1 = **PIStudio Release Build VER:R05R998_V8.2.62_D20220625** =
2
3 (% class="wikigeneratedid" %)
4 **Official Website:**
5
6 (% class="wikigeneratedid" %)
7 **[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220625.zip]]**
8
9 **Google Drive:**
10
11 **[[Download Link>>https://drive.google.com/file/d/1kJuuzxjPj5mZmeazhGxrs3lGyMceqmYj/view?usp=sharing]]**
12
13 == **Bugs Fixed** ==
14
15 === **PC Software** ===
16
17 A) Cloud.xml does not exist in the project file of 8000 series and cannot access cloud;
18
19 B) Lua prompting error when double click the project path of General series in Screen Management;
20
21 C) The cursor moving into the area of background script will be disappeared;
22
23 D) After the Lua script is changed, it is not compiled, and there is no prompt when clicking offline simulation;
24
25 E) DLView fails to import excel files;
26
27 F) There is an abnormality when creating image files into Udisk;
28
29 G) Orientation options missing for Slide switch;
30
31 H) COM3 Configuration missing for following models: 3070i-A and 3102i-A;
32
33 I) When the download tool downloads the project, it does not prompt when the file does not exist;
34
35 J) SD Card option missing for following models: 3070i-A, 3102i-A, 3070i-C, 3102i-C;
36
37 K) Some of the same font size, font style is different when the font size is displayed abnormally;
38
39 L) Optimize the built-in screen No.1008, add Time and Date objects;
40
41 M) Optimize the remote download;
42
43 N) Optimize the U disk upgrade function;
44
45 O) Prompt when the downloads a file with a long path;
46
47 P) The ig series vertical screen option is available now;
48
49 === **HMI Application** ===
50
51 A) The i series freezes with HSW24 soft reboot;
52
53 B) Debugging window cannot be closed on the ig monitoring page;
54
55 C) Abnormal record time of ig Data record;
56
57 D) The ig series abnormal ethernet communication;
58
59 E)The register for network status HSW850 abnormal value;
60
61 F) Lua we_bas_getstring script function execution error;
62
63 G)The video title with English brackets cannot be played;
64
65 H)Touch screen will lead to HMI freezes when keyboard input and cursor is enabled;
66
67 I) Logo failed download for PI8150ig (before the firmware version 0313);
68
69 J) After PI8000 series remote download PLC program, PLC cannot communicate;
70
71 L) PI8000 series and ig series online V-NET but cannot remote control;
72
73 M) Background Ethernet static IP configuration is not saved;
74
75 N) The ig series WVPN remote pass through fails;
76
77 O)Lua timer does not perform timing operations according to the interval;
78
79 === **Driver Protocol** ===
80
81 A) PI8000ig and Yudian sensor cannot communicate;
82
83 B) Modify the name of the Wecon LX6V protocol, the old version project must be re-selected;
84
85 C)The following serial port protocols have intermittent communication timeout issue: Siemens S7-200 smart, modbus, INVT, etc.
86
87 D)Taian AP200 C register can not read the value
88
89 == **New Functions Added** ==
90
91 === **PC Software** ===
92
93 A) VB script customize naming function;
94
95 B) PI Suite toolkit;
96
97 C) System upgrade function;
98
99 D) PIRecordUpload has added User permission function;
100
101 E) Cloud function of 8000 and 9000 series;
102
103 === **HMI Application** ===
104
105 The following function is only available for ig series:
106
107 A) Slider of History trend chart can set the color and transparency;
108
109 B) Continuous read and write addresses in Lua script;
110
111 C) Built-in Lua extension module;
112
113 D) Display network camera on HMI screen for 8150ig;
114
115 E) Vertical Display;
116
117 F) The priority settings of Cloud connection method from backstage configuration;
118
119 G) Lua script supports https protocol now;
120
121 H) UDisk Download project prohibit upload function;
122
123 I) Lua script luasqlite operation;
124
125 The following function is only available for i,ie,ig series and HMI+ system:
126
127 J)All series remove the restriction of special machine code;
128
129 K) Recipe 64-bit floating point number data format;
130
131 L) UDisk Pop-Up function;
132
133 M) Interconversion between GB2312 and UTF-8 encoding;
134
135 N) UDisk download PLC multi-file function;
136
137 O) Modifitable datetime prohibited;
138
139 P) Color configuration of Line object;
