Wiki source code of 3 Software

Last modified by Joe on 2026/03/27 09:17

Show last authors
1 (((
2 = **1 PIStudio** =
3 )))
4
5 (((
6 == **V10.5.45.25102301(New modules: PI9000ig, RL, RH, WP)** ==
7 )))
8
9 * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_10.5.zip]]
10
11 (% class="wikigeneratedid" %)
12 **Bugs fixed**
13
14 1. Slow response issue with IN series HMI;
15 1. Slow response of alarm record and address monitoring table, and stuck when opening the project;
16 1. LREAL data type cannot be read and written;
17 1. The overlapping screen cannot be set when the sub-screen is selected in screen;
18 1. The encoding method options for string type data in Data record;
19 1. Communication failure on Ethernet2 of HMI when using IP address from different Subnets for Ethernet1 and Ethernet2.
20 1. The addresses of X and Y are inconsistent in XY trend chart,;
21 1. Object lock cannot be an index address;
22 1. Lagging display of camera;
23 1. Stuck on logo issue during IN, IE series upgrade;
24 1. The IN series HMI do not support the mouse style configuration;
25 1. Failure to download projects to IN series HMI ;
26 1. PDF prompts display abnormal;
27 1. CAN port configuration communication error;
28 1. When RH device uses 4K resolution, the fonts of message prompt, background, etc. are too small;
29 1. The issue of translator multi-language;
30 1. Invalid address mapping;
31 1. The advanced configuration effect of device search, device management and cloud management download project not match the expected results;
32 1. RH-00 communication configuration does not have ETH2 configuration;
33 1. The ig model system keyboard is not working;
34 1. The ig, RH series vertical screen mouse movement and touch optimized;
35 1. 4.3-inch HMI vertical screen background display effect;
36 1. Issue of Siemens S7-1200 DBS register reads and writes less than half, need to check the ”Read DWord” option;
37 1. OPC UA Client reads and writes strings issue, if the new string is shorter than the old one, the end of the old string will be remained;
38 1. If using too many element in recipe for JUNCAUTO protocol, the address will be clean and overwrite the data in low addresses;
39 1. Write LX5V bit-in-word;
40 1. OPC UA Client cannot connect to the server configured with authentication;
41 1. OPC UA Client cannot reconnect normally after unplugging/plugging the network cable;
42 1. Changing communication methods in the background is invalid;
43 1. Set user permissions on the screen, but the register cannot jump to this screen;
44 1. The issue of abnormal using indirect screen on sub-screen;
45 1. Abnormal display of the bar graph ;
46 1. The RH series cannot use the CODESYS protocol;
47 1. When the simulator's print object is set to screenshot mode, the screen cannot be switched after a screenshot.
48 1. Operation records do not support text variable insert;
49 1. Object or font shrinking when moving numeric object;
50 1. CODESYS V3 protocol cannot read the Unicode string of LX6C (WSTRING);
51 1. The issue with the UNION type data in Omron;
52 1. Communication failure after the end of VPN pass-through, ;
53 1. Communication failure between Keyence KV series protocol and 9000ig series;
54 1. Gallery size limitation per screen for IN, IE and RH series;
55 1. Other issues;
56
57 (% class="wikigeneratedid" %)
58 **New functions**
59
60 (% class="wikigeneratedid" %)
61 PC Software
62
63 1. Software style selection;
64 1. Screen layer;
65 1. Template screen;
66 1. Project tree objects list;
67 1. Software settings page;
68 1. The color palette adds a color picker;
69 1. Address priority configuration;
70 1. German is added to the software language;
71 1. Automatic project backup;
72 1. Address list search replacement;
73 1. Import and export of user login information;
74 1. The toolbar adds an upload project entrance and a toolbox entrance;
75 1. UI enhancement;
76 1. Software toolbar layout optimized;
77 1. Address compilation optimized;
78 1. Address integration optimized;
79 1. Project multi-language translation(Only Baidu API key);
80 1. Sound library configuration;
81 1. BACNet server;
82 1. Address search and replace;
83 1. String table text alignment;
84 1. Support for string table configuration
85 1*. Drop-down list;
86 1*. Data Record (channel name);
87 1*. Recipe(element name);
88 1*. Bit alarm text;
89 1*. Word alarm text;
90 1. Object copy attributes (font/size/color) to other languages;
91 1. Project format upgrade.(.pi to .pi2)
92 1. After the communication port connection is deleted, the communication port number is automatically sorted;
93 1. Sub-screen pops up coordinate configuration;
94 1. Alarm address communication priority (import/export);
95 1. Text tag function;
96 1. Text position vertical adjustment;
97 1. Beckhoff tag import filtering;
98 1. Schedule ;
99 1. Column Chart object;
100 1. Improve the success rate of pass-through;
101
102 (% class="wikigeneratedid" %)
103 HMI Application
104
105 1. NTP time synchronization;
106 1. New touch calibration interface;
107 1. Sub screen modal mode;
108 1. Exclusive operation;
109 1. Watchdog;
110 1. New Alarm Record;
111 1*. New alarm record interface;
112 1*. Alarm record ascending/descending order;
113 1*. Alarm record statistics;
114 1*. Diverse Alarm record styles;
115 1. Media player;
116 1. Mouse cursor style;
117 1. Timeout NC effect;
118 1. Sub-screen drag-and-drop;
119 1. Minimum pressing interval time countdown tips UI;
120 1. Additional options for trigger write addresses in alarm records;
121 1. UNICODE and GBK display format are added to alarm variables;
122 1. User permissions can configure the time of auto logout;
123 1. Text-To-Speech;
124 1. Voice broadcast;
125 1. The message prompt module supports 48 languages;
126 1. Remote management module in the background;
127 1*. Remote background;
128 1*. Access verification;
129 1*. IP Whitelist/Blacklist;
130 1*. Access log viewing;
131 1. Configure network routing mode, switch mode and WIFI hotspot in the background
132 1. RH series, 9000ig series DIP switch function
133 1*. Factory reset
134 1*. Touch calibration adaptation;
135 1. Vertical alignment method for text display;
136 1. Column Chart;
137 1. Text tag function;
138 1. Supports control via special registers to adjust the button size and spacing on the new Alarm record object, new Recipe Record object, and Column Chart;
139 1. The text for email content, user login (username), user login (description), and log message text (operation records) supports configuration via a string table.
140 1. Task scheduler;
141 1. Sub-screen pop-up position optimization;
142 1. RE and RL series support NTP (network time protocol) function;
143
144 (% class="wikigeneratedid" %)
145 **New drive**
146
147 1. Winding Machine MODBUS RTU Winder;
148 1. KEYENCE EtherNet/IP (KV-8000);
149 1. KEYENCE EtherNet/IP (KV-X310);
150 1. KEYENCE EtherNet/IP (KV-X520);
151 1. INOVANCE H5U PLC Ethernet FreeTag (fast) replaces INOVANCE H5U PLC Ethernet FreeTag ;
152 1. Siemens Ethernet FreeTag (S7 Series);
153 1. LAICARD RFID Reader;
154 1. KEYENCE Scanner HR-100B;
155 1. KEYENCE Scanner HR-100;
156 1. RONGSHI RFID Reader;
157 1. KCJ RFID Reader;
158 1. BACnet_IP;
159 1. HONEYWELL Scanner 1902-C;
160 1. Read interval time setting (RwDelay register) for modbus rtu slave.
161 1. Expanded SD,SM register address range (up to 511) for INVT_IVC1.
