Changes for page 3 Software

Last modified by Jett on 2025/03/13 14:13

From version 7.1
edited by Hunter
on 2022/07/29 14:41
Change comment: Renamed from xwiki:PIStudio.5 Software.WebHome
To version 11.1
edited by Stone Wu
on 2022/08/01 17:09
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -5 Software
1 +3 Software
Parent
... ... @@ -1,1 +1,1 @@
1 -PIStudio.WebHome
1 +PIStudio.Download.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.Stone
Content
... ... @@ -1,404 +1,285 @@
1 -= **PIStudio Release Build VER:R05R998_V8.2.62_D20220625** =
1 += **1 PIStudio** =
2 2  
3 -(% class="wikigeneratedid" %)
4 -**Official Website:**
3 +== V8.2.62_D20220625 ==
5 5  
6 -(% class="wikigeneratedid" %)
7 -**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220625.zip]]**
5 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220625.zip]]
6 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/1kJuuzxjPj5mZmeazhGxrs3lGyMceqmYj/view?usp=sharing]]
8 8  
9 -**Google Drive:**
8 +(% class="wikigeneratedid" id="HBugsfixed" %)
9 +**Bugs fixed**
10 10  
11 -**[[Download Link>>https://drive.google.com/file/d/1kJuuzxjPj5mZmeazhGxrs3lGyMceqmYj/view?usp=sharing]]**
11 +(% class="wikigeneratedid" id="HPCSoftware" %)
12 +PC Software
12 12  
13 -== **Bugs Fixed** ==
14 +1. Cloud.xml does not exist in the project file of 8000 series and cannot access cloud;
15 +1. Lua prompting error when double click the project path of General series in Screen Management;
16 +1. The cursor moving into the area of background script will be disappeared;
17 +1. After the Lua script is changed, it is not compiled, and there is no prompt when clicking offline simulation;
18 +1. DLView fails to import excel files;
19 +1. There is an abnormality when creating image files into Udisk;
20 +1. Orientation options missing for Slide switch;
21 +1. COM3 Configuration missing for following models: 3070i-A and 3102i-A;
22 +1. When the download tool downloads the project, it does not prompt when the file does not exist;
23 +1. SD Card option missing for following models: 3070i-A, 3102i-A, 3070i-C, 3102i-C;
24 +1. Some of the same font size, font style is different when the font size is displayed abnormally;
25 +1. Optimize the built-in screen No.1008, add Time and Date objects;
26 +1. Optimize the remote download;
27 +1. Optimize the U disk upgrade function;
28 +1. Prompt when the downloads a file with a long path;
29 +1. The ig series vertical screen option is available now;
14 14  
15 -=== **PC Software** ===
31 +(% class="wikigeneratedid" id="HHMIApplication" %)
32 +HMI Application
16 16  
17 -A) Cloud.xml does not exist in the project file of 8000 series and cannot access cloud;
34 +1. The i series freezes with HSW24 soft reboot;
35 +1. Debugging window cannot be closed on the ig monitoring page;
36 +1. Abnormal record time of ig Data record;
37 +1. The ig series abnormal ethernet communication;
38 +1. The register for network status HSW850 abnormal value;
39 +1. Lua we_bas_getstring script function execution error;
40 +1. The video title with English brackets cannot be played;
41 +1. Touch screen will lead to HMI freezes when keyboard input and cursor is enabled;
42 +1. Logo failed download for PI8150ig (before the firmware version 0313);
43 +1. After PI8000 series remote download PLC program, PLC cannot communicate;
44 +1. PI8000 series and ig series online V-NET but cannot remote control;
45 +1. Background Ethernet static IP configuration is not saved;
46 +1. The ig series WVPN remote pass through fails;
47 +1. Lua timer does not perform timing operations according to the interval;
18 18  
19 -B) Lua prompting error when double click the project path of General series in Screen Management;
49 +(% class="wikigeneratedid" id="HDriverProtocol" %)
50 +Driver Protocol
20 20  
21 -C) The cursor moving into the area of background script will be disappeared;
52 +1. PI8000ig and Yudian sensor cannot communicate;
53 +1. Modify the name of the Wecon LX6V protocol, the old version project must be re-selected;
54 +1. The following serial port protocols have intermittent communication timeout issue: Siemens S7-200 smart, modbus, INVT, etc.
