Changes for page 3 Software

Last modified by Devin Chen on 2025/04/23 09:14

From version 5.1
edited by Hunter
on 2022/07/08 18:32
Change comment: There is no comment for this version
To version 16.2
edited by Mora Zhou
on 2023/10/27 09:31
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -5 Software
1 +3 Software
Parent
... ... @@ -1,1 +1,1 @@
1 -PIStudio.WebHome
1 +PIStudio.Download.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.Mora
Content
... ... @@ -1,246 +1,454 @@
1 -= **PIStudio Release Build VER:R05R998_V8.2.62_D20220625** =
1 += **1 PIStudio** =
2 2  
3 +== V8.4.66_D23102001 ==
3 3  
4 -(% class="wikigeneratedid" %)
5 -= **PIStudio Release Build VER:R05R998_V7.2.198_D20211210** =
5 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.66.23102001.zip]]
6 6  
7 -(% class="wikigeneratedid" %)
8 -**Official Website:**
7 +**Bugs fixed**
9 9  
10 -(% class="wikigeneratedid" %)
11 -**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]]**
9 +PC Software
12 12  
13 -**Google Drive:**
11 +1. In Omron free tag protocol, software crash during project compilation after tag import;
12 +1. In Omron free tag protocol, the project cannot be driven in package when compiling;
13 +1. 3102ig Camera Display object cannot be compiled;
14 +1. Error in the length limit of the folder edit box for the image display function of the bitmap object graphical interface;
15 +1. Error in the description of the expiration time for CreateInstallmentPwd tool: Modify from expiration time to next expiration time;
16 +1. Crash when the conversion tool converts the History XY Plot;
17 +1. It prompts wrong address when the conversion tool converts the Bit Alarm Record;
18 +1. The width-height ratio is wrong when the DiscRecord Chart object switches different resolutions;
19 +1. Error in compiling address of OMRON NX Ethernet/IP Protocol;
20 +1. Software crash and abnormal interface update when search address in address list;
21 +1. PI toolkit probably fails to connect for the first time;
22 +1. The data record is incomplete, and the table column width cannot be adjusted when using DataLogTool;
23 +1. Abnormal use of some tag addresses;
24 +1. Modified: Inconsistent color between meter value and scale;
25 +1. Error in tag array correspondence of tag protocol;
26 +1. Abnormal display when configuring the underlying screen;
27 +1. Abnormal compilation of 8070ig for using Camera Control object;
28 +1. Some pictures are lost after compilation;
29 +1. Abnormal display of bitmap of Switch object;
30 +1. Shortcut key configuration will also be deleted after deleting any main screen;
31 +1. HMI graphics status color cannot be changed;
32 +1. Modified: After the text is successfully set in Text Library, the language content is not grayed out when entering the settings again;
33 +1. (((
34 +Use “Save as” once, it can open the screen file normally. But use “Save as” again to rename it with the same name, and then the folder will be empty.