162 1. Leadshine LEISHINE _ SC-C32A4DS ModbusTcp;
163 1. Leadshine LEISHINE _ SC-C32A4DS ModbusRTU;
164 1. FANUC protocol;
165 1. NEWLAND Scanner;
166 1. NEWLAND Scanner COM;
167 1. Leadshine LEISHINE _ LC1000 _ Series _ TCP;
168 1. Leadshine LEISHINE _ LC1000 _ Series _ RTU;
169 1. ModBus RTU Slave (All Fuction)~-~-RwDelay register for controlling send/receive interval;
170 1. MITSUBISHI FX5U Ethernet—Bit-in-Word;
171 1. Expanded SD, SM register range for INVT_IVC1 protocol;
172 1. New CODESYS V3 protocol-read Unicode strings (WSTRING data type);
173
174 (% class="wikigeneratedid" %)
175 **New models**
176
177 1. GB series: GB3041, GB3070, GB3101, GB8041, GB8070-H, GB8101;
178 1. ig series: PI9102ig, PI9121ig, PI9150ig, PI9151ig;
179 1. WP series: WP2070, WP2071, WP3070, WP3071;
180 1. MD series: MD8102;
181 1. RL series: RL-G, RL-WF;
182 1. RH series: RH-00, RH-00-4K, RH-AG, RH-G, RH-W, RH-WG, RH-WG-CNC, RH-WG-E, RH-WG-LA, RH-WIFI;
183
184 == **V9.5.9.25091702** ==
185
186 * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.5.9.25091702.zip]]
187
188 (% class="box errormessage" %)
189 (((
190 **Notice**
191
192 1. The new version can not support general series(PI3000,PI8000,PI9000). Please use the old version (Release Build VER:R05R998_V8.4.114_D24061301) to program the general series.
193 1. **After the upgrade, only the ig series can use the Lua MQTT library.**
194 1. Projects opened with the new version cannot be opened with the old version. Please make sure to back up the project.
195 1. After the upgrade, the supported protocols will change. PI3000ig can not support the third-part Free-tags Protocol.**For details, please refer to: [[Limitation of the Ethernet communication protocol - Wecon>>url:https://docs.we-con.com.cn/bin/view/PIStudio/PLC Protocol/Limitation of the Ethernet communication protocol/]]**
196 1. Cannot roll back the version after upgrading.
197 )))
198
199 **Bugs fixed**
200
201 1. i Series 485_2 communication issues;
202 1. Pie chart control lag issues under certain circumstances;
203 1. Remote monitoring issues with the mobile app and PC client software causing link errors;
204 1. Other issues;
205
206 **New functions**
207
208 Cloud configuration supports Asian 2.0 servers;
209
210 == **V9.4.13.25053001** ==
211
212 * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.4.13.25053001.zip]]
213
214 (% class="box errormessage" %)
215 (((
216 **Notice**
217
218 1. The new version can not support general series(PI3000,PI8000,PI9000). Please use the old version (Release Build VER:R05R998_V8.4.114_D24061301) to program the general series.
219 1. **After the upgrade, only the ig series can use the Lua MQTT library.**
220 1. Projects opened with the new version cannot be opened with the old version. Please make sure to back up the project.
221 1. After the upgrade, the supported protocols will change. PI3000ig can not support the third-part Free-tags Protocol.**For details, please refer to: [[Limitation of the Ethernet communication protocol - Wecon>>url:https://docs.we-con.com.cn/bin/view/PIStudio/PLC Protocol/Limitation of the Ethernet communication protocol/]]**
222 1. Cannot roll back the version after upgrading.
223 )))
224
225 **Bugs fixed**
226
227 1. The centralized monitoring page (Device management tool) of WIN7 system using 9.3 software displays blank
228 1. Ethernet setting and 4G setting can not close in the backstage.
229 1. 3000ig, 8000ig, and RE series update interruption during project download causes Ethernet connection error
230 1. After setting the calculation and length when mapping the bit address, the mapping error occurs
231 1. ie series HSW10494 can not display the machine code.
232 1. After clearing the alarm record, the subsequent record exports are all blank.
233 1. HMI freeze when alarm record display object choose head text color and color of alarm text at the same time.
234 1. USB download error when 3070ig-C in the loading page.
235 1. Optimized the display font and format of the background of some models
236 1. 3035ie Time reset problem that may occur when downloading a project
237 1. Administrator privileges can be removed directly
238 1. HMI screen cannot be awakened by mouse after being turned off
239 1. ie series HDW register range becomes invalid when it exceeds  HDW100,000
240 1. Optimize SIEMENS S7-1200 Ethernet new protocol
241
242 **New functions**
243
244 1. Added special register HSW11816 to control the button size of the new recipe tool
245
246 **New drive**
247
248 1. JUNCAUTO Jxxx Series protocol
249
250 == **V9.3.2.25030401** ==
251
252 * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.3.2.25030401.zip]]
253
254 (% class="box errormessage" %)
255 (((
256 **Notice**
257
258 1. The new version can not support general series(PI3000,PI8000,PI9000). Please use the old version (Release Build VER:R05R998_V8.4.114_D24061301) to program the general series.
259 1. **After the upgrade, only the ig series can use the Lua MQTT library.**
260 1. Projects opened with the new version cannot be opened with the old version. Please make sure to back up the project.
261 1. After the upgrade, the supported protocols will change. PI3000ig can not support the third-part Free-tags Protocol.**For details, please refer to: [[Limitation of the Ethernet communication protocol - Wecon>>url:https://docs.we-con.com.cn/bin/view/PIStudio/PLC Protocol/Limitation of the Ethernet communication protocol/]]**
262 1. Cannot roll back the version after upgrading.
263 )))
264
265 **Bugs fixed**
266
267 1. Rectangle object disappear when using color control function.
268 1. ie series can not use the Indirect addressing function.
269 1. gif images are stuck when used.
270 1. APN cannot be saved correctly in 4G Setting.
271 1. About time span of the alarm record display,the value in LAN monitoring does not match the actual value.
272 1. The new recipe tool displays anomalies in LAN Monitoring
273 1. Recipe data cannot be saved when downloading the project via USB
274 1. Communication problem between ie series and 5V PLC.
275 1. Communication error with Omron PLC after RE/RH series restart.
276 1. The string display error for the Siemens S7-1200 protocol.
277 1. Mobile data consumption is abnormal when HMI is connected to the cloud via 4G.
278 1. Fix other bug.
279 1. Optimized shape gallery content.
280 1. Optimized some of communication protocols.
281
282 **New functions**
283
284 1. The drop-down list triggers the beeper function
285 1. Add watchdog function.
286
287 **New model**
288
289 1. PI8102ig-H
290
291 == **V9.1.18.24122702** ==
292
293 * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_9.1.18.24122702.zip]]
294
295 (% class="box errormessage" %)
296 (((
297 **Notice**
298
299 1. The new version can not support general series(PI3000,PI8000,PI9000). Please use the old version (Release Build VER:R05R998_V8.4.114_D24061301) to program the general series.
300 1. **After the upgrade, only the ig series can use the Lua MQTT library.**
301 1. Projects opened with the new version cannot be opened with the old version. Please make sure to back up the project.
302 1. After the upgrade, the supported protocols will change. PI3000ig can not support the third-part Free-tags Protocol.**For details, please refer to: [[Limitation of the Ethernet communication protocol - Wecon>>url:https://docs.we-con.com.cn/bin/view/PIStudio/PLC Protocol/Limitation of the Ethernet communication protocol/]]**
303 1. Cannot roll back the version after upgrading.
304 )))
305
306 **Bugs fixed**
307
308 1. RE series V-BOX PLC Pass-through sometime can't work properly.
309 1. RE series V-BOX data record upload can't work properly.
