Changes for page 3 Software
Last modified by Jett on 2025/03/13 14:13
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Stone - Content
-
... ... @@ -1,404 +1,285 @@ 1 -= **PIStudio Release Build VER:R05R998_V8.2.62_D20220625** =1 += **1 PIStudio** = 2 2 3 -(% class="wikigeneratedid" %) 4 -**Official Website:** 3 +== V8.2.62_D20220625 == 5 5 6 - (%class="wikigeneratedid" %)7 -* *[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220625.zip]]**5 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220625.zip]] 6 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/1kJuuzxjPj5mZmeazhGxrs3lGyMceqmYj/view?usp=sharing]] 8 8 9 -**Google Drive:** 8 +(% class="wikigeneratedid" id="HBugsfixed" %) 9 +**Bugs fixed** 10 10 11 -**[[Download Link>>https://drive.google.com/file/d/1kJuuzxjPj5mZmeazhGxrs3lGyMceqmYj/view?usp=sharing]]** 11 +(% class="wikigeneratedid" id="HPCSoftware" %) 12 +PC Software 12 12 13 -== **Bugs Fixed** == 14 +1. Cloud.xml does not exist in the project file of 8000 series and cannot access cloud; 15 +1. Lua prompting error when double click the project path of General series in Screen Management; 16 +1. The cursor moving into the area of background script will be disappeared; 17 +1. After the Lua script is changed, it is not compiled, and there is no prompt when clicking offline simulation; 18 +1. DLView fails to import excel files; 19 +1. There is an abnormality when creating image files into Udisk; 20 +1. Orientation options missing for Slide switch; 21 +1. COM3 Configuration missing for following models: 3070i-A and 3102i-A; 22 +1. When the download tool downloads the project, it does not prompt when the file does not exist; 23 +1. SD Card option missing for following models: 3070i-A, 3102i-A, 3070i-C, 3102i-C; 24 +1. Some of the same font size, font style is different when the font size is displayed abnormally; 25 +1. Optimize the built-in screen No.1008, add Time and Date objects; 26 +1. Optimize the remote download; 27 +1. Optimize the U disk upgrade function; 28 +1. Prompt when the downloads a file with a long path; 29 +1. The ig series vertical screen option is available now; 14 14 15 -=== **PC Software** === 31 +(% class="wikigeneratedid" id="HHMIApplication" %) 32 +HMI Application 16 16 17 -A) Cloud.xml does not exist in the project file of 8000 series and cannot access cloud; 34 +1. The i series freezes with HSW24 soft reboot; 35 +1. Debugging window cannot be closed on the ig monitoring page; 36 +1. Abnormal record time of ig Data record; 37 +1. The ig series abnormal ethernet communication; 38 +1. The register for network status HSW850 abnormal value; 39 +1. Lua we_bas_getstring script function execution error; 40 +1. The video title with English brackets cannot be played; 41 +1. Touch screen will lead to HMI freezes when keyboard input and cursor is enabled; 42 +1. Logo failed download for PI8150ig (before the firmware version 0313); 43 +1. After PI8000 series remote download PLC program, PLC cannot communicate; 44 +1. PI8000 series and ig series online V-NET but cannot remote control; 45 +1. Background Ethernet static IP configuration is not saved; 46 +1. The ig series WVPN remote pass through fails; 47 +1. Lua timer does not perform timing operations according to the interval; 18 18 19 -B) Lua prompting error when double click the project path of General series in Screen Management; 49 +(% class="wikigeneratedid" id="HDriverProtocol" %) 50 +Driver Protocol 20 20 21 -C) The cursor moving into the area of background script will be disappeared; 52 +1. PI8000ig and Yudian sensor cannot communicate; 53 +1. Modify the name of the Wecon LX6V protocol, the old version project must be re-selected; 54 +1. The following serial port protocols have intermittent communication timeout issue: Siemens S7-200 smart, modbus, INVT, etc. 55 +1. Taian AP200 C register can not