55 +1. Taian AP200 C register can not read the value
22 22  
23 -D) After the Lua script is changed, it is not compiled, and there is no prompt when clicking offline simulation;
57 +(% class="wikigeneratedid" id="HNewfunctions" %)
58 +**New functions**
24 24  
25 -E) DLView fails to import excel files;
60 +(% class="wikigeneratedid" id="HPCSoftware-1" %)
61 +PC Software
26 26  
27 -F) There is an abnormality when creating image files into Udisk;
63 +1. VB script customize naming function;
64 +1. PI Suite toolkit;
65 +1. System upgrade function;
66 +1. PIRecordUpload has added User permission function;
67 +1. Cloud function of 8000 and 9000 series;
28 28  
29 -G) Orientation options missing for Slide switch;
69 +(% class="wikigeneratedid" id="HHMIApplication-1" %)
70 +HMI Application
30 30  
31 -H) COM3 Configuration missing for following models: 3070i-A and 3102i-A;
32 -
33 -I) When the download tool downloads the project, it does not prompt when the file does not exist;
34 -
35 -J) SD Card option missing for following models: 3070i-A, 3102i-A, 3070i-C, 3102i-C;
36 -
37 -K) Some of the same font size, font style is different when the font size is displayed abnormally;
38 -
39 -L) Optimize the built-in screen No.1008, add Time and Date objects;
40 -
41 -M) Optimize the remote download;
42 -
43 -N) Optimize the U disk upgrade function;
44 -
45 -O) Prompt when the downloads a file with a long path;
46 -
47 -P) The ig series vertical screen option is available now;
48 -
49 -=== **HMI Application** ===
50 -
51 -A) The i series freezes with HSW24 soft reboot;
52 -
53 -B) Debugging window cannot be closed on the ig monitoring page;
54 -
55 -C) Abnormal record time of ig Data record;
56 -
57 -D) The ig series abnormal ethernet communication;
58 -
59 -E)The register for network status HSW850 abnormal value;
60 -
61 -F) Lua we_bas_getstring script function execution error;
62 -
63 -G)The video title with English brackets cannot be played;
64 -
65 -H)Touch screen will lead to HMI freezes when keyboard input and cursor is enabled;
66 -
67 -I) Logo failed download for PI8150ig (before the firmware version 0313);
68 -
69 -J) After PI8000 series remote download PLC program, PLC cannot communicate;
70 -
71 -L) PI8000 series and ig series online V-NET but cannot remote control;
72 -
73 -M) Background Ethernet static IP configuration is not saved;
74 -
75 -N) The ig series WVPN remote pass through fails;
76 -
77 -O)Lua timer does not perform timing operations according to the interval;
78 -
79 -=== **Driver Protocol** ===
80 -
81 -A) PI8000ig and Yudian sensor cannot communicate;
82 -
83 -B) Modify the name of the Wecon LX6V protocol, the old version project must be re-selected;
84 -
85 -C)The following serial port protocols have intermittent communication timeout issue: Siemens S7-200 smart, modbus, INVT, etc.