310 1. PI8043ig and PI3041ig recipe object unable to display properly in web side.
311 1. When entering the backstage for the first time after the screen is restarted, the first digit of the backstage password is invalid.
312 1. PI8043ig project file is too large to the logo is stuck when HMI restarted.
313 1. WIFI model can not enable after update the system.
314 1. HMI crash and freeze when downloading PLC project.
315 1. When the rectangle/arc/circle object is first initialized, a shadow will appears.
316 1. The cloud icon in backstage state error.
317 1. In off-line simulation.The left lable of Numeric Input/Display object affect natural decimal display.
318 1. MQTT tool publish bit address,the length setting is not 1,message error.
319 1. MQTT V5 protocol cannot automatically connect after network disconnection.
320 1. The cloud management tool cannot log in to non-administrator users normally.
321 1. Object lock does not work for bit switch momentary mode.
322 1. WIFI is not connected, but IP still exists.
323 1. The actual minimum pressing time of the function switch does not match the setting.
324 1. RH-WF V-BOX indicator lamp display error.
325 1. Data record display object start time setting error.
326 1. The camera display object disappear after switching screens.
327 1. After using the four arithmetic operations in address mapping, reading the value in read-only mode displays an abnormality.
328 1. Object level password does not match the setting.
329 1. In offline simulation, the new recipe tool crashes by clicking keyboard letters.
330 1. Recipe name changes when switching screens.
331 1. PLC program upload fails when PLC Pass-Through.
332 1. IDEC MicroSmart Protocol:TC CC register modifying the value of the address results in an error in the value of the next address.
333 1. Delta_AS300_TCP Protocol:D.b register cannot modify status.
334 1. OPCUA Client:communication error but have no time-out message.
335 1. IEC104client:HMI get black screen after downloading this protocol.
336
337 **New functions**
338
339 PC Software
340
341 1. New project properties page.
342 1. i/ie/ig/IN/RE/RH series all support screen style.
343 1. Download tool support RE,RH series flash light and test network.
344 1. New Device management tool.
345 1. Software homepage embedded Wecon support center.
346 1. Allow configuration preserve network configuration when download the project.
347 1. Software online update.
348 1. Scada canvas extension, new draft area.
349 1. Recipe element support bit address.
350 1. OPC UA server.
351 1. New X,Y internal registers(RH series).
352 1. 3000ig series Limitation of the Ethernet communication protocol up to 32.
353
354 HMI Application
355
356 1. New recipe object-Recipe Record:Integrated search, add, delete, download, upload, import, export, and switch recipe functions.
357 1. New backstage:The background can be exited instead of restarted,New UI,Ethernet download PLC program,USB update support update the system and project at the same time.
358 1. Remote backstage.
359 1. New system keyboard.
360 1. Character Input/Display object support multi line display.
361 1. Character Input/Display object support choose data format(UTF-8/GBK/UNICODE).
362 1. Numeric Input/Display object support more 64bit data format.
363 1. Modification of serial port parameters takes effect immediately.
364 1. RE series can be bound to V-NET.
365 1. lua script open user permission function interface.
366 1. New Multi-link function.
367 1. New special registers related to automatic logout of user functionse.
368 1. Alarm info support multiple variables.
369 1. Min.hold time countdown.
370 1. ig-O support Wecon 6V freetags protocol and CODESYS V3 protocol.
371 1. (((
372 New special registers related to displaying user storage space information.
373 )))
374
375 Driver protocol
376
377 1. OPCUA Client.
378 1. Siemens S7-1200/1500 Ethernet FreeTag.
379 1. TwinCAT PLC Ethernet.
380 1. KEYENCE KV-5000(Ethernet) using bit address in word address.
381
382 **New model**
383
384 1. RE series:RE-00,RE-00-LA,RE-4G,RE-4G-LA
385 1. RH series:RH-WIFI
386 1. ig series:PI3101ig,PI8101ig,PI8121ig
387
388 == **V8.4.114_D24061301** ==
389
390 * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/%E4%B8%B4%E6%97%B6%E5%AD%98%E6%94%BE%E5%A4%84/PIStudio_8.4.114.24061301.zip]]
391
392 **Bugs fixed**
393
394 PC Software
395
396 1. When the MQTT sending mode is set a trigger, entering the trigger address directly cannot save.
397 1. Arc object property page configuration angle cannot enter 0.
398 1. Add the 5V protocol first, and then add the printer's protocol, can't change the protocol of the printer.
399 1. The value of the meter and the color of the scale are inconsistent.
400 1. After decompile tool open, the software crash.
401 1. Off-line emulator run time the pictures of function switch object do not display.
402 1. After deleting multiple screens, the software crash.
403 1. After copying the local screen successfully, the directly compiled screen objects will be smaller than the modified screen objects.
404 1. The same project file can be opened by multiple software at the same time.
405 1. Object id duplication.
406 1. The bar graph does not use variables, but when compiling, it prompts the variable address error.
407 1. Using dynamic recipients, email addresses are not compiled and display recipient errors.
408 1. The objects compile with the address error, but there is no note about what the address error is for which objects.
409 1. When the circle/ellipse coords are in the negative area, no error message is displayed.
410 1. When text library imports excel,the blank space and subsequent data cannot be imported.
411 1. The function screen is deleted and then add it again.it cannot be added.
412 1. The wrong continuous length when compiling the address of the data record.
413 1. The wrong continuous length of lua script.
414 1. PI3041ig configuration Ethernet 2 does not take effect.
415 1. The wrong coord prompt when the rectangular objects is determined.
416 1. The data record storage in project setting is error.
417 1. Fix other problems.
418
419 HMI Application
420
421 1. The function is invalid after the function switch is pressed;
422 1. The lua function io.open cannot open files under the u disk and sd card;
423 1. The data record configuration data type is a string, the length is two characters, and it will be recorded more than two characters when data is collected record.
424 1. The data type of the word switch is BCD code, and the increase and decrease do not follow the rule of the BCD code.
425 1. "Database Format Mismatch" error after Lua script modifies table header.
426 1. PI3070ig printing part text box printing font is not clear.
427 1. In the offline simulation state, the graphics position offset occurs in the project with 1920*1080 resolution when the graphics are drawn by the address control.
428 1. drawing when the graphics position offset.
429 1. Receiving Data in Lua User Free Protocol 485 _ 2.
430 1. Lua initialization uses the we_bas_jump screen function to jump to the screen is invalid, and there is a black screen.
431 1. The data record cannot be recorded when the data record group id is 0.
432 1. Value input objects check the display natural decimal function is invalid.
433 1. To enable address control state text, must set the state sequence number, text content, and trigger settings.
434 1. MQTT is published periodically, and changing the value of the address will also publish.
435 1. The text on picture has a probability of becoming blurry.
436 1. When the reset switch triggers hiding, it cannot automatically reset.
437 1. Alarm records and data records are exported to CSV, and the table header does not switch with language switching.
438 1. The screen alarm record csv exported using DbToCsvFile has no alarm content.
439 1. The group number displayed in the recipe Group number address does not match the ID of the recipe display objects.
440 1. When the number of recipe groups is set to 0, the file name address of the index does not change when there are multiple recipe files.
441 1. The gallery is too large, causing crash.
442 1. Drop down list username can't show multilingual.
443 1. V-NET server anomaly causes device disconnection.
444 1. The HMI goes off-line due to abnormal dialing of the 4G module.
445 1. Recipe selected line ID does not match the ID in the address.
446 1. The USB download project time is not updated, and the local time is not synchronized with the computer time.
447 1. The keyboard screen cannot be closed normally through we_bas_closescreen function.