read the value 22 22 23 -D) After the Lua script is changed, it is not compiled, and there is no prompt when clicking offline simulation; 57 +(% class="wikigeneratedid" id="HNewfunctions" %) 58 +**New functions** 24 24 25 -E) DLView fails to import excel files; 60 +(% class="wikigeneratedid" id="HPCSoftware-1" %) 61 +PC Software 26 26 27 -F) There is an abnormality when creating image files into Udisk; 63 +1. VB script customize naming function; 64 +1. PI Suite toolkit; 65 +1. System upgrade function; 66 +1. PIRecordUpload has added User permission function; 67 +1. Cloud function of 8000 and 9000 series; 28 28 29 -G) Orientation options missing for Slide switch; 69 +(% class="wikigeneratedid" id="HHMIApplication-1" %) 70 +HMI Application 30 30 31 -H) COM3 Configuration missing for following models: 3070i-A and 3102i-A; 32 - 33 -I) When the download tool downloads the project, it does not prompt when the file does not exist; 34 - 35 -J) SD Card option missing for following models: 3070i-A, 3102i-A, 3070i-C, 3102i-C; 36 - 37 -K) Some of the same font size, font style is different when the font size is displayed abnormally; 38 - 39 -L) Optimize the built-in screen No.1008, add Time and Date objects; 40 - 41 -M) Optimize the remote download; 42 - 43 -N) Optimize the U disk upgrade function; 44 - 45 -O) Prompt when the downloads a file with a long path; 46 - 47 -P) The ig series vertical screen option is available now; 48 - 49 -=== **HMI Application** === 50 - 51 -A) The i series freezes with HSW24 soft reboot; 52 - 53 -B) Debugging window cannot be closed on the ig monitoring page; 54 - 55 -C) Abnormal record time of ig Data record; 56 - 57 -D) The ig series abnormal ethernet communication; 58 - 59 -E)The register for network status HSW850 abnormal value; 60 - 61 -F) Lua we_bas_getstring script function execution error; 62 - 63 -G)The video title with English brackets cannot be played; 64 - 65 -H)Touch screen will lead to HMI freezes when keyboard input and cursor is enabled; 66 - 67 -I) Logo failed download for PI8150ig (before the firmware version 0313); 68 - 69 -J) After PI8000 series remote download PLC program, PLC cannot communicate; 70 - 71 -L) PI8000 series and ig series online V-NET but cannot remote control; 72 - 73 -M) Background Ethernet static IP configuration is not saved; 74 - 75 -N) The ig series WVPN remote pass through fails; 76 - 77 -O)Lua timer does not perform timing operations according to the interval; 78 - 79 -=== **Driver Protocol** === 80 - 81 -A) PI8000ig and Yudian sensor cannot communicate; 82 - 83 -B) Modify the name of the Wecon LX6V protocol, the old version project must be re-selected; 84 - 85 -C)The following serial port protocols have intermittent communication timeout issue: Siemens S7-200 smart, modbus, INVT, etc. 86 - 87 -D)Taian AP200 C register can not read the value 88 - 89 -== **New Functions Added** == 90 - 91 -=== **PC Software** === 92 - 93 -A) VB script customize naming function; 94 - 95 -B) PI Suite toolkit; 96 - 97 -C) System upgrade function; 98 - 99 -D) PIRecordUpload has added User permission function; 100 - 101 -E) Cloud function of 8000 and 9000 series; 102 - 103 -=== **HMI Application** === 104 - 105 105 The following function is only available for ig series: 106 106 107 -A) Slider of History trend chart can set the color and transparency; 74 +1. Slider of History trend chart can set the color and transparency; 75 +1. Continuous read and write addresses in Lua script; 76 +1. Built-in Lua extension module; 77 +1. Display network camera on HMI screen for 8150ig; 78 +1. Vertical Display; 79 +1. The priority settings of Cloud connection method from backstage configuration; 80 +1. Lua script supports https protocol now; 81 +1. UDisk Download project prohibit upload function; 82 +1. Lua script luasqlite operation; 83 +1. The following function