35 +)))
36 +1. (((
37 +There is no limit to the size of Custom object;
38 +)))
39 +1. (((
40 +Sub-screen jumps to the next/previous screen (Without common screen), and right-click to switch to the target screen which is not grayed out;
41 +)))
42 +1. (((
43 +HMI crash caused by abnormal data modification of objects;
44 +)))
45 +1. (((
46 +“More" without Spanish translation in TLS/SSL in MQTT;
47 +)))
48 +1. (((
49 +Translation of some objects in right-click is different from that of object bar;
50 +)))
51 +1. (((
52 +After importing HMI project pictures, offline simulation does not display the imported pictures;
53 +)))
54 +1. (((
55 +After modifying the function switch, it will cause communication failure;
56 +)))
57 +1. (((
58 +Download prompt garbled in Win7;
59 +)))
60 +1. (((
61 +The wiring diagram of 8043ig and 3043ig communication is inconsistent with the actual situation;
62 +)))
63 +1. (((
64 +Neutral project simulation crash and download will be stuck and cannot click;
65 +)))
66 +1. (((
67 +Draw objects exceeds boundaries after modifying coordinates to a prompted maximum value;
68 +)))
69 +1. (((
70 + Unable to use lua object directly when not enabling Lua Script;
71 +)))
72 +1. (((
73 +The error prompt of communication port configuration, namely there is spare %s;
74 +)))
75 +1. (((
76 +Language selection of data recording channel does not save;
77 +)))
78 +1. (((
79 +The project file is deleted at compile caused by setting a special path for “Save as”;
80 +)))
81 +1. (((
82 +The preview of Table object does not follow the modification of the number of rows and columns to change;
83 +)))
84 +1. (((
85 +Modifying the coordinates and sizes of Arc object through parameters will cause the inconsistency between graphics and actual situation;
86 +)))
14 14  
15 -**[[Download Link>>https://drive.google.com/file/d/1lRfgoOwAs7lgL4b-ZdVUvE6itHWCpfd5/view?usp=sharing]]**
88 +== V8.2.95_D20220928 ==
16 16  
17 -== **Bugs Fixed** ==
90 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220928.zip]]
18 18  
19 -=== **PC Software** ===
92 +(% class="wikigeneratedid" id="HBugsfixed" %)
93 +**Bugs fixed**
20 20  
21 -A) Optimize the display style of text objects;
95 +(% class="wikigeneratedid" %)
96 +PC Software
22 22  
23 -B) Optimize Lua script file size limitation to 512KB;
98 +1. Optimize the function of saving project as;
99 +1. The word alarm configuration cannot be imported after being exported;
100 +1. The problem of abnormal resolution after png image editing and external import; 
101 +1. The password of project designer can be input into Chinese;
102 +1. The 8150ig model cannot be configured with camera search function;
103 +1. The probability of recipe setting cannot be saved;
104 +1. When simulating the "WECON" directory of C disk is adjusted to "HMIEmulation" directory;
105 +1. The problem that the position of text parts does not change after setting coordinates;
106 +1. The interface displays an redundant scroll bar when creating a new screen;
107 +1. The download tool only scans one of the network segments when there are multiple ip under the computer network card;
108 +1. The content of data records is abnormal and cannot be imported after being exported;
109 +1. The welcome interface opens the project and incorrectly prompts the project to be occupied;
110 +1. The installation path affects clicking offline simulation to pop up online simulation;
111 +1. The font size of the newly built-in screen 5004 is abnormal when switching to the size of 1920*1080;
112 +1. When the data record is stored in U disk and SD card, the size of the data record is not limited during compilation;
113 +1. The name of the newly created part in the right-click menu bar is consistent with the name in the part list;
114 +1. The problem that when compiling ie series projects, the memory size of the components of the picture exceeds the problem that no error is reported;
115 +1. When the U disk upgrade tool selects an invalid drive letter to generate a file, it does not normally prompt errors;
116 +1. The prompting wrong parameters when opening engineering parameters in the project of repairing vertical screen;
24 24  
25 -C) Optimize the import of text library and the limitation to 2000;
118 +(% class="wikigeneratedid" %)
119 +HMI Application
26 26  
27 -D) Protocol driver names standardized;
121 +1. Keyboard without "&" the question of symbols;