448 1. The IE series uses calibri fonts and the screen display is in Song style.
449 1. After setting floating setting as big-endian,the recipe table is displayed in Little-endian.
450 1. Long press the bit switch, and then release the bit switch after entering the static screen saver , and the bit switch cannot be reset.
451 1. After the function switch uses object password, the password is invalid after the screen jumps.
452 1. PI8150ig makes the font size smaller when using calibri font.
453 1. IN series long press upper left corner, upper right corner invalid.
454 1. Fix other problems.
455
456 Drive
457
458 1. DELTA AS300 MODBUS TCP driver operation D.b bit address invalid.
459 1. OMRONE5CC driver communication abnormal.
460 1. Xunpu printer driver prints pictures abnormally.
461 1. Rockwell Ethernet/IP (CompactLogix Series) driver communication exception.
462 1. Siemens LOGO drive on-line simulation crash.
463 1. Fix other problems.
464
465 **New functions**
466
467 Driver
468
469 1. LS MASTER Protocol driver supports bit address selection of D register.
470 1. TECO MP300 MODBUS TCP protocol.
471 1. TECO MP300 MODBUS RTU protocol.
472
473 **Precautions**
474
475 Drive 
476
477 ✎Note: WECON LX6V FreeTag Ethernet will not be maintained in the future, please switch to WECON LX6V EtherNet/IP.
478
479 ✎Note: WECON LX6V FreeTag Series will not be maintained in the future, please switch to Ethernet WECON LX6V EtherNet/IP
480
481 == V8.4.66_D23102001 ==
482
483 * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.4.66.23102001.zip]]
484
485 **Bugs fixed**
486
487 PC Software
488
489 1. In Omron free tag protocol, software crash during project compilation after tag import;
490 1. In Omron free tag protocol, the project cannot be driven in package when compiling;
491 1. 3102ig Camera Display object cannot be compiled;
492 1. Error in the length limit of the folder edit box for the image display function of the bitmap object graphical interface;
493 1. Error in the description of the expiration time for CreateInstallmentPwd tool: Modify from expiration time to next expiration time;
494 1. Crash when the conversion tool converts the History XY Plot;
495 1. It prompts wrong address when the conversion tool converts the Bit Alarm Record;
496 1. The width-height ratio is wrong when the DiscRecord Chart object switches different resolutions;
497 1. Error in compiling address of OMRON NX Ethernet/IP Protocol;
498 1. Software crash and abnormal interface update when search address in address list;
499 1. PI toolkit probably fails to connect for the first time;
500 1. The data record is incomplete, and the table column width cannot be adjusted when using DataLogTool;
501 1. Abnormal use of some tag addresses;
502 1. Modified: Inconsistent color between meter value and scale;
503 1. Error in tag array correspondence of tag protocol;
504 1. Abnormal display when configuring the underlying screen;
505 1. Abnormal compilation of 8070ig for using Camera Control object;
506 1. Some pictures are lost after compilation;
507 1. Abnormal display of bitmap of Switch object;
508 1. Shortcut key configuration will also be deleted after deleting any main screen;
509 1. HMI graphics status color cannot be changed;
510 1. Modified: After the text is successfully set in Text Library, the language content is not grayed out when entering the settings again;
511 1. (((
512 Use “Save as” once, it can open the screen file normally. But use “Save as” again to rename it with the same name, and then the folder will be empty.
513 )))
514 1. (((
515 There is no limit to the size of Custom object;
516 )))
517 1. (((
518 Sub-screen jumps to the next/previous screen (Without common screen), and right-click to switch to the target screen which is not grayed out;
519 )))
520 1. (((
521 HMI crash caused by abnormal data modification of objects;
522 )))
523 1. (((
524 “More" without Spanish translation in TLS/SSL in MQTT;
525 )))
526 1. (((
527 Translation of some objects in right-click is different from that of object bar;
528 )))
529 1. (((
530 After importing HMI project pictures, offline simulation does not display the imported pictures;
531 )))
532 1. (((
533 After modifying the function switch, it will cause communication failure;
534 )))
535 1. (((
536 Download prompt garbled in Win7;
537 )))
538 1. (((
539 The wiring diagram of 8043ig and 3043ig communication is inconsistent with the actual situation;
540 )))
541 1. (((
542 Neutral project simulation crash and download will be stuck and cannot click;
543 )))
544 1. (((
545 Draw objects exceeds boundaries after modifying coordinates to a prompted maximum value;
546 )))
547 1. (((
548 Unable to use lua object directly when not enabling Lua Script;
549 )))
550 1. (((
551 The error prompt of communication port configuration, namely there is spare %s;
552 )))
553 1. (((
554 Language selection of data recording channel does not save;
555 )))
556 1. (((
557 The project file is deleted at compile caused by setting a special path for “Save as”;
558 )))
559 1. (((
560 The preview of Table object does not follow the modification of the number of rows and columns to change;
561 )))
562 1. (((
563 Modifying the coordinates and sizes of Arc object through parameters will cause the inconsistency between graphics and actual situation;
564 )))
565 1. (((
566 Fix other problems;
567 )))
568
569 HMI Application
570
571 1. History Trend Chart cannot display curve in real-time.
572 1. HSW521.5=1 failed to delete SD card history data;
573 1. After deleting the data record, the record ID does not start from 1;
574 1. PI3000ig remote update HMI2.0 System unsuccessfully;
575 1. Timeline jump when zooming History Trend Chart in or out;
576 1. Negative decimal display of Numerical input/Display object is abnormal;
577 1. The dynamic channel display of History Trend Chart is invalid.
578 1. (((
579 Range for ie series registers is too small;
580 )))
581 1. (((
582 The login window does not pop up for user permissions;
583 )))
584 1. (((
585 The alarm record is stored in the U disk and the alarm screen does not prompt when the U disk is not inserted;
586 )))
587 1. (((
588 Crash when closing the Print Object in the sub-screen;
589 )))
590 1. (((
591 Deviation of printing screenshots in sub-screen;
592 )))
593 1. (((
594 File List does not display the files without suffix;
595 )))
596 1. (((
597 After switching languages, the screen displays the original language first and then changes to the current language.;
598 )))
599 1. (((
600 The picture is stuck when the video is played to the end in full screen;
601 )))
602 1. (((
603 Importing a recipe with CSV, the first two recipe data for the customized type are lost;
604 )))
605 1. (((
606 Importing a recipe with CSV, import failed when CSV file is utf-8 format;
607 )))
608 1. (((
609 Message alerts that the web page and screen display do not match;
610 )))
611 1. (((
612 Crash when reading customized recipe as ordinary recipe file;
613 )))
614 1. (((
615 When using FTP function, downloading project will clear the data in U disk and SD card;
616 )))
617 1. (((
618 Function switch can't jump when setting the minimum pressing time;
619 )))
620 1. (((
621 The background network of 4G module with AG cannot be used normally;
622 )))
623 1. (((
624 Word switch cannot be reset after setting the minimum pressing time;
625 )))
626 1. (((
627 Invalid recipe index address;
628 )))
629 1. (((
630 Communication will cause crash when the maximum value of Bar Chart object scale is configured with external address;
631 )))
632 1. (((
633 485_2 cannot be used when downloading PLC program by remote pass-through;
634 )))
635 1. (((
636 The trigger is invalid after pressing the function switch;
637 )))
638 1. (((
639 Fix: Lua script triggers clicks to configure objects that need to be confirmed, and the confirmation screen will flash back;
640 )))
641 1. (((
642 The Local Time Second register cannot modify the time;
643 )))
644 1. (((
645 Fixed: The data record file exported by dbtocsvfile function is blank;
646 )))
647 1. (((
648 File List failed to copy files in batches;
649 )))
650 1. (((
651 The user operation log cannot be cleared;
652 )))
653 1. (((
654 Using mqtt in HMI will report errors under specific circumstances;
655 )))
656 1. (((
657 Use of Flow Component objects causes crashes in certain situations;
658 )))
659 1. (((
660 The use of Alarm Records, Data Records, History YX Trend Plots, and Operation records has a probability of crash.
661 )))
662 1. (((
663 The startup speed of i series (HMI V2.0 system) and general series (HMI V2.0 system) becomes slow in 20230925 version.
