... ... @@ -1,7 +1,8 @@
1 -1. (((
1 +(((
2 2  = **1 PIStudio** =
3 3  )))
4 -1. (((
4 +
5 +(((
5 5  == **V10.5.45.25102301(PI9000ig, RL, RH, WP)** ==
6 6  )))
7 7  
... ... @@ -18,48 +18,43 @@
18 18  1. Slow response of alarm record and address monitoring table, and stuck when opening the project;
19 19  1. LREAL data type cannot be read and written;
20 20  1. The overlapping screen cannot be set when the sub-screen is selected in screen;
21 -1. Software crash caused by too many project tag and alarm points;
22 -1. The encoding method cannot be selected when recording string data;
22 +1. The encoding method options for string type data in Data record;
23 23  1. Communication failure on Ethernet2 of HMI when using IP address from different Subnets for Ethernet1 and Ethernet2.
24 24  1. The addresses of X and Y are inconsistent in XY trend chart,;
25 -1. The address monitor is limited to one text address.
26 26  1. Object lock cannot be an index address;
27 -1. Choppy display from the camera;
28 -1. Logo display issue during IN, IE series upgrade;
26 +1. Lagging display of camera;
27 +1. Stuck on logo issue during IN, IE series upgrade;
29 29  1. The IN series HMI do not support the mouse style configuration;
30 30  1. Failure to download projects to IN series HMI ;
31 31  1. PDF prompts display abnormal;
32 32  1. CAN port configuration communication error;
33 33  1. When RH device uses 4K resolution, the fonts of message prompt, background, etc. are too small;
34 -1. Fixed:The issue of translator multi-language;
33 +1. The issue of translator multi-language;
35 35  1. Invalid address mapping;
36 36  1. The advanced configuration effect of device search, device management and cloud management download project not match the expected results;
37 -1. RH-00 communication port configuration does not have network port2 configuration ;
36 +1. RH-00 communication configuration does not have ETH2 configuration;
38 38  1. The ig model system keyboard is not working;
39 -1. Optimized: Remote cloud and pass-through;
40 -1. Optimized: Ig, RH series vertical screen mouse movement and touch;
41 -1. Optimization: 4.3-inch HMI vertical screen background display effect;
42 -1. Fixed:Issue of Siemens S7-1200 DBS register reads and writes less than half, need to check the ”Read Double Bytes”;
43 -1. The issue of OPCUA client reads and writes strings, if the new string is shorter than the old one, the end of the old string will be remained;
44 -1. When the recipe in the JUNCAUTO protocol is too large, the address will be clean and overwrite the data in low addresses;
45 -1. The issue with a bit in the LX5V word;
46 -1. OPCUA Client cannot connect to the server configured with authentication;
47 -1. OPCUA Client cannot reconnect normally after unplugging/plugging the network cable;
38 +1. The ig, RH series vertical screen mouse movement and touch optimized;
39 +1. 4.3-inch HMI vertical screen background display effect;
40 +1. Issue of Siemens S7-1200 DBS register reads and writes less than half, need to check the ”Read DWord” option;
41 +1. OPC UA Client reads and writes strings issue, if the new string is shorter than the old one, the end of the old string will be remained;
42 +1. If using too many element in recipe for JUNCAUTO protocol, the address will be clean and overwrite the data in low addresses;
43 +1. Write LX5V bit-in-word;
44 +1. OPC UA Client cannot connect to the server configured with authentication;
45 +1. OPC UA Client cannot reconnect normally after unplugging/plugging the network cable;
48 48  1. Changing communication methods in the background is invalid;
49 49  1. Set user permissions on the screen, but the register cannot jump to this screen;
50 -1. The issue of abnormal using indirect pictures on sub-screen;
48 +1. The issue of abnormal using indirect screen on sub-screen;
51 51  1. Abnormal display of the bar graph ;
52 52  1. The RH series cannot use the CODESYS protocol;
53 53  1. When the simulator's print object is set to screenshot mode, the screen cannot be switched after a screenshot.
54 -1. Operation records do not support multi-variable;
52 +1. Operation records do not support text variable insert;
55 55  1. Object or font shrinking when moving numeric object;
56 -1. The issue with quotation marks in recipe data after export/import on the 9000ig HMI;
57 -1. IN1072 cannot communicate with Siemens s7-200smart;
58 58  1. CODESYS V3 protocol cannot read the Unicode string of LX6C (WSTRING);
59 -1. The issue with the union in Omron;
55 +1. The issue with the UNION type data in Omron;
60 60  1. Communication failure after the end of VPN pass-through, ;
61 61  1. Communication failure between Keyence KV series protocol and 9000ig series;
62 -1. Optimized: Gallery size limit per screen for IN, IE and RH series;
58 +1. Gallery size limitation per screen for IN, IE and RH series;
63 63  1. Other issues;
64 64  
65 65  (% class="wikigeneratedid" %)
... ... @@ -152,7 +152,6 @@
152 152  (% class="wikigeneratedid" %)
153 153  **New drive**
154 154  
155 -
156 156  1. Winding Machine MODBUS RTU Winder;
157 157  1. KEYENCE EtherNet/IP (KV-8000);
158 158  1. KEYENCE EtherNet/IP (KV-X310);
... ... @@ -183,7 +183,6 @@
183 183  (% class="wikigeneratedid" %)
184 184  **New models**
185 185  
186 -
187 187  1. GB series: GB3041, GB3070, GB3101, GB8041, GB8070-H, GB8101;
188 188  1. ig series: PI9102ig, PI9121ig, PI9150ig, PI9151ig;
189 189  1. WP series: WP2070, WP2071, WP3070, WP3071;