86 -
87 -D)Taian AP200 C register can not read the value
88 -
89 -== **New Functions Added** ==
90 -
91 -=== **PC Software** ===
92 -
93 -A) VB script customize naming function;
94 -
95 -B) PI Suite toolkit;
96 -
97 -C) System upgrade function;
98 -
99 -D) PIRecordUpload has added User permission function;
100 -
101 -E) Cloud function of 8000 and 9000 series;
102 -
103 -=== **HMI Application** ===
104 -
105 105  The following function is only available for ig series:
106 106  
107 -A) Slider of History trend chart can set the color and transparency;
74 +1. Slider of History trend chart can set the color and transparency;
75 +1. Continuous read and write addresses in Lua script;
76 +1. Built-in Lua extension module;
77 +1. Display network camera on HMI screen for 8150ig;
78 +1. Vertical Display;
79 +1. The priority settings of Cloud connection method from backstage configuration;
80 +1. Lua script supports https protocol now;
81 +1. UDisk Download project prohibit upload function;
82 +1. Lua script luasqlite operation;
83 +1. The following function is only available for i,ie,ig series and HMI+ system:
84 +1. All series remove the restriction of special machine code;
85 +1. Recipe 64-bit floating point number data format;
86 +1. UDisk Pop-Up function;
87 +1. Interconversion between GB2312 and UTF-8 encoding;
88 +1. UDisk download PLC multi-file function;
89 +1. Modifitable datetime prohibited;
90 +1. Color configuration of Line object;
108 108  
109 -B) Continuous read and write addresses in Lua script;
92 +(% class="wikigeneratedid" id="HDriverProtocol-1" %)
93 +Driver Protocol
110 110  
111 -C) Built-in Lua extension module;
95 +1. Inovance H3U Ethernet;
96 +1. Rockwell micro850 Ethernet/IP Free Tags;
97 +1. Wecon LX6V Free Tags;
112 112  
113 -D) Display network camera on HMI screen for 8150ig;
99 +(% class="wikigeneratedid" id="HNewmodels" %)
100 +**New models**
114 114  
115 -E) Vertical Display;
102 +1. The i series: 3070i-A, 3102i-A, 3070i-C, 3102i-C, 3070i-2S, 3102i-2S
103 +1. The ie series: 3043ie-T
104 +1. The ig series: 8150ig
116 116  
117 -F) The priority settings of Cloud connection method from backstage configuration;
118 -
119 -G) Lua script supports https protocol now;
120 -
121 -H) UDisk Download project prohibit upload function;
122 -
123 -I) Lua script luasqlite operation;
124 -
125 -The following function is only available for i,ie,ig series and HMI+ system:
126 -
127 -J)All series remove the restriction of special machine code;
128 -
129 -K) Recipe 64-bit floating point number data format;
130 -
131 -L) UDisk Pop-Up function;
132 -
133 -M) Interconversion between GB2312 and UTF-8 encoding;
134 -
135 -N) UDisk download PLC multi-file function;
136 -
137 -O) Modifitable datetime prohibited;
138 -
139 -P) Color configuration of Line object;
140 -
141 -=== **Driver Protocol** ===
142 -
143 -A Inovance H3U Ethernet;
144 -
145 -B Rockwell micro850 Ethernet/IP Free Tags;
146 -
147 -C Wecon LX6V Free Tags;
148 -
149 -== **New Models** ==
150 -
151 -(1)The i series: 3070i-A, 3102i-A, 3070i-C, 3102i-C, 3070i-2S, 3102i-2S
152 -
153 -(2)The ie series: 3043ie-T
154 -
155 -(3)The ig series: 8150ig
156 -
106 +(% class="box infomessage" %)
107 +(((
157 157  ✎Note:
158 158  
159 -1)To use the new functions avaiable from new version, the project needs to be downloaded twice;
110 +* To use the new functions avaiable from new version, the project needs to be downloaded twice;
111 +* After the wifi module (version V1.1) of 3070ig is soft restarted, if the wifi is not recognized from background interface, please repower to recover it;
112 +)))
160 160  
161 -2)After the wifi module (version V1.1) of 3070ig is soft restarted, if the wifi is not recognized from background interface, please repower to recover it;
114 +== V7.2.198_D20211210 ==
162 162  
163 -= **PIStudio Release Build VER:R05R998_V7.2.198_D20211210** =
116 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]]
117 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/1lRfgoOwAs7lgL4b-ZdVUvE6itHWCpfd5/view?usp=sharing]]
164 164  
165 -(% class="wikigeneratedid" %)
166 -**Official Website:**
119 +(% class="wikigeneratedid" id="HBugsfixed-1" %)
120 +**Bugs fixed**
167 167  
168 -(% class="wikigeneratedid" %)
169 -**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]]**
122 +(% class="wikigeneratedid" id="HPCSoftware-2" %)
123 +PC Software
170 170  
171 -**Google Drive:**
125 +* Optimize the display style of text objects;
