欢迎图片

Changes for page 3 Software

Last modified by Hunter on 2025/11/24 09:49

From version 6.5
edited by Hunter
on 2025/11/22 16:31
Change comment: There is no comment for this version
To version 9.1
edited by Hunter
on 2025/11/24 09:49
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,8 @@
1 -1. (((
1 +(((
2 2  = **1 PIStudio** =
3 3  )))
4 -1. (((
4 +
5 +(((
5 5  == **V10.5.45.25102301(PI9000ig, RL, RH, WP)** ==
6 6  )))
7 7  
... ... @@ -15,12 +15,48 @@
15 15  **Bugs fixed**
16 16  
17 17  1. Slow response issue with IN series HMI;
18 -1. (((
19 -Slow response of Alarm record and address monitoring table, and stuck when opening the project
20 -)))
19 +1. Slow response of alarm record and address monitoring table, and stuck when opening the project;
20 +1. LREAL data type cannot be read and written;
21 +1. The overlapping screen cannot be set when the sub-screen is selected in screen;
22 +1. The encoding method options for string type data in Data record;
23 +1. Communication failure on Ethernet2 of HMI when using IP address from different Subnets for Ethernet1 and Ethernet2.
24 +1. The addresses of X and Y are inconsistent in XY trend chart,;
25 +1. Object lock cannot be an index address;
26 +1. Lagging display of camera;
27 +1. Stuck on logo issue during IN, IE series upgrade;
28 +1. The IN series HMI do not support the mouse style configuration;
29 +1. Failure to download projects to IN series HMI ;
30 +1. PDF prompts display abnormal;
31 +1. CAN port configuration communication error;
32 +1. When RH device uses 4K resolution, the fonts of message prompt, background, etc. are too small;
33 +1. The issue of translator multi-language;
34 +1. Invalid address mapping;
35 +1. The advanced configuration effect of device search, device management and cloud management download project not match the expected results;
36 +1. RH-00 communication configuration does not have ETH2 configuration;
37 +1. The ig model system keyboard is not working;
38 +1. The ig, RH series vertical screen mouse movement and touch optimized;
39 +1. 4.3-inch HMI vertical screen background display effect;
40 +1. Issue of Siemens S7-1200 DBS register reads and writes less than half, need to check the ”Read DWord” option;
41 +1. OPC UA Client reads and writes strings issue, if the new string is shorter than the old one, the end of the old string will be remained;
42 +1. If using too many element in recipe for JUNCAUTO protocol, the address will be clean and overwrite the data in low addresses;
43 +1. Write LX5V bit-in-word;
44 +1. OPC UA Client cannot connect to the server configured with authentication;
45 +1. OPC UA Client cannot reconnect normally after unplugging/plugging the network cable;
46 +1. Changing communication methods in the background is invalid;
47 +1. Set user permissions on the screen, but the register cannot jump to this screen;
48 +1. The issue of abnormal using indirect screen on sub-screen;
49 +1. Abnormal display of the bar graph ;
50 +1. The RH series cannot use the CODESYS protocol;
51 +1. When the simulator's print object is set to screenshot mode, the screen cannot be switched after a screenshot.
52 +1. Operation records do not support text variable insert;
53 +1. Object or font shrinking when moving numeric object;
54 +1. CODESYS V3 protocol cannot read the Unicode string of LX6C (WSTRING);
55 +1. The issue with the UNION type data in Omron;
56 +1. Communication failure after the end of VPN pass-through, ;
57 +1. Communication failure between Keyence KV series protocol and 9000ig series;
58 +1. Gallery size limitation per screen for IN, IE and RH series;
59 +1. Other issues;
21 21  
22 -
23 -
24 24  (% class="wikigeneratedid" %)
25 25  **New functions**