664 )))
665 1. (((
666 The data that luasqlite saved will lose the last record when power off;
667 )))
668 1. (((
669 The modification of object startup level will invalid after power off and restart;
670 )))
671 1. (((
672 Address mapping enables bit trigger control but it can map once only;
673 )))
674 1. (((
675 Using lua script to pop up sub-screen in 20230801 version, which cannot monitor and display in LAN;
676 )))
677 1. (((
678 we_bas_getmachineinfo() function executes error;
679 )))
680 1. (((
681 After WiFi connects to the mobile phone hotspot, it still shows the connected status when closing the hotspot;
682 )))
683 1. (((
684 When the login button overlaps with the function switch in user login interface, the jump fails after login;
685 )))
686 1. (((
687 The user permissions are enabled by the object, and when it needs to be confirmed, the login interface will pop up again after entering the correct password in the login interface;
688 )))
689 1. (((
690 The two function switch objects are hidden by user permission control and stacked together. When logging in to a certain user, click on the overlapping position of the function switch is invalid;
691 )))
692 1. (((
693 The last row of lua customized table can't be deleted;
694 )))
695 1. (((
696 The initialization status of the word status display object is different from that of the configuration;
697 )))
698 1. (((
699 Trigger the record in the screen without data record or alarm record, switch back to the screen with data record, and trigger the refresh table, it cannot search the previous records;
700 )))
701 1. (((
702 Data records will lose data when exporting CSV files;
703 )))
704 1. (((
705 When the object level uses the password of each level independently, it will not be reduced to the startup level after using the high level, so it is necessary to input the password when using the low level;
706 )))
707 1. (((
708 The keyboard pop-up position of the level password of the text input object is always centered, and the keyboard position during text input is changed after setting;
709 )))
710 1. (((
711 Traditional Recipe does not enable continuous address, and upload and download fail;
712 )))
713 1. (((
714 IN1071 will crash when the installment payment screen pops up;
715 )))
716 1. (((
717 The cursor mode is switched to the selected box mode. When the simulation runs, if the cursor exceeds the simulator, it will be pulled back;
718 )))
719 1. (((
720 Fix other problems.
721 )))
722
723 Drive
724
725 1. ShortMessage_Module message group sending timeout;
726 1. When using Modbus_RTU_All Ethernet, the communication is reported error;
727 1. (((
728 OpenCAN drive communication slowly;
729 )))
730 1. (((
731 WECON LX3VP recipe continuous reading fails;
732 )))
733 1. (((
734 WECON LX5V M address write instruction length error;
735 )))
736 1. (((
737 MIT QJ71 MELSEC PROTOCOL communication abnormally;
738 )))
739 1. (((
740 Mitsubishi FX3U Drive Counter negative value display error;
741 )))
742 1. (((
743 OpenCAN drive baud rate set error;
744 )))
745 1. (((
746 Omron CP2E and PI HMI/online stimulation communication timeout;
747 )))
748 1. (((
749 User-defined Protocol single sending cannot be used;
750 )))
751 1. (((
752 Incorrect display of 32-bit signed number in MITSUBISHI FX3U/3G/3SA address CH200;
753 )))
754 1. (((
755 A physical serial port double 485 will time out when communicating at the same time;
756 )))
757 1. (((
758 User-defined Protocol does not display in online simulation;
759 )))
760 1. (((
761 Abnormal communication of HMI with azbil protocol;
762 )))
763 1. (((
764 Siemens Protocol S7300 (with PC Adaptor New) DB address is not available;
765 )))
766 1. (((
767 Modbus_TCP_Master does not reply when sending read instruction;
768 )))
769 1. (((
770 USB printer protocol uses print object; the printing will print black edges;
771 )))
772 1. (((
773 SMS protocol cannot receive and send, Add ClrMsg register to delete all information;
774 )))
775 1. (((
776 MODBUS RTU Slave (All Function) broadcasting station number communication problem. Add BrtCat station number set registers.
777 )))
778 1. (((
779 Siemens 200SMART communication abnormally;
780 )))
781 1. (((
782 Xinjie XDH communication abnormally;
783 )))
784 1. (((
785 Drive customized protocol cache cannot be cleared;
786 )))
787 1. (((
788 Errors in DWORD read/write in INOVANCE H5U_Easy PLC Ethernet Protocol;
789 )))
790 1. (((
791 Parameters such as PI timeout reconnection are not valid;
792 )))
793 1. (((
794 The matching mode of user-defined protocol receiving first and then sending;
795 )))
796 1. (((
797 Fix other problems;
798 )))
799
800 **New functions**
801
802 PC Software
803
804 1. Data record db file merge function of DataLogTool (Only HMI V2.0 system supports);
805 1. (((
806 Text color dynamic configuration of numerical value and text input object (Only HMI V2.0 system supports);
807 )))
808 1. (((
809 8000ig supports that the maximum number of configuring communication connections is 32 (Only HMI V2.0 system supports);
810 )))
811 1. (((
812 Curve object add 8 types of line configuration (Only HMI V2.0 system supports);
813 )))
814 1. (((
815 Ethernet communication supports the selection and settings of network card type (Only HMI V2.0 system supports);
816 )))
817 1. (((
818 Customized name configuration is added for communication port configuration, which can be used in address editing interface and address list interface (Only HMI V2.0 system supports);
819 )))
820 1. (((
821 **Improve compilation speed;**
822 )))
823 1. (((
824 **Function switch right-click selection to jump to the target screen;**
825 )))
826 1. (((
827 **Right-click the object and select jump to image gallery configuration;**
828 )))
829 1. (((
830 **String table configuration;**
831 )))
832 1. (((
833 **External keyboard shortcut configuration (Only ig series and MD series support);**
834 )))
835 1. (((
836 **Visual configuration of MQTT docking third-party platform (Only ig series and MD series support);**
837 )))
838 1. (((
839 **8070ig and 8102ig support video player controls.**
840 )))
841
842 HMI applications
843
844 1. Countdown prompt to enter background (Only HMI V2.0 system supports);
845 1. Background LAN security monitoring configuration (Only HMI V2.0 system supports);
846 1. Background USB flash disk upgrade mirror limit fallback version (Only HMI V2.0 system supports);
847 1. 8000ig double network port configuration (Only HMI V2.0 system supports);
848 1. Support to modify Ethernet static IP configuration through special registers (Only HMI V2.0 system supports);
849 1. User management supports multi languages (Only HMI V2.0 system supports);
850 1. 8000ig supports video play (Only HMI V2.0 system supports);
851 1. Text color dynamic configuration of numerical value and text input object (Only HMI V2.0 system supports);
852 1. Dynamic screensaver (Only HMI V2.0 system supports);
853 1. Lua SMS sending (only supported by HM I V2.0 system);
854 1. Lua obtains SIM card information (Only HMI V2.0 system supports);
855 1. Camera configuration (Only HMI V2.0 system supports);
856 1. Support PI8000/PI9000 series update system without deleting project (Only HMI V2.0 system supports);
857 1. Backstage supports multi languages switch and language customization (Only HMI V2.0 system supports);
858 1. (((
859 When switching languages, clean up the screen cache (Only HMI V2.0 system supports);
860 )))
861 1. (((
862 Register HSW1890 triggers to refresh network signal (Only HMI V2.0 system supports);
863 )))
864 1. (((
865 Register HSW1891 controls the cleaning of the screen cache (Only HMI V2.0 system supports);
866 )))
867 1. (((
868 Background stimulates the terminal (Only HMI V2.0 system supports);
869 )))
870 1. (((
871 **Dynamic text (Only HMI V2.0 system supports);**