126 +* Optimize Lua script file size limitation to 512KB;
127 +* Optimize the import of text library and the limitation to 2000;
128 +* Protocol driver names standardized;
129 +* Font size is open to 512;
130 +* Lua script debugging window can be configured as enabled or not in Project Settings;
131 +* Optimize the font display of Runbar;
132 +* Optimized the forced backup function of project file, now you can click the cancel button to not backup;
133 +* Optimized and adjusted the default size of the password keyboard screen of newly-created projects;
134 +* Wrong display range of the History trend chart;
135 +* The font display of Drop-down List on PC is different from the actual screen;
136 +* Software crash caused by deleting the Address Library name;
137 +* General Series SMS protocol cannot be selected;
172 172  
173 -**[[Download Link>>https://drive.google.com/file/d/1lRfgoOwAs7lgL4b-ZdVUvE6itHWCpfd5/view?usp=sharing]]**
139 +(% class="wikigeneratedid" id="HHMIApplication-2" %)
140 +HMI Application
174 174  
175 -== **Bugs Fixed** ==
142 +* Multi-Language display of text fonts;
143 +* Password keyboard input to display the plain text first and then the * sign;
144 +* Prompt display of Screen Lock for ie and ig;
145 +* Auto refresh of Data Record;
176 176  
177 -=== **PC Software** ===
147 +(% class="wikigeneratedid" id="HDriverProtocol-2" %)
148 +Driver Protocol
178 178  
179 -A) Optimize the display style of text objects;
150 +* Communication cannot be performed after entering the backstage project;
151 +* Stuck screen problem caused by the protocol IEC60870-104 Client;
180 180  
181 -B) Optimize Lua script file size limitation to 512KB;
153 +(% class="wikigeneratedid" id="HNewfunctions-1" %)
154 +**New functions**
182 182  
183 -C) Optimize the import of text library and the limitation to 2000;
156 +(% class="wikigeneratedid" id="HPCSoftware-3" %)
157 +PC Software
184 184  
185 -D) Protocol driver names standardized;
159 +* New ie series model: 3035ie;
160 +* New ig series models: 3070ig, 3102ig;
161 +* License agreement for the software installation setup process;
162 +* Object Lock/Unlock function (Pushpin);
163 +* Lua Editor to highlight the same content of the selected text;
164 +* Font style settings of the Runbar and chart type objects;
165 +* Software installation package VC 2017 runtime library;
186 186  
187 -E) Font size is open to 512;
167 +(% class="wikigeneratedid" id="HHMIApplication-3" %)
168 +HMI Application
188 188  
189 -F) Lua script debugging window can be configured as enabled or not in Project Settings;
170 +* Recipe address discontinuous address setting;
171 +* Trim 0 display setting for numeric input;
172 +* Address Mapping continuous writing settings;
173 +* Screensaver function;
174 +* Multi-Link function (not supported by ie and ig series);
175 +* Traditional recipe function is only applicable to the LEVI2PI project that uses the Recipe function;
176 +* Disc Record Chart;
177 +* Lua script weather forecast function interfaces;
178 +* The ie series supports the barcode scanner;
190 190  
191 -G) Optimize the font display of Runbar;
180 +(% class="wikigeneratedid" id="HDriverProtocol-3" %)
181 +Driver Protocol
192 192  
193 -H) Optimized the forced backup function of project file, now you can click the cancel button to not backup;
183 +* Koyo Modbus RTU;
184 +* ASK series;
185 +* Anda inverter;
186 +* Optimize the barcode scanner protocol;
194 194  
195 -I) Optimized and adjusted the default size of the password keyboard screen of newly-created projects;
188 +== V7.1.117_D20210320 ==
196 196  
197 -J) Wrong display range of the History trend chart;
190 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20210320.zip]]
191 +* Dropbox: [[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=PIStudio20210320.zip&subfolder_nav_tracking=1]]
198 198  
199 -K) The font display of Drop-down List on PC is different from the actual screen;
193 +(% class="wikigeneratedid" id="HBugsfixed-2" %)
194 +**Bugs fixed**
200 200  
201 -L) Software crash caused by deleting the Address Library name;
196 +(% class="wikigeneratedid" id="HPCSoftware-4" %)
197 +PC Software
202 202  
203 -M) General Series SMS protocol cannot be selected;
199 +* Fix the crash problem of the software;
200 +* Renew the wiring diagram and pin definition diagram;
201 +* After the address is annotated, still able to communicate in Lua script;
202 +* Ethernet download optimization;