140
141 === **Driver Protocol** ===
142
143 A Inovance H3U Ethernet;
144
145 B Rockwell micro850 Ethernet/IP Free Tags;
146
147 C Wecon LX6V Free Tags;
148
149 == **New Models** ==
150
151 (1)The i series: 3070i-A, 3102i-A, 3070i-C, 3102i-C, 3070i-2S, 3102i-2S
152
153 (2)The ie series: 3043ie-T
154
155 (3)The ig series: 8150ig
156
157 ✎Note:
158
159 1)To use the new functions avaiable from new version, the project needs to be downloaded twice;
160
161 2)After the wifi module (version V1.1) of 3070ig is soft restarted, if the wifi is not recognized from background interface, please repower to recover it;
162
163 = **PIStudio Release Build VER:R05R998_V7.2.198_D20211210** =
164
165 (% class="wikigeneratedid" %)
166 **Official Website:**
167
168 (% class="wikigeneratedid" %)
169 **[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]]**
170
171 **Google Drive:**
172
173 **[[Download Link>>https://drive.google.com/file/d/1lRfgoOwAs7lgL4b-ZdVUvE6itHWCpfd5/view?usp=sharing]]**
174
175 == **Bugs Fixed** ==
176
177 === **PC Software** ===
178
179 A) Optimize the display style of text objects;
180
181 B) Optimize Lua script file size limitation to 512KB;
182
183 C) Optimize the import of text library and the limitation to 2000;
184
185 D) Protocol driver names standardized;
186
187 E) Font size is open to 512;
188
189 F) Lua script debugging window can be configured as enabled or not in Project Settings;
190
191 G) Optimize the font display of Runbar;
192
193 H) Optimized the forced backup function of project file, now you can click the cancel button to not backup;
194
195 I) Optimized and adjusted the default size of the password keyboard screen of newly-created projects;
196
197 J) Wrong display range of the History trend chart;
198
199 K) The font display of Drop-down List on PC is different from the actual screen;
200
201 L) Software crash caused by deleting the Address Library name;
202
203 M) General Series SMS protocol cannot be selected;
204
205 === **HMI Application** ===
206
207 A) Multi-Language display of text fonts;
208
209 B) Password keyboard input to display the plain text first and then the * sign;
210
211 C) Prompt display of Screen Lock for ie and ig;
212
213 D) Auto refresh of Data Record;
214
215 === **Driver Protocol** ===
216
217 A) Communication cannot be performed after entering the backstage project;
218
219 B) Stuck screen problem caused by the protocol IEC60870-104 Client;
220
221 == **New Functions Added** ==
222
223 === **PC Software** ===
224
225 A) New ie series model: 3035ie;
226
227 B) New ig series models: 3070ig, 3102ig;
228
229 C) License agreement for the software installation setup process;
230
231 D) Object Lock/Unlock function (Pushpin);
232
233 E) Lua Editor to highlight the same content of the selected text;
234
235 F) Font style settings of the Runbar and chart type objects;
236
237 G) Software installation package VC 2017 runtime library;
238
239 === **HMI Application** ===
240
241 A) Recipe address discontinuous address setting;
242
243 B) Trim 0 display setting for numeric input;
244
245 C) Address Mapping continuous writing settings;
246
247 D) Screensaver function;
248
249 E) Multi-Link function (not supported by ie and ig series);
250
251 F) Traditional recipe function is only applicable to the LEVI2PI project that uses the Recipe function;
252
253 G) Disc Record Chart;
254
255 H) Lua script weather forecast function interfaces;
256
257 I) The ie series supports the barcode scanner;
258
259 === **Driver Protocol** ===
260
261 A) Koyo Modbus RTU;
262
263 B) ASK series;
264
265 C) Anda inverter;
266
267 D) Optimize the barcode scanner protocol;
268
269 = **PIStudio Release Build VER:R05R998_V7.1.117_D20210320** =
270
271 **Official Website:**
272
273 **[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20210320.zip]]**
274
275 **Dropbox:**
276
277 **[[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=PIStudio20210320.zip&subfolder_nav_tracking=1]]**
278
279 == **Bugs Fixed** ==
280
281 === **PC Software** ===
282
283 A) Fix the crash problem of the software;
284
285 B) Renew the wiring diagram and pin definition diagram;
286
287 C) After the address is annotated, still able to communicate in Lua script;
288
289 D) Ethernet download optimization;
290