is only available for i,ie,ig series and HMI+ system: 84 +1. All series remove the restriction of special machine code; 85 +1. Recipe 64-bit floating point number data format; 86 +1. UDisk Pop-Up function; 87 +1. Interconversion between GB2312 and UTF-8 encoding; 88 +1. UDisk download PLC multi-file function; 89 +1. Modifitable datetime prohibited; 90 +1. Color configuration of Line object; 108 108 109 -B) Continuous read and write addresses in Lua script; 92 +(% class="wikigeneratedid" id="HDriverProtocol-1" %) 93 +Driver Protocol 110 110 111 -C) Built-in Lua extension module; 95 +1. Inovance H3U Ethernet; 96 +1. Rockwell micro850 Ethernet/IP Free Tags; 97 +1. Wecon LX6V Free Tags; 112 112 113 -D) Display network camera on HMI screen for 8150ig; 99 +(% class="wikigeneratedid" id="HNewmodels" %) 100 +**New models** 114 114 115 -E) Vertical Display; 102 +1. The i series: 3070i-A, 3102i-A, 3070i-C, 3102i-C, 3070i-2S, 3102i-2S 103 +1. The ie series: 3043ie-T 104 +1. The ig series: 8150ig 116 116 117 -F) The priority settings of Cloud connection method from backstage configuration; 118 - 119 -G) Lua script supports https protocol now; 120 - 121 -H) UDisk Download project prohibit upload function; 122 - 123 -I) Lua script luasqlite operation; 124 - 125 -The following function is only available for i,ie,ig series and HMI+ system: 126 - 127 -J)All series remove the restriction of special machine code; 128 - 129 -K) Recipe 64-bit floating point number data format; 130 - 131 -L) UDisk Pop-Up function; 132 - 133 -M) Interconversion between GB2312 and UTF-8 encoding; 134 - 135 -N) UDisk download PLC multi-file function; 136 - 137 -O) Modifitable datetime prohibited; 138 - 139 -P) Color configuration of Line object; 140 - 141 -=== **Driver Protocol** === 142 - 143 -A Inovance H3U Ethernet; 144 - 145 -B Rockwell micro850 Ethernet/IP Free Tags; 146 - 147 -C Wecon LX6V Free Tags; 148 - 149 -== **New Models** == 150 - 151 -(1)The i series: 3070i-A, 3102i-A, 3070i-C, 3102i-C, 3070i-2S, 3102i-2S 152 - 153 -(2)The ie series: 3043ie-T 154 - 155 -(3)The ig series: 8150ig 156 - 106 +(% class="box infomessage" %) 107 +((( 157 157 ✎Note: 158 158 159 -1)To use the new functions avaiable from new version, the project needs to be downloaded twice; 110 +* To use the new functions avaiable from new version, the project needs to be downloaded twice; 111 +* After the wifi module (version V1.1) of 3070ig is soft restarted, if the wifi is not recognized from background interface, please repower to recover it; 112 +))) 160 160 161 - 2)Afterthe wifi module (versionV1.1) of 3070igis soft restarted, if the wifi is not recognized from background interface, please repower to recover it;114 +== V7.2.198_D20211210 == 162 162 163 -= **PIStudio Release Build VER:R05R998_V7.2.198_D20211210** = 116 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]] 117 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/1lRfgoOwAs7lgL4b-ZdVUvE6itHWCpfd5/view?usp=sharing]] 164 164 165 -(% class="wikigeneratedid" %) 166 -** Official Website:**119 +(% class="wikigeneratedid" id="HBugsfixed-1" %) 120 +**Bugs fixed** 167 167 168 -(% class="wikigeneratedid" %) 169 - **[[DownloadLink>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]]**122 +(% class="wikigeneratedid" id="HPCSoftware-2" %) 123 +PC Software 170 170 171 -**Google Drive:** 125 +* Optimize the display style of text objects; 126 +* Optimize Lua script file size limitation to 512KB; 127 +* Optimize the import of text library and the limitation to 2000; 128 +* Protocol driver names standardized; 129 +* Font size is open to 512; 130 +* Lua script debugging window can be configured as enabled or not in Project Settings; 131 +* Optimize the font display of Runbar; 132 +* Optimized the forced backup function of project file, now you can click the cancel button to not backup; 133 +* Optimized