Changes for page 3 Software
Last modified by Hunter on 2025/11/24 09:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,8 +1,7 @@ 1 -((( 1 +1. ((( 2 2 = **1 PIStudio** = 3 3 ))) 4 - 5 -((( 4 +1. ((( 6 6 == **V10.5.45.25102301(PI9000ig, RL, RH, WP)** == 7 7 ))) 8 8 ... ... @@ -19,43 +19,48 @@ 19 19 1. Slow response of alarm record and address monitoring table, and stuck when opening the project; 20 20 1. LREAL data type cannot be read and written; 21 21 1. The overlapping screen cannot be set when the sub-screen is selected in screen; 22 -1. The encoding method options for string type data in Data record; 21 +1. Software crash caused by too many project tag and alarm points; 22 +1. The encoding method cannot be selected when recording string data; 23 23 1. Communication failure on Ethernet2 of HMI when using IP address from different Subnets for Ethernet1 and Ethernet2. 24 24 1. The addresses of X and Y are inconsistent in XY trend chart,; 25 +1. The address monitor is limited to one text address. 25 25 1. Object lock cannot be an index address; 26 -1. Laggingdisplayof camera;27 -1. Stuckon logo issue during IN, IE series upgrade;27 +1. Choppy display from the camera; 28 +1. Logo display issue during IN, IE series upgrade; 28 28 1. The IN series HMI do not support the mouse style configuration; 29 29 1. Failure to download projects to IN series HMI ; 30 30 1. PDF prompts display abnormal; 31 31 1. CAN port configuration communication error; 32 32 1. When RH device uses 4K resolution, the fonts of message prompt, background, etc. are too small; 33 -1. The issue of translator multi-language; 34 +1. Fixed:The issue of translator multi-language; 34 34 1. Invalid address mapping; 35 35 1. The advanced configuration effect of device search, device management and cloud management download project not match the expected results; 36 -1. RH-00 communication configuration does not have ETH2 configuration;37 +1. RH-00 communication port configuration does not have network port2 configuration ; 37 37 1. The ig model system keyboard is not working; 38 -1. The ig, RH series vertical screen mouse movement and touch optimized; 39 -1. 4.3-inch HMI vertical screen background display effect; 40 -1. Issue of Siemens S7-1200 DBS register reads and writes less than half, need to check the ”Read DWord” option; 41 -1. OPC UA Client reads and writes strings issue, if the new string is shorter than the old one, the end of the old string will be remained; 42 -1. If using too many element in recipe for JUNCAUTO protocol, the address will be clean and overwrite the data in low addresses; 43 -1. Write LX5V bit-in-word; 44 -1. OPC UA Client cannot connect to the server configured with authentication; 45 -1. OPC UA Client cannot reconnect normally after unplugging/plugging the network cable; 39 +1. Optimized: Remote cloud and pass-through; 40 +1. Optimized: Ig, RH series vertical screen mouse movement and touch; 41 +1. Optimization: 4.3-inch HMI vertical screen background display effect; 42 +1. Fixed:Issue of Siemens S7-1200 DBS register reads and writes less than half, need to check the ”Read Double Bytes”; 43 +1. The issue of OPCUA client reads and writes strings, if the new string is shorter than the old one, the end of the old string will be remained; 44 +1. When the recipe in the JUNCAUTO protocol is too large, the address will be clean and overwrite the data in low addresses; 45 +1. The issue with a bit in the LX5V word; 46 +1. OPCUA Client cannot connect to the server configured with authentication; 47 +1. OPCUA Client cannot reconnect normally after unplugging/plugging the network cable; 46 46 1. Changing communication methods in the background is invalid; 47 47 1. Set user permissions on the screen, but the register cannot jump to this screen; 48 -1. The issue of abnormal using indirect screenon sub-screen;50 +1. The issue of abnormal using indirect pictures on sub-screen; 49 49 1. Abnormal display of the bar graph ; 50 50 1. The RH series cannot use the CODESYS protocol; 51 51 1. When the simulator's print object is set to screenshot mode, the screen cannot be switched after a screenshot. 52 -1. Operation records do not support t extvariableinsert;54 +1. Operation records do not support multi-variable; 53 53 1. Object or font shrinking when moving numeric object; 56 +1. The issue with quotation marks in recipe data after export/import on the 9000ig HMI; 57 +1. IN1072 cannot communicate with Siemens s7-200smart; 54 54 1. CODESYS V3 protocol cannot read the Unicode string of LX6C (WSTRING); 55 -1. The issue with the UNIONtype datain Omron;59 +1. The issue with the union in Omron; 56 56 1. Communication failure after the end of VPN pass-through, ; 57 57 1. Communication failure between Keyence KV series protocol and 9000ig series; 58 -1. Gallery size limit ationper screen for IN, IE and RH series;62 +1. Optimized: Gallery size limit per screen for IN, IE and RH series; 59 59 1. Other issues; 60 60 61 61 (% class="wikigeneratedid" %) ... ... @@ -148,6 +148,7 @@ 148 148 (% class="wikigeneratedid" %) 149 149 **New drive** 150 150 155 + 151 151 1. Winding Machine MODBUS RTU Winder; 152 152 1. KEYENCE EtherNet/IP (KV-8000); 153 153 1. KEYENCE EtherNet/IP (KV-X310); ... ... @@ -178,6 +178,7 @@ 178 178 (% class="wikigeneratedid" %) 179 179 **New models** 180 180 186 + 181 181 1. GB series: GB3041, GB3070, GB3101, GB8041, GB8070-H, GB8101; 182 182 1. ig series: PI9102ig, PI9121ig, PI9150ig, PI9151ig; 183 183 1. WP series: WP2070, WP2071, WP3070, WP3071;