203 +* The project folder contains special language characters(except Chinese and English), errors in compiling Lua file and project, failed to download the project;
204 +* Use some fonts will cause software crash when compiling the project;
204 204  
205 -=== **HMI Application** ===
206 +(% class="wikigeneratedid" id="HHMIApplication-4" %)
207 +HMI Application
206 206  
207 -A) Multi-Language display of text fonts;
209 +* Occasionally occur stuck logo problem after enable the Index of Recipe function;
210 +* B) Frequently screen switching might have a little chance cause stuck problem if there exist many table objects on the screen;
211 +* There is a little chance cause the stuck problem if use the script;
212 +* The stuck problem if use User permission;
213 +* The stuck problem when Data record upload;
214 +* There is a little chance to jump to the test interface after restart;
215 +* After the backlight is off, there is a small chance that the screen will display abnormal;
216 +* Video play cause stuck problem of General series 9150;
217 +* When the HMI just turned on, Recipe Display on the main screen is displayed as NULL;
218 +* Optimize Lua built-in library and file read/write functions;
219 +* The label of the operation value in the Operation record is displayed abnormal;
220 +* The length of channel name for Data record exceeds 32 bytes, will cause failed recording;
221 +* After entering the installment password, restart immediately, would require entering the password again;
208 208  
209 -B) Password keyboard input to display the plain text first and then the * sign;
223 +(% class="wikigeneratedid" id="HDriverProtocol-4" %)
224 +Driver Protocol
210 210  
211 -C) Prompt display of Screen Lock for ie and ig;
226 +* Frequently screen switching and there are many external addresses on the screen, which might have a little chance cause a stuck problem; 
227 +* Ethernet free tags may cause touch problem with no response;
228 +* Ethernet free tags occur error in compiling the project;
229 +* The input/output terminals of communication with MIKOM PLC are abnormal;
230 +* The reading information from scanner will not display if it exceeds 128 characters;
231 +* Failed to communicate with the OMRON NX/NJ PLC communication after power-on the screen and then power on the PLC.
232 +* When HMI+ is just turned on, the Ethernet communication prompts timeout;
233 +* When communicate with Siemens new protocol, will let the HMI stuck on LOGO screen;
212 212  
213 -D) Auto refresh of Data Record;
235 +(% class="wikigeneratedid" id="HNewfunctions-2" %)
236 +**New functions**
214 214  
215 -=== **Driver Protocol** ===
238 +(% class="wikigeneratedid" id="HPCSoftware-5" %)
239 +PC Software
216 216  
217 -A) Communication cannot be performed after entering the backstage project;
241 +* New ie series: 3043ie, 3043ieS, 3070ie, 3102ie;
242 +* Industry purpose-designated models: ie series 3070ind, 3102ind, I series 3070ind-n;
243 +* Import and export function for Gallery file ( .blb or .plb format);
218 218  
219 -B) Stuck screen problem caused by the protocol IEC60870-104 Client;
245 +(% class="wikigeneratedid" id="HHMIApplication-5" %)
246 +HMI Application
220 220  
221 -== **New Functions Added** ==
248 +* VNC LAN monitoring function ( require i series and PI+ models with Ethernet port and customized, the -O model in General series still use HMI Monitor System)
249 +* Resource report function to count the total memory used by the current screen;
250 +* Message prompt list (timeout , message , only available for ie series);
251 +* Timer and Trigger function in Lua script (only available for ie series);
252 +* Lua custom object, Lua table drawing, Lua curve drawing (only available for ie series);
253 +* Continuous input function of numeric and character object;
254 +* 4 Macro script functions involving file operations, FileCmpDir(), MyDeleteFile(), WriteWordToFile(), ReadWordFormFile();
255 +* The backstage interface can upgrade PLC program to support 5VPLC program download (only available for 3000i and PI+ series);
222 222  
223 -=== **PC Software** ===
257 +(% class="wikigeneratedid" id="HDriverProtocol-5" %)
258 +Driver Protocol
224 224  
225 -A) New ie series model: 3035ie;
260 +* Keyence KV series;
226 226  
227 -B) New ig series models: 3070ig, 3102ig;
262 +== Notification of PI+ ==
228 228  
229 -C) License agreement for the software installation setup process;
264 +* [[Download Link>>url:https://drive.google.com/file/d/1UMb8YGc5lLSfoF_UHD5A4HwE_HKd-Qg7/view?usp=sharing]]