122 +1. The camera function on HMI V2.0 system will report error messages;
123 +1. The camera picture is still displayed after switching pictures on HMI V2.0 system;
124 +1. The project of Chinese character designer password cannot be simulated;
125 +1. The screenshots of printed parts are invalid when saved to SD card;
126 +1. The project downloaded by Ethernet cannot be uploaded normally;
127 +1. The debugging window moves the left and right scroll bars, and the upper and lower scroll bars will jump to the bottom;
128 +1. The manual APN of 4G setting cannot be saved;
129 +1. The system is upgraded to V2.0, the horizontal and vertical screens are abnormal;
130 +1. PI3043ie can't communicate with plc after upgrading;
131 +1. HMI2.0 background dynamic and static switch does not cache static IP;
132 +1. PI3070ig ftpserver can't access the service;
133 +1. V-BOX can't download PI3070N through download;
134 +1. The starting time will automatically change after the data record query setting interface pops up;
135 +1. The flow component displaying deviation in web pages;
136 +1. The alarm record header of switching language is not switched;
137 +1. The current alarm record will show the problem of historical alarm record;
138 +1. The camera uses power failure to save the address, and the camera state is not initialized after power failure and restart;
139 +1. The camera directly enters the account number, password and device serial number without enabling the search module;
140 +1. PI audio plays with sound and the volume is displayed as 0;
141 +1. When the hot spot name of the connection has single quotation marks, the network cannot recognize the problem;
142 +1. Add background U Disk upgrade updates the network configuration function (downloads the Ethernet parameters in the project parameters synchronously to the HMI
143 +1. The ig series can't use ezviz cloud function when using 4G Internet of Things card to surf the Internet;
144 +1. The screen saver cannot be exited on HMI V2.0 system;
145 +1. The communication is disconnected and cannot be reconnected after ig series VPN penetrates;
146 +1. Optimize the polling speed of VB trigger script;
28 28  
29 -E) Font size is open to 512;
148 +Drive the updated
30 30  
31 -F) Lua script debugging window can be configured as enabled or not in Project Settings;
150 +1. The abnormal communication caused by recipe reading;
32 32  
33 -G) Optimize the font display of Runbar;
152 +Driver Protocol
34 34  
35 -H) Optimized the forced backup function of project file, now you can click the cancel button to not backup;
154 +1. Add Omron (NX/NJ) free label driver;
36 36  
37 -I) Optimized and adjusted the default size of the password keyboard screen of newly-created projects;
156 +**New functions**
38 38  
39 -J) Wrong display range of the History trend chart;
158 +PC Software
40 40  
41 -K) The font display of Drop-down List on PC is different from the actual screen;
160 +1. The picture compression function in the project parameters;
161 +1. Compatible switching models of PI8150ig (1920*1080 and 1280*720).
162 +1. The template picture with resolution of 1920*1080 of ig.
163 +1. ig series does not check the size limit of data record files.
42 42  
43 -L) Software crash caused by deleting the Address Library name;
165 +HMI Application
44 44  
45 -M) General Series SMS protocol cannot be selected;
167 +1. The rotation function of switch components (only supported by HMI V2.0 system);
168 +1. Automatic rotation of rotation bitmap control and address control hiding function (only supported by HMI V2.0 system);
169 +1. Ftp service function (only supported by HMI V2.0 system);
170 +1. Ezviz cloud camera function (only supported by HMI V2.0 system);
171 +1. Lua curve custom component sliding bar function and draw 8 curves (only supported by HMI V2.0 system);
172 +1. Background language boot configuration (only supported by HMI V2.0 system);
173 +1. The function of modifying the header of data records (only supported by HMI V2.0 system);
174 +1. Historical trend style 6 and style 7 (only supported by HMI V2.0 system);
175 +1. PI8150ig (1920*1080rn) resolution;
46 46  
47 -=== **HMI Application** ===
177 +== V8.2.62_D20220625 ==
48 48  
49 -A) Multi-Language display of text fonts;
179 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220625.zip]]
180 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/1kJuuzxjPj5mZmeazhGxrs3lGyMceqmYj/view?usp=sharing]]
50 50  