26 26  
... ... @@ -27,6 +27,44 @@
27 27  (% class="wikigeneratedid" %)
28 28  PC Software
29 29  
67 +1. Software style selection;
68 +1. Screen layer;
69 +1. Template screen;
70 +1. Project tree objects list;
71 +1. Software settings page;
72 +1. The color palette adds a color picker;
73 +1. Address priority configuration;
74 +1. German is added to the software language;
75 +1. Automatic project backup;
76 +1. Address list search replacement;
77 +1. Import and export of user login information;
78 +1. The toolbar adds an upload project entrance and a toolbox entrance;
79 +1. UI enhancement;
80 +1. Software toolbar layout optimized;
81 +1. Address compilation optimized;
82 +1. Address integration optimized;
83 +1. Project multi-language translation(Only Baidu API key);
84 +1. Sound library configuration;
85 +1. BACNet server;
86 +1. Address search and replace;
87 +1. String table text alignment;
88 +1. Support for string table configuration
89 +1*. Drop-down list;
90 +1*. Data Record (channel name);
91 +1*. Recipe(element name);
92 +1*. Bit alarm text;
93 +1*. Word alarm text;
94 +1. Object copy attributes (font/size/color) to other languages;
95 +1. Project format upgrade.(.pi to .pi2)
96 +1. After the communication port connection is deleted, the communication port number is automatically sorted;
97 +1. Sub-screen pops up coordinate configuration;
98 +1. Alarm address communication priority (import/export);
99 +1. Text tag function;
100 +1. Text position vertical adjustment;
101 +1. Beckhoff tag import filtering;
102 +1. Schedule ;
103 +1. Column Chart object;
104 +1. Improve the success rate of pass-through;
30 30  
31 31  (% class="wikigeneratedid" %)
32 32  HMI Application
... ... @@ -52,29 +52,27 @@
52 52  1. Text-To-Speech;
53 53  1. Voice broadcast;
54 54  1. The message prompt module supports 48 languages;
55 -1. Add remote management module in the background;
56 -1. Remote background;
57 -1. Access verification function;
58 -1. IP restriction function;
59 -1. Equipment control function;
60 -1. Access log viewing function;
130 +1. Remote management module in the background;
131 +1*. Remote background;
132 +1*. Access verification;
133 +1*. IP Whitelist/Blacklist;
134 +1*. Access log viewing;
61 61  1. Configure network routing mode, switch mode and WIFI hotspot in the background
62 62  1. RH series, 9000ig series DIP switch function
63 -11. Factory reset
64 -11. Touch calibration adaptation;
137 +1*. Factory reset
138 +1*. Touch calibration adaptation;
65 65  1. Vertical alignment method for text display;
66 -1. Histogram object;
140 +1. Column Chart;
67 67  1. Text tag function;
68 68  1. Supports control via special registers to adjust the button size and spacing on the new Alarm record object, new Recipe Record object, and Column Chart;
69 69  1. The text for email content, user login (username), user login (description), and log message text (operation records) supports configuration via a string table.
70 -1. Scheduling function;
71 -1. Optimized: Sub-screen pop-up position optimization;
144 +1. Task scheduler;
145 +1. Sub-screen pop-up position optimization;
72 72  1. RE and RL series support NTP (network time protocol) function;
73 73  
74 74  (% class="wikigeneratedid" %)
75 75  **New drive**
76 76  
77 -
78 78  1. Winding Machine MODBUS RTU Winder;
79 79  1. KEYENCE EtherNet/IP (KV-8000);
80 80  1. KEYENCE EtherNet/IP (KV-X310);
... ... @@ -105,7 +105,6 @@
105 105  (% class="wikigeneratedid" %)
106 106  **New models**
107 107  
108 -
109 109  1. GB series: GB3041, GB3070, GB3101, GB8041, GB8070-H, GB8101;
110 110  1. ig series: PI9102ig, PI9121ig, PI9150ig, PI9151ig;
111 111  1. WP series: WP2070, WP2071, WP3070, WP3071;