... ... @@ -1,16 +1,106 @@
1 -1. (((
1 +(((
2 2  = **1 PIStudio** =
3 +
4 +== **V10.6.32.26042802** ==
5 +
6 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/PIStudio_10.6.45.26070101.zip]]
7 +
8 +**Bugs fixed**
9 +
10 +1. Object -level password check option “Becomes the lowest level”;
11 +1. Static IP inaccessible after VPN pass-through;
12 +1. Multi-language switching not supported when exporting alarm record files;
13 +1. Some fonts displayed offset in remote screens;
14 +1. Indirect screens displayed abnormally in Remote monitoring;
15 +1. Some fonts displayed abnormally;
16 +1. Connecting Easy521 with INOVANCE H5U PLC via Ethernet protocol causes partial register addresses to fail to be read on the screen.
17 +1. RH-WG-LA unable to communicate with LX6C via WiFi;
18 +1. S7-1200 protocol string data issue;
19 +1. After a project is set to read-only mode, other projects cannot be opened afterward;
20 +1. Background function custom parameter display failure;
21 +1. Multi-layer nested indirect screens displayed abnormally;
22 +1. Indirect screens flickered when screen switching;
23 +1. Alarm Runbar failed to display blank spaces for alarms;
24 +1. Freetag communication indicator showed incorrect status;
25 +1. OPC UA client crash caused by repeated connection;
26 +1. Communication failure of SIEMENS AGLink protocol via Ethernet2
27 +1. The KEYENCE KV-5000 protocol incomplete device address range.
28 +1. AB CompactLogix communication failure;
29 +1. Sub-screens not fully displayed when zoomed in;
30 +1. The popup of the function switch configuration interface shows coordinate position setting error;
31 +1. Inappropriate translation in some configuration screens;
32 +1. Modifying the hidden bit address of a text object will clear the text content.
33 +1. A beep still sounds when clicking after the drop-down list is hidden.
34 +1. Errors occur when a static IP is configured in the background without DNS setup.
35 +1. File list select-all copy-paste operation failed;
36 +1. Some special symbols displayed abnormally in Runbar messages;
37 +1. Meter object digital status failed to display normally;
38 +1. Alarm record display filter cumulative time and occurrence count sorting ineffective;
39 +1. Alarm record row space color setting ineffective;
40 +1. BACnet driver-related issues;
41 +1. H5U Ethernet protocol communication timeout problem;
42 +1. "Not created by this software" when opening projects in specific conditions;
43 +1. Bit alarm import anomaly in specific conditions;
44 +1. When the project has multiple templates, only one can be displayed in specific conditions;
45 +1. Private deployment URL configuration failure in specific conditions;
46 +1. No compilation error occurs after removing an address from the address library;
47 +1. Using the address list replacement function clears VB scripts.
48 +1. OMRON PLC communication timeout.
49 +1. Indirect screens flickered when screen switching;
50 +1. High delay in message prompt popups in specific conditions;
51 +1. Failed to connect to encrypted MQTT servers;
52 +1. MQTT publish error in Lua script;
53 +1. Communication failure between RH-WG-LA and LX6C via Wi-Fi.
54 +1. Communication anomaly in INOVANCE H5U PLC Ethernet protocol in specific conditions;
55 +1. SMS sending error in Lua script;
56 +1. Timeout occurs when continuously writing over 800 addresses to SCHNEIDER M221 PLC via Ethernet;
57 +1. Optimize loading speed of numeric input and text input controls;
58 +1. Optimize layout and style of background interface;
59 +1. Optimize loading speed of background WIFI configuration page;
60 +1. Optimize background prompt messages;
61 +1. Optimize communication efficiency of free tags;
62 +1. New calibration interface;
63 +1. Optimize click response speed of dropdown list;
64 +1. Optimize loading speed of alarm data during device startup;
65 +1. Other issues;
66 +
67 +**New functions**
68 +
69 +**PC software**
70 +
71 +1. Added: MQTT multi-server configuration;
72 +1. Add downloaded project path and update version No. for device management tool title;
73 +1. Europe 2.0 server option
74 +
75 +**HMI application**
76 +
77 +1. Display user storage space in background;
78 +1. Background online upgrade channel;
79 +1. Support European V2.0 server configuration in background;
80 +1. Register HSW2108 sets the scrollbar width of dropdown list;
81 +1. Lua interface for device name configuration;
82 +1. Register HSW893 controls synchronous/asynchronous mode of user permission between web terminal and touch screen terminal.