and adjusted the default size of the password keyboard screen of newly-created projects; 134 +* Wrong display range of the History trend chart; 135 +* The font display of Drop-down List on PC is different from the actual screen; 136 +* Software crash caused by deleting the Address Library name; 137 +* General Series SMS protocol cannot be selected; 172 172 173 -**[[Download Link>>https://drive.google.com/file/d/1lRfgoOwAs7lgL4b-ZdVUvE6itHWCpfd5/view?usp=sharing]]** 139 +(% class="wikigeneratedid" id="HHMIApplication-2" %) 140 +HMI Application 174 174 175 -== **Bugs Fixed** == 142 +* Multi-Language display of text fonts; 143 +* Password keyboard input to display the plain text first and then the * sign; 144 +* Prompt display of Screen Lock for ie and ig; 145 +* Auto refresh of Data Record; 176 176 177 -=== **PC Software** === 147 +(% class="wikigeneratedid" id="HDriverProtocol-2" %) 148 +Driver Protocol 178 178 179 -A) Optimize the display style of text objects; 150 +* Communication cannot be performed after entering the backstage project; 151 +* Stuck screen problem caused by the protocol IEC60870-104 Client; 180 180 181 -B) Optimize Lua script file size limitation to 512KB; 153 +(% class="wikigeneratedid" id="HNewfunctions-1" %) 154 +**New functions** 182 182 183 -C) Optimize the import of text library and the limitation to 2000; 156 +(% class="wikigeneratedid" id="HPCSoftware-3" %) 157 +PC Software 184 184 185 -D) Protocol driver names standardized; 159 +* New ie series model: 3035ie; 160 +* New ig series models: 3070ig, 3102ig; 161 +* License agreement for the software installation setup process; 162 +* Object Lock/Unlock function (Pushpin); 163 +* Lua Editor to highlight the same content of the selected text; 164 +* Font style settings of the Runbar and chart type objects; 165 +* Software installation package VC 2017 runtime library; 186 186 187 -E) Font size is open to 512; 167 +(% class="wikigeneratedid" id="HHMIApplication-3" %) 168 +HMI Application 188 188 189 -F) Lua script debugging window can be configured as enabled or not in Project Settings; 170 +* Recipe address discontinuous address setting; 171 +* Trim 0 display setting for numeric input; 172 +* Address Mapping continuous writing settings; 173 +* Screensaver function; 174 +* Multi-Link function (not supported by ie and ig series); 175 +* Traditional recipe function is only applicable to the LEVI2PI project that uses the Recipe function; 176 +* Disc Record Chart; 177 +* Lua script weather forecast function interfaces; 178 +* The ie series supports the barcode scanner; 190 190 191 -G) Optimize the font display of Runbar; 180 +(% class="wikigeneratedid" id="HDriverProtocol-3" %) 181 +Driver Protocol 192 192 193 -H) Optimized the forced backup function of project file, now you can click the cancel button to not backup; 183 +* Koyo Modbus RTU; 184 +* ASK series; 185 +* Anda inverter; 186 +* Optimize the barcode scanner protocol; 194 194 195 - I)Optimizedand adjusted the default size of the password keyboard screen of newly-created projects;188 +== V7.1.117_D20210320 == 196 196 197 -J) Wrong display range of the History trend chart; 190 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20210320.zip]] 191 +* Dropbox: [[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=PIStudio20210320.zip&subfolder_nav_tracking=1]] 198 198 199 -K) The font display of Drop-down List on PC is different from the actual screen; 193 +(% class="wikigeneratedid" id="HBugsfixed-2" %) 194 +**Bugs fixed** 200 200 201 -L) Software crash caused by deleting the Address Library name; 196 +(% class="wikigeneratedid" id="HPCSoftware-4" %) 197 +PC Software 202 202 203 -M) General Series SMS protocol cannot be selected; 199 +* Fix the crash problem of the software; 200 +* Renew the wiring diagram and pin definition diagram; 201 +* After the address