872 )))
873 1. (((
874 **External keyboard shortcut (Only ig series and MD series support);**
875 )))
876 1. (((
877 **HMIdevice name (Only HMI V2.0 system supports);**
878 )))
879 1. (((
880 **Background supports cloud server switching (Only general 8000 series with V2.0 system, ig series and MD series supports);**
881 )))
882 1. (((
883 **Support remote screen adaptation display of vertical screen project (Only HMI V2.0 system supports);**
884 )))
885 1. (((
886 **Common lua script function of verification algorithms (Only HMI V2.0 system supports);**
887 )))
888 1. (((
889 **INSeries (IN1071, IN1072, IN1073) does not distinguish models and supports mutual projects regardless of models;**
890 )))
891
892 Driver protocol
893
894 1. WECON LX6V EtherNet / IP (Tag protocol optimized version) (Only HMI V2.0 system supports);
895 1. Rockwell EtherNet / IP (Tag protocol optimized version) (Only HMI V2.0 system supports);
896 1. OMRON EtherNet/IP (NX/NJ Series) (Tag protocol optimized version) (Only HMI V2.0 system supports);
897 1. MODBUS RTU Slave (All Fuction OneBaseAddress) can customize broadcast address;
898 1. SMS module can delete all information;
899 1. INOVANCE H5U_Easy PLC driver protocol (Serial port);
900 1. INOVANCE H5U_Easy free tag protocol drive;
901 1. Xinjie XD/XE drive;
902 1. Veichi V3 drive;
903 1. Shihlin SX6V EtherNet/IP Protocol;
904 1. CODESYS V3 drive;
905 1. Modbus_Server_IoT_Plat drive;
906 1. (((
907 MIT Q00H CPU Port PROTOCOL drive;
908 )))
909 1. (((
910 Schneider TM221 drive;
911 )))
912 1. (((
913 Delta_DVP_ModbusRTU drive;
914 )))
915 1. (((
916 INOVANCE H5U_Easy ModbusTCP drive;
917 )))
918 1. (((
919 Siemens S7-xxx Ethernet OP new drive;
920 )))
921 1. (((
922 MODBUS RTU Slave (All Function) protocol retry timeout time factor multiple ToMu;
923 )))
924 1. (((
925 Schneider TM221 drive;
926 )))
927
928 {{info}}
929 **✎Note: The maximum communication number of free tag protocol and CODESYS V3 configuration in models of each series is shown in the following table.**
930 {{/info}}
931
932 |**Series model**|**Recommended maximum number of free tag protocols**|**Recommended maximum number of CODESYS V3 protocols**
933 |8000 Series|4|Configuration is not supported.
934 |3000 Series|Configuration is not supported.|Configuration is not supported.
935 |9000 Series|Configuration is not supported.|Configuration is not supported.
936 |3000i Series|Configuration is not supported.|Configuration is not supported.
937 |ie Series (3043ies with network port)|2|Configuration is not supported.
938 |ie Series (Other models)|Configuration is not supported.|Configuration is not supported.
939 |3000ig Series|4|2
940 |8000ig Series|6|2
941 |MD3000 Series|4|Configuration is not supported.
942 |IN Series|Configuration is not supported.|Configuration is not supported.
943
944 (% class="wikigeneratedid" %)
945 **New models**
946
947 (1). ie Series: 3070ie-H;
948
949 (2). IN Series: IN1071, IN1072, IN1073;
950
951 (3). MD Series: MD3102;
952
953 (4). ig Series: 3070ig-H, 3043ig, 8070ig, 8102ig, 8043ig;
954
955 == V8.2.95_D20220928 ==
956
957 * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio_8.2.95.22092802.zip]]
958
959 (% class="wikigeneratedid" id="HBugsfixed" %)
960 **Bugs fixed**
961
962 (% class="wikigeneratedid" %)
963 PC Software
964
965 1. Optimize the function of saving project as;
966 1. The word alarm configuration cannot be imported after being exported;
967 1. The problem of abnormal resolution after png image editing and external import; 
968 1. The password of project designer can be input into Chinese;
969 1. The 8150ig model cannot be configured with camera search function;
970 1. The probability of recipe setting cannot be saved;
971 1. When simulating the "WECON" directory of C disk is adjusted to "HMIEmulation" directory;
972 1. The problem that the position of text parts does not change after setting coordinates;
973 1. The interface displays an redundant scroll bar when creating a new screen;
974 1. The download tool only scans one of the network segments when there are multiple ip under the computer network card;
975 1. The content of data records is abnormal and cannot be imported after being exported;
976 1. The welcome interface opens the project and incorrectly prompts the project to be occupied;
977 1. The installation path affects clicking offline simulation to pop up online simulation;
978 1. The font size of the newly built-in screen 5004 is abnormal when switching to the size of 1920*1080;
979 1. When the data record is stored in U disk and SD card, the size of the data record is not limited during compilation;
980 1. The name of the newly created part in the right-click menu bar is consistent with the name in the part list;
981 1. The problem that when compiling ie series projects, the memory size of the components of the picture exceeds the problem that no error is reported;
982 1. When the U disk upgrade tool selects an invalid drive letter to generate a file, it does not normally prompt errors;
983 1. The prompting wrong parameters when opening engineering parameters in the project of repairing vertical screen;
984
985 (% class="wikigeneratedid" %)
986 HMI Application
987
988 1. Keyboard without "&" the question of symbols;
989 1. The camera function on HMI V2.0 system will report error messages;
990 1. The camera picture is still displayed after switching pictures on HMI V2.0 system;
991 1. The project of Chinese character designer password cannot be simulated;
992 1. The screenshots of printed parts are invalid when saved to SD card;
993 1. The project downloaded by Ethernet cannot be uploaded normally;
994 1. The debugging window moves the left and right scroll bars, and the upper and lower scroll bars will jump to the bottom;
995 1. The manual APN of 4G setting cannot be saved;
996 1. The system is upgraded to V2.0, the horizontal and vertical screens are abnormal;
997 1. PI3043ie can't communicate with plc after upgrading;
998 1. HMI2.0 background dynamic and static switch does not cache static IP;
999 1. PI3070ig ftpserver can't access the service;
1000 1. V-BOX can't download PI3070N through download;
1001 1. The starting time will automatically change after the data record query setting interface pops up;
1002 1. The flow component displaying deviation in web pages;
1003 1. The alarm record header of switching language is not switched;
1004 1. The current alarm record will show the problem of historical alarm record;
1005 1. The camera uses power failure to save the address, and the camera state is not initialized after power failure and restart;
1006 1. The camera directly enters the account number, password and device serial number without enabling the search module;
1007 1. PI audio plays with sound and the volume is displayed as 0;
1008 1. When the hot spot name of the connection has single quotation marks, the network cannot recognize the problem;
1009 1. Add background U Disk upgrade updates the network configuration function (downloads the Ethernet parameters in the project parameters synchronously to the HMI
1010 1. The ig series can't use ezviz cloud function when using 4G Internet of Things card to surf the Internet;
1011 1. The screen saver cannot be exited on HMI V2.0 system;
1012 1. The communication is disconnected and cannot be reconnected after ig series VPN penetrates;
1013 1. Optimize the polling speed of VB trigger script;
1014
1015 Drive the updated
1016
1017 1. The abnormal communication caused by recipe reading;
1018
1019 Driver Protocol
1020
1021 1. Add Omron (NX/NJ) free tag driver;
1022
1023 **New functions**
1024
1025 PC Software
1026
1027 1. The picture compression function in the project parameters;
1028 1. Compatible switching models of PI8150ig (1920*1080 and 1280*720).