51 -B) Password keyboard input to display the plain text first and then the * sign;
182 +(% class="wikigeneratedid" id="HBugsfixed" %)
183 +**Bugs fixed**
52 52  
53 -C) Prompt display of Screen Lock for ie and ig;
185 +(% class="wikigeneratedid" id="HPCSoftware" %)
186 +PC Software
54 54  
55 -D) Auto refresh of Data Record;
188 +1. Cloud.xml does not exist in the project file of 8000 series and cannot access cloud;
189 +1. Lua prompting error when double click the project path of General series in Screen Management;
190 +1. The cursor moving into the area of background script will be disappeared;
191 +1. After the Lua script is changed, it is not compiled, and there is no prompt when clicking offline simulation;
192 +1. DLView fails to import excel files;
193 +1. There is an abnormality when creating image files into Udisk;
194 +1. Orientation options missing for Slide switch;
195 +1. COM3 Configuration missing for following models: 3070i-A and 3102i-A;
196 +1. When the download tool downloads the project, it does not prompt when the file does not exist;
197 +1. SD Card option missing for following models: 3070i-A, 3102i-A, 3070i-C, 3102i-C;
198 +1. Some of the same font size, font style is different when the font size is displayed abnormally;
199 +1. Optimize the built-in screen No.1008, add Time and Date objects;
200 +1. Optimize the remote download;
201 +1. Optimize the U disk upgrade function;
202 +1. Prompt when the downloads a file with a long path;
203 +1. The ig series vertical screen option is available now;
56 56  
57 -=== **Driver Protocol** ===
205 +(% class="wikigeneratedid" id="HHMIApplication" %)
206 +HMI Application
58 58  
59 -A) Communication cannot be performed after entering the backstage project;
208 +1. The i series freezes with HSW24 soft reboot;
209 +1. Debugging window cannot be closed on the ig monitoring page;
210 +1. Abnormal record time of ig Data record;
211 +1. The ig series abnormal ethernet communication;
212 +1. The register for network status HSW850 abnormal value;
213 +1. Lua we_bas_getstring script function execution error;
214 +1. The video title with English brackets cannot be played;
215 +1. Touch screen will lead to HMI freezes when keyboard input and cursor is enabled;
216 +1. Logo failed download for PI8150ig (before the firmware version 0313);
217 +1. After PI8000 series remote download PLC program, PLC cannot communicate;
218 +1. PI8000 series and ig series online V-NET but cannot remote control;
219 +1. Background Ethernet static IP configuration is not saved;
220 +1. The ig series WVPN remote pass through fails;
221 +1. Lua timer does not perform timing operations according to the interval;
60 60  
61 -B) Stuck screen problem caused by the protocol IEC60870-104 Client;
223 +(% class="wikigeneratedid" id="HDriverProtocol" %)
224 +Driver Protocol
62 62  
63 -== **New Functions Added** ==
226 +1. PI8000ig and Yudian sensor cannot communicate;
227 +1. Modify the name of the Wecon LX6V protocol, the old version project must be re-selected;
228 +1. The following serial port protocols have intermittent communication timeout issue: Siemens S7-200 smart, modbus, INVT, etc.
229 +1. Taian AP200 C register can not read the value
64 64  
65 -=== **PC Software** ===
231 +(% class="wikigeneratedid" id="HNewfunctions" %)
232 +**New functions**
66 66  
67 -A) New ie series model: 3035ie;
234 +(% class="wikigeneratedid" id="HPCSoftware-1" %)
235 +PC Software
68 68  
69 -B) New ig series models: 3070ig, 3102ig;
237 +1. VB script customize naming function;
238 +1. PI Suite toolkit;
239 +1. System upgrade function;
240 +1. PIRecordUpload has added User permission function;
241 +1. Cloud function of 8000 and 9000 series;
70 70  
71 -C) License agreement for the software installation setup process;
243 +(% class="wikigeneratedid" id="HHMIApplication-1" %)
244 +HMI Application
72 72  
73 -D) Object Lock/Unlock function (Pushpin);
246 +The following function is only available for ig series:
74 74  
75 -E) Lua Editor to highlight the same content of the selected text;
248 +1. Slider of History trend chart can set the color and transparency;
249 +1. Continuous read and write addresses in Lua script;
250 +1. Built-in Lua extension module;
251 +1. Display network camera on HMI screen for 8150ig;
252 +1. Vertical Display;
253 +1. The priority settings of Cloud connection method from backstage configuration;
254 +1. Lua script supports https protocol now;
