Changes for page 3 Software

Last modified by Jett on 2025/03/13 14:13

From version 5.1
edited by Hunter
on 2022/07/08 18:32
Change comment: There is no comment for this version
To version 9.1
edited by Stone Wu
on 2022/08/01 15:17
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -5 Software
1 +3 Software
Parent
... ... @@ -1,1 +1,1 @@
1 -PIStudio.WebHome
1 +PIStudio.Download.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.Stone
Content
... ... @@ -1,246 +1,278 @@
1 -= **PIStudio Release Build VER:R05R998_V8.2.62_D20220625** =
1 += **1 PIStudio** =
2 2  
3 +== V8.2.62_D20220625 ==
3 3  
4 -(% class="wikigeneratedid" %)
5 -= **PIStudio Release Build VER:R05R998_V7.2.198_D20211210** =
5 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220625.zip]]
6 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/1kJuuzxjPj5mZmeazhGxrs3lGyMceqmYj/view?usp=sharing]]
6 6  
7 -(% class="wikigeneratedid" %)
8 -**Official Website:**
8 +=== Bugs Fixed ===
9 9  
10 -(% class="wikigeneratedid" %)
11 -**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]]**
10 +(% class="wikigeneratedid" id="HPCSoftware" %)
11 +**PC Software**
12 12  
13 -**Google Drive:**
13 +1. Cloud.xml does not exist in the project file of 8000 series and cannot access cloud;
14 +1. Lua prompting error when double click the project path of General series in Screen Management;
15 +1. The cursor moving into the area of background script will be disappeared;
16 +1. After the Lua script is changed, it is not compiled, and there is no prompt when clicking offline simulation;
17 +1. DLView fails to import excel files;
18 +1. There is an abnormality when creating image files into Udisk;
19 +1. Orientation options missing for Slide switch;
20 +1. COM3 Configuration missing for following models: 3070i-A and 3102i-A;
21 +1. When the download tool downloads the project, it does not prompt when the file does not exist;
22 +1. SD Card option missing for following models: 3070i-A, 3102i-A, 3070i-C, 3102i-C;
23 +1. Some of the same font size, font style is different when the font size is displayed abnormally;
24 +1. Optimize the built-in screen No.1008, add Time and Date objects;
25 +1. Optimize the remote download;
26 +1. Optimize the U disk upgrade function;
27 +1. Prompt when the downloads a file with a long path;
28 +1. The ig series vertical screen option is available now;
14 14  
15 -**[[Download Link>>https://drive.google.com/file/d/1lRfgoOwAs7lgL4b-ZdVUvE6itHWCpfd5/view?usp=sharing]]**
30 +(% class="wikigeneratedid" id="HHMIApplication" %)
31 +**HMI Application**
16 16  
17 -== **Bugs Fixed** ==
33 +1. The i series freezes with HSW24 soft reboot;
34 +1. Debugging window cannot be closed on the ig monitoring page;
35 +1. Abnormal record time of ig Data record;
36 +1. The ig series abnormal ethernet communication;
37 +1. The register for network status HSW850 abnormal value;
38 +1. Lua we_bas_getstring script function execution error;
39 +1. The video title with English brackets cannot be played;
40 +1. Touch screen will lead to HMI freezes when keyboard input and cursor is enabled;
41 +1. Logo failed download for PI8150ig (before the firmware version 0313);
42 +1. After PI8000 series remote download PLC program, PLC cannot communicate;
43 +1. PI8000 series and ig series online V-NET but cannot remote control;
44 +1. Background Ethernet static IP configuration is not saved;
45 +1. The ig series WVPN remote pass through fails;
46 +1. Lua timer does not perform timing operations according to the interval;
18 18  
19 -=== **PC Software** ===
48 +(% class="wikigeneratedid" id="HDriverProtocol" %)
49 +**Driver Protocol**
20 20  
21 -A) Optimize the display style of text objects;
51 +1. PI8000ig and Yudian sensor cannot communicate;
52 +1. Modify the name of the Wecon LX6V protocol, the old version project must be re-selected;
53 +1. The following serial port protocols have intermittent communication timeout issue: Siemens S7-200 smart, modbus, INVT, etc.