1029 1. The template picture with resolution of 1920*1080 of ig.
1030 1. ig series does not check the size limit of data record files.
1031
1032 HMI Application
1033
1034 1. The rotation function of switch components (only supported by HMI V2.0 system);
1035 1. Automatic rotation of rotation bitmap control and address control hiding function (only supported by HMI V2.0 system);
1036 1. Ftp service function (only supported by HMI V2.0 system);
1037 1. Ezviz cloud camera function (only supported by HMI V2.0 system);
1038 1. Lua curve custom component sliding bar function and draw 8 curves (only supported by HMI V2.0 system);
1039 1. Background language boot configuration (only supported by HMI V2.0 system);
1040 1. The function of modifying the header of data records (only supported by HMI V2.0 system);
1041 1. Historical trend style 6 and style 7 (only supported by HMI V2.0 system);
1042 1. PI8150ig (1920*1080rn) resolution;
1043
1044 == V8.2.62_D20220625 ==
1045
1046 * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220625.zip]]
1047 * Google Drive: [[Download Link>>https://drive.google.com/file/d/1kJuuzxjPj5mZmeazhGxrs3lGyMceqmYj/view?usp=sharing]]
1048
1049 (% class="wikigeneratedid" id="HBugsfixed" %)
1050 **Bugs fixed**
1051
1052 (% class="wikigeneratedid" id="HPCSoftware" %)
1053 PC Software
1054
1055 1. Cloud.xml does not exist in the project file of 8000 series and cannot access cloud;
1056 1. Lua prompting error when double click the project path of General series in Screen Management;
1057 1. The cursor moving into the area of background script will be disappeared;
1058 1. After the Lua script is changed, it is not compiled, and there is no prompt when clicking offline simulation;
1059 1. DLView fails to import excel files;
1060 1. There is an abnormality when creating image files into Udisk;
1061 1. Orientation options missing for Slide switch;
1062 1. COM3 Configuration missing for following models: 3070i-A and 3102i-A;
1063 1. When the download tool downloads the project, it does not prompt when the file does not exist;
1064 1. SD Card option missing for following models: 3070i-A, 3102i-A, 3070i-C, 3102i-C;
1065 1. Some of the same font size, font style is different when the font size is displayed abnormally;
1066 1. Optimize the built-in screen No.1008, add Time and Date objects;
1067 1. Optimize the remote download;
1068 1. Optimize the U disk upgrade function;
1069 1. Prompt when the downloads a file with a long path;
1070 1. The ig series vertical screen option is available now;
1071
1072 (% class="wikigeneratedid" id="HHMIApplication" %)
1073 HMI Application
1074
1075 1. The i series freezes with HSW24 soft reboot;
1076 1. Debugging window cannot be closed on the ig monitoring page;
1077 1. Abnormal record time of ig Data record;
1078 1. The ig series abnormal ethernet communication;
1079 1. The register for network status HSW850 abnormal value;
1080 1. Lua we_bas_getstring script function execution error;
1081 1. The video title with English brackets cannot be played;
1082 1. Touch screen will lead to HMI freezes when keyboard input and cursor is enabled;
1083 1. Logo failed download for PI8150ig (before the firmware version 0313);
1084 1. After PI8000 series remote download PLC program, PLC cannot communicate;
1085 1. PI8000 series and ig series online V-NET but cannot remote control;
1086 1. Background Ethernet static IP configuration is not saved;
1087 1. The ig series WVPN remote pass through fails;
1088 1. Lua timer does not perform timing operations according to the interval;
1089
1090 (% class="wikigeneratedid" id="HDriverProtocol" %)
1091 Driver Protocol
1092
1093 1. PI8000ig and Yudian sensor cannot communicate;
1094 1. Modify the name of the Wecon LX6V protocol, the old version project must be re-selected;
1095 1. The following serial port protocols have intermittent communication timeout issue: Siemens S7-200 smart, modbus, INVT, etc.
1096 1. Taian AP200 C register can not read the value
1097
1098 (% class="wikigeneratedid" id="HNewfunctions" %)
1099 **New functions**
1100
1101 (% class="wikigeneratedid" id="HPCSoftware-1" %)
1102 PC Software
1103
1104 1. VB script customize naming function;
1105 1. PI Suite toolkit;
1106 1. System upgrade function;
1107 1. PIRecordUpload has added User permission function;
1108 1. Cloud function of 8000 and 9000 series;
1109
1110 (% class="wikigeneratedid" id="HHMIApplication-1" %)
1111 HMI Application
1112
1113 The following function is only available for ig series:
1114
1115 1. Slider of History trend chart can set the color and transparency;
1116 1. Continuous read and write addresses in Lua script;
1117 1. Built-in Lua extension module;
1118 1. Display network camera on HMI screen for 8150ig;
1119 1. Vertical Display;
1120 1. The priority settings of Cloud connection method from backstage configuration;
1121 1. Lua script supports https protocol now;
1122 1. UDisk Download project prohibit upload function;
1123 1. Lua script luasqlite operation;
1124 1. The following function is only available for i,ie,ig series and HMI+ system:
1125 1. All series remove the restriction of special machine code;
1126 1. Recipe 64-bit floating point number data format;
1127 1. UDisk Pop-Up function;
1128 1. Interconversion between GB2312 and UTF-8 encoding;
1129 1. UDisk download PLC multi-file function;
1130 1. Modifitable datetime prohibited;
1131 1. Color configuration of Line object;
1132
1133 (% class="wikigeneratedid" id="HDriverProtocol-1" %)
1134 Driver Protocol
1135
1136 1. Inovance H3U Ethernet;
1137 1. Rockwell micro850 Ethernet/IP Free Tags;
1138 1. Wecon LX6V Free Tags;
1139
1140 (% class="wikigeneratedid" id="HNewmodels" %)
1141 **New models**
1142
1143 1. The i series: 3070i-A, 3102i-A, 3070i-C, 3102i-C, 3070i-2S, 3102i-2S
1144 1. The ie series: 3043ie-T
1145 1. The ig series: 8150ig
1146
1147 (% class="box infomessage" %)
1148 (((
1149 ✎Note:
1150
1151 * To use the new functions avaiable from new version, the project needs to be downloaded twice;
1152 * After the wifi module (version V1.1) of 3070ig is soft restarted, if the wifi is not recognized from background interface, please repower to recover it;
1153 )))
1154
1155 == V7.2.198_D20211210 ==
1156
1157 * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]]
1158 * Google Drive: [[Download Link>>https://drive.google.com/file/d/1lRfgoOwAs7lgL4b-ZdVUvE6itHWCpfd5/view?usp=sharing]]
1159
1160 (% class="wikigeneratedid" id="HBugsfixed-1" %)
1161 **Bugs fixed**
1162
1163 (% class="wikigeneratedid" id="HPCSoftware-2" %)
1164 PC Software
1165
1166 * Optimize the display style of text objects;
1167 * Optimize Lua script file size limitation to 512KB;
1168 * Optimize the import of text library and the limitation to 2000;
1169 * Protocol driver names standardized;
1170 * Font size is open to 512;
1171 * Lua script debugging window can be configured as enabled or not in Project Settings;
1172 * Optimize the font display of Runbar;
1173 * Optimized the forced backup function of project file, now you can click the cancel button to not backup;
1174 * Optimized and adjusted the default size of the password keyboard screen of newly-created projects;