83 +1. Lua interface for selecting sound card of TTS voice playback;
84 +1. Registers HSW11829 and HSW11830 control keyboard mask transparency;
85 +1. Register HSW11831 controls enable/disable of long-press countdown animation effect;
86 +1. Optimize built-in virtual keyboard to support continuous text input after pressing backspace key;
87 +
88 +**New drive**
89 +
90 +1. KEYENCE KV-7000/8000 (Ethernet);
91 +1. Siemens S7-1200 Ethernet new protocol adds DBxDBLW four-word register;
92 +1. Siemens S7-200 Smart (Ethernet) V3/G2 drive;
93 +1. MIT Q Series CPU MELSEC PROTOCOL;
94 +1. MIT iQ-L Series CPU MELSEC PROTOCOL;
95 +1. MIT iQ-R Series CPU MELSEC PROTOCOL;
3 3  )))
4 -1. (((
5 -== **V10.5.45.25102301(PI9000ig, RL, RH, WP)** ==
97 +
98 +(((
99 +== **V10.5.45.25102301(New available modules: PI9000ig, RL, RH, WP)** ==
6 6  )))
7 7  
8 8  * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_10.5.zip]]
9 9  
10 -{{warning}}
11 -This test version software is only available for the following models: PI9000ig series, RL series, RH series, and WP series. For all other models, the released version is recommended as the first priority.
12 -{{/warning}}
13 -
14 14  (% class="wikigeneratedid" %)
15 15  **Bugs fixed**
16 16  
... ... @@ -18,48 +18,43 @@
18 18  1. Slow response of alarm record and address monitoring table, and stuck when opening the project;
19 19  1. LREAL data type cannot be read and written;
20 20  1. The overlapping screen cannot be set when the sub-screen is selected in screen;
21 -1. Software crash caused by too many project tag and alarm points;
22 -1. The encoding method cannot be selected when recording string data;
111 +1. The encoding method options for string type data in Data record;
23 23  1. Communication failure on Ethernet2 of HMI when using IP address from different Subnets for Ethernet1 and Ethernet2.
24 24  1. The addresses of X and Y are inconsistent in XY trend chart,;
25 -1. The address monitor is limited to one text address.
26 26  1. Object lock cannot be an index address;
27 -1. Choppy display from the camera;
28 -1. Logo display issue during IN, IE series upgrade;
115 +1. Lagging display of camera;
116 +1. Stuck on logo issue during IN, IE series upgrade;
29 29  1. The IN series HMI do not support the mouse style configuration;
30 30  1. Failure to download projects to IN series HMI ;
31 31  1. PDF prompts display abnormal;
32 32  1. CAN port configuration communication error;
33 33  1. When RH device uses 4K resolution, the fonts of message prompt, background, etc. are too small;
34 -1. Fixed:The issue of translator multi-language;
122 +1. The issue of translator multi-language;
35 35  1. Invalid address mapping;
36 36  1. The advanced configuration effect of device search, device management and cloud management download project not match the expected results;
37 -1. RH-00 communication port configuration does not have network port2 configuration ;
125 +1. RH-00 communication configuration does not have ETH2 configuration;
38 38  1. The ig model system keyboard is not working;
39 -1. Optimized: Remote cloud and pass-through;
40 -1. Optimized: Ig, RH series vertical screen mouse movement and touch;
41 -1. Optimization: 4.3-inch HMI vertical screen background display effect;
42 -1. Fixed:Issue of Siemens S7-1200 DBS register reads and writes less than half, need to check the ”Read Double Bytes”;
43 -1. The issue of OPCUA client reads and writes strings, if the new string is shorter than the old one, the end of the old string will be remained;
44 -1. When the recipe in the JUNCAUTO protocol is too large, the address will be clean and overwrite the data in low addresses;