54 +1. Taian AP200 C register can not read the value
22 22  
23 -B) Optimize Lua script file size limitation to 512KB;
56 +=== New Functions Added ===
24 24  
25 -C) Optimize the import of text library and the limitation to 2000;
58 +(% class="wikigeneratedid" id="HPCSoftware-1" %)
59 +**PC Software**
26 26  
27 -D) Protocol driver names standardized;
61 +1. VB script customize naming function;
62 +1. PI Suite toolkit;
63 +1. System upgrade function;
64 +1. PIRecordUpload has added User permission function;
65 +1. Cloud function of 8000 and 9000 series;
28 28  
29 -E) Font size is open to 512;
67 +(% class="wikigeneratedid" id="HHMIApplication-1" %)
68 +**HMI Application**
30 30  
31 -F) Lua script debugging window can be configured as enabled or not in Project Settings;
70 +The following function is only available for ig series:
32 32  
33 -G) Optimize the font display of Runbar;
72 +1. Slider of History trend chart can set the color and transparency;
73 +1. Continuous read and write addresses in Lua script;
74 +1. Built-in Lua extension module;
75 +1. Display network camera on HMI screen for 8150ig;
76 +1. Vertical Display;
77 +1. The priority settings of Cloud connection method from backstage configuration;
78 +1. Lua script supports https protocol now;
79 +1. UDisk Download project prohibit upload function;
80 +1. Lua script luasqlite operation;
81 +1. The following function is only available for i,ie,ig series and HMI+ system:
82 +1. All series remove the restriction of special machine code;
83 +1. Recipe 64-bit floating point number data format;
84 +1. UDisk Pop-Up function;
85 +1. Interconversion between GB2312 and UTF-8 encoding;
86 +1. UDisk download PLC multi-file function;
87 +1. Modifitable datetime prohibited;
88 +1. Color configuration of Line object;
34 34  
35 -H) Optimized the forced backup function of project file, now you can click the cancel button to not backup;
90 +(% class="wikigeneratedid" id="HDriverProtocol-1" %)
91 +**Driver Protocol**
36 36  
37 -I) Optimized and adjusted the default size of the password keyboard screen of newly-created projects;
93 +1. Inovance H3U Ethernet;
94 +1. Rockwell micro850 Ethernet/IP Free Tags;
95 +1. Wecon LX6V Free Tags;
38 38  
39 -J) Wrong display range of the History trend chart;
97 +=== New Models ===
40 40  
41 -K) The font display of Drop-down List on PC is different from the actual screen;
99 +1. The i series: 3070i-A, 3102i-A, 3070i-C, 3102i-C, 3070i-2S, 3102i-2S
100 +1. The ie series: 3043ie-T
101 +1. The ig series: 8150ig
42 42  
43 -L) Software crash caused by deleting the Address Library name;
103 +(% class="box infomessage" %)
104 +(((
105 +✎Note:
44 44  
45 -M) General Series SMS protocol cannot be selected;
107 +* To use the new functions avaiable from new version, the project needs to be downloaded twice;
108 +* After the wifi module (version V1.1) of 3070ig is soft restarted, if the wifi is not recognized from background interface, please repower to recover it;
109 +)))
46 46  
47 -=== **HMI Application** ===
111 +== V7.2.198_D20211210 ==
48 48  
49 -A) Multi-Language display of text fonts;
113 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]]
114 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/1lRfgoOwAs7lgL4b-ZdVUvE6itHWCpfd5/view?usp=sharing]]
50 50  
51 -B) Password keyboard input to display the plain text first and then the * sign;
116 +=== Bugs Fixed ===
52 52  
53 -C) Prompt display of Screen Lock for ie and ig;
118 +(% class="wikigeneratedid" id="HPCSoftware-2" %)
119 +**PC Software**
54 54  
55 -D) Auto refresh of Data Record;
121 +* Optimize the display style of text objects;
122 +* Optimize Lua script file size limitation to 512KB;
123 +* Optimize the import of text library and the limitation to 2000;
124 +* Protocol driver names standardized;
125 +* Font size is open to 512;
126 +* Lua script debugging window can be configured as enabled or not in Project Settings;
127 +* Optimize the font display of Runbar;
128 +* Optimized the forced backup function of project file, now you can click the cancel button to not backup;
129 +* Optimized and adjusted the default size of the password keyboard screen of newly-created projects;
130 +* Wrong display range of the History trend chart;
131 +* The font display of Drop-down List on PC is different from the actual screen;
132 +* Software crash caused by deleting the Address Library name;
133 +* General Series SMS protocol cannot be selected;
56 56  
57 -=== **Driver Protocol** ===
135 +(% class="wikigeneratedid" id="HHMIApplication-2" %)
136 +**HMI Application**
58 58  
59 -A) Communication cannot be performed after entering the backstage project;
138 +* Multi-Language display of text fonts;
139 +* Password keyboard input to display the plain text first and then the * sign;
140 +* Prompt display of Screen Lock for ie and ig;
141 +* Auto refresh of Data Record;
60 60  
61 -B) Stuck screen problem caused by the protocol IEC60870-104 Client;
143 +(% class="wikigeneratedid" id="HDriverProtocol-2" %)
144 +**Driver Protocol**