1175 * Wrong display range of the History trend chart;
1176 * The font display of Drop-down List on PC is different from the actual screen;
1177 * Software crash caused by deleting the Address Library name;
1178 * General Series SMS protocol cannot be selected;
1179
1180 (% class="wikigeneratedid" id="HHMIApplication-2" %)
1181 HMI Application
1182
1183 * Multi-Language display of text fonts;
1184 * Password keyboard input to display the plain text first and then the * sign;
1185 * Prompt display of Screen Lock for ie and ig;
1186 * Auto refresh of Data Record;
1187
1188 (% class="wikigeneratedid" id="HDriverProtocol-2" %)
1189 Driver Protocol
1190
1191 * Communication cannot be performed after entering the backstage project;
1192 * Stuck screen problem caused by the protocol IEC60870-104 Client;
1193
1194 (% class="wikigeneratedid" id="HNewfunctions-1" %)
1195 **New functions**
1196
1197 (% class="wikigeneratedid" id="HPCSoftware-3" %)
1198 PC Software
1199
1200 * New ie series model: 3035ie;
1201 * New ig series models: 3070ig, 3102ig;
1202 * License agreement for the software installation setup process;
1203 * Object Lock/Unlock function (Pushpin);
1204 * Lua Editor to highlight the same content of the selected text;
1205 * Font style settings of the Runbar and chart type objects;
1206 * Software installation package VC 2017 runtime library;
1207
1208 (% class="wikigeneratedid" id="HHMIApplication-3" %)
1209 HMI Application
1210
1211 * Recipe address discontinuous address setting;
1212 * Trim 0 display setting for numeric input;
1213 * Address Mapping continuous writing settings;
1214 * Screensaver function;
1215 * Multi-Link function (not supported by ie and ig series);
1216 * Traditional recipe function is only applicable to the LEVI2PI project that uses the Recipe function;
1217 * Disc Record Chart;
1218 * Lua script weather forecast function interfaces;
1219 * The ie series supports the barcode scanner;
1220
1221 (% class="wikigeneratedid" id="HDriverProtocol-3" %)
1222 Driver Protocol
1223
1224 * Koyo Modbus RTU;
1225 * ASK series;
1226 * Anda inverter;
1227 * Optimize the barcode scanner protocol;
1228
1229 == V7.1.117_D20210320 ==
1230
1231 * Official Website: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20210320.zip]]
1232 * Dropbox: [[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=PIStudio20210320.zip&subfolder_nav_tracking=1]]
1233
1234 (% class="wikigeneratedid" id="HBugsfixed-2" %)
1235 **Bugs fixed**
1236
1237 (% class="wikigeneratedid" id="HPCSoftware-4" %)
1238 PC Software
1239
1240 * Fix the crash problem of the software;
1241 * Renew the wiring diagram and pin definition diagram;
1242 * After the address is annotated, still able to communicate in Lua script;
1243 * Ethernet download optimization;
1244 * The project folder contains special language characters(except Chinese and English), errors in compiling Lua file and project, failed to download the project;
1245 * Use some fonts will cause software crash when compiling the project;
1246
1247 (% class="wikigeneratedid" id="HHMIApplication-4" %)
1248 HMI Application
1249
1250 * Occasionally occur stuck logo problem after enable the Index of Recipe function;
1251 * B) Frequently screen switching might have a little chance cause stuck problem if there exist many table objects on the screen;
1252 * There is a little chance cause the stuck problem if use the script;
1253 * The stuck problem if use User permission;
1254 * The stuck problem when Data record upload;
1255 * There is a little chance to jump to the test interface after restart;
1256 * After the backlight is off, there is a small chance that the screen will display abnormal;
1257 * Video play cause stuck problem of General series 9150;
1258 * When the HMI just turned on, Recipe Display on the main screen is displayed as NULL;
1259 * Optimize Lua built-in library and file read/write functions;
1260 * The label of the operation value in the Operation record is displayed abnormal;
1261 * The length of channel name for Data record exceeds 32 bytes, will cause failed recording;
1262 * After entering the installment password, restart immediately, would require entering the password again;
1263
1264 (% class="wikigeneratedid" id="HDriverProtocol-4" %)
1265 Driver Protocol
1266
1267 * Frequently screen switching and there are many external addresses on the screen, which might have a little chance cause a stuck problem; 
1268 * Ethernet free tags may cause touch problem with no response;
1269 * Ethernet free tags occur error in compiling the project;
1270 * The input/output terminals of communication with MIKOM PLC are abnormal;
1271 * The reading information from scanner will not display if it exceeds 128 characters;
1272 * Failed to communicate with the OMRON NX/NJ PLC communication after power-on the screen and then power on the PLC.
1273 * When HMI+ is just turned on, the Ethernet communication prompts timeout;
1274 * When communicate with Siemens new protocol, will let the HMI stuck on LOGO screen;
1275
1276 (% class="wikigeneratedid" id="HNewfunctions-2" %)
1277 **New functions**
1278
1279 (% class="wikigeneratedid" id="HPCSoftware-5" %)
1280 PC Software
1281
1282 * New ie series: 3043ie, 3043ieS, 3070ie, 3102ie;
1283 * Industry purpose-designated models: ie series 3070ind, 3102ind, I series 3070ind-n;
1284 * Import and export function for Gallery file ( .blb or .plb format);
1285
1286 (% class="wikigeneratedid" id="HHMIApplication-5" %)
1287 HMI Application
1288
1289 * VNC LAN monitoring function ( require i series and PI+ models with Ethernet port and customized, the -O model in General series still use HMI Monitor System)
1290 * Resource report function to count the total memory used by the current screen;
1291 * Message prompt list (timeout , message , only available for ie series);
1292 * Timer and Trigger function in Lua script (only available for ie series);
1293 * Lua custom object, Lua table drawing, Lua curve drawing (only available for ie series);
1294 * Continuous input function of numeric and character object;
1295 * 4 Macro script functions involving file operations, FileCmpDir(), MyDeleteFile(), WriteWordToFile(), ReadWordFormFile();
1296 * The backstage interface can upgrade PLC program to support 5VPLC program download (only available for 3000i and PI+ series);
1297
1298 (% class="wikigeneratedid" id="HDriverProtocol-5" %)
1299 Driver Protocol
1300
1301 * Keyence KV series;
1302
1303 == Notification of PI+ ==
1304
1305 * [[Download Link>>url:https://drive.google.com/file/d/1UMb8YGc5lLSfoF_UHD5A4HwE_HKd-Qg7/view?usp=sharing]]
1306
1307 = **2 Levi2PI** =
1308
1309 == V4.6.2 ==
1310
1311 * [[Download Link>>https://ftp.we-con.com.cn/Download/Software/Levi2PI%20v4.6.2.zip]]
1312
1313 = **3 HMI Monitor System** =
1314
1315 == VER: 20210317 ==
1316
1317 * Google Drive: [[Download Link>>https://drive.google.com/file/d/1RA3ui3jTCKtQTCLySjD4Qi7Ut58EYYD1/view?usp=sharing]]
1318
1319 = **4 StartupLogoTool** =
1320
1321 * V3.0.19: [[Download Link>>https://ftp.we-con.com.cn/Download/Software/StartupLogoTool%20V3.0.19.zip]]
1322 * old version: [[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]