255 +1. UDisk Download project prohibit upload function;
256 +1. Lua script luasqlite operation;
257 +1. The following function is only available for i,ie,ig series and HMI+ system:
258 +1. All series remove the restriction of special machine code;
259 +1. Recipe 64-bit floating point number data format;
260 +1. UDisk Pop-Up function;
261 +1. Interconversion between GB2312 and UTF-8 encoding;
262 +1. UDisk download PLC multi-file function;
263 +1. Modifitable datetime prohibited;
264 +1. Color configuration of Line object;
76 76  
77 -F) Font style settings of the Runbar and chart type objects;
266 +(% class="wikigeneratedid" id="HDriverProtocol-1" %)
267 +Driver Protocol
78 78  
79 -G) Software installation package VC 2017 runtime library;
269 +1. Inovance H3U Ethernet;
270 +1. Rockwell micro850 Ethernet/IP Free Tags;
271 +1. Wecon LX6V Free Tags;
80 80  
81 -=== **HMI Application** ===
273 +(% class="wikigeneratedid" id="HNewmodels" %)
274 +**New models**
82 82  
83 -A) Recipe address discontinuous address setting;
276 +1. The i series: 3070i-A, 3102i-A, 3070i-C, 3102i-C, 3070i-2S, 3102i-2S
277 +1. The ie series: 3043ie-T
278 +1. The ig series: 8150ig
84 84  
85 -B) Trim 0 display setting for numeric input;
280 +(% class="box infomessage" %)
281 +(((
282 +✎Note:
86 86  
87 -C) Address Mapping continuous writing settings;
284 +* To use the new functions avaiable from new version, the project needs to be downloaded twice;
285 +* After the wifi module (version V1.1) of 3070ig is soft restarted, if the wifi is not recognized from background interface, please repower to recover it;
286 +)))
88 88  
89 -D) Screensaver function;
288 +== V7.2.198_D20211210 ==
90 90  
91 -E) Multi-Link function (not supported by ie and ig series);
290 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]]
291 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/1lRfgoOwAs7lgL4b-ZdVUvE6itHWCpfd5/view?usp=sharing]]
92 92  
93 -F) Traditional recipe function is only applicable to the LEVI2PI project that uses the Recipe function;
293 +(% class="wikigeneratedid" id="HBugsfixed-1" %)
294 +**Bugs fixed**
94 94  
95 -G) Disc Record Chart;
296 +(% class="wikigeneratedid" id="HPCSoftware-2" %)
297 +PC Software
96 96  
97 -H) Lua script weather forecast function interfaces;
299 +* Optimize the display style of text objects;
300 +* Optimize Lua script file size limitation to 512KB;
301 +* Optimize the import of text library and the limitation to 2000;
302 +* Protocol driver names standardized;
303 +* Font size is open to 512;
304 +* Lua script debugging window can be configured as enabled or not in Project Settings;
305 +* Optimize the font display of Runbar;
306 +* Optimized the forced backup function of project file, now you can click the cancel button to not backup;
307 +* Optimized and adjusted the default size of the password keyboard screen of newly-created projects;
308 +* Wrong display range of the History trend chart;
309 +* The font display of Drop-down List on PC is different from the actual screen;
310 +* Software crash caused by deleting the Address Library name;
311 +* General Series SMS protocol cannot be selected;
98 98  
99 -I) The ie series supports the barcode scanner;
313 +(% class="wikigeneratedid" id="HHMIApplication-2" %)
314 +HMI Application
100 100  
101 -=== **Driver Protocol** ===
316 +* Multi-Language display of text fonts;
317 +* Password keyboard input to display the plain text first and then the * sign;
318 +* Prompt display of Screen Lock for ie and ig;
319 +* Auto refresh of Data Record;
102 102  
103 -A) Koyo Modbus RTU;
321 +(% class="wikigeneratedid" id="HDriverProtocol-2" %)
322 +Driver Protocol
104 104  
105 -B) ASK series;
324 +* Communication cannot be performed after entering the backstage project;
325 +* Stuck screen problem caused by the protocol IEC60870-104 Client;
106 106  
107 -C) Anda inverter;
327 +(% class="wikigeneratedid" id="HNewfunctions-1" %)
328 +**New functions**
108 108  
109 -D) Optimize the barcode scanner protocol;
330 +(% class="wikigeneratedid" id="HPCSoftware-3" %)
331 +PC Software
110 110  
111 -= **PIStudio Release Build VER:R05R998_V7.1.117_D20210320** =
333 +* New ie series model: 3035ie;
334 +* New ig series models: 3070ig, 3102ig;
335 +* License agreement for the software installation setup process;
336 +* Object Lock/Unlock function (Pushpin);
337 +* Lua Editor to highlight the same content of the selected text;