62 62  
63 -== **New Functions Added** ==
146 +* Communication cannot be performed after entering the backstage project;
147 +* Stuck screen problem caused by the protocol IEC60870-104 Client;
64 64  
65 -=== **PC Software** ===
149 +=== New Functions Added ===
66 66  
67 -A) New ie series model: 3035ie;
151 +(% class="wikigeneratedid" id="HPCSoftware-3" %)
152 +**PC Software**
68 68  
69 -B) New ig series models: 3070ig, 3102ig;
154 +* New ie series model: 3035ie;
155 +* New ig series models: 3070ig, 3102ig;
156 +* License agreement for the software installation setup process;
157 +* Object Lock/Unlock function (Pushpin);
158 +* Lua Editor to highlight the same content of the selected text;
159 +* Font style settings of the Runbar and chart type objects;
160 +* Software installation package VC 2017 runtime library;
70 70  
71 -C) License agreement for the software installation setup process;
162 +(% class="wikigeneratedid" id="HHMIApplication-3" %)
163 +**HMI Application**
72 72  
73 -D) Object Lock/Unlock function (Pushpin);
165 +* Recipe address discontinuous address setting;
166 +* Trim 0 display setting for numeric input;
167 +* Address Mapping continuous writing settings;
168 +* Screensaver function;
169 +* Multi-Link function (not supported by ie and ig series);
170 +* Traditional recipe function is only applicable to the LEVI2PI project that uses the Recipe function;
171 +* Disc Record Chart;
172 +* Lua script weather forecast function interfaces;
173 +* The ie series supports the barcode scanner;
74 74  
75 -E) Lua Editor to highlight the same content of the selected text;
175 +(% class="wikigeneratedid" id="HDriverProtocol-3" %)
176 +**Driver Protocol**
76 76  
77 -F) Font style settings of the Runbar and chart type objects;
178 +* Koyo Modbus RTU;
179 +* ASK series;
180 +* Anda inverter;
181 +* Optimize the barcode scanner protocol;
78 78  
79 -G) Software installation package VC 2017 runtime library;
183 +== V7.1.117_D20210320 ==
80 80  
81 -=== **HMI Application** ===
185 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20210320.zip]]
186 +* Dropbox: [[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=PIStudio20210320.zip&subfolder_nav_tracking=1]]
82 82  
83 -A) Recipe address discontinuous address setting;
188 +=== Bugs Fixed ===
84 84  
85 -B) Trim 0 display setting for numeric input;
190 +(% class="wikigeneratedid" id="HPCSoftware-4" %)
191 +**PC Software**
86 86  
87 -C) Address Mapping continuous writing settings;
193 +* Fix the crash problem of the software;
194 +* Renew the wiring diagram and pin definition diagram;
195 +* After the address is annotated, still able to communicate in Lua script;
196 +* Ethernet download optimization;
197 +* The project folder contains special language characters(except Chinese and English), errors in compiling Lua file and project, failed to download the project;
198 +* Use some fonts will cause software crash when compiling the project;
88 88  
89 -D) Screensaver function;
200 +(% class="wikigeneratedid" id="HHMIApplication-4" %)
201 +**HMI Application**
90 90  
91 -E) Multi-Link function (not supported by ie and ig series);
203 +* Occasionally occur stuck logo problem after enable the Index of Recipe function;
204 +* B) Frequently screen switching might have a little chance cause stuck problem if there exist many table objects on the screen;
205 +* There is a little chance cause the stuck problem if use the script;
206 +* The stuck problem if use User permission;
207 +* The stuck problem when Data record upload;
208 +* There is a little chance to jump to the test interface after restart;
209 +* After the backlight is off, there is a small chance that the screen will display abnormal;
210 +* Video play cause stuck problem of General series 9150;
211 +* When the HMI just turned on, Recipe Display on the main screen is displayed as NULL;
212 +* Optimize Lua built-in library and file read/write functions;
213 +* The label of the operation value in the Operation record is displayed abnormal;
214 +* The length of channel name for Data record exceeds 32 bytes, will cause failed recording;
215 +* After entering the installment password, restart immediately, would require entering the password again;
92 92  
93 -F) Traditional recipe function is only applicable to the LEVI2PI project that uses the Recipe function;
217 +(% class="wikigeneratedid" id="HDriverProtocol-4" %)
218 +**Driver Protocol**
94 94  
95 -G) Disc Record Chart;
220 +* Frequently screen switching and there are many external addresses on the screen, which might have a little chance cause a stuck problem; 
221 +* Ethernet free tags may cause touch problem with no response;
222 +* Ethernet free tags occur error in compiling the project;
223 +* The input/output terminals of communication with MIKOM PLC are abnormal;
224 +* The reading information from scanner will not display if it exceeds 128 characters;
225 +* Failed to communicate with the OMRON NX/NJ PLC communication after power-on the screen and then power on the PLC.