is annotated, still able to communicate in Lua script; 202 +* Ethernet download optimization; 203 +* The project folder contains special language characters(except Chinese and English), errors in compiling Lua file and project, failed to download the project; 204 +* Use some fonts will cause software crash when compiling the project; 204 204 205 -=== **HMI Application** === 206 +(% class="wikigeneratedid" id="HHMIApplication-4" %) 207 +HMI Application 206 206 207 -A) Multi-Language display of text fonts; 209 +* Occasionally occur stuck logo problem after enable the Index of Recipe function; 210 +* B) Frequently screen switching might have a little chance cause stuck problem if there exist many table objects on the screen; 211 +* There is a little chance cause the stuck problem if use the script; 212 +* The stuck problem if use User permission; 213 +* The stuck problem when Data record upload; 214 +* There is a little chance to jump to the test interface after restart; 215 +* After the backlight is off, there is a small chance that the screen will display abnormal; 216 +* Video play cause stuck problem of General series 9150; 217 +* When the HMI just turned on, Recipe Display on the main screen is displayed as NULL; 218 +* Optimize Lua built-in library and file read/write functions; 219 +* The label of the operation value in the Operation record is displayed abnormal; 220 +* The length of channel name for Data record exceeds 32 bytes, will cause failed recording; 221 +* After entering the installment password, restart immediately, would require entering the password again; 208 208 209 -B) Password keyboard input to display the plain text first and then the * sign; 223 +(% class="wikigeneratedid" id="HDriverProtocol-4" %) 224 +Driver Protocol 210 210 211 -C) Prompt display of Screen Lock for ie and ig; 226 +* Frequently screen switching and there are many external addresses on the screen, which might have a little chance cause a stuck problem; 227 +* Ethernet free tags may cause touch problem with no response; 228 +* Ethernet free tags occur error in compiling the project; 229 +* The input/output terminals of communication with MIKOM PLC are abnormal; 230 +* The reading information from scanner will not display if it exceeds 128 characters; 231 +* Failed to communicate with the OMRON NX/NJ PLC communication after power-on the screen and then power on the PLC. 232 +* When HMI+ is just turned on, the Ethernet communication prompts timeout; 233 +* When communicate with Siemens new protocol, will let the HMI stuck on LOGO screen; 212 212 213 -D) Auto refresh of Data Record; 235 +(% class="wikigeneratedid" id="HNewfunctions-2" %) 236 +**New functions** 214 214 215 -=== **Driver Protocol** === 238 +(% class="wikigeneratedid" id="HPCSoftware-5" %) 239 +PC Software 216 216 217 -A) Communication cannot be performed after entering the backstage project; 241 +* New ie series: 3043ie, 3043ieS, 3070ie, 3102ie; 242 +* Industry purpose-designated models: ie series 3070ind, 3102ind, I series 3070ind-n; 243 +* Import and export function for Gallery file ( .blb or .plb format); 218 218 219 -B) Stuck screen problem caused by the protocol IEC60870-104 Client; 245 +(% class="wikigeneratedid" id="HHMIApplication-5" %) 246 +HMI Application 220 220 221 -== **New Functions Added** == 248 +* VNC LAN monitoring function ( require i series and PI+ models with Ethernet port and customized, the -O model in General series still use HMI Monitor System) 249 +* Resource report function to count the total memory used by the current screen; 250 +* Message prompt list (timeout , message , only available for ie series); 251 +* Timer and Trigger function in Lua script (only available for ie series); 252 +* Lua custom object, Lua table drawing, Lua curve drawing (only available for ie series); 253 +* Continuous input function