230 230  
231 -D) Object Lock/Unlock function (Pushpin);
266 += **2 Levi2PI** =
232 232  
233 -E) Lua Editor to highlight the same content of the selected text;
268 +== V4.3.8 ==
234 234  
235 -F) Font style settings of the Runbar and chart type objects;
270 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Wecon%20LEVI2PI.zip]]
271 +* Dropbox: [[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=Wecon+LEVI2PI.zip&subfolder_nav_tracking=1]]
236 236  
237 -G) Software installation package VC 2017 runtime library;
273 +== V4.5.6(Test Version) ==
238 238  
239 -=== **HMI Application** ===
275 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/10Ay8dr7MK6CCpMIKEmKITG3DGipffJsI/view?usp=sharing]]
240 240  
241 -A) Recipe address discontinuous address setting;
277 += **3 HMI Monitor System** =
242 242  
243 -B) Trim 0 display setting for numeric input;
279 +== VER: 20210317 ==
244 244  
245 -C) Address Mapping continuous writing settings;
281 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/1RA3ui3jTCKtQTCLySjD4Qi7Ut58EYYD1/view?usp=sharing]]
246 246  
247 -D) Screensaver function;
283 += **4 Logo Making Tool** =
248 248  
249 -E) Multi-Link function (not supported by ie and ig series);
250 -
251 -F) Traditional recipe function is only applicable to the LEVI2PI project that uses the Recipe function;
252 -
253 -G) Disc Record Chart;
254 -
255 -H) Lua script weather forecast function interfaces;
256 -
257 -I) The ie series supports the barcode scanner;
258 -
259 -=== **Driver Protocol** ===
260 -
261 -A) Koyo Modbus RTU;
262 -
263 -B) ASK series;
264 -
265 -C) Anda inverter;
266 -
267 -D) Optimize the barcode scanner protocol;
268 -
269 -= **PIStudio Release Build VER:R05R998_V7.1.117_D20210320** =
270 -
271 -**Official Website:**
272 -
273 -**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20210320.zip]]**
274 -
275 -**Dropbox:**
276 -
277 -**[[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=PIStudio20210320.zip&subfolder_nav_tracking=1]]**
278 -
279 -== **Bugs Fixed** ==
280 -
281 -=== **PC Software** ===
282 -
283 -A) Fix the crash problem of the software;
284 -
285 -B) Renew the wiring diagram and pin definition diagram;
286 -
287 -C) After the address is annotated, still able to communicate in Lua script;
288 -
289 -D) Ethernet download optimization;
290 -
291 -E) The project folder contains special language characters(except Chinese and English), errors in compiling Lua file and project, failed to download the project;
292 -
293 -F) Use some fonts will cause software crash when compiling the project;
294 -
295 -=== **HMI Application** ===
296 -
297 -A) Occasionally occur stuck logo problem after enable the Index of Recipe function;
298 -
299 -B) Frequently screen switching might have a little chance cause stuck problem if there exist many table objects on the screen;
300 -
301 -C) There is a little chance cause the stuck problem if use the script;
302 -
303 -D) The stuck problem if use User permission;
304 -
305 -E) The stuck problem when Data record upload;
306 -
307 -F) There is a little chance to jump to the test interface after restart;
308 -
309 -G) After the backlight is off, there is a small chance that the screen will display abnormal;
310 -
311 -H) Video play cause stuck problem of General series 9150;
312 -
313 -I) When the HMI just turned on, Recipe Display on the main screen is displayed as NULL;
314 -
315 -J) Optimize Lua built-in library and file read/write functions;
316 -
317 -K) The label of the operation value in the Operation record is displayed abnormal;
318 -
319 -L) The length of channel name for Data record exceeds 32 bytes, will cause failed recording;
320 -
321 -M) After entering the installment password, restart immediately, would require entering the password again;
322 -
323 -=== **Driver Protocol** ===
324 -
325 -A) Frequently screen switching and there are many external addresses on the screen, which might have a little chance cause a stuck problem; 
326 -
327 -B) Ethernet free tags may cause touch problem with no response;
328 -
329 -C) Ethernet free tags occur error in compiling the project;
330 -
331 -D) The input/output terminals of communication with MIKOM PLC are abnormal;
332 -
333 -E) The reading information from scanner will not display if it exceeds 128 characters;
334 -
335 -F) Failed to communicate with the OMRON NX/NJ PLC communication after power-on the screen and then power on the PLC.
