communicate with Siemens new protocol, will let the HMI stuck on LOGO screen; 182 - 183 -== **New Functions Added** == 184 - 185 -=== **PC Software** === 186 - 187 -A) New ie series: 3043ie, 3043ieS, 3070ie, 3102ie; 188 - 189 -B) Industry purpose-designated models: ie series 3070ind, 3102ind, I series 3070ind-n; 190 - 191 -C) Import and export function for Gallery file ( .blb or .plb format); 192 - 193 -=== **HMI Application** === 194 - 195 -A) VNC LAN monitoring function ( require i series and PI+ models with Ethernet port and customized, the -O model in General series still use HMI Monitor System) 196 - 197 -B) Resource report function to count the total memory used by the current screen; 198 - 199 -C) Message prompt list (timeout , message , only available for ie series); 200 - 201 -D) Timer and Trigger function in Lua script (only available for ie series); 202 - 203 -E) Lua custom object, Lua table drawing, Lua curve drawing (only available for ie series); 204 - 205 -F) Continuous input function of numeric and character object; 206 - 207 -G) 4 Macro script functions involving file operations, FileCmpDir(), MyDeleteFile(), WriteWordToFile(), ReadWordFormFile(); 208 - 209 -H) The backstage interface can upgrade PLC program to support 5VPLC program download (only available for 3000i and PI+ series); 210 - 211 -== **Driver Protocol** == 212 - 213 -A) Keyence KV series; 214 - 215 -== **Notification of PI+** == 216 - 217 -**[[Download Link>>url:https://drive.google.com/file/d/1UMb8YGc5lLSfoF_UHD5A4HwE_HKd-Qg7/view?usp=sharing]]** 218 - 219 -= **Levi2PI V4.3.8** = 220 - 221 -**Official Website:** 222 - 223 -**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/Wecon%20LEVI2PI.zip]]** 224 - 225 -**Dropbox:** 226 - 227 -**[[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=Wecon+LEVI2PI.zip&subfolder_nav_tracking=1]]** 228 - 229 -= **Levi2PI V4.5.6(Test Version)** = 230 - 231 -**Google Drive** 232 - 233 -**[[Download Link>>https://drive.google.com/file/d/10Ay8dr7MK6CCpMIKEmKITG3DGipffJsI/view?usp=sharing]]** 234 - 235 -= **HMI Monitor System20210317** = 236 - 237 -**Google Drive:** 238 - 239 -**[[Download Link>>https://drive.google.com/file/d/1RA3ui3jTCKtQTCLySjD4Qi7Ut58EYYD1/view?usp=sharing]]** 240 - 241 - 242 -= **6 Logo Making Tool** = 243 - 244 -**Google Drive:** 245 - 246 -**[[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]** 400 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]
- image-20220708184749-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +8.6 KB - Content
- image-20220708184750-2.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +8.6 KB - Content
- image-20220708184750-3.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +8.6 KB - Content
- image-20220708184751-4.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +8.6 KB - Content
- image-20220708184751-5.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +8.6 KB - Content