of numeric and character object; 254 +* 4 Macro script functions involving file operations, FileCmpDir(), MyDeleteFile(), WriteWordToFile(), ReadWordFormFile(); 255 +* The backstage interface can upgrade PLC program to support 5VPLC program download (only available for 3000i and PI+ series); 222 222 223 -=== **PC Software** === 257 +(% class="wikigeneratedid" id="HDriverProtocol-5" %) 258 +Driver Protocol 224 224 225 - A) Newie seriesmodel: 3035ie;260 +* Keyence KV series; 226 226 227 - B) Newig seriesmodels:3070ig,3102ig;262 +== Notification of PI+ == 228 228 229 - C)License agreement for thesoftwareinstallation setupprocess;264 +* [[Download Link>>url:https://drive.google.com/file/d/1UMb8YGc5lLSfoF_UHD5A4HwE_HKd-Qg7/view?usp=sharing]] 230 230 231 - D) ObjectLock/Unlock function (Pushpin);266 += **2 Levi2PI** = 232 232 233 - E) LuaEditorto highlight the same content of the selected text;268 +== V4.3.8 == 234 234 235 -F) Font style settings of the Runbar and chart type objects; 270 +* Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Wecon%20LEVI2PI.zip]] 271 +* Dropbox: [[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=Wecon+LEVI2PI.zip&subfolder_nav_tracking=1]] 236 236 237 - G) SoftwareinstallationpackageVC 2017runtimelibrary;273 +== V4.5.6(Test Version) == 238 238 239 - ===**HMIApplication**===275 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/10Ay8dr7MK6CCpMIKEmKITG3DGipffJsI/view?usp=sharing]] 240 240 241 - A) Recipeaddressdiscontinuous addresssetting;277 += **3 HMI Monitor System** = 242 242 243 - B) Trim0display setting for numeric input;279 +== VER: 20210317 == 244 244 245 - C) AddressMappingntinuous writing settings;281 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/1RA3ui3jTCKtQTCLySjD4Qi7Ut58EYYD1/view?usp=sharing]] 246 246 247 - D) Screensaverfunction;283 += **4 Logo Making Tool** = 248 248 249 -E) Multi-Link function (not supported by ie and ig series); 250 - 251 -F) Traditional recipe function is only applicable to the LEVI2PI project that uses the Recipe function; 252 - 253 -G) Disc Record Chart; 254 - 255 -H) Lua script weather forecast function interfaces; 256 - 257 -I) The ie series supports the barcode scanner; 258 - 259 -=== **Driver Protocol** === 260 - 261 -A) Koyo Modbus RTU; 262 - 263 -B) ASK series; 264 - 265 -C) Anda inverter; 266 - 267 -D) Optimize the barcode scanner protocol; 268 - 269 -= **PIStudio Release Build VER:R05R998_V7.1.117_D20210320** = 270 - 271 -**Official Website:** 272 - 273 -**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20210320.zip]]** 274 - 275 -**Dropbox:** 276 - 277 -**[[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=PIStudio20210320.zip&subfolder_nav_tracking=1]]** 278 - 279 -== **Bugs Fixed** == 280 - 281 -=== **PC Software** === 282 - 283 -A) Fix the crash problem of the software; 284 - 285 -B) Renew the wiring diagram and pin definition diagram; 286 - 287 -C) After the address is annotated, still able to communicate in Lua script; 288 - 289 -D) Ethernet download optimization; 290 - 291 -E) The project folder contains special language characters(except Chinese and English), errors in compiling Lua file and project, failed to download the project; 292 - 293 -F) Use some fonts will cause software crash when compiling the project; 294 - 295 -=== **HMI Application** === 296 - 297 -A) Occasionally occur stuck logo problem after enable the Index of Recipe function; 298 - 299 -B) Frequently screen switching might have a little chance cause stuck problem if there exist many table objects on the screen; 300 - 301 -C) There is a little chance cause the stuck problem if use the script; 302 - 303 -D) The stuck problem if use User permission; 304 - 305 -E) The stuck problem when Data record upload; 306 - 307 -F) There is a little chance to jump to the test interface after restart; 308 - 309 -G) After the backlight