291 E) The project folder contains special language characters(except Chinese and English), errors in compiling Lua file and project, failed to download the project;
292
293 F) Use some fonts will cause software crash when compiling the project;
294
295 === **HMI Application** ===
296
297 A) Occasionally occur stuck logo problem after enable the Index of Recipe function;
298
299 B) Frequently screen switching might have a little chance cause stuck problem if there exist many table objects on the screen;
300
301 C) There is a little chance cause the stuck problem if use the script;
302
303 D) The stuck problem if use User permission;
304
305 E) The stuck problem when Data record upload;
306
307 F) There is a little chance to jump to the test interface after restart;
308
309 G) After the backlight is off, there is a small chance that the screen will display abnormal;
310
311 H) Video play cause stuck problem of General series 9150;
312
313 I) When the HMI just turned on, Recipe Display on the main screen is displayed as NULL;
314
315 J) Optimize Lua built-in library and file read/write functions;
316
317 K) The label of the operation value in the Operation record is displayed abnormal;
318
319 L) The length of channel name for Data record exceeds 32 bytes, will cause failed recording;
320
321 M) After entering the installment password, restart immediately, would require entering the password again;
322
323 === **Driver Protocol** ===
324
325 A) Frequently screen switching and there are many external addresses on the screen, which might have a little chance cause a stuck problem; 
326
327 B) Ethernet free tags may cause touch problem with no response;
328
329 C) Ethernet free tags occur error in compiling the project;
330
331 D) The input/output terminals of communication with MIKOM PLC are abnormal;
332
333 E) The reading information from scanner will not display if it exceeds 128 characters;
334
335 F) Failed to communicate with the OMRON NX/NJ PLC communication after power-on the screen and then power on the PLC.
336
337 G) When HMI+ is just turned on, the Ethernet communication prompts timeout;
338
339 H) When communicate with Siemens new protocol, will let the HMI stuck on LOGO screen;
340
341 == **New Functions Added** ==
342
343 === **PC Software** ===
344
345 A) New ie series: 3043ie, 3043ieS, 3070ie, 3102ie;
346
347 B) Industry purpose-designated models: ie series 3070ind, 3102ind, I series 3070ind-n;
348
349 C) Import and export function for Gallery file ( .blb or .plb format);
350
351 === **HMI Application** ===
352
353 A) VNC LAN monitoring function ( require i series and PI+ models with Ethernet port and customized, the -O model in General series still use HMI Monitor System)
354
355 B) Resource report function to count the total memory used by the current screen;
356
357 C) Message prompt list (timeout , message , only available for ie series);
358
359 D) Timer and Trigger function in Lua script (only available for ie series);
360
361 E) Lua custom object, Lua table drawing, Lua curve drawing (only available for ie series);
362
363 F) Continuous input function of numeric and character object;
364
365 G) 4 Macro script functions involving file operations, FileCmpDir(), MyDeleteFile(), WriteWordToFile(), ReadWordFormFile();
366
367 H) The backstage interface can upgrade PLC program to support 5VPLC program download (only available for 3000i and PI+ series);
368
369 == **Driver Protocol** ==
370
371 A) Keyence KV series;
372
373 == **Notification of PI+** ==
374
375 **[[Download Link>>url:https://drive.google.com/file/d/1UMb8YGc5lLSfoF_UHD5A4HwE_HKd-Qg7/view?usp=sharing]]**
376
377 = **Levi2PI V4.3.8** =
378
379 **Official Website:**
380
381 **[[Download Link>>https://ftp.we-con.com.cn/Download/Software/Wecon%20LEVI2PI.zip]]**
382
383 **Dropbox:**
384
385 **[[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=Wecon+LEVI2PI.zip&subfolder_nav_tracking=1]]**
386
387 = **Levi2PI V4.5.6(Test Version)** =
388
389 **Google Drive**
390
391 **[[Download Link>>https://drive.google.com/file/d/10Ay8dr7MK6CCpMIKEmKITG3DGipffJsI/view?usp=sharing]]**
392
393 = **HMI Monitor System20210317** =
394
395 **Google Drive:**
396
397 **[[Download Link>>https://drive.google.com/file/d/1RA3ui3jTCKtQTCLySjD4Qi7Ut58EYYD1/view?usp=sharing]]**
398
399
400 = **6 Logo Making Tool** =
401
402 **Google Drive:**
403
404 **[[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]**