336 -
337 -G) When HMI+ is just turned on, the Ethernet communication prompts timeout;
338 -
339 -H) When communicate with Siemens new protocol, will let the HMI stuck on LOGO screen;
340 -
341 -== **New Functions Added** ==
342 -
343 -=== **PC Software** ===
344 -
345 -A) New ie series: 3043ie, 3043ieS, 3070ie, 3102ie;
346 -
347 -B) Industry purpose-designated models: ie series 3070ind, 3102ind, I series 3070ind-n;
348 -
349 -C) Import and export function for Gallery file ( .blb or .plb format);
350 -
351 -=== **HMI Application** ===
352 -
353 -A) VNC LAN monitoring function ( require i series and PI+ models with Ethernet port and customized, the -O model in General series still use HMI Monitor System)
354 -
355 -B) Resource report function to count the total memory used by the current screen;
356 -
357 -C) Message prompt list (timeout , message , only available for ie series);
358 -
359 -D) Timer and Trigger function in Lua script (only available for ie series);
360 -
361 -E) Lua custom object, Lua table drawing, Lua curve drawing (only available for ie series);
362 -
363 -F) Continuous input function of numeric and character object;
364 -
365 -G) 4 Macro script functions involving file operations, FileCmpDir(), MyDeleteFile(), WriteWordToFile(), ReadWordFormFile();
366 -
367 -H) The backstage interface can upgrade PLC program to support 5VPLC program download (only available for 3000i and PI+ series);
368 -
369 -== **Driver Protocol** ==
370 -
371 -A) Keyence KV series;
372 -
373 -== **Notification of PI+** ==
374 -
375 -**[[Download Link>>url:https://drive.google.com/file/d/1UMb8YGc5lLSfoF_UHD5A4HwE_HKd-Qg7/view?usp=sharing]]**
376 -
377 -= **Levi2PI V4.3.8** =
378 -
379 -**Official Website:**
380 -
381 -**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/Wecon%20LEVI2PI.zip]]**
382 -
383 -**Dropbox:**
384 -
385 -**[[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=Wecon+LEVI2PI.zip&subfolder_nav_tracking=1]]**
386 -
387 -= **Levi2PI V4.5.6(Test Version)** =
388 -
389 -**Google Drive**
390 -
391 -**[[Download Link>>https://drive.google.com/file/d/10Ay8dr7MK6CCpMIKEmKITG3DGipffJsI/view?usp=sharing]]**
392 -
393 -= **HMI Monitor System20210317** =
394 -
395 -**Google Drive:**
396 -
397 -**[[Download Link>>https://drive.google.com/file/d/1RA3ui3jTCKtQTCLySjD4Qi7Ut58EYYD1/view?usp=sharing]]**
398 -
399 -
400 -= **6 Logo Making Tool** =
401 -
402 -**Google Drive:**
403 -
404 -**[[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]**
285 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]