338 +* Font style settings of the Runbar and chart type objects;
339 +* Software installation package VC 2017 runtime library;
112 112  
113 -**Official Website:**
341 +(% class="wikigeneratedid" id="HHMIApplication-3" %)
342 +HMI Application
114 114  
115 -**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20210320.zip]]**
344 +* Recipe address discontinuous address setting;
345 +* Trim 0 display setting for numeric input;
346 +* Address Mapping continuous writing settings;
347 +* Screensaver function;
348 +* Multi-Link function (not supported by ie and ig series);
349 +* Traditional recipe function is only applicable to the LEVI2PI project that uses the Recipe function;
350 +* Disc Record Chart;
351 +* Lua script weather forecast function interfaces;
352 +* The ie series supports the barcode scanner;
116 116  
117 -**Dropbox:**
354 +(% class="wikigeneratedid" id="HDriverProtocol-3" %)
355 +Driver Protocol
118 118  
119 -**[[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=PIStudio20210320.zip&subfolder_nav_tracking=1]]**
357 +* Koyo Modbus RTU;
358 +* ASK series;
359 +* Anda inverter;
360 +* Optimize the barcode scanner protocol;
120 120  
121 -== **Bugs Fixed** ==
362 +== V7.1.117_D20210320 ==
122 122  
123 -=== **PC Software** ===
364 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20210320.zip]]
365 +* Dropbox: [[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=PIStudio20210320.zip&subfolder_nav_tracking=1]]
124 124  
125 -A) Fix the crash problem of the software;
367 +(% class="wikigeneratedid" id="HBugsfixed-2" %)
368 +**Bugs fixed**
126 126  
127 -B) Renew the wiring diagram and pin definition diagram;
370 +(% class="wikigeneratedid" id="HPCSoftware-4" %)
371 +PC Software
128 128  
129 -C) After the address is annotated, still able to communicate in Lua script;
373 +* Fix the crash problem of the software;
374 +* Renew the wiring diagram and pin definition diagram;
375 +* After the address is annotated, still able to communicate in Lua script;
376 +* Ethernet download optimization;
377 +* The project folder contains special language characters(except Chinese and English), errors in compiling Lua file and project, failed to download the project;
378 +* Use some fonts will cause software crash when compiling the project;
130 130  
131 -D) Ethernet download optimization;
380 +(% class="wikigeneratedid" id="HHMIApplication-4" %)
381 +HMI Application
132 132  
133 -E) The project folder contains special language characters(except Chinese and English), errors in compiling Lua file and project, failed to download the project;
383 +* Occasionally occur stuck logo problem after enable the Index of Recipe function;
384 +* B) Frequently screen switching might have a little chance cause stuck problem if there exist many table objects on the screen;
385 +* There is a little chance cause the stuck problem if use the script;
386 +* The stuck problem if use User permission;
387 +* The stuck problem when Data record upload;
388 +* There is a little chance to jump to the test interface after restart;
389 +* After the backlight is off, there is a small chance that the screen will display abnormal;
390 +* Video play cause stuck problem of General series 9150;
391 +* When the HMI just turned on, Recipe Display on the main screen is displayed as NULL;
392 +* Optimize Lua built-in library and file read/write functions;
393 +* The label of the operation value in the Operation record is displayed abnormal;
394 +* The length of channel name for Data record exceeds 32 bytes, will cause failed recording;
395 +* After entering the installment password, restart immediately, would require entering the password again;
134 134  
135 -F) Use some fonts will cause software crash when compiling the project;
397 +(% class="wikigeneratedid" id="HDriverProtocol-4" %)
398 +Driver Protocol
136 136  
137 -=== **HMI Application** ===
400 +* Frequently screen switching and there are many external addresses on the screen, which might have a little chance cause a stuck problem; 
401 +* Ethernet free tags may cause touch problem with no response;
402 +* Ethernet free tags occur error in compiling the project;
403 +* The input/output terminals of communication with MIKOM PLC are abnormal;
404 +* The reading information from scanner will not display if it exceeds 128 characters;
405 +* Failed to communicate with the OMRON NX/NJ PLC communication after power-on the screen and then power on the PLC.