45 -1. The issue with a bit in the LX5V word;
46 -1. OPCUA Client cannot connect to the server configured with authentication;
47 -1. OPCUA Client cannot reconnect normally after unplugging/plugging the network cable;
127 +1. The ig, RH series vertical screen mouse movement and touch optimized;
128 +1. 4.3-inch HMI vertical screen background display effect;
129 +1. Issue of Siemens S7-1200 DBS register reads and writes less than half, need to check the ”Read DWord” option;
130 +1. OPC UA Client reads and writes strings issue, if the new string is shorter than the old one, the end of the old string will be remained;
131 +1. If using too many element in recipe for JUNCAUTO protocol, the address will be clean and overwrite the data in low addresses;
132 +1. Write LX5V bit-in-word;
133 +1. OPC UA Client cannot connect to the server configured with authentication;
134 +1. OPC UA Client cannot reconnect normally after unplugging/plugging the network cable;
48 48  1. Changing communication methods in the background is invalid;
49 49  1. Set user permissions on the screen, but the register cannot jump to this screen;
50 -1. The issue of abnormal using indirect pictures on sub-screen;
137 +1. The issue of abnormal using indirect screen on sub-screen;
51 51  1. Abnormal display of the bar graph ;
52 52  1. The RH series cannot use the CODESYS protocol;
53 53  1. When the simulator's print object is set to screenshot mode, the screen cannot be switched after a screenshot.
54 -1. Operation records do not support multi-variable;
141 +1. Operation records do not support text variable insert;
55 55  1. Object or font shrinking when moving numeric object;
56 -1. The issue with quotation marks in recipe data after export/import on the 9000ig HMI;
57 -1. IN1072 cannot communicate with Siemens s7-200smart;
58 58  1. CODESYS V3 protocol cannot read the Unicode string of LX6C (WSTRING);
59 -1. The issue with the union in Omron;
144 +1. The issue with the UNION type data in Omron;
60 60  1. Communication failure after the end of VPN pass-through, ;
61 61  1. Communication failure between Keyence KV series protocol and 9000ig series;
62 -1. Optimized: Gallery size limit per screen for IN, IE and RH series;
147 +1. Gallery size limitation per screen for IN, IE and RH series;
63 63  1. Other issues;
64 64  
65 65  (% class="wikigeneratedid" %)
... ... @@ -152,7 +152,6 @@
152 152  (% class="wikigeneratedid" %)
153 153  **New drive**
154 154  
155 -
156 156  1. Winding Machine MODBUS RTU Winder;
157 157  1. KEYENCE EtherNet/IP (KV-8000);
158 158  1. KEYENCE EtherNet/IP (KV-X310);
... ... @@ -183,7 +183,6 @@
183 183  (% class="wikigeneratedid" %)
184 184  **New models**
185 185  
186 -
187 187  1. GB series: GB3041, GB3070, GB3101, GB8041, GB8070-H, GB8101;
188 188  1. ig series: PI9102ig, PI9121ig, PI9150ig, PI9151ig;
189 189  1. WP series: WP2070, WP2071, WP3070, WP3071;
... ... @@ -964,7 +964,7 @@
964 964  
965 965  == V8.2.95_D20220928 ==
966 966  
967 -* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220928.zip]]
1050 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.2.95.22092802.zip]]
968 968  
969 969  (% class="wikigeneratedid" id="HBugsfixed" %)
970 970  **Bugs fixed**
... ... @@ -1328,5 +1328,6 @@
1328 1328  
1329 1329  = **4 StartupLogoTool** =
1330 1330  
1414 +* V3.0.24: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/StartupLogoTool%20v3.0.24.zip]] (Support RH series)
1331 1331  * V3.0.19: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/StartupLogoTool%20V3.0.19.zip]]
1332 1332  * old version: [[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]