is off, there is a small chance that the screen will display abnormal; 310 - 311 -H) Video play cause stuck problem of General series 9150; 312 - 313 -I) When the HMI just turned on, Recipe Display on the main screen is displayed as NULL; 314 - 315 -J) Optimize Lua built-in library and file read/write functions; 316 - 317 -K) The label of the operation value in the Operation record is displayed abnormal; 318 - 319 -L) The length of channel name for Data record exceeds 32 bytes, will cause failed recording; 320 - 321 -M) After entering the installment password, restart immediately, would require entering the password again; 322 - 323 -=== **Driver Protocol** === 324 - 325 -A) Frequently screen switching and there are many external addresses on the screen, which might have a little chance cause a stuck problem; 326 - 327 -B) Ethernet free tags may cause touch problem with no response; 328 - 329 -C) Ethernet free tags occur error in compiling the project; 330 - 331 -D) The input/output terminals of communication with MIKOM PLC are abnormal; 332 - 333 -E) The reading information from scanner will not display if it exceeds 128 characters; 334 - 335 -F) Failed to communicate with the OMRON NX/NJ PLC communication after power-on the screen and then power on the PLC. 336 - 337 -G) When HMI+ is just turned on, the Ethernet communication prompts timeout; 338 - 339 -H) When communicate with Siemens new protocol, will let the HMI stuck on LOGO screen; 340 - 341 -== **New Functions Added** == 342 - 343 -=== **PC Software** === 344 - 345 -A) New ie series: 3043ie, 3043ieS, 3070ie, 3102ie; 346 - 347 -B) Industry purpose-designated models: ie series 3070ind, 3102ind, I series 3070ind-n; 348 - 349 -C) Import and export function for Gallery file ( .blb or .plb format); 350 - 351 -=== **HMI Application** === 352 - 353 -A) VNC LAN monitoring function ( require i series and PI+ models with Ethernet port and customized, the -O model in General series still use HMI Monitor System) 354 - 355 -B) Resource report function to count the total memory used by the current screen; 356 - 357 -C) Message prompt list (timeout , message , only available for ie series); 358 - 359 -D) Timer and Trigger function in Lua script (only available for ie series); 360 - 361 -E) Lua custom object, Lua table drawing, Lua curve drawing (only available for ie series); 362 - 363 -F) Continuous input function of numeric and character object; 364 - 365 -G) 4 Macro script functions involving file operations, FileCmpDir(), MyDeleteFile(), WriteWordToFile(), ReadWordFormFile(); 366 - 367 -H) The backstage interface can upgrade PLC program to support 5VPLC program download (only available for 3000i and PI+ series); 368 - 369 -== **Driver Protocol** == 370 - 371 -A) Keyence KV series; 372 - 373 -== **Notification of PI+** == 374 - 375 -**[[Download Link>>url:https://drive.google.com/file/d/1UMb8YGc5lLSfoF_UHD5A4HwE_HKd-Qg7/view?usp=sharing]]** 376 - 377 -= **Levi2PI V4.3.8** = 378 - 379 -**Official Website:** 380 - 381 -**[[Download Link>>https://ftp.we-con.com.cn/Download/Software/Wecon%20LEVI2PI.zip]]** 382 - 383 -**Dropbox:** 384 - 385 -**[[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=Wecon+LEVI2PI.zip&subfolder_nav_tracking=1]]** 386 - 387 -= **Levi2PI V4.5.6(Test Version)** = 388 - 389 -**Google Drive** 390 - 391 -**[[Download Link>>https://drive.google.com/file/d/10Ay8dr7MK6CCpMIKEmKITG3DGipffJsI/view?usp=sharing]]** 392 - 393 -= **HMI Monitor System20210317** = 394 - 395 -**Google Drive:** 396 - 397 -**[[Download Link>>https://drive.google.com/file/d/1RA3ui3jTCKtQTCLySjD4Qi7Ut58EYYD1/view?usp=sharing]]** 398 - 399 - 400 -= **6 Logo Making Tool** = 401 - 402 -**Google Drive:** 403 - 404 -**[[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]** 285 +* Google Drive: [[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]