406 +* When HMI+ is just turned on, the Ethernet communication prompts timeout;
407 +* When communicate with Siemens new protocol, will let the HMI stuck on LOGO screen;
138 138  
139 -A) Occasionally occur stuck logo problem after enable the Index of Recipe function;
409 +(% class="wikigeneratedid" id="HNewfunctions-2" %)
410 +**New functions**
140 140  
141 -B) Frequently screen switching might have a little chance cause stuck problem if there exist many table objects on the screen;
412 +(% class="wikigeneratedid" id="HPCSoftware-5" %)
413 +PC Software
142 142  
143 -C) There is a little chance cause the stuck problem if use the script;
415 +* New ie series: 3043ie, 3043ieS, 3070ie, 3102ie;
416 +* Industry purpose-designated models: ie series 3070ind, 3102ind, I series 3070ind-n;
417 +* Import and export function for Gallery file ( .blb or .plb format);
144 144  
145 -D) The stuck problem if use User permission;
419 +(% class="wikigeneratedid" id="HHMIApplication-5" %)
420 +HMI Application
146 146  
147 -E) The stuck problem when Data record upload;
422 +* VNC LAN monitoring function ( require i series and PI+ models with Ethernet port and customized, the -O model in General series still use HMI Monitor System)
423 +* Resource report function to count the total memory used by the current screen;
424 +* Message prompt list (timeout , message , only available for ie series);
425 +* Timer and Trigger function in Lua script (only available for ie series);
426 +* Lua custom object, Lua table drawing, Lua curve drawing (only available for ie series);
427 +* Continuous input function of numeric and character object;
428 +* 4 Macro script functions involving file operations, FileCmpDir(), MyDeleteFile(), WriteWordToFile(), ReadWordFormFile();
429 +* The backstage interface can upgrade PLC program to support 5VPLC program download (only available for 3000i and PI+ series);
148 148  
149 -F) There is a little chance to jump to the test interface after restart;
431 +(% class="wikigeneratedid" id="HDriverProtocol-5" %)
432 +Driver Protocol
150 150  
151 -G) After the backlight is off, there is a small chance that the screen will display abnormal;
434 +* Keyence KV series;
152 152  
153 -H) Video play cause stuck problem of General series 9150;
436 +== Notification of PI+ ==
154 154  
155 -I) When the HMI just turned on, Recipe Display on the main screen is displayed as NULL;
438 +* [[Download Link>>url:https://drive.google.com/file/d/1UMb8YGc5lLSfoF_UHD5A4HwE_HKd-Qg7/view?usp=sharing]]
156 156  
157 -J) Optimize Lua built-in library and file read/write functions;
440 += **2 Levi2PI** =
158 158  
159 -K) The label of the operation value in the Operation record is displayed abnormal;
442 +== V4.5.8 ==
160 160  
161 -L) The length of channel name for Data record exceeds 32 bytes, will cause failed recording;
444 +* [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Levi2PI.zip]]
162 162  
163 -M) After entering the installment password, restart immediately, would require entering the password again;
446 += **3 HMI Monitor System** =
164 164  
165 -=== **Driver Protocol** ===
448 +== VER: 20210317 ==
166 166  
167 -A) Frequently screen switching and there are many external addresses on the screen, which might have a little chance cause a stuck problem; 
450 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/1RA3ui3jTCKtQTCLySjD4Qi7Ut58EYYD1/view?usp=sharing]]
168 168  
169 -B) Ethernet free tags may cause touch problem with no response;
452 += **4 Logo Making Tool** =
170 170  
171 -C) Ethernet free tags occur error in compiling the project;
172 -
173 -D) The input/output terminals of communication with MIKOM PLC are abnormal;
174 -
175 -E) The reading information from scanner will not display if it exceeds 128 characters;
176 -
177 -F) Failed to communicate with the OMRON NX/NJ PLC communication after power-on the screen and then power on the PLC.