226 +* When HMI+ is just turned on, the Ethernet communication prompts timeout;
227 +* When communicate with Siemens new protocol, will let the HMI stuck on LOGO screen;
96 96  
97 -H) Lua script weather forecast function interfaces;
229 +=== New Functions Added ===
98 98  
99 -I) The ie series supports the barcode scanner;
231 +(% class="wikigeneratedid" id="HPCSoftware-5" %)
232 +**PC Software**
100 100  
101 -=== **Driver Protocol** ===
234 +* New ie series: 3043ie, 3043ieS, 3070ie, 3102ie;
235 +* Industry purpose-designated models: ie series 3070ind, 3102ind, I series 3070ind-n;
236 +* Import and export function for Gallery file ( .blb or .plb format);
102 102  
103 -A) Koyo Modbus RTU;
238 +(% class="wikigeneratedid" id="HHMIApplication-5" %)
239 +**HMI Application**
104 104  
105 -B) ASK series;
241 +* VNC LAN monitoring function ( require i series and PI+ models with Ethernet port and customized, the -O model in General series still use HMI Monitor System)
242 +* Resource report function to count the total memory used by the current screen;
243 +* Message prompt list (timeout , message , only available for ie series);
244 +* Timer and Trigger function in Lua script (only available for ie series);
245 +* Lua custom object, Lua table drawing, Lua curve drawing (only available for ie series);
246 +* Continuous input function of numeric and character object;
247 +* 4 Macro script functions involving file operations, FileCmpDir(), MyDeleteFile(), WriteWordToFile(), ReadWordFormFile();
248 +* The backstage interface can upgrade PLC program to support 5VPLC program download (only available for 3000i and PI+ series);
106 106  
107 -C) Anda inverter;
250 +(% class="wikigeneratedid" id="HDriverProtocol-5" %)
251 +**Driver Protocol**
108 108  
109 -D) Optimize the barcode scanner protocol;
253 +* Keyence KV series;
110 110  
111 -= **PIStudio Release Build VER:R05R998_V7.1.117_D20210320** =
255 +== Notification of PI+ ==
112 112  
113 -**Official Website:**
257 +[[Download Link>>url:https://drive.google.com/file/d/1UMb8YGc5lLSfoF_UHD5A4HwE_HKd-Qg7/view?usp=sharing]]
114 114  
115 -**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20210320.zip]]**
259 += **2 Levi2PI** =
116 116  
117 -**Dropbox:**
261 +== V4.3.8 ==
118 118  
119 -**[[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=PIStudio20210320.zip&subfolder_nav_tracking=1]]**
263 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Wecon%20LEVI2PI.zip]]
264 +* Dropbox: [[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=Wecon+LEVI2PI.zip&subfolder_nav_tracking=1]]
120 120  
121 -== **Bugs Fixed** ==
266 +== V4.5.6(Test Version) ==
122 122  
123 -=== **PC Software** ===
268 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/10Ay8dr7MK6CCpMIKEmKITG3DGipffJsI/view?usp=sharing]]
124 124  
125 -A) Fix the crash problem of the software;
270 += **3 HMI Monitor System** =
126 126  
127 -B) Renew the wiring diagram and pin definition diagram;
272 +== VER: 20210317 ==
128 128  
129 -C) After the address is annotated, still able to communicate in Lua script;
274 +**Google Drive: [[Download Link>>https://drive.google.com/file/d/1RA3ui3jTCKtQTCLySjD4Qi7Ut58EYYD1/view?usp=sharing]]**
130 130  
131 -D) Ethernet download optimization;
276 += **4 Logo Making Tool** =
132 132  
133 -E) The project folder contains special language characters(except Chinese and English), errors in compiling Lua file and project, failed to download the project;
134 -
135 -F) Use some fonts will cause software crash when compiling the project;
136 -
137 -=== **HMI Application** ===
138 -
139 -A) Occasionally occur stuck logo problem after enable the Index of Recipe function;
140 -
141 -B) Frequently screen switching might have a little chance cause stuck problem if there exist many table objects on the screen;
142 -
143 -C) There is a little chance cause the stuck problem if use the script;
144 -
145 -D) The stuck problem if use User permission;
146 -
147 -E) The stuck problem when Data record upload;
148 -
149 -F) There is a little chance to jump to the test interface after restart;
150 -
151 -G) After the backlight is off, there is a small chance that the screen will display abnormal;
152 -
153 -H) Video play cause stuck problem of General series 9150;
154 -
155 -I) When the HMI just turned on, Recipe Display on the main screen is displayed as NULL;
156 -
157 -J) Optimize Lua built-in library and file read/write functions;
158 -
159 -K) The label of the operation value in the Operation record is displayed abnormal;
160 -
161 -L) The length of channel name for Data record exceeds 32 bytes, will cause failed recording;
162 -
163 -M) After entering the installment password, restart immediately, would require entering the password again;
164 -
165 -=== **Driver Protocol** ===
166 -
167 -A) Frequently screen switching and there are many external addresses on the screen, which might have a little chance cause a stuck problem; 
168 -
169 -B) Ethernet free tags may cause touch problem with no response;
170 -
171 -C) Ethernet free tags occur error in compiling the project;
172 -
173 -D) The input/output terminals of communication with MIKOM PLC are abnormal;
174 -
175 -E) The reading information from scanner will not display if it exceeds 128 characters;
176 -
177 -F) Failed to communicate with the OMRON NX/NJ PLC communication after power-on the screen and then power on the PLC.
178 -
179 -G) When HMI+ is just turned on, the Ethernet communication prompts timeout;
180 -
181 -H) When communicate with Siemens new protocol, will let the HMI stuck on LOGO screen;
182 -
183 -== **New Functions Added** ==
184 -
185 -=== **PC Software** ===
186 -
187 -A) New ie series: 3043ie, 3043ieS, 3070ie, 3102ie;
188 -
189 -B) Industry purpose-designated models: ie series 3070ind, 3102ind, I series 3070ind-n;
190 -
191 -C) Import and export function for Gallery file ( .blb or .plb format);
192 -
193 -=== **HMI Application** ===
194 -
195 -A) VNC LAN monitoring function ( require i series and PI+ models with Ethernet port and customized, the -O model in General series still use HMI Monitor System)
196 -
197 -B) Resource report function to count the total memory used by the current screen;
198 -
199 -C) Message prompt list (timeout , message , only available for ie series);
200 -
201 -D) Timer and Trigger function in Lua script (only available for ie series);
202 -
203 -E) Lua custom object, Lua table drawing, Lua curve drawing (only available for ie series);
204 -
205 -F) Continuous input function of numeric and character object;
206 -
207 -G) 4 Macro script functions involving file operations, FileCmpDir(), MyDeleteFile(), WriteWordToFile(), ReadWordFormFile();
208 -
209 -H) The backstage interface can upgrade PLC program to support 5VPLC program download (only available for 3000i and PI+ series);
210 -
211 -== **Driver Protocol** ==
212 -
213 -A) Keyence KV series;
214 -
215 -== **Notification of PI+** ==
216 -
217 -**[[Download Link>>url:https://drive.google.com/file/d/1UMb8YGc5lLSfoF_UHD5A4HwE_HKd-Qg7/view?usp=sharing]]**
218 -
219 -= **Levi2PI V4.3.8** =
220 -
221 -**Official Website:**
222 -
223 -**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/Wecon%20LEVI2PI.zip]]**
224 -
225 -**Dropbox:**
226 -
227 -**[[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=Wecon+LEVI2PI.zip&subfolder_nav_tracking=1]]**
228 -
229 -= **Levi2PI V4.5.6(Test Version)** =
230 -
231 -**Google Drive**
232 -
233 -**[[Download Link>>https://drive.google.com/file/d/10Ay8dr7MK6CCpMIKEmKITG3DGipffJsI/view?usp=sharing]]**
234 -
235 -= **HMI Monitor System20210317** =
236 -
237 -**Google Drive:**
238 -
239 -**[[Download Link>>https://drive.google.com/file/d/1RA3ui3jTCKtQTCLySjD4Qi7Ut58EYYD1/view?usp=sharing]]**
240 -
241 -
242 -= **6 Logo Making Tool** =
243 -
244 -**Google Drive:**
245 -
246 -**[[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]**
278 +**Google Drive: [[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]**
image-20220708184749-1.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.6 KB
Content
image-20220708184750-2.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.6 KB
Content
image-20220708184750-3.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.6 KB
Content
image-20220708184751-4.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.6 KB
Content
image-20220708184751-5.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.6 KB
Content