178 -
179 -G) When HMI+ is just turned on, the Ethernet communication prompts timeout;
180 -
181 -H) When communicate with Siemens new protocol, will let the HMI stuck on LOGO screen;
182 -
183 -== **New Functions Added** ==
184 -
185 -=== **PC Software** ===
186 -
187 -A) New ie series: 3043ie, 3043ieS, 3070ie, 3102ie;
188 -
189 -B) Industry purpose-designated models: ie series 3070ind, 3102ind, I series 3070ind-n;
190 -
191 -C) Import and export function for Gallery file ( .blb or .plb format);
192 -
193 -=== **HMI Application** ===
194 -
195 -A) VNC LAN monitoring function ( require i series and PI+ models with Ethernet port and customized, the -O model in General series still use HMI Monitor System)
196 -
197 -B) Resource report function to count the total memory used by the current screen;
198 -
199 -C) Message prompt list (timeout , message , only available for ie series);
200 -
201 -D) Timer and Trigger function in Lua script (only available for ie series);
202 -
203 -E) Lua custom object, Lua table drawing, Lua curve drawing (only available for ie series);
204 -
205 -F) Continuous input function of numeric and character object;
206 -
207 -G) 4 Macro script functions involving file operations, FileCmpDir(), MyDeleteFile(), WriteWordToFile(), ReadWordFormFile();
208 -
209 -H) The backstage interface can upgrade PLC program to support 5VPLC program download (only available for 3000i and PI+ series);
210 -
211 -== **Driver Protocol** ==
212 -
213 -A) Keyence KV series;
214 -
215 -== **Notification of PI+** ==
216 -
217 -**[[Download Link>>url:https://drive.google.com/file/d/1UMb8YGc5lLSfoF_UHD5A4HwE_HKd-Qg7/view?usp=sharing]]**
218 -
219 -= **Levi2PI V4.3.8** =
220 -
221 -**Official Website:**
222 -
223 -**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/Wecon%20LEVI2PI.zip]]**
224 -
225 -**Dropbox:**
226 -
227 -**[[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=Wecon+LEVI2PI.zip&subfolder_nav_tracking=1]]**
228 -
229 -= **Levi2PI V4.5.6(Test Version)** =
230 -
231 -**Google Drive**
232 -
233 -**[[Download Link>>https://drive.google.com/file/d/10Ay8dr7MK6CCpMIKEmKITG3DGipffJsI/view?usp=sharing]]**
234 -
235 -= **HMI Monitor System20210317** =
236 -
237 -**Google Drive:**
238 -
239 -**[[Download Link>>https://drive.google.com/file/d/1RA3ui3jTCKtQTCLySjD4Qi7Ut58EYYD1/view?usp=sharing]]**
240 -
241 -
242 -= **6 Logo Making Tool** =
243 -
244 -**Google Drive:**
245 -
246 -**[[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]**
454 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]
image-20220708184749-1.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.6 KB
Content
image-20220708184750-2.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.6 KB
Content
image-20220708184750-3.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.6 KB
Content
image-20220708184751-4.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.6 KB
Content
image-20220708184751-5.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.6 KB
Content